SEARCH · Search NASA
Results for “clock”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Kalanchoë PPC1 Is Essential for Crassulacean Acid Metabolism and the Regulation of Core Circadian Clock and Guard Cell Signaling Genes
Not provided.
A Novel Triple Inverter Design for CMOS Clocks and Oscillators.
Abstract not provided.
The CAKE Clocking and the Trapezoidal Clocking Schemes: Principles and Demo Tests
Abstract Not Provided
Epithelial cell adhesion molecule expression in hepatic stem/progenitor cells is controlled by the molecular clock system
Highlights: • We investigated clock gene effects on EpCAM-positive cell induction in hepatitis. • Hepatitis in CLOCK mutant mice was severe compared with wild-type mice. • CLOCK regulated expression of LEF, which regulated EpCAM expression. • CLOCK was important for healing hepatitis. The circadian rhythm, which regulates various body functions, is transcriptionally controlled by a series of clock gene clusters. The clock genes are related to the pathology of various kinds of diseases. Although there is evidence of serious sleep disorders in patients with chronic hepatitis, the liver regeneration mechanism under chronic hepatitis conditions and its association with the clock genes are not clear. In this study, the influence of the circadian locomotor output cycles kaput (CLOCK), which is one of the clock genes, on a 3,5-diethoxycarbonyl-1,4-dihydrocollidine (DDC)-induced hepatitis animal model was investigated. The appearance of potential hepatic stem-like cells (epithelial cell adhesion molecule [EpCAM]-positive cells) is an initial critical step in liver regeneration during chronic inflammation. The results showed a considerable number of hepatic EpCAM-positive cells in the wild-type (WT) mice 1 week after the DDC feeding. However, the number of EpCAM-positive cells in the Clock-mutant (Clk/Clk) mice decreased, and their hepatitis was worse compared with the WT mice. In addition, the expression of Epcam mRNA, which is a functional marker of potential hepatic stem-like cells, was controlled by LEF1, which was regulated by CLOCK. The results of this study will facilitate the elucidation of the liver regeneration mechanisms, including those at the molecular level, and may assist in the development of new treatment modalities in the future.
Epigenetic drift underlies epigenetic clock signals, but displays distinct responses to lifespan interventions, development, and cellular dedifferentiation
Changes in DNA methylation with age are observed across the tree of life. The stereotypical nature of these changes can be modeled to produce epigenetic clocks capable of predicting chronological age with unprecedented accuracy. Despite the predictive ability of epigenetic clocks and their utility as biomarkers in clinical applications, the underlying processes that produce clock signals are not fully resolved, which limits their interpretability. Here, we develop a computational approach to spatially resolve the within read variability or “disorder” in DNA methylation patterns and test if age-associated changes in DNA methylation disorder underlie signals comprising epigenetic clocks. We find that epigenetic clock loci are enriched in regions that both accumulate and lose disorder with age, suggesting a link between DNA methylation disorder and epigenetic clocks. We then develop epigenetic clocks that are based on regional disorder of DNA methylation patterns and compare their performance to other epigenetic clocks by investigating the influences of development, lifespan interventions, and cellular dedifferentiation. We identify common responses as well as critical differences between canonical epigenetic clocks and those based on regional disorder, demonstrating a fundamental decoupling of epigenetic aging processes. Collectively, we identify key linkages between epigenetic disorder and epigenetic clocks and demonstrate the multifaceted nature of epigenetic aging in which stochastic processes occurring at non-random loci produce predictable outcomes.
