Search NASA⌕ Search

SEARCH · Search NASA

Results for “circulating current control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

On the status of V/STOL flight

Basic principles relating to the accomplishment of V/STOL flight are reviewed as they pertain to current prototype developments. Particular consideration is given to the jet flap, flow augmentation and circulation control separately and in combination. Configurations as the augmentor wing, upper-surface blown flaps, externally blown flaps and the circulation-controlled rotor are also examined.

Mccormick, B. W.↗

Estimation of the processes controlling variability in phytoplankton pigment distributions on the southeastern U.S. continental shelf

Five coastal-zone-color-scanner images from the southeastern U.S. continental shelf are combined with concurrent moored current meter measurements to assess the processes controlling the variability in chlorophyll concentration and distribution in this region. An equation governing the space and time distribution of a nonconservative quantity such as chlorophyll is used in the calculations. The terms of the equation, estimated from observations, show that advective, diffusive, and local processes contribute to the plankton distributions and vary with time and location. The results from this calculation are compared with similar results obtained using a numerical physical-biological model with circulation fields derived from an optimal interpolation of the current meter observations and it is concluded that the two approaches produce different estimates of the processes controlling phytoplankton variability.

Mcclain, Charles R.↗

Exploiting the Temperature Dependence of Magnetic Susceptibility to Control Convection in Fundamental Studies of Solidification Phenomena

It is well known that convection is a dominant mass transport mechanism when materials are solidified on Earth's surface. This convection is caused by gradients in density (and therefore gravitational force) that are brought about by gradients in temperature, composition or both. Diffusion of solute is therefore dwarfed by convection and the study of fundamental parameters, such as dendrite tip shape and growth velocity in the absence of convection is nearly impossible. Significant experimental work has therefore been carried out in orbiting laboratories with the intent of minimizing convection by minimizing gravity. One of the best known experiments of this kind is the Isothermal Dendritic Growth Experiment (IDGE), supported by NASA. Naturally such experiments are costly and one objective of the present investigation is to develop an experimental method whereby convection can be- halted, in solidification and other experiments, on the surface. A second objective is to use the method to minimize convection resulting from the residual accelerations suffered by experiments in microgravity. The method to be used to minimize convection relies on the dependence of the magnetic susceptibility of a fluid on temperature or composition (whichever is driving convection). All materials experience a force when placed in a magnetic field gradient. The direction and magnitude of that force depend on the magnetic susceptibility of the material. Consequently the force will vary if the susceptibility varies with temperature or composition. With a magnetic field gradient in the right direction (typically upward) and of the right magnitude, this variation in the magnetic force can be made to exactly cancel the variation in the gravitational force. Expressed another way, normal buoyancy is exactly countered by a "magnetic buoyancy". To demonstrate the principle, a solution of MnC12 in water has been used. First the variation of the susceptibility of this paramagnetic solution with temperature and concentration was measured. Then a "cell", containing this solution and 50mm long by 15mm high by 155mm wide, was placed in a superconducting magnet at Marshall Space Flight Center. The magnetic field was measured at various positions within the bore of the magnet using a Hall effect probe. In this way, a position was found where the magnetic field gradient was predominantly upward; the magnitude of the gradient could then be adjusted by adjusting the current of the magnet. The ends of the cell consisted of machined copper blocks maintained at controlled temperatures by circulating water from constant temperature baths. The walls of the cell were of rectangular section glass tubing so that the cell contents could be seen. Velocities arising from thermal gradients within the cell were measured by particle image velocimetry (PIV). Particles used for this purpose were silver-coated hollow glass spheres of micrometers diameter and nearly the same density as the solution. A central vertical plane of the cell was illuminated by a laser beam passing through a cylindrical lens. Digital images of the particles were captured on a CCD camera and fed to a computer so that frame-to-frame movements of particles traveling with the fluid were captured. These images were employed to compute velocity maps using commercial PIV software. In a typical experiment the cold end of the cell was maintained at 10C and the warm end at 30 C. With no current in the magnet, i.e.- with natural -convection allowed to occur, the fluid was observed to circulate with an average speed of approximately 0.3 millimeters per second. It was visually apparent that this circulation was diminished as the current was increased. At currents of approximately 20A the flow was halted, to within the precision of the PIV measurements. At yet higher currents the convection was reversed with the hotter solution sinking and the cooler solution rising. At 40A this reversed convection had speeds averaging 0.43 millimeters per second. The measurements of susceptibility and density allow an estimate of the field gradient necessary to halt convection in the experiment. That estimate was 7.8T (squared) per meter and the convection was observed to halt in the magnet at a current giving 7.21T (squared) per meter from the magnetic field measurements. Calculations of the flow have been carried out using the computational fluid dynamics software FLUENT and show good agreement with the measurements.

