Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold atom sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

28 records · Page 2

NASA Tech Briefs, October 2007

Topics covered include; Wirelessly Interrogated Position or Displacement Sensors; Ka-Band Radar Terminal Descent Sensor; Metal/Metal Oxide Differential Electrode pH Sensors; Improved Sensing Coils for SQUIDs; Inductive Linear-Position Sensor/Limit-Sensor Units; Hilbert-Curve Fractal Antenna With Radiation- Pattern Diversity; Single-Camera Panoramic-Imaging Systems; Interface Electronic Circuitry for an Electronic Tongue; Inexpensive Clock for Displaying Planetary or Sidereal Time; Efficient Switching Arrangement for (N + 1)/N Redundancy; Lightweight Reflectarray Antenna for 7.115 and 32 GHz; Opto-Electronic Oscillator Using Suppressed Phase Modulation; Alternative Controller for a Fiber-Optic Switch; Strong, Lightweight, Porous Materials; Nanowicks; Lightweight Thermal Protection System for Atmospheric Entry; Rapid and Quiet Drill; Hydrogen Peroxide Concentrator; MMIC Amplifiers for 90 to 130 GHz; Robot Would Climb Steep Terrain; Measuring Dynamic Transfer Functions of Cavitating Pumps; Advanced Resistive Exercise Device; Rapid Engineering of Three-Dimensional, Multicellular Tissues With Polymeric Scaffolds; Resonant Tunneling Spin Pump; Enhancing Spin Filters by Use of Bulk Inversion Asymmetry; Optical Magnetometer Incorporating Photonic Crystals; WGM-Resonator/Tapered-Waveguide White-Light Sensor Optics; Raman-Suppressing Coupling for Optical Parametric Oscillator; CO2-Reduction Primary Cell for Use on Venus; Cold Atom Source Containing Multiple Magneto- Optical Traps; POD Model Reconstruction for Gray-Box Fault Detection; System for Estimating Horizontal Velocity During Descent; Software Framework for Peer Data-Management Services; Autogen Version 2.0; Tracking-Data-Conversion Tool; NASA Enterprise Visual Analysis; Advanced Reference Counting Pointers for Better Performance; C Namelist Facility; and Efficient Mosaicking of Spitzer Space Telescope Images.

Source record↗

The Interstellar Mapping And Acceleration Probe High Energy (IMAP-Hi) Neutral Atom Imager

The IMAP-Hi Energetic Neutral Atom (ENA) Imager on NASA’s Interstellar Mapping and Acceleration Probe (IMAP) mission (McComas et al. 2018a, 2025) is designed to measure ENAs from the global interaction between the heliosphere and the local interstellar medium (LISM). These ENAs are initially plasma ions of solar wind origin that are neutralized by charge exchange with the cold neutral atoms of LISM that freely flow through the heliosphere-LISM interaction region. IMAP-Hi consists of two identical single-pixel sensors, each covering the ENA spectral range from 0.44 keV to 15.6 keV over nine contiguous energy passbands and having an approximately conical field-of-view (FOV) of 4.1o full width at half maximum (FWHM). The Hi-45 sensor points 45o relative to the spacecraft spin axis from the antisunward direction; each spacecraft spin, it measures ENA intensity over a circular swath with half-cone angle 45o centered on the ecliptic plane. The Hi-90 sensor points 90o relative to the spin axis; each spacecraft spin, it measures ENA intensity over a great circle in the sky, sampling both the north and south ecliptic poles. As the IMAP spin vector is re-pointed daily toward the Sun, the ecliptic longitude of the swaths moves daily by ∼1o such that a full sky map is acquired by Hi-90 every six months and a complete low latitude (−45o to +45o) map is acquired by Hi-45 annually. The IMAP-Hi sensor design has direct heritage from the IBEX-Hi imager on the Interstellar Boundary Explorer (IBEX) mission, with substantial improvements in energy range, energy resolution, angular resolution, signal-to-noise ratio, and, for ecliptic latitudes within ±45o, temporal resolution and exposure time. The global ENA maps acquired by IMAP-Hi partially overlap in energy and viewing with the ENA maps acquired by the IMAP-Lo and IMAP-Ultra ENA imagers, which we combine to answer fundamental questions about the structure and dynamics of the interaction of the heliosphere and the LISM.