Lipoic acid entrains the hepatic circadian clock and lipid metabolic proteins that have been desynchronized with advanced age
Highlights: • 24 month old rats were supplemented with 0.2% lipoic acid in the diet for 2 weeks. • Lipoic acid shifts phase of core circadian clock proteins. • Lipoic acid corrects age-induced desynchronized lipid metabolism rhythms. - Abstract: It is well established that lipid metabolism is controlled, in part, by circadian clocks. However, circadian clocks lose temporal precision with age and correlates with elevated incidence in dyslipidemia and metabolic syndrome in older adults. Because our lab has shown that lipoic acid (LA) improves lipid homeostasis in aged animals, we hypothesized that LA affects the circadian clock to achieve these results. We fed 24 month old male F344 rats a diet supplemented with 0.2% (w/w) LA for 2 weeks prior to sacrifice and quantified hepatic circadian clock protein levels and clock-controlled lipid metabolic enzymes. LA treatment caused a significant phase-shift in the expression patterns of the circadian clock proteins Period (Per) 2, Brain and Muscle Arnt-Like1 (BMAL1), and Reverse Erythroblastosis virus (Rev-erb) β without altering the amplitude of protein levels during the light phase of the day. LA also significantly altered the oscillatory patterns of clock-controlled proteins associated with lipid metabolism. The level of peroxisome proliferator-activated receptor (PPAR) α was significantly increased and acetyl-CoA carboxylase (ACC) and fatty acid synthase (FAS) were both significantly reduced, suggesting that the LA-supplemented aged animals are in a catabolic state. We conclude that LA remediates some of the dyslipidemic processes associated with advanced age, and this mechanism may be at least partially through entrainment of circadian clocks.
Formation of a repressive complex in the mammalian circadian clock is mediated by the secondary pocket of CRY1
The basic helix-loop-helix PAS domain (bHLH-PAS) transcription factor CLOCK:BMAL1 (brain and muscle Arnt-like protein 1) sits at the core of the mammalian circadian transcription/translation feedback loop. Precise control of CLOCK:BMAL1 activity by coactivators and repressors establishes the ~24-h periodicity of gene expression. Formation of a repressive complex, defined by the core clock proteins cryptochrome 1 (CRY1):CLOCK:BMAL1, plays an important role controlling the switch from repression to activation each day. Here in this paper, we show that CRY1 binds directly to the PAS domain core of CLOCK: BMAL1, driven primarily by interaction with the CLOCK PAS-B domain. Integrative modeling and solution X-ray scattering studies unambiguously position a key loop of the CLOCK PAS-B domain in the secondary pocket of CRY1, analogous to the antenna chromophore-binding pocket of photolyase. CRY1 docks onto the transcription factor alongside the PAS domains, extending above the DNA-binding bHLH domain. Single point mutations at the interface on either CRY1 or CLOCK disrupt formation of the ternary complex, highlighting the importance of this interface for direct regulation of CLOCK:BMAL1 activity by CRY1.
The Tidal Clock Effects of the Lunisolar Gravitational Field and the Earth’s Tidal Deformation
State-of-the-art atomic and optical clocks have the great potential to precisely test fundamental physical assumptions and enhance our understanding of nature. Their widespread applications require us to rigorously deduce the relativistic frequency shift in the framework of general relativity. One interesting question for clocks is tidal field effect which contains variously periodic variations. By introducing tidally deformed Earth, the general algorithms for clock and frequency comparisons are derived. We investigate the effects of external gravitational bodies and Earth’s tidal deformation on the ground- and space-based clocks. The orbital elements of satellite and locations of laboratory are introduced for corresponding clocks, in which the secular and long-period terms and short-period terms are subsequently presented. These effects called tidal clock effects produce the non-negligible contributions in the modern clock experiments and can be directly evaluated from our parameterized formulas. In addition, we also demonstrate for tidal clock effects the position and distance dependences, as well as periodicity. These tidal effects and dependences can provide valuable information for the clock comparison experiments.
A Simulation Study of Quantum Clock Synchronization Using Teleportation
An important requirement in implementing distributed computing and sensing application is the synchronization of clocks at various locations. The Internet relies on the Network Time Protocol (NTP), which synchronizes clocks with accuracy in the order of milliseconds. More recently an ensemble of atomic clocks is used for navigation based on GPS. These clocks are highly accurate and provide time with very low uncertainty. Even so, many physics experiments such as distributed LIGO-based systems may require more accurate clock synchronization that is achievable using quantum entanglement. This requires the deployment of a network of quantum clocks synchronized by exploiting entangled atomic clock qubits. In this paper, we carry out a simulation study of synchronizing a network of quantum clocks interconnected by a fiber plant that supports the ESnet; the latter is used to support the classical communication needed for teleportation. We consider an existing protocol for synchro-nizing the atomic clock qubits that relies on the GHZ states. To assess the performance of the protocol we developed a discrete-event simulation of the network using IBM Qiskit framework for underlying quantum gate operations and measurements. The simulation results shed light on the resources required in terms of the number entangled qubits and the time needed to achieve the synchronization of different number of nodes in ESnet.
