Search NASA⌕ Search

SEARCH · Search NASA

Results for “commonwealth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

High-Resolution Regional Wave Hindcast for U.S. Pacific Island Territories

This report summarizes modeling efforts for hindcasting of wave climate within the Exclusive Economic Zone around American Samoa, Baker Island and Howland Island, Commonwealth of Northern Mariana Islands, Guam, Jarvis Island, Johnston Atoll, Palmyra Atoll and Kingman Reef, and Wake Island. The report describes the mesh development and data sources used in the process. In addition, it provides the results of a sensitivity analysis performed to determine the optimal model configuration, details the data used for model forcing, shows a detailed skill assessment, and depicts the output.

16 TIDAL AND WAVE POWER↗

Energy Efficiency and Performance Evaluation of Self-Contained, Medium Temperature, Reach-In Refrigerated Display Cases

This project was part of an effort by Commonwealth Edison Company (ComEd) to evaluate the energy and peak demand saving potential of emerging technologies in the Chicago area. This document focuses on the assessment of energy-efficient, medium-temperature, self-contained refrigerated display cases utilizing environmentally friendly refrigerants. The results of this evaluation will be considered by CLEAResult to develop a new energy efficiency rebate measure for ComEd's incentive programs. This rebate measure will become an addition to the Technical Reference Manual (TRM). In 2016, the United Nations passed the Kigali Montreal Protocol Amendment which placed restrictions on certain types of refrigerants. In compliance with this amendment, the US Environmental Protection Agency (EPA) placed a ban on the manufacture of refrigeration systems using hydrofluorocarbons including R134a starting in January 2020. Although the ban has halted manufacture, the EPA continues to allow the use of these refrigerants. Therefore, it is critical to provide incentives for replacing these refrigerants with other environmentally friendly and energy-efficient alternatives. The energy-efficient refrigerator cases evaluated here (referred to as EE Case A and B) contain environmentally-friendly refrigerants in compliance with the EPA hydrofluorocarbon ban. These consist of natural refrigerant propane (R290), and HFC drop-in hydrofluoroolefin R513a, respectively. These cases also contain other energy-efficient components including efficient lighting, more robust evaporator and condenser fans and different-sized heat exchangers. EE Case A is also built with materials that better insulate the case, which improves energy efficiency. To ascertain the energy efficiency contribution of these design components, the consumption of the evaporator and condenser fan motors, compressor, and lighting/controller were evaluated individually. The medium-temperature, self-contained reach-in refrigerated display case was selected due to its widespread use in convenience stores and small supermarkets. Self-contained refrigeration has also seen increased use in restaurants due to curbside pickup during the COVID-19 pandemic. For this study, the refrigerated display cases' performance was evaluated in a controlled environmental chamber at representative indoor dry-bulb and humidity conditions found in supermarkets within ComEd's service territory climate zone. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 method of testing. However, modifications to the ANSI/ASHRAE test methodology were implemented to better represent customer operation of the units. In addition to the indoor supermarket conditions, the cases were also evaluated at the "upper target," or environmental conditions used in ANSI/ASHRAE 72-2018. The case total power and case components were metered to obtain their daily power (kW) and energy consumption(kWh). The cases were filled with thermal filler mass to replicate thermal mass of product loading. Additionally, product simulators were used to provide product temperature information. Door actuators were mounted to each of the cases' three doors to replicate regular door openings and effects of shopper traffic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Assessment of High Efficiency Variable Speed Air-Source Heat Pump in Cold Climate Applications