79 ASTRONOMY AND ASTROPHYSICS↗

A scanning quantum cryogenic atom microscope at 6 K

The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) is a quantum sensor in which a quasi-1D quantum gas images electromagnetic fields emitted from a nearby sample. We report improvements to the microscope. Cryogen usage is reduced by replacing the liquid cryostat with a closed-cycle system and modified cold finger, and cryogenic cooling is enhanced by adding a radiation shield. The minimum accessible sample temperature is reduced from 35~K to 5.7~K while maintaining low sample vibrations. A new sample mount is easier to exchange, and quantum gas preparation is streamlined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spin-squeezed vector atomic magnetometry

Atomic magnetometers based on Zeeman shift measurement have the potential for high sensitivity and long-term stability. Like other atomic sensors, including atomic clocks and atom interferometers, the atomic magnetometer could, in principle, be augmented with spin squeezing for further sensitivity enhancement. However, existing atomic magnetometers are not compatible with spin squeezing because the atoms can hardly be in a pure quantum state during operation. Moreover, a natural challenge faced by an atomic magnetometer is the arbitrary direction of the magnetic field. In this paper, we propose a cold-atom-based magnetometer with spin squeezing that can measure both the magnitude and the direction of an arbitrary magnetic field. For experimentally accessible parameters, we show that the technique described above could potentially achieve a sensitivity nearly two orders of magnitude higher than that of the best existing magnetometers.

Li, Jinyang [Northwestern U.] (ORCID:0000000194328↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's goal is to evaluate potential geochemical and environmental hazards that may confront future Martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. The instrument will acquire soil samples with a robotic arm equipped with a camera. MECA will examine surface and subsurface soil and dust in order to characterize particle size, shape, hardness, and also physical characteristics that may provide clues to mineralogy. MECA will characterize soil/water mixtures with respect to pH, redox potential, total dissolved ions, and trace toxins. MECA will determine the nature of electrostatic charging associated with excavation of soil, and the influence of ionizing radiation on material properties. It will also observe natural dust accumulation on engineering materials. To accomplish these objectives, MECA is allocated a mass of 10 kg within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases in wet Martian soil. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential. Experiments will include cyclic voltammetry and anodic stripping voltammetry. Complementary to the Viking experiments, the chemical laboratory will characterize the water-soil solution rather than emitted gases. Nonetheless, through analysis of dissolved gases it will be able to replicate many of the Viking observations related to oxidants. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in an actively focused, controlled illumination environment to image particles from millimeters to nanometers in size. Careful selection of substrates allows controlled experiments in adhesion, abrasion, hardness, aggregation, magnetic and other properties. Special tools allow primitive manipulation (brushing and scraping) of samples. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined using an array of sample receptacles and collection substrates. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. On Earth, the earliest forms of life are preserved as microfossils. The atomic-force microscope will have the required resolution to image down to the scale of terrestrial microfossils and beyond. Mounted on the end of the robot arm, MECA's electrometer actually consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultraviolet-light-induced ions and a low-voltage breakdown threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. The field meter will measure the ambient field on nearby objects while the triboelectric sensors, using identical circuitry, will measure the charge accumulated on test substances as they are dragged through the soil by the arm. The ion chamber, open to the environment, will sense both charged dust and free ions in the air. Over and above the potential threat to electronics, the electrostatic environment holds one of the keys to transport of dust and, consequently, Martian meteorology. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the interaction between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. A third array will passively collect dust from the atmosphere. In addition to objectives related to human exploration, the MECA data set will be rich in information relevant to basic geology, paleoclimate, and exobiology issues. To understand both contemporaneous and ancient processes on Mars, the mineralogy, petrology, and reactivity of Martian surface materials should be constrained. The MECA experiment will shed light on these quantities through its combination of chemistry and microscopy. MECA will be capable of measuring the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation.

Hecht, M. H.↗

Dual-Beam Atom Laser Driven by Spinor Dynamics

An atom laser now undergoing development simultaneously generates two pulsed beams of correlated Rb-87 atoms. (An atom laser is a source of atoms in beams characterized by coherent matter waves, analogous to a conventional laser, which is a source of coherent light waves.) The pumping mechanism of this atom laser is based on spinor dynamics in a Bose-Einstein condensate. By virtue of the angular-momentum conserving collisions that generate the two beams, the number of atoms in one beam is correlated with the number of atoms in the other beam. Such correlations are intimately linked to entanglement and squeezing in atomic ensembles, and atom lasers like this one could be used in exploring related aspects of Bose-Einstein condensates, and as components of future sensors relying on atom interferometry. In this atom-laser apparatus, a Bose-Einstein condensate of about 2 x 10(exp 6) Rb-87 atoms at a temperature of about 120 micro-K is first formed through all-optical means in a relatively weak singlebeam running-wave dipole trap that has been formed by focusing of a CO2-laser beam. By a technique that is established in the art, the trap is loaded from an ultrahigh-vacuum magnetooptical trap that is, itself, loaded via a cold atomic beam from an upstream two-dimensional magneto-optical trap that resides in a rubidium-vapor cell that is differentially pumped from an adjoining vacuum chamber, wherein are performed scientific observations of the beams ultimately generated by the atom laser.

