Search NASA⌕ Search

SEARCH · Search NASA

Results for “chromatography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Tandem pyrolysis evolved gas–gas chromatography–mass spectrometry

Analysis of byproducts from thermal degradation of polymer materials provides a wealth of information about a materials’ composition, thermal stability, degradation mechanisms, and kinetics. However, regardless of the instrumentation used, only limited information is obtainable from a single experiment. Microfurnace technology, when interfaced to a gas chromatography-mass spectrometry (GC-MS), can be used to obtain both thermal and chemical information via evolved gas analysis-MS (EGA-MS) and GC-MS analysis modes. While both EGA-MS and Py-GC-MS are valuable when characterizing polymer materials, at least two experiments on distinct samples are required, which can be a liability for clear interpretation of results from inhomogeneous samples. Here, we seek to overcome this limitation by combining EGA-MS and Py-GC-MS modes in a single experimental setup. Further, this was done by developing new gas line modifications to allow for tandem Pyrolysis Evolved Gas-Gas Chromatography-Mass Spectrometry (Py/EG-GC-MS) analysis. Verification of Py/EG-GC-MS analysis was performed using a polystyrene standard. Results demonstrate successful Py/EG-GC-MS analysis for the first-time showing the potential of these modifications for application in areas where sample is limited or direct correlation of products to the thermal profile is desirable such as in forensics or product-specific kinetics.

36 MATERIALS SCIENCE↗

Behavior of Water Near Multimodal Chromatography Ligands and Its Consequences for Modulating Protein–Ligand Interactions

Multimodal chromatography is a powerful approach for purifying proteins that uses ligands containing multiple modes of interaction. Recent studies have shown that selectivity in multimodal chromatographic separations is a function of the ligand structure and geometry. Here, we performed molecular dynamics simulations to explore how the ligand structure and geometry affect ligand–water interactions and how these differences in solution affect the nature of protein–ligand interactions. Our investigation focused on three chromatography ligands: Capto MMC, Nuvia cPrime, and Prototype 4, a structural variant of Nuvia cPrime. First, the solvation characteristics of each ligand were quantified via three metrics: average water density, fluctuations, and residence time. We then explored how solvation was perturbed when the ligand was bound to the protein surface and found that the probability of the phenyl ring dewetting followed the order: Capto MMC > Prototype 4 > Nuvia cPrime. To explore how these differences in dewetting affect protein–ligand interactions, we calculated the probability of each ligand binding to different types of residues on the protein surface and found that the probability of binding to a hydrophobic residue followed the same order as the dewetting behavior. This study illustrates the role that wetting and dewetting play in modulating protein–ligand interactions.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a Gas Chromatography with High-Resolution Time-of-Flight Mass Spectrometry Methodology for BDNPA/F

Analysis of thermally labile compounds such as bis(2,2-dinitropropyl) acetal/formal (BDNPA/F), an energetic plasticizer, is usually performed via liquid chromatography (LC) as opposed to gas chromatography (GC) due to thermal decomposition in the inlet or the analytical column. While LC is a powerful technique, the analysis of volatile and semivolatile compounds is best suited to GC. Herein, a method was developed for a gas chromatograph coupled to high-resolution mass spectrometer (GC-HRMS), utilizing a programmable temperature vaporizer (PTV) inlet. A subset of the native compounds and several produced by the thermal decomposition of BDNPA/F in the inlet were evaluated by using multiple PTV inlet parameters to determine the optimal ramp rate and final temperature of the inlet (60 °C/min from 60 to 325 °C). The optimized GC-HRMS method nearly reduced all thermal decomposition, allowing for an excellent separation to be obtained. Furthermore, multiple ionization methods, including electron impact (EI), negative chemical ionization (NCI), and positive chemical ionization (PCI), were used to explore the many chemical differences between the BDNPA/F samples. A preliminary investigation of the benefits of using GC-HRMS to evaluate the chemical differences between unaged and aged BDNPA/F samples for unique insight was evaluated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of Seven Organic Impurities in FD&C Yellow No. 6 by Ultra-High-Performance Liquid Chromatography