Seybert, C. D.↗

A Neural Network-Based Power Mismatch Elimination Strategy for Integrated Solar and ESS AC/DC Systems (MARS)

The multiport autonomous reconfigurable solar power plant (MARS) is a promising concept for the integration of photovoltaic (PV) and energy storage system (ESS) to the transmission ac grid and a high-voltage direct current (HVdc) link. The presence of PV and ESS in each arm of the MARS results in uneven distribution of active power among different submodules (SMs), thereby leading to unbalanced SM capacitor voltages and potentially compromising the system stability. Moreover, in the case of partial shadings, shaded PV SMs will suffer from decreased power injections causing power mismatch in the MARS system. To address this issue, a neural-network-based power mismatch elimination (NNPME) strategy is proposed in this article. The proposed NNPME strategy optimizes ESS usage and leverages both dc and ac circulating currents to facilitate power transfer among the SMs, arms, and phases of the MARS system. Simulation and control hardware-in-the-loop (cHIL) experiments demonstrate the effectiveness of the proposed NNPME strategy. Compared with the traditional approaches, the proposed NNPME strategy can significantly enhance system efficiency and ensure stable and continuous operation, even in the presence of uneven power distribution within the MARS system.

14 SOLAR ENERGY↗

MSATT: Mars Surface and Atmosphere Through Time

The papers published here are based on a workshop entitled "Mars: Past, Present, and Future: Results from the MSATT Program." MSATT (Mars Surface and Atmosphere Through Time) was the last of the Mars data analysis programs and functioned mainly through a series of focused workshops, the final one being held at the Lunar and Planetary Institute in Houston, Texas on November 15-17, 1993. The program began and ended with workshops that brought the entire MSATT community together. Here you will find papers that address the geology, mineralogy, and meteorology of Mars in an effort to assess how the surface and atmosphere of this fascinating planet have evolved over time. Could early Mars have been warmed by a brighter young sun instead of a massive greenhouse effect? Were glaciers and hydrological cycles part of Mars' relatively recent past, or was aeolian activity responsible for the putative glacial features? Do the SNCs come from a single source region, or is more than one site involved? And what really are the properties of Martian soils and what do they tell us about the weathering environment? Clearly, these are difficult questions, but progress toward answers can be found in this issue. Also contained in this issue are a mix of theoretical and observational papers that deal with the general circulation of the current atmosphere, the factors that drive it (dust properties), and the role it plays in controlling the current climate system.

Source record↗

Optical Injection Locking of a VCSEL in an OEO

Optical injection locking has been demonstrated to be effective as a means of stabilizing the wavelength of light emitted by a vertical-cavity surface- emitting laser (VCSEL) that is an active element in the frequency-control loop of an opto-electronic oscillator (OEO) designed to implement an atomic clock based on an electromagnetically- induced-transparency resonance. This particular optical-injection- locking scheme is expected to enable the development of small, low-power, high-stability atomic clocks that would be suitable for use in applications involving precise navigation and/or communication. In one essential aspect of operation of an OEO of the type described above, a microwave modulation signal is coupled into the VCSEL. Heretofore, it has been well known that the wavelength of light emitted by a VCSEL depends on its temperature and drive current, necessitating thorough stabilization of these operational parameters. Recently, it was discovered that the wavelength also depends on the microwave power coupled into the VCSEL. Inasmuch as the microwave power circulating in the frequency-control loop is a dynamic frequency-control variable (and, hence, cannot be stabilized), there arises a need for another means of stabilizing the wavelength. The present optical-injection-locking scheme satisfies the need for a means to stabilize the wavelength against microwave- power fluctuations. It is also expected to afford stabilization against temperature and current fluctuations. In an experiment performed to demonstrate this scheme, wavelength locking was observed when about 200 W of the output power of a commercial tunable diode laser was injected into a commercial VCSEL, designed to operate in the wavelength range of 795+/-3 nm, that was generating about 200 microW of optical power. (The use of relatively high injection power levels is a usual practice in injection locking of VCSELs.)

