Search NASA⌕ Search

SEARCH · Search NASA

Results for “commercial space”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Scalable, Dual-Mode Occupancy Sensing for Commercial Venues

The ability to establish accurate occupancy is a key enabler for improved energy efficiency in human-occupied indoor spaces. The accurate counts can be used to adjust, in real-time, air exchange, heating, and cooling, to closely match the environmental needs of the occupants rather than to use a single setting based on maximum room occupancy. This project focuses on the use of overhead fisheye cameras and artificial intelligence (AI) algorithms as the technology to realize accurate people counting in large commercial spaces. We developed Computational Occupancy Sensing SYstem ("COSSY''), which supports large-scale deployment (thousands of square feet) and straightforward installation (using conventional power over ethernet), while providing high accuracy and low cost. COSSY has been validated at Boston University and by a third party, demonstrating people-counting accuracy of at least 89.5% in large spaces (2,000 sqft). A cost/benefit analysis performed for Boston commercial market indicates that a full payback of COSSY deployment costs due to energy savings would occur within 3-6 months from installation. Applications of COSSY reach far beyond saving energy. The precise people counting in real time could also be useful for emergency response (e.g., fire), in spatial analytics (e.g., office space management) and in some health applications (e.g., social distance assessment during pandemics).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Systematic approach to define a prototype building model: Convenience Store

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities, continuous efforts have been made to convert 30 prototype building models, which cover 80% of commercial building floor space in the United States, into OpenStudio Standards prototype buildings. In this paper, we provide a systematic approach to define the building and system characteristics of a convenience store, which has the largest energy use intensity among the commercial building types not covered by current prototype models. This study will be used as a basis for developing the prototype convenience store building model.

Yoon, Yeobeom↗

Empirical Assessment of the Appliance-Level Load Shape and Demand Response Potential in India

Over the next 15 years, electricity demand from the key residential and commercial appliances is projected to be nearly 300 GW or ~65% of India’s total peak demand. The objective of this study is to characterize appliance level demand and temporal variation, and identify the overall DR potential in India. We use Bangalore Electricity Supply Company territory (peak load of 3,505 MW in 2016) as a case study, using actual one-minute resolution load data for 2,979 distribution feeders and a detailed load survey. Our results show that agricultural pumping and space cooling (residential, commercial, and industrial) are the main contributors to the peak demand – with shares of 23-27% and 14-23%, respectively. Both sectors have about 1,000 MW of DR potential – agricultural pumps offering load shifting service while space cooling offering shimmy service that is capable of dynamically adjusting to react to short-run ramps and grid disturbances. Residential electric water heaters contribute nearly 18% of the winter morning peak demand and can also offer about 500 MW in shimmy service. Overall, we find that shifting and shimmy services offer 1,199 MW and 1,511 MW total DR potential, respectively.

demand response↗

Genetic correlations between switchgrass performance in sward conditions and surrogate measures

Switchgrass (Panicum virgatum L.) breeders use spaced-seedling plots for evaluations of biomass yield, but prior studies are ambiguous about the relationship between performance in spaced plots and commercial seeded sward performance. This study used a split-plot incomplete block design to evaluate 52 half-sib switchgrass families across two years to determine the correlations among four different plot types (including seeded swards) and four individual plant traits. Plots (1.62 m 2 ) that contained 3, 6, and 18 plants had mean yields of 5.92, 8.04, and 11.06 Mg ha –1 , respectively, while seeded-sward plots had a mean of 5.37 Mg ha –1 . In a mixed-model analysis including family-, year-, and plot-type interactions with a spatial-spline correction, the largest proportion of family variance was accounted for by the main family effect (48%), while the plot type-by-family effect was only 17% of family variance. These results indicate that spaced-plant plots are reasonable surrogates for biomass performance in sward conditions. Yield reliability was 0.50 across all plot types with a mean of 0.46 for individual plot types. Surrogates for sward yield varied due to genetic background of the families. Yield of families derived from the Liberty cultivar (n = 32) had genetic correlations with winter survivorship scores (0.66). Diverse lowland ecotype families (n = 20) had genetic correlations with plant height and heading date. This study highlighted a major difference in performance among the plot types, specifically that seeded swards have depressed yield due to high plant density. This should encourage further research for the mechanism behind this difference in performance.