The U.S. Food and Drug Administration (FDA) batch certifies FD&C Yellow No. 6 (Y6) to ensure that the color additive meets requirements published in the Code of Federal Regulations (CFR), including specifications for seven organic manufacturing impurities consisting of two intermediates, a reaction by-product, an impurity originating from an intermediate, and three subsidiary colors. An ultra-high-performance liquid chromatography (UHPLC) method was developed and validated for determining seven organic impurities in Y6. For comparison, the currently used high-performance liquid chromatography (HPLC) method was also validated. The new UHPLC method uses a 1.7 µm particle size biphenyl column with aqueous ammonium formate and methanol as eluants. Analytes are identified by comparing their retention times and UV-visible spectra to those of reference standards. Calibration is performed in the presence of the dye matrix and analyte levels are determined from their peak areas. UHPLC and HPLC validation studies obtained linear calibration curves and excellent values for limits of detection, limits of quantitation, recovery, repeatability, and intermediate precision for all analytes. Survey analyses of 30 samples using the UHPLC and HPLC methods yielded results that were consistent within experimental error; however, the UHPLC method provided more accurate results for two analytes that coelute using the HPLC method. The UHPLC method satisfies the accuracy and precision requisites for routine certification of Y6. The UHPLC method is faster and generates less waste than the HPLC method while delivering better sensitivity, separation, and accuracy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new TEVA-DGA chromatography procedure to separate Pu, Am, and Np from bulk U materials

Trace actinides present within uranium (U) material are diagnostic signatures of U processing history. For example, the emplacement of U material within the high neutron-flux environment of a nuclear reactor can cause neutron capture of U to form 241-plutonium ( 241 Pu). Plutonium-241 then decays to progeny isotopes 241-americium ( 241 Am) and 237-neptunium ( 237 Np); therefore, the presence and relative abundances of these trace actinides is indicative of the material’s production history and intended employment (Mayer et al., 2013). During a pre-detonation nuclear forensics investigation, measurement of trace actinide 241 Pu, 241 Am, and 237 Np concentrations by an analytical laboratory may be requested. However, chemically purifying these elements from bulk U is a challenging and involved procedure requiring several sequential chromatography columns across 4+ days. To expedite Pu-Am-Np separation from bulk U material, and to improve the yield recovery of these elements, this DHS Postdoc Fellowship has worked to create a new chromatography separation chemistry.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Algorithms and file structures to extend and enhance liquid chromatography and ion mobility mass spectrometry workflows (CRADA Final Report)

The purpose of this project was to continue supporting customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based protein and metabolite characterization. PNNL worked with Agilent to design, implement, evaluate, and demonstrate new algorithms and integrated them as functionalities into the PNNL-PreProcessor software. The project augmented PNNL’s capabilities to analyze complex proteomics and metabolomics samples. These capabilities are directly beneficial to DOE and PNNL efforts to characterize and analyze these compounds in microbial and plant communities. The project assisted Agilent in further developing improved instrument-software solutions combining liquid chromatography and ion mobility with mass spectrometry for widespread applications in life sciences and other fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chelation ion chromatography as an automated, and cost-effective analytical technique for REE determination: method development and applications

Rare earth elements (REEs), as critical minerals, have important uses in modern energy and technologies, yet are vulnerable to potential supply chain disruptions. To establish domestic REE supply chain, efficient REE detection methods for resource characterization and mineral processing will be needed to accelerate innovations for domestic REE recovery. This study developed a rapid, novel, and cost-effective for REE detection method using ion chromatography (IC) for aqueous samples. Various REE-targeted eluent gradients and post-column agent compositions were tested on the chelation ion chromatography (CIC) with UV-vis detector for optimal separation and quantification of REEs within approximately 20 min. The single-channel pump to deliver the post-column solution to UV-vis detector was replaced with a 4-channel gradient pump, to increase operation and maintenance efficiencies. After method optimization, resulting calibration curves for more than ten REEs achieved high coefficients of determination (R2>0.999) and low relatively standard deviations (below 3.24%), demonstrating sub-ppm level detection limits (0.0897 to 0.1149 mg/L). The reliability of the CIC method was validated through comparison with inductively coupled plasma mass spectrometry (ICP-MS), showing strong agreement in REE recovery from certified standards. The impact of metal ions and salts on REE recovery using CIC was also systematically investigated. CIC consistently exhibited reliable performance in the presence of salt solutions such as NaCl and Na₂SO₄ (up to 10,000 mg/L). Our study also found the presence of high concentrations of Al ions (at 10,000 mg/L) significantly influenced REE determination, and elevated concentrations of Ca ions affected the recovery of specific REEs, including La, Ce, and Pr. The CIC method was further tested on REE-containing eluents from solvent extraction tests out of fly ash leachates. REE detection from these real processing fluids were reported to achieve 90% to 100% recovery rate from our IC method, compared to ICP-MS results. This study underscores the potential of CIC as a reliable and efficient alternative for REE determination in complex matrices. It also highlights the importance of minimizing select interfering metal ions in solutions to ensure accurate results. The REE CIC method presents a promising, low-maintenance, salt-tolerant, and cost-effective alternative to traditional analytical methods for REE analysis.

