Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold temperatures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Dynamic Control of Sodium Cold Trap Purification Temperature Using LSTM System Identification

This study investigates the dynamic regulation of the sodium cold trap purification temperature at Argonne National Laboratory’s liquid sodium test facility, employing long short-term memory (LSTM) system identification techniques. The investigation introduces an innovative hybrid approach by integrating model predictive control (MPC) based on first principles dynamic models with a multi-step time–frequency LSTM model in predicting the temperature profiles of a sodium cold trap purification system. The long short-term memory–model predictive controller (LSTM-MPC) model employs a sliding window scheme to gather training samples for multi-step prediction, leveraging historical data to construct predictive models that capture the non-linearities of the complex system dynamics without explicitly modeling the underlying physical processes. The performance of the LSTM-MPC and MPC were evaluated through simulation experiments, where both models were assessed on their capacity to maintain the cold trap temperature within predefined set-points while minimizing deviations and overshoots. Results obtained show how the data-driven LSTM-MPC model demonstrates stability and adaptability. In contrast, the traditional MPC model exhibits irregularities, particularly evident as overshoots around set-point limits, which can potentially compromise its effectiveness over long prediction time intervals. The findings obtained offer valuable insights into integrating data-driven techniques for enhancing real-time monitoring systems.

LSTM-MPC↗

A method for modeling battery-temperature-aware EV power profiles utilizing Next-Gen Profile data

With the expected increase in the number of electric vehicles (EVs) on the road in the coming years, it is important that analysis tools are capable of modeling and predicting the expected load on the power grid due to both individual EV charging sessions as well as large populations of vehicles. To do this accurately, the power profile of an EV charge session must be accurately modeled, including for scenarios where the temperature is above or below the ideal, and also take into account the nuances of manufacturer charging preferences. This paper introduces a method that utilizes the data in the Next-Gen Profile (NGP) data collection project to build a model of EV charging that takes into account the variations in charging power that occur due to off-nominal battery temperature and manufacturer preferences that limit power due to cold temperatures or high battery state-of-charge.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Emergence of the temperature–density relation in the low-density intergalactic medium

We examine the evolution of the phase diagram of the low-density intergalactic medium during the Epoch of Reionization in simulation boxes with varying reionization histories from the Cosmic Reionization on Computers project. The probability density function (PDF) of gas temperature at fixed density exhibits two clear modes: a warm and a cold temperature mode, corresponding to the gas inside and outside of ionized bubbles. We find that the transition between the two modes is ‘universal’ in the sense that its timing is accurately parametrized by the value of the volume-weighted neutral fraction for any reionization history. This ‘universality’ is more complex than just a reflection of the fact that ionized gas is warm and neutral gas is cold: it holds for the transition at a fixed value of gas density, and gas at different densities transitions from the cold to the warm mode at different values of the neutral fraction, reflecting a non-trivial relationship between the ionization history and the evolving gas density PDF. Furthermore, the ‘emergence’ of the tight temperature–density relation in the warm mode is also approximately ‘universally’ controlled by the volume-weighted neutral fraction for any reionization history. In particular, the ‘emergence’ of the temperature–density relation (as quantified by the rapid decrease in its width) occurs when the neutral fraction is 10 –4 ≲ X HI ≲ 10 –3 for any reionization history. Our results indicate that the neutral fraction is a primary quantity controlling the various properties of the temperature–density relation, regardless of reionization history.

79 ASTRONOMY AND ASTROPHYSICS↗

Electric Vehicle and Charging Infrastructure Assessment in Cold-Weather Climates: A Case Study of Fairbanks, Alaska

The purpose of this report is to determine the effects that extreme cold temperatures have on electric vehicles (EVs) and electric vehicle supply equipment (EVSE). The adoption of EVs in extreme cold weather presents challenges that require careful analysis of efficiency and charging infrastructure. This report, "Electric Vehicle and Charging Infrastructure Assessment in Cold-Weather Climates: A Case Study of Fairbanks, Alaska," explores how EVs and EVSE perform in temperatures as low as -40 degrees C (-40 degrees F), focusing on real-world data from Teslas in Alaskan winter conditions. The findings indicate that EVs can successfully function in extreme cold, though efficiency is significantly affected. Vehicles stored in heated environments outperformed those stored outdoors, with efficiency dropping by up to 69% for outdoor storage. Despite these challenges, none of the vehicles experienced failures that prevented travel. Storing EVs indoors led to benefits such as faster preconditioning and improved efficiency, while charging in extreme cold, though slower, remained functional. Ultimately, the report concludes that with proper precautions and best practices, EVs are viable transportation solutions in cold climates. Investing in enclosed, heated storage is recommended to maximize efficiency and minimize battery strain. As advancements in battery chemistry and thermal management progress, EV adoption in extreme climates is expected to become even more feasible.