Strekalov, Dmitry↗

Paralleling of LLC Resonant Converters

The LLC resonant converter is a popular, variable switching frequency DC-DC converter that may be controlled using two methods: charge and frequency control. In this paper, the application of LLC resonant converters to input-parallel, output-parallel system is studied. In this respect, the models of output-port I-V characteristics and small-signal output impedance of the charge controlled LLC converter are proposed. In addition, a mathematical framework is developed for droop-based paralleled DC-DC systems. Here, it distinctly identifies the output DC voltage and circulating current modes of stability, even in systems comprising of non-identical converters.

42 ENGINEERING↗

Understanding the Formation and Evolution of Water Ice Clouds in the Hellas Basin During NH Summer on Mars

Water in the atmosphere of Mars moves between the northern and southern hemispheres seasonally, with north-to-south transport during northern hemisphere (NH) summer and south-to-north transport during southern hemisphere (SH) summer. Understanding the processes that control this seasonal transport of water is critical for understanding the current climate of Mars. Because water ice clouds both track and influence atmospheric circulations on a range of spatial scales, investigations about when and why clouds form enhance our knowledge of the water cycle as a whole. We focus here on a population of clouds that has recently been observed by the MARs Color Imager (MARCI) instrument on the Mars Reconnaissance Orbiter (MRO) to persist in the Hellas Basin throughout the majority of NH summer. Centered at 321 nm, Band 7 of the MARCI instrument is ideally suited for mapping water ice clouds on Mars because water ice is bright in the UV. It is notable that the clouds observed by MARCI in Hellas during NH summer are not as easily observed by the Thermal Emission Spectrometer (TES) on Mars Global Surveyor (MGS), which observes in the IR. We use a Global Climate Model (GCM) to investigate the dynamical mechanisms that control the formation and evolution of Hellas water ice clouds.

water ice clouds↗

Measurements of the response of transport aircraft ceiling panels to fuel pool fires

Tests were performed to characterize the responses of various aircraft ceiling panel configurations to a simulated post-crash fire. Attention was given to one currently used and four new ceiling configurations exposed to a fuel pool fire in a circulated air enclosure. The tests were controlled to accurately represent conditions in a real fire. The panels were constructed of fiberglass-epoxy, graphite-phenolic resin, fiberglass-phenolic resin, Kevlar-epoxy, and Kevlar-phenolic resin materials. The phenolic resin-backed sheets performed the best under the circumstances, except when combined with Kevlar, which became porous when charred.

Bankston, C. P.↗

CFD Analysis of Circulation Control Airfoils Using Fluent

In an effort to validate computational fluid dynamics procedures for calculating flows around circulation control airfoils, the commercial flow solver FLUENT was utilized to study the flow around a general aviation circulation control airfoil. The results were compared to experimental and computational fluid dynamics results conducted at the NASA Langley Research Center. The current effort was conducted in three stages: 1. A comparison of the results for free-air conditions to those from experiments. 2. A study of wind-tunnel wall effects. and 3. A study of the stagnation-point behavior.