This project was part of an effort by ComEd's emerging technology program to evaluate the energy saving potential of new energy efficiency technologies. The focus of this technology assessment was to determine energy and peak demand savings potentials of a high efficiency variable speed, air-source, split system heat pump designed for cold climate applications. The results of this technology assessment will be used by CLEAResult to develop a new energy efficiency measure for Commonwealth Edison Company's incentive programs. The project utilized the National Renewable Energy Laboratory's (NREL) Thermal Test Facility to experimentally characterize cooling and heating performance of a high efficiency heat pump split system under varying outdoor climate conditions. The selected climate conditions represented summer and low temperature winter conditions in ComEd's service territory. The laboratory experimentation results were used to develop equipment performance curves required by EnergyPlus hourly simulation engine. Using typical meteorological year 3 weather data for the Chicago O'Hare airport, hourly building simulations (using the EnergyPlus engine) was utilized to estimate the annual energy savings of the high efficiency heat pump in comparison to a standard efficiency unit in the following U.S. Department of Energy (DOE) building codes program energy prototypes: Single-family residence; Strip mall; and Low-rise office.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SPARC 3D Field Physics and Support of the Non-Axisymmetric Coil Assessment

Commonwealth Fusion Systems (CFS) is deploying SPARC, a net-energy tokamak, by 2025. A notable challenge facing all tokamak approaches to fusion energy production is maintaining a stable plasma and thereby steady energy production. “Disruptions” to plasma operation are often encountered in devices when they operate at high normalized pressure, high normalized density, or high normalized current. SPARC is unique in that it is expected to demonstrate Q>=2 in a plasma with low normalized pressure and density, but with a more modest current limit buffer sufficient to avoid disruptions. Due to both the high normalized current and high magnetic field of the SPARC design, it is expected to decrease its relative resilience to instabilities driven by non-axisymmetry in the externally applied magnetic field, termed ‘error fields’. To prevent error field driven instabilities, a primary line of defense is strict engineering tolerances in magnet fabrication and installation. A secondary line of defense is a purpose-built set of magnetic coils to correct these errors, termed error field correction coils (EFCCs). The overarching goals of this INFUSE project were to evaluate the effectiveness of the EFCCs in the SPARC design and provide guidance as to how to improve this effectiveness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ComEd Climate Risk and Adaptation Outlook, Phase 1: Temperature, Heat Index, and Average Wind

This Climate Risk and Adaptation Outlook report presents the research and findings of a joint venture between Commonwealth Edison (ComEd) and Argonne National Laboratory (Argonne) to evaluate future climate risks to ComEd’s infrastructure and operations. ComEd recognizes that its position as the state of Illinois’ largest electric utility, serving roughly 70% of the state’s population, underscores the importance for communities across Illinois to consider climate risk as they plan for future conditions. Climate impacts, such as more severe heatwaves or more frequent flood events, can disrupt the generation, transmission, and distribution of electricity and create public health challenges. Taking a proactive approach to adapt to climate risks will help ensure that ComEd continues to serve its growing customer-base reliably and efficiently. This Climate Risk and Adaptation Outlook serves as an important first step to inform ComEd’s grid planning efforts, but Argonne and ComEd recognize that additional research beyond this report will be necessary to characterize future climate conditions more comprehensively throughout northern Illinois, to assess their impacts to grid assets and system operations, and to index effective adaptation options at an asset-level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of Liquid-Cooled Open Stand-Alone Refrigerated Cases

This project is part of a joint effort between Commonwealth Edison Company (ComEd) and the National Renewable Energy Laboratory (NREL) to evaluate the energy and demand savings potential of emerging efficient buildings technologies. This project quantifies the energy efficiency benefits from retrofitting an air-cooled, constant-speed compression, self-contained medium-temperature open-vertical display case with a high efficiency water-cooled condensing unit. In addition to a water-cooled heat rejection mechanism, the high-efficiency condensing unit utilizes a variable-speed compressor, electronic expansion valve and advanced controls system. The focus of this project, however, was mainly on capturing the energy savings potentials of the water-cooled condenser, variable-speed compression and electronic expansion valve, and not on the advanced controls. The results of this evaluation will be considered by ComEd and CLEAResult for future energy efficiency rebate offerings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Laboratory for Emerging Stacked Unconventional Plays in Central Appalachia