33 ADVANCED PROPULSION SYSTEMS↗

From peak to plummet: impending decline of the warm Arctic-cold continents phenomenon

Abstract This study assesses the projected trajectory of Warm Arctic-Cold Continent (WACC) events in East Asia and North America through large ensemble simulation for the upcoming decades. It analyses the evolution of the geographical boundaries of threshold cold temperatures, revealing a significant northward shift as a sign of global warming’s impact on the southward advancement of Arctic cold air. While validating the intensification of the WACC phenomenon until the 2020 s, echoing earlier studies, the findings indicate a marked decrease beginning in the 2030s. If warming is not curbed, this shift suggests a critical modification in the WACC pattern, prompting a re-evaluation of existing theories and models for extreme winter weather events. The results have major implications, spurring communities impacted by WACC to anticipate future changes and encouraging the climate forecasting community to update conceptual models for improved adaptation and mitigation approaches.

Meteorology & Atmospheric Sciences↗

Electrochemical Mitigation of Corrosion in Molten Chloride Salts During CSP Plant Operation

We are designing an electrochemical flow-cell for removal of corrosive impurities from molten chloride salt Gen3 Concentrating Solar Power (CSP) plants during plant operation. Corrosive impurities will inevitably form in molten chloride salts upon exposure to air and moisture. We previously showed that even small amounts of these impurities, especially MgOHCl, will be detrimental in Gen3 CSP plants, necessitating prohibitively expensive containment alloys and frequent replacement of corroded components. Pre-purification of salt with Mg metal at temperatures above 650 degrees C is the current method for removing corrosive impurities from chloride salts before they are introduced to CSP systems. However, this is not a suitable method for impurity removal during plant operation. First, this method will produce MgO particulates which will damage plant components. Second, Mg metal is solid at the low temperature point (500 degrees C), so the purification will not proceed at a fast rate. At the high temperature point, Mg is soluble. In this case, fast purification may proceed, but dissolved metal is likely to precipitate out in cold-temperature point components, causing damage. In contrast, our electrochemically driven method allows fast Mg-based purification to proceed at the low temperature point, without formation of harmful particulates and without the risk of Mg metal precipitation. This novel approach is inspired by electrorefining techniques that are widely employed in industrial metallurgy for removal of impurities from metals. Impurities in the incoming molten salt will be reduced to inert MgO at the cathode, which can be removed by periodically washing the cell with acid. Simultaneously, Mg dissolution at the anode will ensure salt composition is maintained, with no net removal of Mg2+. We have validated this electrochemical approach at lab scale under static conditions with batch rectors. Furthermore, we have performed analytical modeling and technoeconomic analysis to produce a preliminary engineering design for the purification flow cell.

CSP↗

Electric Vehicle Supply Equipment (EVSE) Site Assessment Report for the U.S. Army Corps of Engineers Chena Site Near Fairbanks, Alaska

This report presents an analysis of the requirements for charging station installation and electric vehicle operation at the US Army Corps of Engineers - Chena Site, located in a cold weather climate in the Fairbanks North Star Borough, AK. The report includes findings from a site visit, and a detailed electric vehicle (EV) charging site plan with cost estimates. Cost for three 50-ampere pedestal chargers located on the edge of the existing parking lot is estimated at $\$$53,100, and the cost of three 80-ampere chargers is estimated at $\$$89,400. The authors did not assess the cost of a heated garage. The USACE Chena site reaches extreme cold temperatures of -40 Degrees Celsius (-40 Degrees Fahrenheit) and below in a typical winter, often for days on end. Considerations of operating EVs as well as electrical vehicle supply equipment (EVSE) at this site can be applicable to other cold or extremely cold locations. Interviews with EV users in cold climates and a literature review indicated that EVs operate well but have significantly decreased range compared to 21 Degrees Celsius (70 Degrees Fahrenheit) operations. Some strategies such as prewarming the vehicle while it is plugged in and using heated seats and steering wheel instead of cabin heat, can improve cold weather performance. Storing the EV in a garage would mean the battery and cabin are automatically preheated, the battery would not age as rapidly as when the vehicle is stored outside, and problems with charging the vehicle are less likely. Lowest temperate-rated Electric Vehicle Supply Equipment (EVSE), as electric vehicle chargers are known as, are rated to -40 Degrees Celsius (-40 Degrees Fahrenheit), and sometimes malfunction. No EVSE is rated to the temperatures that USACE Chena site experienced for more than a week in winter 2023-4, of -50 Degrees Celsius (-45 Degrees Fahrenheit) and which are typical for the area. If reliability is a must, entities may want to consider a heated garage to minimize potential problems with charging equipment. There is a companion technical report to this titled "Electric Vehicle and Charging Infrastructure Assessment in Cold-Weather Climates: A Case Study of Fairbanks, Alaska" that examines the data on EV and EVSE cold-weather functionality in more detail. (Esparza, Truffer Moudra, and Hodge 2024).