Thompson, Robert↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

A chemical analysis of soil-water mixtures and the first microscopic images of martian soil will be among the results to be returned by the Mars Environmental Compatibility Assessment (MECA) payload on the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's primary goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. As a survey of soil properties, the MECA data set will also be rich in information relevant to basic geology, paleoclimate, and exobiology. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases. Cyclic voltammetry will address oxidants, and anodic stripping voltammetry will probe potentially hazardous trace metals. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in a controlled illumination environment to image dust and soil particles from millimeters to nanometers in size. Careful selection of substrates and an abrasion tool allows experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. Mounted on the end of the robot arm, MECA's electrometer consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultra-violet- light-induced ions and a low-voltage break-down threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. In addition, the electrostatic environment is key to transport of dust and, consequently, martian meteorology. MECA will also observe natural dust accumulation on engineering materials. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the inter-action between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. Dust accumulation as a function of conductivity, magnetic field strength, and other parameters will be explored. The MECA instruments described above will assess potential hazards that the Martian soil might present to human explorers and their equipment. In addition, MECA will provide information on the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation. Additional information is contained in the original extended abstract.

Hecht, M. H.↗

NASA Tech Briefs, July 2004

Topics: Optoelectronic Sensor System for Guidance in Docking; Hybrid Piezoelectric/Fiber-Optic Sensor Sheets; Multisensor Arrays for Greater Reliability and Accuracy; Integrated-Optic Oxygen Sensors; Ka-Band Autonomous Formation Flying Sensor; CMOS VLSI Active-Pixel Sensor for Tracking; Lightweight, Self-Deploying Foam Antenna Structures; Electrically Small Microstrip Quarter-Wave Monopole Antennas; A 2-to-28-MHz Phase-Locked Loop; Portable Electromyograph; Open-Source Software for Modeling of Nanoelectronic Devices; Software for Generating Strip Maps from SAR Data; Calibration Software for use with Jurassicprok; Software for Probabilistic Risk Reduction; Software Processes SAR Motion-Measurement Data; Improved Method of Purifying Carbon Nanotubes; Patterned Growth of Carbon Nanotubes or Nanofibers; Lightweight, Rack-Mountable Composite Cold Plate/Shelves; SiC-Based Miniature High-Temperature Cantilever Anemometer; Inlet Housing for a Partial-Admission Turbine; Lightweight Thermoformed Structural Components and Optics; Growing High-Quality InAs Quantum Dots for Infrared Lasers; Selected Papers on Protoplanetary Disks; Module for Oxygenating Water without Generating Bubbles; Coastal Research Imaging Spectrometer; Rapid Switching and Modulation by use of Coupled VCSELs; Laser-Induced-Fluorescence Photogrammetry and Videogrammetry; Laboratory Apparatus Generates Dual-Species Cold Atomic Beam; Laser Ablation of Materials for Propulsion of Spacecraft; Small Active Radiation Monitor; Hybrid Image-Plane/Stereo Manipulation; Partitioning a Gridded Rectangle into Smaller Rectangles; Digital Radar-Signal Processors Implemented in FPGAs; Part 1 of a Computational Study of a Drop-Laden Mixing Layer; and Some Improvements in Signal-Conditioning Circuits.