The goal of the Field Laboratory for Emerging Stacked Unconventional Plays (ESUP) in Central Appalachia project was to investigate and characterize the resource potential for multi-play production of emerging unconventional reservoirs in Central Appalachia. Project activities included drilling, logging and coring of a vertical characterization well drilled to basement to approximately 15,000 feet in depth. The data from drilling and well logs as well recovered core samples were used by the research team to support characterization of the geology and potential pay zones within the Nora Gas Field of southwestern Virginia and the greater Central Appalachian Basin. This project was led by Dr. Nino Ripepi of the Virginia Center for Coal and Energy Research (VCCER) in close collaboration with EnerVest Operating LLC (EnerVest). VCCER is housed in the Department of Mining and Minerals Engineering at Virginia Tech and was created by an Act of the Virginia General Assembly on March 30, 1977, as an interdisciplinary study, research, information, and resource facility for the Commonwealth of Virginia. EnerVest is a top tier, low-cost oil and natural gas company with a long history of traditional operating relationships with institutional investors as well as public and private companies. This report summarizes two major research activities: 1) Log and Core Analysis and 2) Numerical Modeling. Core analysis comprises the characterization efforts of the ESUP Field Laboratory and includes a discussion of the well logs run in the deep characterization wells, an initial analysis of those, the number, size and location of cores recovered, core testing and analysis done to date as well as plans for future analysis. Numerical modeling is comprised of seven major modeling efforts, including (1) Multiphysics shale transport modeling work, (2) the developed in-house compositional simulator studies, (3) reservoir modeling studies using GEM software, (4) fracture modeling work using EFRAC3D software and (5) numerical modeling efforts with ABAQUS software, (6) Numerical modeling efforts using FLAC3D and PFC3D, and (7) Automatic Machine Learning (AutoML) Studies.

02 PETROLEUM↗

Territorial Economic Impact Index: Measuring the ongoing effects of long-term disruptions to Pacific Island Territories

The Territorial Economic Impact Index (TEII) estimates the change in overall territory-level economic activity during the COVID-19 pandemic relative to January 2020. It shows which Pacific Island Territories may be more susceptible to large reductions in economic activity compared to normal conditions by looking at which industries make up each territory’s economy and then tracking monthly changes in industry employment at the U.S. national level. Economic activity in the TEII is measured by the total value added of all industries within the territory. Territories with economic activities dominated by industries experiencing rising unemployment can expect larger direct impacts to their local economies, particularly if the industries account for a large portion of the economic output of that county. Results are available for all three Pacific Island Territories: American Samoa, Guam, and the Commonwealth of the Northern Mariana Islands.

99 GENERAL AND MISCELLANEOUS↗

Divertor Component Testing

Power exhaust is an immense challenge in tokamaks. Commonwealth Fusion Systems (CFS), in collaboration with MIT and others, is working on the design of a compact (R 0 = 1.85 m), high-field (B 0 = 12 T) tokamak for the demonstration of net fusion energy, called SPARC. Empirical scaling laws indicate that the unmitigated heat flux in the boundary plasma will exceed 10 GW/m 2 . Such high heat fluxes will be a formidable challenge. The scope of this work is to utilize the HHF testing expertise maintained by ORNL, used in support of NSTX-U and to demonstrate the thermal performance of tungsten-coated graphitic foam targets, to help CFS and its collaborators to assess the performance of (1) base materials (tungsten and its alloys) and (2) divertor mockups under SPARC-like divertor heat flux conditions. These activities will be performed by ORNL personnel using electron beam exposure facilities at the Pennsylvania State University’s Applied Research Laboratory (ARL). ARL is a Department of Defense University Affiliated Research Center where ORNL has successfully executed NSTX-U and graphitic foam high heat flux testing using electron beam (e-beam) facilities, which is a nonstandard service. For the assessment of base materials, CFS will do an initial thermal analysis, in consultation with ORNL, to understand under what scenarios the materials are most likely to fail. CFS will supply to ORNL various tungsten-based material samples to test with testing taking 3 weeks. ORNL will thermally stress the samples under SPARC divertor-like conditions to either failure or to a prescribed number of pulses. ORNL will record experimental data, including IR surface temperature and embedded thermocouple readings, and report results to CFS