McGowan, Gregory↗

Flow Boiling and Condensation Experiment Flight Hardware Development

The Flow Boiling and Condensation Experiment (FBCE) to be manifested on the International Space Station (ISS) consists of a fluid system and the associated electronics to provide for conditioning the test fluid (normal-PerFluorohexane or nPFH-C6F14) to the proper thermodynamic state prior to entering a test module, which can be interchangeable based on the science objectives. Two separate test modules have been manufactured for the FBCE, the Flow Boiling Module (FBM), which investigates flow boiling for a subcooled liquid, saturated liquid, or two phase mixture, and the Condensation Module Heat Transfer (CM-HT), which investigates condensation of a flowing saturated or superheated vapor. The test fluid heating is accomplished using the Bulk Heater Module (BHM), which heats the fluid to various states based on the demands of the currently installed test module. ISS Internal Thermal Control System (ITCS) water is utilized to cool the test fluid prior to entering the circulation pump, and is also utilized for cooling for condensation in CM-HT, for cooling of a camera in FBM. An adjustable pressure bellows-type accumulator is used to set the pressure at the inlet of the test section, but does not provide active pressure control during testing. The flow of the test fluid is achieved using a gear pump controlled by a coriolis flow meter, which also provides the flow rate measurement. Flow rates for the ITCS water loops are measured and controlled using coriolis flow meters with directly controlled proportional valves. During execution of FBCE operations, the FBM is scheduled to collect data for three months before being exchanged with CM-HT for another three month data collection run. In this work, we present the development of the flight hardware, the associated challenges experienced during the development such as packaging flight system hardware, and the lessons learned in overcoming the encountered challenges.

Guzik, Monica C.↗

Spatial and temporal variability of tritium in precipitation within South Africa and it's bearing on hydrological studies

Tritium, the radioactive isotope of hydrogen, has been used to understand groundwater recharge processes for decades. The current variation of tritium in the atmosphere is largely attributed to stratospheric production and fall out rates as well as global circulation phenomena controlling the hydrological cycle. Global controls on the variability in atmospheric tritium activity are poorly suited to explain local variation and tritium activities in precipitation are often assumed to be uniform over both local and regional catchments and watersheds. This assumption can result in both over and under estimation of modern recharge within an aquifer when using tritium as the recharge proxy. In order to minimize the inherent prediction residuals associated with tritium based recharge investigations, the variability of tritium in precipitation was modelled from 127 spatial precipitation samples taken over a two year period, combined with a 76 precipitation sample group-set taken over a one year period in a single location. Precipitation events were traced backward in time, from the point of collection, using HYSPLIT modelling to ascertain the origins of moisture content as well as the altitudes of moisture origin reached along the particle track. Tritium activities, collected over a one year period in Paarl, range from 0.45 to 4.16 TU and have a mean of 1.59 TU. Spatial storm events in the Western Cape in 2017 and 2018 had a range from 0 to 2.2 and 0.37 to 3.27 TU, respectively, with mean activities of 1.18 (n = 34) and 1.25 TU (n = 32). Both storm events had similar tritium variability (σ = 0.5 n = 35 and 0.48 n = 32). Regional precipitation events had the largest range of tritium activities (0.55–12.2 TU). Although not all tritium activities can be explained by interrogating the water mass origin, this study suggests that approximately 90% of events can be completely or partially attributed to the origin of the water mass. The variability of tritium, both spatially and temporally, was higher than expected, confirming that when uniform tritium inputs are used, the groundwater system would provide inaccurate modern recharge estimates. Higher spatial resolution of tritium variation in precipitation for a particular region will improve our ability to relate tritium activities in groundwater to local precipitation.

54 ENVIRONMENTAL SCIENCES↗

Open Circuit Switch Fault Management Method of a Multi-Phase Synchronous Buck Converter for EV Charging Application

Multi-phase synchronous buck converter (MSBC) is becoming popular for the electric vehicle (EV) charging application because of its higher efficiency, smaller passive component sizes, bidirectional power flow, and output current ripple reduction through interleaving. This converter also provides higher reliability than the traditional single phase converter since its modular structure enables fault tolerant operation. Fault management in the converter requires the detection of switch fault, shut down of the faulty phase, and reconfiguration of the PWM signals for the healthy phases to avoid circulating current and high output current ripple. In addition, it is desirable that the fault management method can be implemented using the micro-controller unit (MCU) or digital signal processor (DSP), which are widely used to control power converters. This paper presents a fault management method for detecting switch faults and reconfiguring healthy phases using a DSP. The method is validated through simulations and experiments using a commercial off-the-shelf power stack.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cell Separations in Microgravity and Development of a Space Bioreactor

