Search NASA⌕ Search

SEARCH · Search NASA

Results for “circuit breakers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Secured control of circuit breakers in a digital substation

Methods and systems for secured control of circuit breakers in an electric power substation against undesired direct operation. Consequences of a malicious action are prevented or mitigated using a validation approach that either blocks the command or ensures a negligible effect on system operation. An example method, suitable for implementation in a monitoring device in an electric power substation, includes receiving a command to open or close a circuit breaker. In response, one or more state parameters for the electric power network that comprises the substation are then predicted, the predicted state parameters reflecting an operating state for the network under the assumption that the received command is executed. The method further comprises comparing the predicted one or more state parameters to corresponding operational limits. Execution of the command is then blocked, in response to determining that one or more of the predicted state parameters violate the corresponding operational limits.

Kondabathini, Anil↗

A Balanced Approach to Molded Case Circuit Breaker Maintenance

Abstract – NFPA 70E mandates that "overcurrent devices shall be maintained in accordance with the manufacturer's instructions or industry consensus standards". At our laboratory this mandate is law, because 10 CFR 851 requires adherence to NFPA 70 and 70E. This begs the question, exactly what are those manufacturer's instructions, and what do the industry consensus standards require? In particular with Molded Case Circuit Breakers (MCCB's), how does one meet these requirements and still apply a balanced approach in a maintenance program when the facilities range from brand new construction to over fifty years old, and where circuit breakers exist that have been made by virtually every major manufacturer? This paper examines the instructions given by the various manufacturers, and examines the standards that exist, along with major guides and white paper recommendations. Both the consistencies and the inconsistencies are examined, recommendations are compared, and a general consensus of recommendations emerges. The various maintenance particulars are examined, from cycling of breakers and thermography to inverse thermal and instantaneous primary injection trip testing. The results of an FMEA (Failure Modes and Effects Analysis) was conducted at our facility; the results of that FMEA and the recommendations of that FMEA for maintenance of MCCB’s are presented. In this paper, we have examined the recommendations of manufacturers, standards, and guides that provide the guidelines for maintenance of molded case circuit breakers. Although many conflicts exist, a consensus of nearly universal recommendations emerges. A balanced approach to maintenance that provides the maximum safety benefit within the bounds of economic feasibility can be developed. We provide a condensation of the existing literature with references, a visual summary of that literature and propose a recommended maintenance approach.

42 ENGINEERING↗

Wide Bandgap Solid State Circuit Breakers for AC and DC Microgrids

The objective of the project is to develop a new class of ultrafast, self-powered, programmable, autonomously operated, bidirectional solid state circuit breakers (SSCBs) using wide band gap (WBG) semiconductors with 1000X reduction in response time and 5X reduction in cost in comparison to commercial mechanical circuit breakers. In particular, we have developed two SSCB prototypes of 380VDC/220VAC/20A and 1000VDC/10A using GaN power switches for common distribution-level AC and DC voltages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Overriding Faulty Circuit Breakers

Retainer keeps power on in emergency. Simple mechanical device attaches to failed aircraft-type push/pull circuit breaker to restore electrical power temporarily until breaker replaced. Device holds push/pull button in closed position; unnecessary for crewmember to hold button in position by continual finger pressure. Sleeve and plug hold button in, overriding mechanical failure in circuit breaker. Windows in sleeve show button position.

Robbins, Richard L.↗

Method to improve the repeatability of dynamic contact resistance measurement test results for high-voltage circuit breakers

Dynamic contact resistance measurement (DRM) is an effective technique to evaluate the contact condition in substations without dismantling circuit breakers. However, performing DRM tests with unsuitable test parameters will cause low repeatability of the test results, and even lead to the misdiagnosis of contact condition. Performing the DRM tests at high DC injected current can improve the repeatability. This paper studies the mechanism of the DC injected current on the repeatability of the DRM test results, and it also promotes a new determination method of the DC injected current amplitude. The impact of the DC injected current on DRM test results is reviewed. The mechanism of the DC injected current on DRM test results is investigated by analysing the chemical composition of the contact surface, the force exerted on the contacts, and the temperatures of a-spots on the contacts' surface. Results indicate that not the Lorentz force, but the temperature of a-spots is the primary influencing factor. The amplitude of the DC injected current can be determined by calculating the temperatures of the a-spot on the contacts' surface. And this method can also be used for other SF6 circuit breakers.