36 MATERIALS SCIENCE↗

Time-Dependent Boundary Modeling to Inform Design of SPARC Diagnostic and Actuators

The purpose of this work was to inform the design of diagnostic and actuator systems for a new experimental facility for Commonwealth Fusion Systems (CFS), called SPARC [Creely2020], using time-dependent plasma boundary simulations with the Scrape Off Layer Plasma Simulator (SOLPS) code [Wiesen2015]. The SPARC tokamak is a device that aims to demonstrate fusion energy production and high-field plasma operating scenarios. The developed technologies will be incorporated into a net-electricity pilot that will demonstrate approximately 200MW of electric power. A major difference from other private industry fusion companies is the use of a standard aspect ratio, but at a high magnetic field strength, which provides a well-established physics basis and a modest extrapolation to reactor operation. Time-dependent simulations were used to inform the design of main-chamber plasma facing components, which are protected by feedback control of the heat and particle loads during high power operation. The simulations provide the timescales and magnitudes of plasma and neutral particle response useful for determining the position and operation of diagnostics and actuators that will enable control. The plasma response and phase-space diagrams also provide input into advanced model-based control schemes, which are envisioned for later SPARC operation. Model-based control can reduce the risk of component failure, which would require expensive in-situ repairs and the associated delays, by predicting the system response to actuators over a short time-horizon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Louisville Communities LEAP Engagement: Improving Energy Efficiency in Affordable Housing [Slides]

This presentation outlines the initial results from a year-plus engagement between the National Renewable Energy Lab and Louisville, Kentucky through the U.S. Department of Energy's Communities LEAP (Local Energy Action Program) effort. Louisville, as represented by the Louisville Metro Government, Kentuckians for the Commonwealth, and the Metropolitan Housing Coalition, sought technical assistance from the labs to address energy usage in its residential housing stock as part of efforts to reduce community-wide emissions and high energy burdens throughout its community. The Communities LEAP scope of work included an energy efficiency analysis that leveraged ResStock data to identify key efficient technologies to explore for retrofitting Louisville's housing stock; technical support around developing a community benchmarking ordinance to help Louisville track its progress towards reducing energy usage; a workforce development overview to help Louisville ensure a sufficient and equitable distribution of clean-energy-related jobs supported by its energy efficiency efforts; a policy analysis component to track energy efficiency related policies Louisville may be interested in adapting from peer communities across the country; and a financing analysis component to identify opportunities to lower the barrier to clean energy adoption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Power Supply Options for the Marpi Landfill, Saipan: Addendum to 2023 Feasibility Study

The Marpi Landfill (Marpi or the landfill), located on the northern end of the island of Saipan in the Commonwealth of the Northern Mariana Islands (CNMI), is powered by an on-site diesel generator that only operates when the landfill is open and staffed. The CNMI Office of Planning and Development (OPD) aspires to provide the Marpi Landfill with 24-hour power availability despite its remote location and to increase sustainable energy consumption within the CNMI. Pacific Northwest National Laboratory (PNNL) authored a feasibility study in 2023 that explores alternative power supply options for the landfill. This feasibility study (hereafter referred to as Phase I of this study) culminated in a report named “Power Supply Options for the Marpi Landfill, Saipan.” In Phase I, the project team investigated and prioritized seven different power supply scenarios (Table ES-1) for the landfill according to Solid Waste (SW) Taskforce priorities. The project team found that Scenario 4 (100 kW of solar photovoltaic [PV] generation, a 75 kW/300 kWh battery energy storage system [BESS], and 160 kW of diesel generation) ranked highest. Following the Phase I feasibility study, the SW Taskforce secured additional funding for PNNL to assess additional considerations regarding power supply options for Marpi. The purpose of Phase II of this study is to investigate these additional considerations, as compiled in this addendum. Some of the findings compiled here replace findings from the original report. The project team evaluated additional considerations regarding power supply options for the landfill, including modified operations to account for 24/7 power supply, electrified landfill equipment, new and replacement distribution line costs, and the social cost of carbon.