Colloquium: Physics of optical lattice clocks
Recently invented and demonstrated optical lattice clocks hold great promise for improving the precision of modern time keeping. These clocks aim at the 10{sup -18} fractional accuracy, which translates into a clock that would neither lose nor gain a fraction of a second over an estimated age of the Universe. In these clocks, millions of atoms are trapped and interrogated simultaneously, dramatically improving clock stability. Here the principles of operation of these clocks are discussed and, in particular, a novel concept of magic trapping of atoms in optical lattices. Recently proposed microwave lattice clocks are also highlights and several applications that employ the optical lattice clocks as a platform for precision measurements and quantum information processing.
Inference of Gene Regulatory Network Uncovers the Linkage between Circadian Clock and Crassulacean Acid Metabolism in Kalanchoë fedtschenkoi
The circadian clock drives time-specific gene expression, enabling biological processes to be temporally controlled. Plants that conduct crassulacean acid metabolism (CAM) photosynthesis represent an interesting case of circadian regulation of gene expression as stomatal movement is temporally inverted relative to stomatal movement in C3 plants. The mechanisms behind how the circadian clock enabled physiological differences at the molecular level is not well understood. Recently, the rescheduling of gene expression was reported as a mechanism to explain how CAM evolved from C3. Therefore, we investigated whether core circadian clock genes in CAM plants were re-phased during evolution, or whether networks of phase-specific genes were simply re-wired to different core clock genes. We identified candidate core clock genes based on gene expression features and then applied the Local Edge Machine (LEM) algorithm to infer regulatory relationships between this new set of core candidates and known core clock genes in Kalanchoë fedtschenkoi. We further inferred stomata-related gene targets for known and candidate core clock genes and constructed a gene regulatory network for core clock and stomata-related genes. Our results provide new insight into the mechanism of circadian control of CAM-related genes in K. fedtschenkoi, facilitating the engineering of CAM machinery into non-CAM plants for sustainable crop production in water-limited environments.
A Novel Phase-Coherent Programmable Clock for High-Precision Arbitrary Waveform Generation Applied to Digital Ion Trap Mass Spectrometry
Digital ion trap (DIT) mass spectrometry requires the ability to precisely and accurately produce waveforms. The quality of the mass spectra produced in terms of resolution and mass accuracy depend on the resolution and precision of the applied waveforms. This publication reveals a novel method for the production of arbitrary waveforms in general and then applies the method to the production of DIT waveforms. Arbitrary waveforms can be created by varying the clock frequency input to a programmable read only memory that is then input to a digital-to-analog converter (DAC). The arbitrary waveform is composed of a defined number of points that are triggered to be written after programmed numbers of clock cycles to define the arbitrary waveform. The novelty introduced here is that the direct digital synthesis (DDS) generated clock frequency can be precisely changed as the arbitrary waveform is written because we have developed a method to rapidly switch the DDS frequency exactly at the end of the output clock cycle allowing exact timing of multiple transitions to produce precise and temporally complex waveforms. Changing the frequency only at the end of the output clock cycle is a phase coherent process that permits precise timing between each point in the arbitrary waveform. The waveform generation technique was demonstrated by creating a prototype that was used to operate a digital ion trap mass spectrometer. The jitter in the phase-coherent DDS TTL output that was used as the frequency variable clock was 20 ps. This jitter represents the realizable limit of precision for waveform generation. The rectangular waveforms used to operate the mass spectrometer were created with counters that increased the jitter to 100 ps. The mass resolution achieved was 5000 at m/z = 414. This resolution corresponds to a jitter of 275 ps assuming DC fluctuations and overshoots in the waveform are insignificant. Resolution should improve with increasing mass because the waveforms have longer periods while the jitter should remain constant. Given the current limit of the variable clock resolution, much better mass resolution should be achievable with future generations of the waveform production system. The agility of the DDS function generators permits the phase-coherent variable clock to be switched at a rate up to 250 MHz. This permits arbitrary waveforms to be produced with much more temporal complexity than previously possible.