33 ADVANCED PROPULSION SYSTEMS↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air Source Heat Pumps: Preprint

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climates. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in the northwest United States and one in a Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five seconds, to calculate the heat pump’s capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air-Source Heat Pumps

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climate conditions. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in northwest United States and one in Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five-seconds, to calculate heat pump's capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides valuable insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving the overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lithium-Ion Battery Testing Capable of Simulating “Ultralow” Lunar Temperatures

The first-ever lithium-ion battery cycler capable of testing the coin and pouch cells under ultralow (≤40 °C) temperatures down to -175 °C to simulate extreme climates found in the lunar and space missions, high-altitude air vehicles, polar regions of Earth, and military expeditionary missions is enthusiastically reported. The extremely cold temperatures are achieved through a tailored extreme low-temperature system (ELTS) with liquid nitrogen flow and the ability to reach temperatures between -175 and 25 °C, using 1 kΩ and 1 MΩ resistors at varying currents of 1–4 mA and 1–4 μA, respectively, is validated. Employing the ELTS, Li 4 Ti 5 O 12 (LTO)||Li cells with 1 m lithium bis(fluorosulfonyl)imide in cyclopentyl methyl ether as an electrolyte developed in this research group are charged and discharged at room temperature (cycling rate C/5), -20 (C/10), -40 (C/40), and -60 °C (C/50), which exhibited discharge capacities of 159.04, 119.12, 101.79, and 33.06 mAh g -1 , respectively. Moreover, the LTO||Li cell produced a reversible capacity of 7.12 mAh g -1 tested at -100 °C for the first time.

25 ENERGY STORAGE↗

Investigation of Microwave Transducers for Linearity Dependence and Applications in Quantum Networking

Quantum devices have the potential to revolutionize applications in computing, communications, and sensing; however, current state-of-art resources must operate at extremely low temperatures, making the routing of microwave control and readout signals challenging to scale. Interest in microwave photonic solutions to this problem has grown in recent years, in which control signals are delivered to the cold stage via optical fiber, where they are converted to electrical signals through photodetection. Overall link performance depends strongly on the characteristics of the photodiode, yet detailed measurements of many detector properties remain lacking at cold temperatures. In this work, we examine and compare the performance of a modified uni-traveling carrier photodiode (MUTC-PD) at both room (300 K) and liquid nitrogen (80 K) temperatures, focusing in particular on responsivity, bandwidth, and linearity. In line with previous work, we find a sharp reduction in responsivity at 1550 nm as temperature decreases, while RF bandwidth remains steady. Interestingly, our linearity tests reveal that the RF output saturates more quickly at 80 K, suggesting reduced linearity with lower temperature, the cause of which is still under investigation. Our results should help contribute to the understanding and future design of highly linear cryogenic quantum links.

Bolton, Summer↗

Physics or Knob‐Tuning? Tropical Anvil Peak Is Captured by GCMs

Tropical anvil clouds peak near 200 hPa and significantly impact Earth's climate, yet its physical realism in coarse‐resolution General Circulation Models (GCMs) remains debated. We examine anvil cloud formation by performing simulations with a GCM with a hierarchy of cloud fraction schemes ranging from a complex prognostic Tiedtke scheme to a simple binary scheme. All schemes consistently reproduce the anvil peak. The robust anvil peak arises because extremely cold temperatures at the upper troposphere facilitate frequent saturation events, producing clouds that disproportionately influence mean cloud fraction. Sensitivity experiments with enhanced evaporation of cloud condensate unexpectedly show increased anvil coverage, highlighting how slight evaporative moistening reinforces local saturation in cold upper‐tropospheric conditions. These results demonstrate that the tropical anvil cloud peak emerges from fundamental thermodynamic constraints, rather than specific cloud fraction parameterization choices.