14 SOLAR ENERGY↗

Power Supply Options for the Marpi Landfill, Saipan: Feasibility Study

The Marpi Landfill, located on the northern end of the island of Saipan in the Commonwealth of the Northern Mariana Islands (CNMI), is powered by an on-site diesel generator that only operates when the landfill is open and staffed. The CNMI Office of Planning and Development (OPD) aspires to provide the Marpi Landfill with 24-hour power availability despite its remote location and to increase the use of sustainable energy within the CNMI. CNMI has a 20% target for renewable energy consumption, as documented in Sustainable Development Goal #7 in the Comprehensive Sustainable Development Plan (OPD 2021) and the renewable portfolio standard (GPO 2014). To accomplish these goals, the U.S. Department of Energy, through its Interagency Reimbursable Work Agreement with the Federal Emergency Management Agency, funded this feasibility study to assess and prioritize power supply options for the landfill. The availability of solar and wind resources varies seasonally, as does the load. A BESS can help to balance mismatches between generation and load on short (hourly or daily) timescales, but not across seasons. The microgrid scenarios evaluated for Marpi consider options for technology combinations that will both meet the load and utilize available resources, despite the challenge presented by higher loads and lower solar and wind availability during the rainy season, depicted in Figure ES-2. The seven scenarios evaluated are summarized in Table ES-1. Each scenario’s configuration was optimized to include component capacities that reduce capital and operating costs, meet the load, and minimize carbon emissions, as feasible. The costs and levelized cost of energy (LCOE) shown do not assume the use of any grant funding or incentives, although these options were also evaluated. To assist with decision-making, a prioritization matrix (Table ES-3) was created to compare the microgrid scenarios evaluated in this feasibility study according to various stakeholder priorities. The prioritization metrics were chosen based on discussions with OPD and will be finalized through stakeholder feedback. The scenarios were given a score between 1 and 7 for each prioritization metric (the lower the score, the higher the priority), and total scores were calculated using assigned weights based on the relative priority of each metric. The total scores were then ranked to produce a prioritized list of microgrid scenarios based on the metrics most important to the project stakeholders. As shown, scenario 4 (100 kW of solar PV, a 75 kW/300 kWh BESS, and 160 kW of diesel generation) ranks highest.

14 SOLAR ENERGY↗

2023-2024 Energy Baseline Report: American Samoa

This document is part of a series of 2023-2024 energy baseline reports produced for the U.S. Department of the Interior's Office of Insular Affairs. The energy baseline reports cover the U.S. territories of American Samoa, Guam, the Commonwealth of the Northern Mariana Islands, and the U.S. Virgin Islands. American Samoa's 2023-2024 report provides a high-level overview of American Samoa's energy sector, the current climate and energy policy landscape in the territory, and the climate- and energy-specific challenges facing American Samoa.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Chicago Energy Efficiency Planning and Analysis and Integrated Retrofit Strategy Validation in Single-Family Homes