Source record↗

The Effect of Temperature on the Preservation of Volatile-Rich Lunar Samples

Introduction. The Moon’s south pole is a high-priority target for human exploration and scientific study. This interest is, in part, due to the presence of Permanently Shadowed Regions (PSRs), which could contain high concentrations of unique volatiles at cryogenic temperatures [1]. Returned samples from PSRs may include a unique combination of rocks, regolith, and volatile species, providing unprecedented insights into the history of the Solar System and the potential for resource utilization on the Moon. However, because PSR samples are cryogenic up-on collection, lunar polar sample return will eventually require cold stowage for the journey from the Moon to Earth. Without cold stowage, PSR sample return will likely result in phase changes and chemical reactions within the volatile component of the sample, which would negatively impact the resulting scientific studies of those samples. This abstract summarizes the initial results from an ongoing characterization of analog PSR samples at a range of temperatures, with the goal of defining the temperatures needed for a flight cold stowage freezer. Background. Based on remote sensing observations of the Moon [2], south polar PSRs range in temperature from ~120K for small and/or shallow PSRs to ~20K at the most extreme locations in large, deep PSRs. A range of volatiles have been hypothesized to exist at the surface or subsurface of the lunar poles [3-5 and others]. This hypothesis was verified when the LCROSS mission impacted the <50-K PSR in the crater Cabeus, detecting a range of volatiles from water to low condensation temperature species such as H2S and methane [6]. Species such as H2S and ammonia (also detected by LCROSS) are also highly reactive, and increase the likelihood of chemical reactions at elevated (non-cryogenic) temperatures. At the Johnson Space Center’s Planetary Exploration and Astromaterials Research Laboratory (JSC-PEARL), we have developed a volatile-bearing lunar simulant that incorporates several of the species detected by LCROSS [Table 1] mixed cryogenically with the USGS Lunar Highlands Type (LHT) regolith simulant. The new volatile-regolith simulant will be used to assess the degree of sample alteration at room temperature, -20°C, -80°C, and -196°C (liquid nitro-gen), over a two-week period. Room temperature samples represent those likely to be returned during initial missions without cold stowage, -20°C provides an analog to Apollo cold curated samples, -80°C is the temperature of multiple flight payload freezers (e.g., MELFI), and -196°C is analogous to lunar PSRs. Two weeks is an approximation of the time between sample collection and Earth return for initial Artemis missions. Over this period of time, sample head-space gases will be analyzed using a Universal Gas Analyzer (UGA, a type of mass spectrometer) coupled with a Baratron pressure sensor. After testing, the regolith component of the simulant will be purged of volatiles and preserved for future electron beam and/or FTIR analysis. Experimental Procedure. Volatile-regolith simulants will be produced as an initial homogenous batch; this batch will then be distributed into aliquots (gas chromatography/GC vials or cryo vials), ensuring that each sample has the same starting composition and conditions [Fig. 1]. In addition to the “full” simulant shown in Table 1, less complex simulant compositions will be used as baseline and control samples [Table 2]. Aliquots will be produced in triplicate for each simulant composition, storage temperature, and date of sampling. Headspace gases in all Day 0 samples will be analyzed by the UGA immediately. Cold storage samples for future analytical days will be placed in freezers appropriate to their target temperatures (-20°C, -80°C, -196°C). For ambient-temperature samples, regolith and regolith-water samples will be stored in a fume hood, while the full simulant will be stored in a sealed Parr vessel for safety; no other simulants (RWCM/ RWCM+) will be stored at ambient temperature for this test. Samples will be analyzed by UGA in this manner on each Analysis Day outlined in Table 2. Analytical Data. The UGA measures the partial pressures in a single sample aliquot over a set mass range of 0-105 atomic mass units (AMU) [Figure 2]; this set range was selected to slightly exceed the mass of the highest-mass expected reaction product (H2SO4). The Baratron complements the UGA by measuring the total pressure in the headspace of a sample vial. Coupled together, the quantitative abundances of gases will be monitored throughout the test. UGA analyses of the triplicate samples for each storage temperature, day, and simulant composition will be averaged, and standard deviations for each will be calculated. The compositions of starting species (shown in Table 1) will be characterized as a function of time, and the presence of any new compounds (reaction products) will be monitored as well. Total pressures will be recorded for each sample analysis, and any samples that show signs of leakage (e.g., a significant reduction in pressure or simulant volatiles) will be discarded. Anticipated Results. Testing is planned to begin in January 2022. The resulting data will allow compositional and phase changes in the volatile component of the simulants to be determined. Both the reduction in initial compounds and the addition of reaction products are expected to be observed. In addition, the relative efficacy of the different temperatures at pre-serving the initial composition of the simulants will be quantified. Finally, the regolith component of each sample will be argon-purged and stored in a controlled environment for future laboratory analysis. Compositional and morphological changes in the regolith are expected for samples above 0°C. This test will be repeated three times over the course of 2022. Understanding the effect of temperature on both the volatile and regolith components of analog lunar materials will allow requirements for a cold stowage freezer to be developed. The implementation of cold stowage for lunar polar missions will maximize the preservation of returned samples, enabling ground-breaking lunar and Solar System volatiles science for decades to come.

J L Mitchell↗

Spin Squeezing with Itinerant Magnetic Dipoles

Entanglement can improve the measurement precision of quantum sensors beyond the shot noise limit. Neutral atoms, the basis of some of the most precise and accurate optical clocks and interferometers, do not naturally exhibit the all-to-all interactions traditionally used to generate such entangled states. On the other hand, these systems exhibit exceedingly high degrees of experimental control over parameters such as temperature, spatial entropy, and itinerancy. In this work, we investigate spin squeezing in a highly coherent itinerant system of neutral atoms with magnetic dipole-dipole interactions. We achieve 7.1 dB of metrologically useful squeezing using finite-range spin-exchange interactions in an erbium quantum gas microscope, and we demonstrate that introducing atomic motion, realizing a dipolar 𝑡−𝐽 model, protects the spin sector coherence at low fillings, significantly improving the achievable spin squeezing in a 2D dipolar system. This work’s protocol can be implemented with most neutral atoms, opening the door to quantum-enhanced metrology in other itinerant dipolar systems, such as molecules or optical lattice clocks, and serves as a novel method for studying itinerant quantum magnetism with long-range interactions.

Atomic, optical & lattice clocks↗