54 ENVIRONMENTAL SCIENCES↗

Magnetic Field Measurements of First Pre-series Full -Length 4.2 m Quadrupole MQXFA03 Using PCB Rotating Coils for the Hi Hi-Lumi LHC Project

The U.S. Hi-Lumi LHC Accelerator Upgrade Project (AUP) and CERN have joined efforts to develop high field quad-rupoles for the Hi-Lumi LHC upgrade. The US national laborato-ries in the AUP project will deliver 10 magnets and each cryostat has two 4.2 m high gradient quadrupoles in it. These magnets are made of Nb3Sn conductors, with large aperture (150 mm) and in-tegrated gradient of 556.9 T. This paper reports on magnetic measurements performed during the vertical test at Brookhaven National Laboratory (BNL) in 2019-2020. A warm measurement Z-Scan (+/- 15 A) with 42 Z-positions before cool-down was per-formed at BNL. The results were directly compared to field data measured at LBNL during magnet assembly. Measured harmonics and magnetic center offsets (ΔX and ΔY) have provided timely and informative diagnostics on the magnet structure’s shape at both warm and cold temperatures. A new centering fixture was de-signed and added to better center the warm bore tube which con-tains the rotating coil probe. After the quench training to 16.47 kA was achieved, a complete set of cold measurements (Z-Scan at 16.47 kA and I-Scan from 960 A to 16.47 kA and back to 960 A) was made. Periodic axial variation of allowed and nonallowed harmonics was observed which is related to the coil radial and/or mid-plane variations along the magnet axis. Overall, the average harmonics in the straight section are within the required field boundaries.

43 PARTICLE ACCELERATORS↗

Reciprocal transplants reveal asymmetric local adaptation of Himalayan Rhododendron approaching elevational range limit

Abstract As plant species expand their upper limits of distribution under current warming, some retain both traditional climate space and biotic environment while others encounter novel conditions. The latter is the case for Rhododendron campanulatum , a woody shrub that grows both above and below treeline at our study site in the Eastern Himalayas where a very conspicuous, stable treeline was defined by a nearly contiguous canopy of tall Abies spectabilis trees, many of which are over a century old. Prior work showed that treeline had remained static in this region while R. campanulatum expanded its elevational range limit. We tested local adaptation of R. campanulatum by performing reciprocal transplants between the species' current elevational range limit (4023 m above sea level [asl]) and just above treeline (3876 m asl). Contrary to expectation, the coldest temperatures of late winter and early mid‐spring were experienced by plants at the lower elevation: R. campanulatum at species' limit (upper site) were covered by snow for a longer period (40 more days) and escaped the coldest temperatures suffered by conspecifics at treeline (lower site). The harsher spring conditions at treeline likely explain why leaves were smaller at treeline (15.3 cm 2 ) than at species limit (21.3 cm 2 ). Contrary to results from equivalent studies in other regions, survival was reduced more by downslope than by upslope movement, again potentially due to extreme cold temperatures observed at treeline in spring. Upslope transplantation had no effect on mortality, but mortality of species limit saplings transplanted downslope was three times higher than that of residents at both sites. A general expectation is that locals should survive better than foreign transplants, but survival of locals and immigrants at our species limit site was identical. However, those species limit saplings that survived the transplant to treeline grew faster than both locals at treeline and the transplants at species limit. Overall, we found asymmetric adaptation: Compared with treeline saplings, those at species limit (147 m above treeline) were more tolerant of extremes in the growing season but less tolerant of extremes in winter and early mid‐spring, displaying local adaptation in a more complex manner than simply home advantage, and complicating predictions about impacts of future regional climate change.

54 ENVIRONMENTAL SCIENCES↗

Factors affecting powerhouse passage of spring migrant smolts at federally operated hydroelectric dams of the Snake and Columbia rivers

From 2008 to 2018, acoustic telemetry studies were conducted to evaluate dam passage survival of spring migrant Chinook salmon and steelhead smolts at seven of the eight federally operated dams on the lower Snake and Columbia rivers. Data from over 87 000 dam passage events were evaluated using regression modeling to identify the effect of spill operations, environmental conditions, and fish characteristics on powerhouse passage probability. In general, powerhouse passage was positively correlated with discharge, negatively correlated with forebay temperature and fish size, and higher for fish that passed the dam at night and for those that approached from the powerhouse side of the river, suggesting powerhouse passage is largely a function of smolt activity level and swimming ability. As such, spilling large volumes of water to reduce powerhouse passage is likely to be most effective during times of reduced activity and swimming ability (e.g., at night, high flows, and cold temperatures). This information can be used to develop dam- and time-specific spill operations that optimize smolt passage, power generation, and other competing demands, such as adult passage.