detection of rare earth elements (REE)↗

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems

Engineering cellular metabolism for targeted biosynthesis can require extensive design-build-test-learn (DBTL) cycles as the engineer works around the cell's survival requirements. Alternatively, carrying out DBTL cycles in cell-free environments can accelerate this process and alleviate concerns with host compatibility. A promising approach to cell-free metabolic engineering (CFME) leverages metabolically active crude cell extracts as platforms for biomanufacturing and for rapidly discovering and prototyping modified proteins and pathways. Realizing these capabilities and optimizing CFME performance requires methods to characterize the metabolome of lysate-based cell-free platforms. That is, analytical tools are necessary for monitoring improvements in targeted metabolite conversions and in elucidating alterations to metabolite flux when manipulating lysate metabolism. In this work, metabolite analyses using high-performance liquid chromatography (HPLC) coupled with either optical or mass spectrometric detection were applied to characterize metabolite production and flux in E. coli S30 lysates. Specifically, this report describes the preparation of samples from CFME lysates for HPLC analyses using refractive index detection (RID) to quantify the generation of central metabolic intermediates and by-products in the conversion of low-cost substrates (i.e., glucose) to various high-value products. The analysis of metabolite conversion in CFME reactions fed with 13 C-labeled glucose through reversed-phase liquid chromatography coupled to tandem mass spectrometry (MS/MS), a powerful tool for characterizing specific metabolite yields and lysate metabolic flux from starting materials, is also presented. Altogether, applying these analytical methods to CFME lysate metabolism enables the advancement of these systems as alternative platforms for executing faster or novel metabolic engineering tasks.

59 BASIC BIOLOGICAL SCIENCES↗

Development of Extraction Chromatography Resins for Metal Ion Separations in Analytical Radiochemistry

Extraction chromatography resins are widely used in pretreatment for such as the analysis of radionuclides and metal ions, as well as the quantification of isotopes. These resins have been developed for the purpose of improving selectivity, reducing the generation amount of waste liquid, and performing simpler and faster separation compared with other separation methods such as solvent extraction, ion exchange, and coprecipitation. This paper explains, in an easy-to-understand manner, this extraction chromatography, including extractants, diluents, solid supports, etc. (A.O.)

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Spent-fuel recycling molecule degradation product standards can be produced with preparative liquid chromatography

Solvent systems used for spent nuclear fuel separation schemes are subject to intense radiation fields from the spent fuel, resulting in a degradation of separation performance over time from both the radiolytic destruction of active compounds (extractants, holdback agents, etc.) and the production of degradation compounds (compounds produced from the destruction of the active compounds). Development of a quantitative understanding of the effects of radiolysis on separations is impeded by a near-complete lack of availability of degradation products from chemical manufacturers. Synthesis of these degradation products through traditional means is both cost and time prohibitive, inhibiting advancement of new fuel separation processes. We hypothesize that comprehensive sets of degradation products can be synthesized using preparative radiolysis, and purified using high performance liquid chromatography in quantities sufficient for unequivocal identification and subsequent use as quantitative analytical studies. Achieving this objective will facilitate development of a much more accurate understanding of radiolysis reactions and their effects on solvent extraction processes, positioning Idaho National Laboratory (INL) in a leadership role in the science of fuel cycle separations. We propose producing these degradation compounds by irradiating concentrated samples of solvent ligands in the INL gamma irradiator, separating the resulting mixture with preparative chromatography, and removing the mobile phase in the separated fractions with a vacuum concentrator. This will yield milligram to gram quantities of purified degradation products, sufficient for fundamental research, at a fraction of the time and cost of synthesis. Facile production of separation molecule degradation products at minimal cost will enable the fundamental research that will accelerate the development of fuel cycles that will ensure the competitiveness of nuclear energy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crosslinked polymeric ionic liquid stationary phases incorporating a combination of silver(I) and copper(II) ions for olefin separations by gas chromatography

