Search NASA⌕ Search

SEARCH · Search NASA

Results for “circulator pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Solar hot water system installed at Days Inn Motel, Jacksonville, Florida

The solar system was designed to provide 65 percent of the hot water demand. Water in the liquid flat plate collector (900 square feet) system automatically drains into the 1000 gallon lined and vented steel storage tank when the pump is not running. Heat is transferred from storage to Domestic Hot Water (DHW) tanks through a tube and shell heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up DHW standby losses. All pumps are controlled by differential temperature.

Source record↗

Influence of building heat distribution temperatures on the energy performance and sizing of 5th generation district heating and cooling networks

This paper investigates the energy performance and sizing criteria of 5th generation district heating and cooling (5GDHC) networks as a function of the heat distribution temperature in the building systems connected to the district network. An energy simulation model of a 5GDHC network was developed in Modelica for a case study located in Denmark. Calculations were carried out for four different building heating systems. Simulation results show that reducing the heat distribution temperatures from 70 °C to 23 °C leads to around 40% annual electric energy savings (from 10.4 kWh/m 2 to 6.2 kWh/m 2 ) for the operation of the heat pumps. Heat distribution temperatures of 23 °C cause higher water mass flow rates through the network, leading to annual electric energy consumption for the circulation pumps that are almost doubled (from 0.16 kWh/m 2 to 0.3 kWh/m 2 ) compared to the reference case at 70 °C. Furthermore, the paper discusses how the results obtained from the Danish case study can be generalized and applied to other cases using a simplified mathematical approach. In conclusion, it is found that about 1.5% of electric energy savings can be achieved for each temperature degree reduction in the heat distribution system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Efficient Annual-Performance Model of a Geothermal Network for Improved System Design, Operation, and Control: Preprint

Geothermal district energy systems (DES), and specifically geothermal networks, provide a viable solution for decarbonizing residential and commercial heating and cooling loads. District energy systems of all kinds enable a thermal resource with a relatively high capital cost (such as a geothermal borehole field) to be shared among a large number of users. While district heating and cooling has been studied for many years, geothermal networks, fifth generation DES that utilize water-source heat pumps and an ambient temperature loop to meet heating and cooling loads, have not been implemented extensively and thus require additional technical and economic optimization to obtain maximum benefits. This paper presents a newly developed reduced-order model that captures the flow of energy within the network, including the commercial and residential users' electrical usage, at an hourly rate over a year. The model includes building loads, heat pumps, borehole fields, and auxiliary heat/cool input, all connected with an ambient-temperature thermal loop model. In the model, operational control is possible for the borehole fields, circulation pump, and auxiliary system. For a given system, the model can output the complete state parameters for each component, the thermal loop, and the collective system, such as flow rate over time, average thermal loop temperature over time, and total electricity usage. The model can also be used to optimize the system control for maximizing system efficiency or minimizing system operational cost. For example, one initial assessment of the borehole controller for an example system showed that a controller with on/off operation of the borehole field reduces annual electrical usage by 33%, compared with continuous operation mode. Hence, the model can assist in optimizing a given system's operation to get the most value out of a geothermal network installation. Future work will consider the model's application to a demonstration project, including the model validation against operational data and system operation optimization.

ambient-temperature loop↗

Tidal Energy System for On-Shore Power Generation (Final Technical Report)