59 BASIC BIOLOGICAL SCIENCES↗

Prototype College Building Energy Model: Building Characteristics and Energy Simulation Results

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 16 prototype building models, which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype college building, and a 4-story with 69,063 ft 2 building was considered as the prototype college building to represent an average-sized college building in the United States. To represent realistic occupancy schedules and increase the granularity of information, actual class reservation schedules were collected and used. This report documents the building and system characteristics of the prototype college building model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. The site energy use intensity of the college building was compared with 2012 Commercial Building Energy Consumption Survey (CBECS) and ENERGY STAR data to verify the simulation results. The site energy use intensity of the college building ranged from 60 to 202.4 kBtu/ft 2 , and compared with the energy use intensities of Commercial Building Energy Consumption Survey (122.9 kBtu/ft 2 ) and ENERGY STAR (84.3 kBtu/ft 2 ) data, the prototype college building results are in a reasonable range.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Completion of initial reduced-order model for flammable refrigerant dispersal in residential spaces

Environmental regulations aimed at reducing global warming impacts of HVAC&R refrigerants have resulted in the phase-out of chlorofluorocarbons (CFCs) in 2010 and hydrochlorofluorocarbons (HCFCs) by 2030 in developed countries with additional restrictions on the use of hydrofluorocarbons (HFCs) set to take effect in 2036. Many of the remaining alternative refrigerants that have lower global warming potential (GWP) and that are suitable for use in HVAC&R systems (e.g., propane, difluoromethane) are flammable to some degree. Flammable refrigerants introduce new challenges and hazards to property and personal safety related to potential deflagration during system maintenance or due to leakage of the refrigerant accumulating in the conditioned space. Standards have been developed to set maximum charge limits for flammable refrigerants in HVAC&R systems; however, existing safety standards and codes still restrict their use. The bodies that maintain and update these codes need publicly available, science-based information to enable credible guidelines for setting safe charge limits for different flammable refrigerants in different HVAC&R applications. In 2016, the Alliance for Responsible Atmospheric Policy, the Air-Conditioning Heating and Refrigeration Institute (AHRI), ASHRAE, the U.S. Department of Energy (DOE), and the State of California began efforts to develop such information. As part of this effort, Oak Ridge National Laboratory (ORNL) began the current, ongoing project to examine imposed charge limits for flammable refrigerants and identify reasonable adjustments to these limits when found appropriate. Past tasks under this project have included development of experimentally vetted, computational fluid dynamics (CFD) simulation approaches to study the results of leakage of flammable refrigerants from various HVAC&R systems into different types of commercial and residential spaces. In this report, we discuss recent efforts to develop a predictive model of the flammable volume fraction and accumulated refrigerant mass in a single-room residential space resulting from the leak of a flammable refrigerant from a small room air conditioning (RAC) unit. The eventual goal is development of a model suitable for public release which could simulate a range of scenarios. In discussions with the AHRTI Flammable Refrigerant Subcommittee (FRS) at the beginning of this effort, a total of 9 input parameters were chosen for consideration including room area, room/door opening area, ventilation fan flow rate, unit/leak height, leak area, leak rate, total refrigerant charge, refrigerant molecular weight, and state of the unit fan.

42 ENGINEERING↗

Defining the Prototype Convenience Store Building Characteristics

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 30 prototype building models (20 different building types), which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). This report documents the building and system characteristics of the prototype convenience store building model. Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype convenience store building characteristics, and a one-story, 3,000 ft 2 building was considered as the prototype convenience store to represent an average-sized convenience store in the United States. The Oak Ridge National Laboratory team defined the operational hours of the convenience store as 17 hours per day. The types of exterior walls, roof, and floor were defined as brick wall, metal surfacing roof, and slab-on-grade floor, respectively. Double glazing was selected, and the window-towall ratio was set as 15% on the front side. For the system part, packaged system and centralized water heater were selected for the space heating and cooling system and water heater system, respectively. In terms of the refrigerator system, the number of refrigerators and freezers were determined as eight closed cases and two walk-in units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Definition and Execution of Regulatory requirements for acceptance of the Whooshh Fish Transport System (Abstract)

The purpose of this project is to assist in the definition, summarization, and execution of the regulatory requirements that validate the Whooshh Fish Transport System (WFTS) as an accepted method of fish passage transport for Endangered Species Act- (ESA) listed species; moving these fish past in-stream barriers, such as hydropower facilities. Validation of this technology, through testing by PNNL, means that regulatory agencies will have documented evidence from which to support an approval decision enabling Whooshh to quickly commercialize their product for use in waterways with ESA listed species and provide the hydropower relicense/development marketplace a viable solution to the fish passage problem that threatens the hydropower industry. Given the definition of “take” in the ESA, without validation, commercialization in this space in the U.S. will not happen because the regulatory agencies will not have the determinative study results they require to authorize the use of this new technology that interact with ESA-listed species.