Method and apparatus to debug an integrated circuit chip via synchronous clock stop and scan
An apparatus and method for evaluating a state of an electronic or integrated circuit (IC), each IC including one or more processor elements for controlling operations of IC sub-units, and each the IC supporting multiple frequency clock domains. The method comprises: generating a synchronized set of enable signals in correspondence with one or more IC sub-units for starting operation of one or more IC sub-units according to a determined timing configuration; counting, in response to one signal of the synchronized set of enable signals, a number of main processor IC clock cycles; and, upon attaining a desired clock cycle number, generating a stop signal for each unique frequency clock domain to synchronously stop a functional clock for each respective frequency clock domain; and, upon synchronously stopping all on-chip functional clocks on all frequency clock domains in a deterministic fashion, scanning out data values at a desired IC chip state. The apparatus and methodology enables construction of a cycle-by-cycle view of any part of the state of a running IC chip, using a combination of on-chip circuitry and software.
Global synchronization of parallel processors using clock pulse width modulation
A circuit generates a global clock signal with a pulse width modification to synchronize processors in a parallel computing system. The circuit may include a hardware module and a clock splitter. The hardware module may generate a clock signal and performs a pulse width modification on the clock signal. The pulse width modification changes a pulse width within a clock period in the clock signal. The clock splitter may distribute the pulse width modified clock signal to a plurality of processors in the parallel computing system.
Generating clock signals for a cycle accurate, cycle reproducible FPGA based hardware accelerator
A method, system and computer program product are disclosed for generating clock signals for a cycle accurate FPGA based hardware accelerator used to simulate operations of a device-under-test (DUT). In one embodiment, the DUT includes multiple device clocks generating multiple device clock signals at multiple frequencies and at a defined frequency ratio; and the FPG hardware accelerator includes multiple accelerator clocks generating multiple accelerator clock signals to operate the FPGA hardware accelerator to simulate the operations of the DUT. In one embodiment, operations of the DUT are mapped to the FPGA hardware accelerator, and the accelerator clock signals are generated at multiple frequencies and at the defined frequency ratio of the frequencies of the multiple device clocks, to maintain cycle accuracy between the DUT and the FPGA hardware accelerator. In an embodiment, the FPGA hardware accelerator may be used to control the frequencies of the multiple device clocks.
Generating clock signals for a cycle accurate, cycle reproducible FPGA based hardware accelerator
A method, system and computer program product are disclosed for generating clock signals for a cycle accurate FPGA based hardware accelerator used to simulate operations of a device-under-test (DUT). In one embodiment, the DUT includes multiple device clocks generating multiple device clock signals at multiple frequencies and at a defined frequency ratio; and the FPG hardware accelerator includes multiple accelerator clocks generating multiple accelerator clock signals to operate the FPGA hardware accelerator to simulate the operations of the DUT. In one embodiment, operations of the DUT are mapped to the FPGA hardware accelerator, and the accelerator clock signals are generated at multiple frequencies and at the defined frequency ratio of the frequencies of the multiple device clocks, to maintain cycle accuracy between the DUT and the FPGA hardware accelerator. In an embodiment, the FPGA hardware accelerator may be used to control the frequencies of the multiple device clocks.
Generating clock signals for a cycle accurate, cycle reproducible FPGA based hardware accelerator
A method, system and computer program product are disclosed for generating clock signals for a cycle accurate FPGA based hardware accelerator used to simulate operations of a device-under-test (DUT). In one embodiment, the DUT includes multiple device clocks generating multiple device clock signals at multiple frequencies and at a defined frequency ratio; and the FPG hardware accelerator includes multiple accelerator clocks generating multiple accelerator clock signals to operate the FPGA hardware accelerator to simulate the operations of the DUT. In one embodiment, operations of the DUT are mapped to the FPGA hardware accelerator, and the accelerator clock signals are generated at multiple frequencies and at the defined frequency ratio of the frequencies of the multiple device clocks, to maintain cycle accuracy between the DUT and the FPGA hardware accelerator. In an embodiment, the FPGA hardware accelerator may be used to control the frequencies of the multiple device clocks.