The development of efficient and selective olefin separation technologies is a critical challenge within the chemical industry given the high energy demands of conventional cryogenic distillation methods. To address this, the study explores the effectiveness of polymeric ionic liquid (PIL) stationary phases in gas chromatography (GC) that incorporate both silver(I) ([Ag + ]) and copper(II) ([Cu 2+ ]) ions for enhanced olefin separation via π-complexation interactions. Further, the effects of both non-crosslinked and crosslinked PIL stationary phases containing varying ratios of [Ag⁺] and [Cu²⁺] ions were systematically investigated to evaluate their impact on the separation of olefins from paraffins and structurally similar olefins. Retention measurements using a broad range of olefinic probes revealed that [Ag⁺] ions provided stronger and more consistent π-complexation in PIL-based stationary phases, while [Cu²⁺] ions preferentially enhance olefin retention in crosslinked systems. Furthermore, thermal stability studies showed that [Ag + ]-containing PIL stationary phases maintain stable olefin separation efficiency over prolonged exposure under elevated temperatures, while crosslinked PIL stationary phases containing [Cu 2+ ] ions exhibited stronger retention due to increased surface adsorption. These findings provide insight into the tunability of metal–olefin interactions using PIL-based stationary phases and suggest design strategies for achieving thermally stable and highly selective chromatographic separations of unsaturated hydrocarbons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structures of HIV-1 Neutralizing Antibody 10E8 Delineate the Mechanistic Basis of Its Multi-Peak Behavior on Size-Exclusion Chromatography

Antibody 10E8 is capable of effectively neutralizing HIV through its recognition of the membrane-proximal external region (MPER), and a suitably optimized version of 10E8 might have utility in HIV therapy and prophylaxis. However, 10E8 displays a three-peak profile on size-exclusion chromatography (SEC), complicating its manufacture. Here we show cis-trans conformational isomerization of the Tyr-Pro-Pro (YPP) motif in the heavy chain 3rd complementarity-determining region (CDR H3) of antibody 10E8 to be the mechanistic basis of its multipeak behavior. We observed 10E8 to undergo slow conformational isomerization and delineate a mechanistic explanation for effective comodifiers that were able to resolve its SEC heterogeneity and to allow an evaluation of the critical quality attribute of aggregation. We determined crystal structures of single and double alanine mutants of a key di-proline motif and of a light chain variant, revealing alternative conformations of the CDR H3. We also replicated both multi-peak and delayed SEC behavior with MPER-antibodies 4E10 and VRC42, by introducing a Tyr-Pro (YP) motif into their CDR H3s. Our results show how a conformationally dynamic CDR H3 can provide the requisite structural plasticity needed for a highly hydrophobic paratope to recognize its membrane-proximal epitope.

60 APPLIED LIFE SCIENCES↗

Understanding Biomass and Polymer Feedstock Variability Through Analytical Pyrolysis and Two Dimensional Gas Chromatography and Mass Spectrometry

Moving toward a circular carbon economy requires enabling reuse of carbon-based macromolecules like those in biomass and polymers. Meeting this goal requires increased upcycling of waste products into higher value products. For biomass waste such as corn stover, pine needles, or bark, one approach is using pyrolysis to convert these feedstocks into bio-oil that can be used for liquid fuel or transformed into other hydrocarbon based products, like bio-polymers. Waste plastics can be upcycled or recycled into new products, or alternatively converted into bio-oil by pyrolysis. Macromolecules from biomass and polymers are challenging to convert into liquid fuel or chemical feedstocks, due to large and sometimes heterogeneous networks of polymeric bonds. We work with the Idaho National Laboratory’s Biomass Feedstock National User Facility and Department of Energy’s Feedstock Conversion Interface Consortium to develop a molecular understanding of biomass variability that occurs naturally and as a result of storage or preprocessing techniques applied to feedstocks, to understand chemical reactions occurring during pyrolysis and other biomass or polymer conversion techniques. Using two dimensional gas chromatography mass spectrometry coupled to analytical pyrolysis provides insight into the molecular changes that occur during the pyrolysis event, and these insights can extend to bench or pilot scale pyrolysis conversions. Understanding pyrolysis of biomass and polymers at a molecular level contributes to development of new tools to predict and manipulate the optimum conditions and identify the best storage, preprocessing, and conversion techniques to maximize output of specific high-value chemical species in the conversion to fuels, or to characterize feedstocks for blending before pyrolysis. Identification and understanding of the molecular level changes resulting from novel preprocessing techniques that can be used to control and manipulate the chemical output of bench or pilot scale pyrolysis is another focus of investigation, including the use of gamma irradiation, acid, or enzyme pre-treatments. We also focus on the impacts of storage conditions and techniques, which can affect moisture levels, degradation, and impacts from naturally occurring microbes in the environment.