Addressing the urgent need to develop LCOE competitive renewable energy solutions for US energy security and to replace fossil-fuel generation with the associated benefits to environment impacts including a reduction in CO2 emissions, this Project focused on the advantages of using hydraulic energy transfer (HET) in large-scale Marine Hydrokinetic (MHK) systems for harvesting off-shore tidal energy in US waters. A recent DOE resource assessment, identifies water power resources have a potential to meet 15% of the US electric supply by 2030, with MHK technologies being a major component. The work covered a TRL-4 laboratory proof-in-concept demonstration plus modeling of a 15MW full scale system based on an approach patented by NASA-JPL, in which submerged high-ratio gearboxes and electrical generators in conventional MHK turbine systems are replaced by a submerged hydraulic radial pump coupled to on-shore hydraulic motors driving a generator. The advantages are; first, the mean-time-between-failure (MTBF), or maintenance, can be extended from approximately 1 to 5 years and second, the range of tidal flow speeds which can be efficiently harvested can be extended beyond that of a conventional submerged generator. The approach uses scalable, commercial-off-the-shelf (COTS) components, facilitating scale-up and commercialization. All the objectives of the Project have been successfully met (1) A TRL4 system was designed, constructed and tested. It simulates a tidal energy turbine, with a 2-m diameter blade in up to a 2.9 m/sec flow. The system consists of a drive motor assembly providing appropriate torque and RPM, attached to a radial piston pump. The pump circulates pressurized, environmentally-friendly, HEES hydraulic fluid in a closed loop to an axial piston motor which drives an electrical generator, with a resistive load. The performance of the components, subsystems and system were evaluated during simulated tidal cycles. The pump is contained in a tank for immersion testing. The COTS pump and motor were selected to scale to MW size and were oversized for the TRL-4 demonstration, operating at only 1-6% of rated values. Nevertheless, in for 2-18 kW drive power, in agreement with manufacturer performance data, we measured efficiencies of 85-90% and 75-80% for the pump and motor, respectively. These efficiencies being 95-96% at higher operating powers. (2) Two follow-on paths were identified. In both cases conventional turbine systems can be modified, replacing existing gear box and generator with a hydraulic pump and on-shore components. On a conventional path, a TRL5/6 15kW turbine system can be engineered and tested on a barge at an existing site in Maine. Alternatively, on an accelerated path, a TRL-8 100kW system can be engineered and tested by modifying a team member's existing MHK turbines, with barge and grid-connected test sites in-place. On both paths the work can be expedited and cost effective by reusing TRL-4 components, modifying existing turbines and using established test sites. (3) Sizing, performance modeling and costing of a scaled 15MW system, suitable for operation in Maine's Western Passage, was performed. COTS components are identified and the performance projections are favorable. The estimated LCOE is comparable to wind generation with peak production at high demand times. (4) We determined that a similar HET approach can be extended to on-shore and off-shore wind turbine systems. These are very large energy resources which can be addressed in parallel for even great National benefit. (5) Preliminary results on this project were presented at two International Conferences on renewable energy in 2012, providing a timely dissemination of information. We have thus demonstrated a proof-in-concept of a novel, tidal HET system that eliminates all submerged gears and electronics to improve reliability. Hydraulic pump efficiencies of 90% have been confirmed in simulated tidal flows between 1 and 3 m/s, and at only 1-6% of rated power. Total system efficiencies have also been modeled, up to MW-scale, for tidal, and wind, systems. Projected efficiencies are between 81% (full rated flow) and 86% (1/3 rated flow). This high efficiency in a wide operating range compares favorably with conventional systems having a performance range of 87% (full rated flow) to 0% (1/3 rated flow) efficiency. An accelerated path to commercialization is identified, leveraging conventional MHK system technology and COTS components to meet the urgent need for renewable energy generation.

16 TIDAL AND WAVE POWER↗

Heuristic explanation of journal bearing instability

A fluid-filled journal bearing is viewed as a powerful pump circulating fluid around the annular space between the journal and the bearing. A small whirling motion of the journal generates a wave of thickness variation progressing around the channel. The hypothesis that the fluid flow drives the whirl whenever the mean of the pumped fluid velocity is greater than the peripheral speed of the thickness variation wave is discussed and compared with other simple explanations of journal bearing instability. It is shown that for non-cavitation long bearings the hypothesis predicts instability onset correctly for unloaded bearings but gradually overpredicts the onset speed as the load is increased.

Crandall, S. H.↗

Pumped two-phase heat transfer loop

A pumped loop two-phase heat transfer system, operating at a nearly constant temperature throughout, includes several independently operating grooved capillary heat exchanger plates supplied with working fluid through independent flow modulation valves connected to a liquid supply line, a vapor line for collecting vapor from the heat exchangers, a condenser between the vapor and the liquid lines, and a fluid circulating pump between the condenser and the heat exchangers.

Edelstein, Fred↗

Pumped two-phase heat transfer loop

A pumped loop two-phase heat transfer system, operating at a nearly constant temperature throughout, includes a plurality of independently operating grooved capillary heat exchanger plates supplied with working fluid through independent flow modulation valves connected to a liquid supply line, a vapor line for collecting vapor from the heat exchangers, a condenser between the vapor and the liquid lines, and a fluid circulating pump between the condenser and the heat exchangers.