A bioreactor optimized for operations in space is now being developed. The current research is focused on determining the optimum cell-bead ratios, medium content and proper maintenance conditions required to keep living cell specimens alive and healthy for the entire flight. The bioreactor development project has recently added a microprocessor/computer to the JSC prototype for control and data analysis. Appropriate new technology is being combined with the current bioreactor designs and tested to determine what specific features must be included in the fabrication of a bioreactor designed to operate for STS demonstration tests. Considerations include: (1) circulation and resupply of culture media; (2) sensors required to monitor temperature, cell growth, mass transport, and oxygen consumption; and (3) inflight control of shear stress on cells, gas transfer in microgravity, diffusion, and intracellular transport. These data and results from the JSC prototype bioreactor test will be used for the design and construction of a small space bioreactor for the Orbiter middeck.

Morrison, D. R.↗

Investigating Mars South Residual CO2 Cap with a Global Climate Model

The CO2 cycle is one of the three controlling climate cycles on Mars. One aspect of the CO2 cycle that is not yet fully understood is the existence of a residual CO2 ice cap that is offset from the south pole. Previous investigations suggest that the atmosphere may control the placement of the south residual cap (e.g., Colaprete et al., 2005). These investigations show that topographically forced stationary eddies in the south during southern hemisphere winter produce colder atmospheric temperatures and increased CO2 snowfall over the hemisphere where the residual cap resides. Since precipitated CO2 ice produces higher surface albedos than directly deposited CO2 ice, it is plausible that CO2 snowfall resulting from the zonally asymmetric atmospheric circulation produces surface ice albedos high enough to maintain a residual cap only in one hemisphere. The goal of the current work is to further evaluate Colaprete et al.'s hypothesis by investigating model-predicted seasonally varying snowfall patterns in the southern polar region and the atmospheric circulation components that control them.

CO2 cycle↗

A mathematical and experimental simulation of the hematological response to weightlessness

A mathematical model of erythropoiesis control was used to simulate the effects of bedrest and zero-g on the circulating red cell mass. The model incorporates the best current understanding of the dynamics of red cell production and destruction and the associated feedback regulation. Specifically studied were the hemodynamic responses of a 28-day bedrest study devised to simulate Skylab experience. The results support the hypothesis that red cell loss during supine bedrest is a normal physiological feedback process in response to hemoconcentration enhanced tissue oxygenation and suppression of red cell production. Model simulation suggested the possibilities that this period was marked by some combination of increased oxygen-hemoglobin affinity, small reduction in mean red cell life span, ineffective erythropoiesis, or abnormal reticulocytosis.

Kimzey, S. L.↗

Assimilation of Stratospheric Meteorological and Constituent Observations: A Review

This talk reviews the assimilation of meteorological and constituent observations of the stratosphere. The first efforts to assimilate observations into stratospheric models were during the early 1980s, and a number of research studies followed during the next decade. Since the launch of the Upper Atmospheric Research Satellite (UARS) in 1991, model-assimilated data sets of the stratospheric meteorological state have been routinely available. These assimilated data sets were critical in bringing together observations from the different instruments on UARS as well as linking UARS observations to measurements from other platforms. Using trajectory-mapping techniques, meteorological assimilation analyses are, now, widely used in the analysis of constituent observations and have increased the level of quantitative study of stratospheric chemistry and transport. During the 1990s the use of winds and temperatures from assimilated data sets became standard for offline chemistry and transport modeling. variability in middle latitudes. The transport experiments, however, reveal a set of shortcomings that become obvious as systematic errors are integrated over time. Generally, the tropics are not well represented, mixing between the tropics and middle latitudes is overestimated, and the residual circulation is not accurate. These shortcomings reveal underlying fundamental challenges related to bias and noise. Current studies using model simulation and data assimilation in controlled experimentation are highlighting the issues that must be addressed if assimilated data sets are to be convincingly used to study interannual variability and decadal change. observations. The primary focus has been on stratospheric ozone, but there are efforts that investigate a suite of reactive chemical constituents. Recent progress in ozone assimilation shows the potential of assimilation to contribute to the validation of ozone observations and, ultimately, the retrieval of ozone profiles from space-based radiance measurements. Assimilated data sets provide accurate analyses of synoptic and planetary Scale At the same time, stratospheric assimilation is evolving to include constituent

Rood, Richard B.↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