In June 2020, the project team comprised of Elevate and the National Renewable Energy Laboratory (NREL), with advisory roles from the City of Chicago and Commonwealth Edison, initiated a three-year project with the U.S. Department of Energy to inform communitywide energy planning at a local scale and validate advanced retrofit packages that achieve at least 50% energy savings in existing homes. The project team has characterized Chicago’s single-family and 2-4 unit housing stock and energy use using the ResStock™ modeling tool, and with that information developed advanced whole home energy retrofit packages for single family and 2-4 unit homes that can reduce energy use by at least 50% and support climate, air quality, and other goals. This report presents an analysis of the technical potential of applying these retrofit packages at a City-wide scale, and a roadmap for rapidly scaling up retrofit programs to improve Chicago’s housing stock and target investments in the neighborhoods that need it most. The main goals of the analysis are to: 1) develop a Chicago-specific single-family and 2-4 unit building retrofit prioritization strategy; 2) identify opportunities for beneficial electrification in communities and home types that stand to benefit most; and 3) assess costs and savings potential for retrofit investments at a household and city scale, in terms of energy use, bill impacts, carbon emissions, and other outcomes.

14 SOLAR ENERGY↗

Pulsed High Temperature Superconducting Central Solenoid for Revolutionizing Tokamaks

Commonwealth Fusion Systems (CFS) has developed the technical foundation for a fast-ramping High Temperature Superconducting (HTS) Central Solenoid Model Coil (CSMC), addressing key challenges in fusion energy advancement. This breakthrough enables the design of all-HTS pulsed tokamak power plants that promise to reduce projected electricity costs by 50% and overnight construction costs by 25% compared to steady-state tokamaks, while eliminating the need for complex external current drives.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Project Title: Demonstration High Temperature Superconducting NonPlanar Stellarator Magnet with Advanced Manufactured Assemblies

This is the final report for the project “Demonstration High Temperature Superconducting Non- Planar Stellarator Magnet with Advanced Manufactured Assemblies”, funded by DOE, and performed by Type One Energy from September, 2020, to March 2024 involving the Fusion Technology Institute at the University of Wisconsin–Madison, the Plasma Science and Fusion Center (PSFC) at the Massachusetts Institute of Technology (MIT) and Commonwealth Fusion Systems (CFS) to design and fabricate the first non-planar HTS (REBCO) coil for a high-field stellarator based on the SPARC tokamak’s VIPER cable concept. Stellarators at high fields make high-temperature superconducting magnets necessary for a compact fusion device. But the asymmetric and non-planar nature of its components, especially the magnets make it difficult for scalable producibility. To address these challenges, two promising technologies have emerged: advanced manufacturing (AM) for the supporting plates for forming the magnets, and high-temperature superconducting (HTS) cables inside the plates. AM has advanced enough to produce stellarator components with the necessary geometric complexity, size, and the precision, leading to potentially significant reductions in production time, cost, and waste. The cost of HTS tape has decreased dramatically, and progress in HTS planar magnet development has reached a point where it can be proposed for application to complex 3D non-planar magnets. The main objective of this project is to develop, demonstrate and pre-commercialize a novel, non-planar HTS coil shape that remains superconducting to achieve production scalable reductions in time and cost and performance. The proposed technology is based on the novel concept of a precision sub-scale HTS nonplanar coil assembly. This project focuses on the design, fabrication, material optimization of cable design, and validation and demonstration of the high current carrying capability of superconducting magnets and their support in a complex 3D shape needed for application to stellarator magnetic plasma confinement. The specific objectives of this research program include: (1) The successful application of metal AM to build a precision sub-scale HTS nonplanar coil, (2) An HTS cable and cross-section design that can conform to the required nonplanar coil shape (bend radii as tight as 10-cm) and remains superconducting at an engineering current density of 1.35 kA/cm 2 at 77 K and 1 tesla at the conductor (5 kA in the cable). To achieve the above challenging goals, we have formed a multidisciplinary research team consisting of members from Type One Energy and UW-Madison, MIT PSFC and CFS with complementary skills and strong facilities. The team worked collaboratively on fundamental and applied research on the following three major technical areas: (1) Design, fabrication, and optimization of non-planar HTS Cable The ultimate goal of the project is to determine if commercial REBCO tapes and additive manufacturing can be used to fabricate high field (≥ 10T) non-planar coils with tight bending radii (≃ 100mm) and with a degradation of the critical current (Ic) smaller than 20% with respect to the expected performance. We started with shorter length cable to evaluate the scalability of the production process and eventually reached multiple turns for higher magnetic fields. Our findings suggest that a stellarator coil system of a relevant size, characterized by its asymmetric and non-planar components, can be fabricated using a formed cable in plate method. This system can be simulated using a large-scale modeling approach. The use of hybrid modeling 3 techniques will be pivotal in reducing the complexity of the model and in assessing expected performance in designs. (2) Modeling and simulation of the non-planar HTS Cable Multiphysics simulations are performed using the commercial software and are carried out in self-field conditions, involving 2D and 3D models and twisted around one slot of twist-pitched VIPER cable. Multiphysics simulations are mainly focused on the coil for the critical current evaluation, the magnetic field map, self-Lorentz forces and mechanical, and magnetothermal behavior and the quench dynamics. The detailed model and prediction of the superconducting performance of a stellarator-relevant demonstration cable from numerical simulations supports the results from the actual testing backing the results. A detailed description and results are provided in the later sections. (3) Design, fabrication, and optimization of support for the non-planar HTS Cable The team developed an additive manufactured (AM) coil positioning plate that formed into the required non-planar geometry (with bend radii as tight as 10-cm) and to acceptable tolerances required for a stellarator magnet: (+0.25-mm from ideal on dimensions of coil positioning plates and up to +1-mm from ideal for position of wound coil). The plate materials is also included in this selection process from fabrication and 3D printing perspective and commensurate with eventual application to a fusion reactor. From the cost effectiveness point of view, the HTS coil and plate has the potential to cost less than that made in conventional methods with less waste (<75% waste) reducing time (<50%) and cost (<50%), especially as the AM field matures. The application of advanced manufacturing in the construction of the support plates will also lead to cost reduction, as the cables can be easily replaced, thereby making the assembly modular. With such high primary cost and time savings, high current densities and magnetic field, the funded R&D work has validated the designs, proven the feasibility, and characterized the performance of the HTS coil and plate assembly, paving the way for a relevant-size stellarator coil system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ICE Calculator 2.0: Final Report for Phase 1 of the National Initiative to Update the Interruption Cost Estimate (ICE) Calculator