60 APPLIED LIFE SCIENCES↗

Walking with the Atoms in a Chemical Bond: A Perspective Using Quantum Phase Transition

Phase transitions happen at critical values of the controlling parameters, such as the critical temperature in classical phase transitions, and system critical parameters in the quantum case. However, true criticality happens only at the thermodynamic limit, when the number of particles goes to infinity with constant density. To perform the calculations for the critical parameters, a finite-size scaling approach was developed to extrapolate information from a finite system to the thermodynamic limit. With the advancement in the experimental and theoretical work in the field of ultra-cold systems, particularly trapping and controlling single atomic and molecular systems, one can ask: do finite systems exhibit quantum phase transition? To address this question, finite-size scaling for finite systems was developed to calculate the quantum critical parameters. The recent observation of a quantum phase transition in a single trapped 171 Yb + ion indicates the possibility of quantum phase transitions in finite systems. This perspective focuses on examining chemical processes at ultra-cold temperatures, as quantum phase transitions—particularly the formation and dissociation of chemical bonds—are the basic processes for understanding the whole of chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Genomic profiles of four novel cyanobacteria MAGs from Lake Vanda, Antarctica: insights into photosynthesis, cold tolerance, and the circadian clock

Cyanobacteria in polar environments face environmental challenges, including cold temperatures and extreme light seasonality with small diurnal variation, which has implications for polar circadian clocks. However, polar cyanobacteria remain underrepresented in available genomic data, and there are limited opportunities to study their genetic adaptations to these challenges. This paper presents four new Antarctic cyanobacteria metagenome-assembled genomes (MAGs) from microbial mats in Lake Vanda in the McMurdo Dry Valleys in Antarctica. The four MAGs were classified as Leptolyngbya sp. BulkMat.35, Pseudanabaenaceae cyanobacterium MP8IB2.15, Microcoleus sp. MP8IB2.171, and Leptolyngbyaceae cyanobacterium MP9P1.79. The MAGs contain 2.76 Mbp – 6.07 Mbp, and the bin completion ranges from 74.2–92.57%. Furthermore, the four cyanobacteria MAGs have average nucleotide identities (ANIs) under 90% with each other and under 77% with six existing polar cyanobacteria MAGs and genomes. This suggests that they are novel cyanobacteria and demonstrates that polar cyanobacteria genomes are underrepresented in reference databases and there is continued need for genome sequencing of polar cyanobacteria. Analyses of the four novel and six existing polar cyanobacteria MAGs and genomes demonstrate they have genes coding for various cold tolerance mechanisms and most standard circadian rhythm genes with the Leptolyngbya sp. BulkMat.35 and Leptolyngbyaceae cyanobacterium MP9P1.79 contained kaiB3, a divergent homolog of kaiB.

59 BASIC BIOLOGICAL SCIENCES↗

Exposing and Reducing Biases of Simulating Mixed-Phase Clouds in the Convection-Permitting E3SM Atmosphere Model: Lessons From an Arctic Cold-Air Outbreak

Mixed-phase clouds modulate the water and energy cycles of high-latitude regions, yet their liquid-ice phase partitioning has long been poorly simulated in climate models. Here, simulations of Arctic mixed-phase clouds by the Simple Cloud-Resolving E3SM Atmosphere Model (SCREAM) are assessed against large-eddy simulations, satellite data, and ground-based observations during the Cold-Air Outbreaks in the Marine Boundary Layer Experiment field campaign. SCREAM simulates nearly completely frozen clouds, which is attributed largely to the unreasonably strong Wegener–Bergeron–Findeisen (WBF) process that converts liquid to ice excessively and partly to the early over-abundant ice production at cold temperatures from a temperature-deterministic deposition ice nucleation scheme. Assuming no subgrid variation for the WBF process in the original formulation particularly conflicts with the instantaneous saturation adjustment assumption in the condensation scheme that assumes subgrid variability, leading to exaggerated WBF process rates. A proposed simple physically-based improvement on the treatment of subgrid cloud overlap substantially increases supercooled liquid water content and notably improves cloud-top phase partitioning, aligning better with observations. Improvement of supercooled liquid water content also converges with increasing horizontal resolution. The deposition ice nucleation scheme is found responsible for a falsely-produced ice cloud aloft that is not observed, biasing the simulated cloud radiative effects and top-of-atmosphere radiative fluxes. This study identifies key deficiencies in cloud parameterizations that continue to challenge convection-permitting models.

Geosciences↗