13 HYDRO ENERGY↗

SAF Grand Challenge: October 2021 – September 2024 Progress Report Fact Sheet

An interagency team led by the U.S. Department of Energy (DOE), U.S. Department of Agriculture (USDA), U.S. Department of Transportation (DOT), and other federal agencies including the U.S. Department of Defense, U.S. Environmental Protection Agency, National Aeronautics and Space Administration, and Commercial Aviation Alternative Fuels Initiative have made important progress on accelerating acceptance and growth of sustainable aviation fuel (SAF) as a primary strategy in aviation decarbonization. The progress made by these federal agencies supports the interagency SAF Grand Challenge, including new funding opportunities and initiatives aligned with the SAF Grand Challenge Roadmap; providing expertise and technical assistance to industry; increasing interagency collaboration; and providing data, modeling, and analysis to decision makers.

Sustainable Aviation Fuel Aviation SAF↗

Event-Based Energy Impact Tracking and Forecasting with Limited Measurements for Rooftop Units

Packaged air conditioning units and heat pumps, also known as rooftop units (RTUs), are responsible for almost 133 billion kWh of electricity usage annually on site for space cooling U.S. commercial buildings. In addition, the use of heat pumps is a trend we expect to accelerate as buildings transition from fossil fuel-based heating to electricity as a key step for decarbonizing the U.S. commercial buildings sector. However, the operation conditions and energy use of RTUs and heat pumps are usually not well monitored as they are not commonly integrated with building automation systems and lack exposed sensing and control points. To fill this gap, this paper proposes a framework for tracking and forecasting energy impacts resulting from degradation of performance and improved performance for unit servicing using limited data. The proposed framework makes use of a constrained dataset, specifically measurements of the outdoor air temperature and the power demand of individual RTUs, to track and forecast changes in energy use associated with changes in performance over various temporal horizons ranging from days to weeks. Following the detection of an RTU fault, performance degradation, or performance improvement, the framework employs a prediction model to assess the cumulative energy impact. We demonstrate the effectiveness of the method with field-collected data for servicing and degradation examples and compare the predicting accuracy of Gradient Boosting Decision Tree (GBDT) Regression models to Support Vector Regression and Linear Regression models. The results show that GBDT achieved the best accuracy for time-series validation datasets for the servicing and degradation cases, and the prediction model was able to track the cumulative energy impacts of events. The proposed framework can inform building owners of the cumulative change in energy usage of RTUs associated with performance degradation, performance improvement, or a fault.

packaged air conditioners, packaged heat pumps, ro↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Temporal Dynamics of Place and Mobility

Despite variations in the population, climate, economics, politics, and culture, every country and city around the world shares the same time constraints: there are only 24 hours per day. Yet, the time-dependent activity patterns of when people interact with or move between public, private, and commercial locations change across space and across spatial scales. The temporal dynamics of a place reveal unique patterns based on the complex social, economic, and cultural interactions of humans across the built environment. The continued expansion of multi-modal temporal and geospatial data has attracted many disciplines to study temporal dynamics, each with its own interests, data, methods, and use cases. A comprehensive understanding of how the temporal patterns of a place are created, disrupted, and evolve is reliant on disciplines collaborating and sharing their unique perspectives. This chapter highlights ongoing work in this field and proposes core research questions that should be pursued with the appropriate collaboration and synthesis of data.

Sparks, Kevin↗

Detecting Passing Valves at Scale Across Different Buildings and Systems: A Brick Enabled and Mortar Tested Application

Heating hot water distribution systems are typically used in commercial buildings to condition spaces to provide occupant thermal comfort. However, recent research shows significant distribution losses within these systems that drive down the overall hot water plant efficiency. This research focuses on detecting passing valves in reheat coils found in variable air volume (VAV) terminal units to reduce distribution losses. A passing valve allows hot water flow when the actuator on the valve is commanded to be closed. The fluid causes unintentional heating or cooling to occur, causing comfort and control issues, and wasting energy. We developed the passing valve detection algorithm using a framework based on the Brick schema and Mortar platform to ensure that the application is portable and can scale to many buildings. We applied the same application to analyze 1,335 VAV reheat terminal units in 20 buildings. The diversity found in these large datasets increases confidence that any building with VAV reheat terminal units with the required sensors and Brick data model can run our open-source algorithm with little or no modification. In aggregate, 5% of VAV units analyzed were categorized as having a sensor fault, 14% with potential passing valve fault, and 81% with no faults detected. However, there is a significant variation in the proportion of VAV units with a passing valve detected (1% to 83%) of each building’s analyzed units.