09 BIOMASS FUELS↗

Inline small-angle X-ray scattering-coupled chromatography under extreme hydrostatic pressure

As continuing discoveries highlight the surprising abundance and resilience of deep ocean and subsurface microbial life, the effects of extreme hydrostatic pressure on biological structure and function have attracted renewed interest. Biological small-angle X-ray scattering (BioSAXS) is a widely used method of obtaining structural information from biomolecules in solution under a wide range of solution conditions. Due to its ability to reduce radiation damage, remove aggregates, and separate monodisperse components from complex mixtures, size-exclusion chromatography-coupled SAXS (SEC-SAXS) is now the dominant form of BioSAXS at many synchrotron beamlines. While BioSAXS can currently be performed with some difficulty under pressure with non-flowing samples, it has not been clear how, or even if, continuously flowing SEC-SAXS, with its fragile media-packed columns, might work in an extreme high-pressure environment. Here we show, for the first time, that reproducible chromatographic separations coupled directly to high-pressure BioSAXS can be achieved at pressures up to at least 100 MPa and that pressure-induced changes in folding and oligomeric state and other properties can be observed. Further, the apparatus described here functions at a range of temperatures (0°C–50°C), expanding opportunities for understanding biomolecular rules of life in deep ocean and subsurface environments.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of Glycolate in Radioactive Waste by Ion Chromatography (IC) and Proton Nuclear Magnetic Resonance (H NMR)

Here, in preparation for implementing the Nitric-Glycolic (NG) acid flowsheet for the Savannah River Site (SRS) Liquid Waste System (LWS), analytical methods for determining glycolate at low concentration, below 20 mg/L in radioactive samples, were developed to support system management and safety. To accommodate the wide range of LWS matrix conditions, two alternative methods were developed, refined, and demonstrated for glycolate analysis in radioactive waste samples: ion chromatography (IC) and a proton nuclear magnetic resonance (H NMR). Investigators validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. The deployed IC method is applicable in low to moderate ionic strength samples and requires sample pretreatment using a Dionex OnGuard II H + cartridge. The deployed H NMR method is more labor intensive but provides options for a broader range of matrices. Based on the results, high quality glycolate analysis of the Defense Waste Processing Facility (DWPF) condensate in Tank 22 is feasible by IC down to approximately 12 mg/L. Using H NMR, glycolate may be determined to 8 mg/L or lower depending on the run time with the potential for broader applicability of the method to higher ionic strength conditions in other tanks of the SRS LWS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evaluation of two extraction chromatography resins for scandium and titanium separation for medical isotope production

Scandium-47 ( 47 Sc) can be used in nuclear medicine as a therapeutic-diagnostic, or "theragnostic," radioactive medical isotope for cancer detection and treatment. The 47 Sc isotope can be produced through the photonuclear reaction 48 Ti(γ,p) 47 Sc by irradiating enriched 48 Ti target material. The enriched target material necessary for production is costly; 48 TiO 2 costs ~ $\$$1550/g, and targets can be > 50 g ($\$$77,500) to produce medically relevant amounts of 47 Sc. In order to keep costs low, a highly efficient separation of scandium from bulk titanium is desired, along with efficient methods for recycling the target material. Here this research is focused on evaluating efficient methods for the separation of scandium from bulk quantities of titanium using commercially available diglycolamide-based and hydroxamate-based extraction chromatography resins (DGA resin and ZR resin, respectively). The sorption of 47 Sc and Ti on these resins were investigated at varying concentrations of HNO 3 , HCl, H 2 SO 4 , and HF to explore how they might be used in a large-scale production/processing setting.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Behavior of selenium and arsenic in $\mathrm{HCl}$ and $\mathrm{HNO}$ 3 on $\mathrm{TRU, TEVA, DGA,}$ and $\mathrm{Pb}$ extraction chromatography resins

The uptake behavior of 73 As and 75 Se was studied in HCl and HNO 3 -H 2 O 2 solutions on commercial extraction chromatography resins (TEVA, TRU, DGA, and Pb resin). There was no uptake of 73 As or 75 Se from HNO 3 media. From HCl, there was 75 Se uptake at high concentrations on all the resins and no uptake of 73 As. Separations of 75 Se and 73 As on these resins have high yields and high radiopurity for 73 As, but limited recovery of 75 Se. TRU and TEVA resin may have potential for use in isotope generators as 75 Se can be retained for at least 26 days with repeated elutions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Purification of legacy Ra-226 from ingrown Pb-210 using cation exchange chromatography

With the growing interest in using radium-226 (Ra-226) as a source material to produce essential radionuclides for targeted alpha therapies, the global demand for Ra-226 has surged, rendering its acquisition difficult. The shortage necessitates the exploration of alternative pathways to obtain this isotope beyond traditional commercial vendors. Legacy radium sources remain widespread due to Ra-226’s historical use but require the removal of ingrown daughter products to obtain a pure Ra-226 product. In conclusion, a straightforward and effective purification method for legacy Ra-226 ampoules has been developed using cation exchange chromatography, enabling the reliable conversion of legacy materials into high-purity Ra-226 solutions.

and nuclear chemistry↗