Edelstein, Fred↗

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo: Preprint

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. Using GHEDesigner, a lookup table was created to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on agent energy bills. This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of different costing and pricing future scenarios. While the code is still under development and nationwide simulations are ongoing, initial results for two states are provided. Future work includes expanding the module to consider mixed residential and commercial districts and considering multiple costing scenarios.

ambient temperature loop↗

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. A lookup table was created using GHEDesigner to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on energy bills for building owners (agents). This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of future cost and price scenarios. Initial results for statewide analysis (for Vermont) and nationwide (for United States) are provided. Future work includes expanding the module to consider mixed residential and commercial districts as well as evaluating multiple cost scenarios.

ambient-temperature loop↗

Risk Management of NPP Incidents

A diagnostic model for managing the risk of NPP incidents attending different irregularities of equipment operation is examined for the example of the oil delivery system of the main circulation pump. The model includes the construction of a graph of the operation of the oil system and ranking in order to obtain indices of priority for monitoring information flow that reflect the actuation probability of each form of protection. The results of the analysis can used as input data for predicting the duration of a stable state of a technological system in the course of operation on the basis of stochastic extrapolation of the parameters by means of single-channel queuing systems with finite storage – technological protection and blocking.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Algorithms and Experience with Prediction of Technical Operating Failures in Nuclear Power Plant Equipment

The development of algorithms for the prediction of technological operating failure of nuclear power plant equipment based on stochastic extrapolation of the values of technical parameters is discussed. The algorithms are tested on real archived data on the operation of the oil circulation system of the main circulating pumps in a power generating unit at a nuclear power plant.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dependence of electric strength on the ambient temperature

At present, the volume concentration of electronic components in their miniaturization to different types of microchips and increasing their performance raises the problem of cooling such elements due to the increasing density of heat flow of heat loss. Compliance with safe operating temperature of active semiconductor element is very closely related to the reliability and durability not only components, but also the entire device. Often it is also necessary to electrically isolate the unit from the side of the cooler air. Cooling demand by natural convection is typical for applications with high operating reliability. To the reliability of the system for removing heat loss increased, it is necessary to minimize need to use the mechanically or electrically powered elements, such as circulation pumps or fans. Experience to date with applications of heat pipe in specific systems appears to be the most appropriate method of cooling.

42 ENGINEERING↗

Lessons from commissioning and operations of the ICARUS cryogenic system at Fermilab

Results and lessons from three years of commissioning and operations of the cryogenic and purificationsystems of the ICARUS neutrino detector installed at the Fermilab are described. The detector uses liquid argon stored in two separate containers of about 275 m 3 each. The liquid argon must be kept in very stable thermal conditions, and the contamination of electronegative impurities must be consistently kept at small fractions of parts per billion. Since its fill in early 2020, the detector has been commissioned and then operated in neutrino beams at Fermilab for the search of sterile neutrinos and measurements of neutrino-argon cross sections. The results of operating the cryogenic and purification systems and lessons learned, including challenges in reaching the design electron lifetime in argon bath, operating and servicing liquid nitrogen and argon circulation pumps, argon condensers and purifiers, are described. Plans for future operations and list of recommendations are presented.

43 PARTICLE ACCELERATORS↗

2012-13 Blue Room Low Enriched Uranium Sample Irradiation, Associated Gas Handling System, and Subsequent Separation Chemistry

An irradiation experiment was designed for the production of 100 mCi of medical isotope Mo-99 from a Low Enriched Uranium (LEU) solution. 300 mL of 150 gU/L LEU sulfate solution (pH1) was prepared and irradiated at the LANSCE Blue Room facility. The apparatus designed for the irradiation included a gas handling system, in which safe operation could be controlled by monitoring change in gas pressure. The gas handling system also contained a hydrogen oxygen recombiner, to recombine the gases generated through radiolysis of water, and an iodine trap, primarily for I-131. Pressure transients were observed during irradiation, which could be controlled by increasing the flow rate of the circulating pump. After irradiation the LEU solution was transferred to a hot cell facility for subsequent Mo-99 recovery using a titania column separation process, with samples also subsequently shipped to a radiochemical laboratory for further analysis. Gamma spectroscopy analysis revealed that ca. 70 mCi of Mo-99 was present at end of beam, in good agreement with the predicted value when actual beam history was included into the calculation. There was 80-85 % recovery of Mo-99 through a titania column separation, excluding losses through radioactive decay. The % Mo-99 recovery was lower than observed previously for the 1 mCi Mo-99 production (Target 4) experiments undertaken at LANL using the same separation apparatus, with on this occasion evidence of lower oxidation state molybdenum remaining irreversibly bound to the titania column. Subsequent postmortem analysis of the Blue room apparatus revealed that there had been no leaks in the gas handling system, the hydrogen and oxygen recombination appeared to work efficiently, and recovery of irradiated uranium trapped in the system allowed for >99% uranium mass balance.