Cheng, Tingting↗

T-Type Modular DC Circuit Breaker (T-Breaker) for Future DC Networks

The developed T-Type Modular DC Circuit Breaker (T-Breaker) technology offers an all-in-one solution to challenges in DC networks. This includes swift fault detection and protection, power transient stability, and power quality improvement, achieved through the utilization of wide bandgap (WBG) power semiconductors and energy storage devices. The T-Breaker not only facilitates rapid fault current detection and interruption but also implements fault current limiting through active insertion of storage devices or by operating WBG devices in the saturation region. Additionally, with the assistance of energy storage devices, potential overvoltage issues on power devices induced by control signal misalignment can be mitigated. The T-Breaker can be regulated to perform shunt current injection/absorption using the vertical arm and series voltage insertion via the horizontal arm, thereby enhancing DC system stability during voltage or load power fluctuation transients. The OSU team and Raytheon team actively worked together on designing, fabricating, assembling, and testing of two T-Breaker prototypes. The first prototype is rated at 1 kV, 500 A with half-bridge (unipolar) structure to validate the T-Breaker concept. The second prototype is rated at 20 kV, 50 A with full-bridge (bipolar) topology which can reach an efficiency of 99.977%, realize a power density of 60.2 MW/m3, and eliminate the 500-A fault current with a fault response time of around 20 µs. The prototypes show great feasibility of adopting this technology in multiple applications including electrified aircraft, super charging stations, data centers, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SCR-based Medium Voltage DC Solid-State Circuit Breaker

This paper describes a medium voltage solid-state circuit breaker (SSCB) based on SCR technology, featuring short fault-interruption time and a minimal turn-off auxiliary circuit. The SSCB design incorporates a specialized SCR and a commutation circuit designed with an objective to reduce the required SCR hold-off/turn-off time, tq, which primarily determines the fault interruption duration. To validate the design, simulation analysis is presented, and a 1.5 kV 300 A SSCB prototype has been built and tested. The results confirm the effectiveness of the proposed design philosophy demonstrating the SSCB's ability to interrupt a 200 A load current in less than 50 μs. The proposed SCR-based SSCB has been developed for DC applications but is equally applicable to AC applications.

Kandula, Prasad [ORNL] (ORCID:0000000174017284)↗

Electric Field Characteristics of an Arc-Induction-Type DC Circuit Breaker Combined with a Magnet for Stability in the DC Power Grid

For stability in the direct current (DC) power grid, it is very important to limit the current of the fault section and to protect the system in the fault condition. That is the core technology of the DC power grid. This paper suggests characteristics and a limited range of the fault current for the new model as the significant protecting technology in the DC power grid. Such new model is the arc-induction-type DC circuit breaker (CB) combined with a magnet. The magnetic arc-induction-type direct-current circuit breaker (DCCB) consists of a neodymium magnet, an induction needle, and electrical contacts. During fault operation, the arc occurring between the contacts is induced to the induction needle. To increase the induction effect, Lorentz force is applied to blow the arc. A magnet was applied to reduce the initial fault current and to induce magnetic flux. The simulation data were analyzed using the Maxwell 3D software program. The electric field included the electric force and the electric charge. Therefore, it could analyze the arc as the electric field. The simulation was performed based on the preceding study on induction needle. As a result of the simulation, it was confirmed that the electric field value of the induction needle increased when the DCCB was combined with a magnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A 4 kV/120 A SiC Solid-State DC Circuit Breaker Powered By a Load-Independent IPT System

This article introduces a 4 kV/120 A solid-state dc circuit breaker (DCCB) based on discrete SiC mosfets. The DCCB is designed in a five-layer tower structure. Each layer consists of a circular main conduction branch and an attached gate driver. There are two primary benefits of the proposed DCCB. First, it reduces conduction loss with multiple devices in parallel. Second, it achieves an ultrafast response speed with SiC mosfets. Moreover, the gate drivers of the DCCB are powered by a domino inductive power transfer (IPT) system. It achieves the load-independent constant-voltage output characteristics, which means the outputs are immune to load variations. Additionally, an IPT system prototype is implemented to test the power transfer performance. At 500-kHz frequency, the total output power reaches 15.73 W, which is sufficient to power on five gate drivers, with a peak transfer efficiency of 75.4%. The IPT system is tested to power a 4 kV/120 A DCCB prototype. It validates that the DCCB is effective to turn off 120 A current within 3.5 μs.

42 ENGINEERING↗

A Single Passive Gate-Driver for Series Connected Power Devices in DC Circuit Breaker Applications

This letter proposes a novel single passive gate driver solution based on passive devices to control series-connected power semiconductor devices for dc circuit breaker (DCCB) applications. The transient suppression devices (e.g., metal oxide varistors) are utilized to achieve natural voltage balancing among the series devices, while providing the discharge path of the gate capacitor of the upper devices. Here, the proposed method is very simple, cost effective and more compact compared with conventional voltage balancing method-based DCCBs. Besides, gate voltage oscillation during the voltage recovery process is mitigated by the addition of an extra gate capacitor. Simulation and experimental results are provided to verify the effectiveness of proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improved multiline HVDC circuit breakers with asymmetric conducting branches