In 2021, Berkeley Lab and Resource Innovations, Inc. launched the “ICE 2.0 Initiative” – a national study to refresh the underlying data and enhance the functionality of the ICE Calculator. The Initiative involves Berkeley Lab contracting with sponsoring utilities to administer identical, updated and comprehensive interruption cost surveys to statistically representative samples of each utility’s customers. Berkeley Lab and Resource Innovations then pool the survey results across the utilities and use them to update the analytical engines that drive the ICE Calculator. The ICE 2.0 Initiative is being conducted in phases. Each phase involves the administration of interruption cost surveys to the customers of sponsoring utilities, followed by an update to the ICE Calculator based on analysis of the pooled survey results. This report describes the activities and findings from Phase 1 of the ICE 2.0 Initiative. Phase 1 was sponsored by eight utilities: American Electric Power, Commonwealth Edison, Dominion Energy, Duke Energy, DTE Electric, Exelon, National Grid, and Puget Sound Energy. Phase 1 involved 11 customer interruption cost survey activities representing a total of 24 electricity distribution service territories, 23 of them located in the Eastern and Midwestern regions of the U.S. and one located in the Pacific Northwest. ICE 2.0 vs. 1.0 Comparison This memorandum compares customer power interruption costs estimated using the recently updated Interruption Cost Estimate (ICE) Calculator (“ICE 2.0”) to the original ICE Calculator (“ICE 1.0”). ICE 1.0 was developed in 2009 based on 15 independent power interruption cost surveys conducted by 10 electric utilities between 1989 and 2012. ICE 2.0 was developed in 2025 through a national initiative based on a consistent set of power interruption cost surveys and 11 surveying efforts conducted across 24 electric utility service territories between 2022 and 2024.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