Roa, Carlos Duarte↗

Empirical Validation of Multi-Zone HVAC System Model: Evaluation of Existing Infiltration Models used in Building Energy Simulation

Infiltration can have a significant impact on building loads. Studies have shown that infiltration can account for 15-40% of annual space conditioning needs in commercial buildings (Emmerich et al. 2019; Younes et al. 2012). The driving force of infiltration is the pressure difference across the building envelope caused by wind, the stack effect (known as buoyancy effect), and the operation of ventilation equipment. Wind pressure is governed by wind direction, speed, building shape, and other structures around the building. The stack effect is a function of the building height and air density differences of ambient air (Han, 2015). The effect of wind is dominant in low-rise residential buildings, and the stack effect is dominant in highrise buildings (ASHRAE 2017). In building energy simulation programs (e.g., EnergyPlus), various empirical infiltration models (e.g., the effective leakage area model, the flow coefficient model) are available to simulate infiltration rates. To help users in selecting a proper infiltration model for modeling of the two-story Flexible Research Platform (FRP), the team evaluates the existing infiltration models in EnergyPlus based on field measurements from the FRP. The blower door and tracer gas decay tests were performed in the FRP. The blower door test result was used to estimate input parameters required in the infiltration models. The actual infiltration rates were estimated with the tracer gas decay test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling In-Core Strain Measurement: Printed Sensors for Advanced Reactors

Advances in nuclear energy systems require an improved understanding of fuels, cladding, and structural materials; however, the extreme environmental conditions at irradiation test facilities often limit mechanical property evaluation to post-irradiation examination. In-situ monitoring techniques can accelerate materials qualification by providing direct insight into real-time material behavior during irradiation testing. Additively manufactured (AM) strain gauges offer a compact, material-compatible alternative to commercial sensors, particularly where space constraints, attachment limitations, or material compatibility requirements complicate conventional sensor use. This poster presents an overview of the development and testing of AM strain gauges in nuclear-relevant environments, demonstrating their potential to enhance structural health monitoring capabilities during irradiation experiments.

36 - MATERIALS SCIENCE↗

Proton-Radiation Tolerant All-Perovskite Multijunction Solar Cells

Radiation-resistant but cost-efficient, flexible, and ultralight solar sheets with high specific power (W g -1 ) are the "holy grail" of the new space revolution, powering private space exploration, low-cost missions, and future habitats on Moon and Mars. Herein, this study investigates an all-perovskite tandem photovoltaic (PV) technology that uses an ultrathin active layer (1.56 micrometers) but offers high power conversion efficiency, and discusses its potential for high-specific-power applications. This study demonstrates that all-perovskite tandems possess a high tolerance to the harsh radiation environment in space. The tests under 68 MeV proton irradiation show negligible degradation (<6%) at a dose of 10 13 p + cm -2 where even commercially available radiation-hardened space PV degrade >22%. Using high spatial resolution photoluminescence (PL) microscopy, it is revealed that defect clusters in GaAs are responsible for the degradation of current space-PV. By contrast, negligible reduction in PL of the individual perovskite subcells even after the highest dose studied is observed. Studying the intensity-dependent PL of bare low-gap and high-gap perovskite absorbers, it is shown that the V OC , fill factor, and efficiency potentials remain identically high after irradiation. Radiation damage of all-perovskite tandems thus has a fundamentally different origin to traditional space PV.

14 SOLAR ENERGY↗

Efficiency of Room Air Cleaners for Removal of Bioaerosols From Ambient Air

The COVID-19 pandemic necessitated the evaluation of commercial air purification units to protect worker safety in indoor spaces. This project evaluated the efficacy of commercial off-the-shelf air purification systems that utilize electrostatic precipitation for the collection and removal of particulates (including bioaerosols) from ambient air. An aerosol mist containing Escherichia coli (E. coli) and bacteriophage surrogate virus, MS2, was produced using a nebulizer and delivered to the front intake of the commercial system with the ionizer ON and OFF. Removal efficiency was evaluated by colony/plaque formation assays using a small agar plate (60 X 15 mm) to passively collect E. coli and MS2 exhausting from the electrostatic precipitation cell. The system was determined to remove 98-99% of the microorganism introduced to the system. Testing was performed with all pre- and post-electrostatic cell filters removed so further removal is anticipated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