Here, this paper proposes two improved multiline HVDC circuit breakers (DCBs) for HVDC grid applications, including type-1 improved multiline DCB and type-2 improved multiline DCB. The two improved DCBs draw on the core idea of extended H-bridge. m adjacent DC transmission lines share a single main breaker (MB) and surge arrester. Due to the extended H-bridge design, bidirectional current flow can be achieved by a unidirectional MB. An upper conducting branch and a lower conducting branch are connected to a DC line. The upper and lower conducting branches in the two improved multiline DCBs are asymmetric. The upper conducting branch of both two improved DCBs is formed by a load commutation switch (LCS) and an ultra-fast disconnector (UFD). The lower conducting branch of the type-1 improved scheme is composed of a diode and a UFD; and of the type-2 improved scheme is made up of diode stack. Compared with other DCBs, the proposed type-1 DCB and type-2 DCB are more cost effective. Among the five DCBs, the type-2 improved scheme requires the least number of individual switching actions. The effectiveness and feasibility of the proposed schemes are verified through simulation of a bipolar three-terminal HVDC grid in PSCAD/EMTDC.

42 ENGINEERING↗

Remote control circuit breaker evaluation testing

Engineering evaluation tests were performed on several models/types of remote control circuit breakers marketed in an attempt to gain some insight into their potential suitability for use on the space shuttle vehicle. Tests included the measurement of several electrical and operational performance parameters under laboratory ambient, space simulation, acceleration and vibration environmental conditions.

Bemko, L. M.↗

Wide bandgap optical switch circuit breaker

A high-voltage switch is adapted for use as a medium-voltage direct current circuit breaker, which provides a low-cost, small-footprint device to mitigate system faults. In one example, a method for operating a wideband optical device includes illuminating the wide bandgap optical device with a light within a first range of wavelengths and a first average intensity, allowing a current to propagate therethrough without substantial absorption of the current, illuminating the wide bandgap optical device with light within the first range of wavelengths and a second average intensity that is lower than the first average intensity to allow a sustained current flow though the wide bandgap optical device, and illuminating the wide bandgap optical device with light within a second range of wavelengths to stop or substantially restrict propagation of the current through the wide gap material.

Voss, Lars F.↗

Optical fiber imaging for high speed plasma motion diagnostics: Applied to low voltage circuit breakers

An integrated portable measurement system is described for the study of high speed and high temperature unsteady plasma flows such as those found in the vicinity of high current switching arcs. An array of optical fibers allows the formation of low spatial resolution images, with a maximum capture rate of 1x10{sup 6} images per second (1 MHz), with 8 bit intensity resolution. Novel software techniques are reported to allow imaging of the arc; and to measure arc trajectories. Results are presented on high current (2 kA) discharge events in a model test fixture and on the application to a commercial low voltage circuit breaker.

42 ENGINEERING↗

Fast, Controllable, and Modular Solid-State Circuit Breaker Design for Battery Management Systems

Electric power grid is experiencing a growing number of distributed and inertia-free generation resources. To facilitate the growing generation and load demands, and ensure stable operation, energy storage systems, especially behind-themeter-storage (BTMS), have emerged as a potential candidate. BTMS plays a vital role in the grid storage sector and supports high power charging for EVs. However, the potential of thermal runaway and associated safety concerns in the batteries can hamper their widespread adoption. In this work, we provide a solution for a fast and controllable discharge of a cell that was identified as a stressful/faulty, in the battery pack, and fast circuit breaking leveraging the Solid-State Circuit Breaker (SSCB) technology which provides active control over the cell connection as opposed to conventional passive solutions. Testing on the simulation platform successfully validated the concept, demonstrating its efficacy. Controlled discharge testing with 20Ah LiFePO4 Lithium Iron Phosphate (LFP) cells from 1C-10C current rate on the hardware prototype corroborated simulation results, demonstrating design feasibility and providing essential data for its performance and thermal characteristics, while also revealing limitations that inform areas for further optimization.

33 ADVANCED PROPULSION SYSTEMS↗

Instability Issue of Paralleled Dies in an SiC Power Module in Solid-State Circuit Breaker Applications

Paralleled dies in a power module could have instability issues during high current switching transients. Here, the instability is caused by the differential-mode oscillation among paralleled MOSFETs. Conventional analyses of paralleled MOSFETs’ stability are normally limited to a single operating point, which ignores the influences of the switching trajectory and nonlinear device parameters on stability. This article reveals that the switching trajectory can significantly influence parallel stability. The analysis is improved by solving eigenvalues of state-space modeling system matrices of all operating points that the switching trajectory goes through considering nonlinear device parameters. Higher voltage and current stresses result in greater real parts of complex eigenvalues, which explains why the paralleled MOSFETs are more unstable with higher voltage and current stresses. To improve stability in solid-state circuit breaker applications, we propose a method to manipulate the switching trajectory to avoid the unstable region where the conventional hard switching trajectory normally goes through. Experimental results show that the turn- off current capability can be increased from ~five times of rated current with the gate oscillation using the conventional turn- off trajectory to ~ten times of rated current without the gate oscillation using the optimal turn- off trajectory.

42 ENGINEERING↗