07 ISOTOPE AND RADIATION SOURCES↗

A Very High Temperature Lead Cooled Microreactor Concept using Advanced Materials and Thermophotovoltaics Direct Energy Conversion Technology

Recently, significant advances have been made in designing high-temperature capable nuclear fuels. In parallel, important advances have occurred in design of nanophotonic structures (coatings) with ability to shape the frequencies of light being emitted from hot surfaces. In this project, we bring these materials advances together into a design for a new direct conversion nuclear powered system with high thermodynamic efficiency, inherent safety, and unprecedented reduction in size and weight relative to current designs. The concept involves using the heat generated from nuclear fission to raise the temperature of a selective thermal emitter to >800°C. The selective emitter shifts the normal broad brand emissions of light from its hot surface into the correct near- and mid-IR bands that produce electricity with inexpensive photovoltaic cells. We have designed a new annular flow Lead Fast Reactor (LFR) that minimizes overall reactor/power conversion footprint. The results indicate that the overall microreactor/power-system design offers a 2X reduction in size over existing technology that is based on the sCO 2 reverse compression Brayton cycle. Additionally, the only moving part in our design is a circulation pump to cool the PVT panels.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Akiachak Energy Efficiency Retrofit Project

The goal of the project is to reduce the overall energy use of the Akiachak Native Community (ANC) by implementing energy efficiency measures in five high-use Tribal buildings. This project will have the following outcomes: Projected annual energy savings of $17,369; projected annual reduction in fuel oil #1 of 1,200 gallons and electricity of 17,751 kWh; annual reduction in carbon dioxide emissions of approximately 60,340 pounds/year. ANC will install energy efficiency measures in the Laundry, Tribal Indian Reorganization Act (IRA) Office, Clinic, Daycare, and Police Station. ANC obtained energy audits on these buildings in 2018, and this project will implement high-payback recommendations such as replacing lighting with LEDs, installing setback thermostats and occupancy sensors, replacing furnaces with more efficient models, replacing the circulation pumps with variable speed ones, air tightening, and adding insulation. Buildings will see energy cost reductions from 15% to 40%. These retrofits will help build ANC’s long-term vision for sustainable energy usage and address the first goal of the Tribal IRA Council’s Energy Efficiency and Conservation Strategy, to “create and maintain functionally appropriate, sustainable, accessible, high quality tribal infrastructure and facilities.” ANC intends to replicate this project by using the resulting energy savings to address audit recommendations in other buildings as well as to demonstrate the value of energy efficiency to community members. Other outcomes will include an increase in community resiliency, reduced dependence on outside shipments of fuel oil, training for maintenance staff, and no-touch control of building appliances to reduce transmission of diseases such as COVID-19.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transistor package for high pressure applications

TO63 transistor package can operate in hydraulic oil ar pressures of 200 psi or greater without leakage failure if it is reinforced by alumina disk brazed to cap and terminals. This inexpensive modification has been used successfully on power transistors in hydraulic circulating-pump assemblies for Space Shuttle orbiter and should be effective in other pressurized environments, such as in oil exploration equipment.

Zantos, P. J.↗

Solar hot water system installed at Quality Inn, Key West, Florida

The solar energy hot water system installed in the Quality Inn, Key West, Florida, which consists of four buildings is described. Three buildings are low-rise, two-story buildings containing 100 rooms. The fourth is a four-story building with 48 rooms. The solar system was designed to provide approximately 50 percent of the energy required for the domestic hot water system. The solar system consists of approximately 1400 square feet of flat plate collector, two 500 gallon storage tanks, a circulating pump, and a controller. Operation of the system was begun in April 1978, and has continued to date with only three minor interruptions for pump repair. In the first year of operation, it was determined that the use of the solar facility resulted in forty percent fuel savings.

Source record↗