Search NASA⌕ Search

SEARCH · Search NASA

Results for “communication delay”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Microreactor Automated Control System Test Bed Digital Architecture for Real-Time, Hardware-in-the-Loop Simulation

This work describes progress made towards the development of a real-time hardware-in-the-loop (HIL) test bed for non-nuclear testing of microreactor control schemes and failure modes. Non-nuclear testing is a crucial step in developing robust control algorithms for managing microreactor dynamics. The creation of an HIL simulation harnesses the realistic dynamics of physical analogue systems while additionally considering the challenges of variable communication delay. This collaborative effort between Oak Ridge National Laboratory and Idaho National Laboratory has resulted in a LabVIEW-based gRPC communication protocol which couples a TRANSFORM Modelica simulation of nuclear components to the ViBRANT physical hardware for realistic feedback and visual representation of control action in real time. A modular python client structure is developed to manage FMU-based Modelica simulation and real-time gRPC communication. HIL testing suggests that the modeled reactor with natural convection molten salt loop coolant configuration responds well to PID control of drum positioning for modulation of reactor core power, however, future efforts will be made to explore the added thermal inertial delay of system level control and downstream demand changes. Development of this platform with a generalized methodology provides a foundation for exploring a variety of reactor configurations and failure modes in rapid order to provide insight into the most effective avenues of study for further research and development.

McConnell, Jono [ORNL] (ORCID:0000000238984741)↗

Isochronous Architecture-Based Voltage-Active Power Droop for Multi-Inverter Systems

This article proposes an isochronous architecture for parallel inverters with only voltage-active power droop (VP-D) control for improving active power sharing as well as plug-and-play of multi-inverter-based distributed energy resources (DERs). The isochronous framework obviates the need for an explicit regulation of the frequency while allowing for sharing of reactive power. The article shows that the detrimental effects of circulating currents between inverters can be addressed in the framework developed. The isochronous architecture is implemented by employing a GPS to disseminate clock timing signals that enable the microgrid to maintain the nominal system frequency. Small signal eigenvalue analysis of a Multi-inverter Microgrid system near the steady-state operating point is presented to evaluate the system stability. Moreover, unlike traditional droop-based methods, the isochronous strategy lends itself to analytical guarantees which are developed in the article. Furthermore, the effect of delays in receiving GPS clock signals by an inverter is experimentally characterized and an inverter isolation mechanism is proposed that disconnects inverters facing large GPS communication delays. Hardware experiments on an 1.2 kVA-prototype and controller-hardware-in-the-loop validation on the CIGRE distribution network are conducted to demonstrate the effectiveness of the proposed architecture towards active and reactive power sharing between inverters with load scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predictive Modeling and Operational Monitoring of Starlink Leo Satellite Network Performance in Maritime Environments

This thesis investigates short-term performance prediction for maritime LEO operational planning and application performance cannot anticipate available bandwidth or communication delay, which complicates variation alter signal conditions over short time scales. As a result, maritime users often fluctuations in link quality. In addition, Frequent satellite handoffs and Doppler-induced rapid satellite movement and changing atmospheric conditions cause substantial unavailable. Despite their availability, reliable operation at sea remains difficult because broadband connectivity in maritime regions where terrestrial infrastructure in

97 MATHEMATICS AND COMPUTING↗

Balance of Plant Modeling and Real-Time Hardware-in-the-Loop Integration with the Microreactor Automated Control System

The advent of novel microreactor technology has driven a focused effort to explore safety and efficiency improvements that can be achieved through the use of automated system control. Development of control strategies, especially for initial demonstration, requires an adequate surrogate environment to safely research failure modes and control integration with realistic hardware delay. However, efficiency gains from control strategies are improved when the scope of controller action is expanded to include system-level dynamics such as downstream heat extraction and mass flow. For this reason, a balance-of-plant (BOP) model of a representative microreactor system has been developed using the TRANsient Simulation Framework of Reconfigurable Models library in Modelica. This model captures a reactor and primary NaK coolant loop that represent corresponding system components of the Microreactor Applications Research Validation and EvaLuation (MARVEL) design as well as a secondary coolant loop and heat extraction representative of the Microreactor Agile Non-Nuclear Experimental Test Bed (MAGNET). This model configuration allows for hardware-in-the-loop (HIL) integration with microreactor automated control system (MACS) hardware in real time through a Python-based gRPC client. Real-time simulation of model performance with emulated hardware and communication delay suggests that under independent proportional-integral-derivative control of BOP model drum dynamics and downstream heat extraction, stable power load following is achievable. A slight delay in load following, filtering of high-frequency dynamics, and localized temperature fluctation suggest room for improvement through the development of higher-level control strategies. The simulated coupling of the MAGNET facility lays the groundwork for future digital twin analysis with a coupled MACS-MAGNET HIL demonstration.

McConnell, Jono [ORNL] (ORCID:0000000238984741)↗

Deploying advanced supervisory control strategies to small- and medium-sized commercial buildings: Case study and lessons learned

Deploying advanced supervisory control strategies (ASCSs) in small- and medium-sized commercial buildings (SMBs) is vital but faces two issues: (1) a lack of building control and communication infrastructure (BCCI) in SMBs and (2) the significant engineering efforts required to implement and configurate ASCSs. Despite hindering the large-scale adoption of ASCSs in SMBs, these issues have not been adequately explored in the literature, which tends to focus more on feasibility than scalability. This paper provides a comprehensive evaluation of these two issues through a case study of an occupied SMB in eastern Tennessee of the United States. Specifically, we design and implement a BCCI for the studied building with commercial off-the-shelf products to accommodate the needs for deploying ASCSs. Here, we then deploy two ASCSs—a rule-based setback control and a model predictive control (MPC)—with the BCCI and evaluate their performance throughout the summer of 2024. This study reveals that the main bottlenecks in establishing BCCIs for SMBs are the high initial cost (∼$56/m 2 ) and communication delays (up to 9 min). Additionally, the assessment of the two ASCSs indicates that the majority (∼75 %) of the engineering effort required for implementation and configuration is spent on model identification, debugging, and tuning.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Space Nuclear Power Autonomous Control Algorithm and Control Element Test Bed

Nuclear thermal rockets are currently NASA’s preferred option for use in a manned mission to Mars in the 2040s. The communication delay between an Earth ground station and a spacecraft heading toward Mars can be up to 20 min. Therefore, controlling the nuclear rocket engine would require either a full-time reactor operator on the mission or an autonomous control system for the reactor. The latter idea of making space nuclear reactors fully autonomous has drawn more interest from stakeholders, but such an autonomous control system must be rigorously tested and validated before it is certified for human use. The cost of a full ground test for a space nuclear reactor is tremendous, so a nonnuclear mock reactor test bed was created to test and validate control elements and control algorithms for space nuclear reactors. The test bed consists of control element hardware that inputs physical measurement data into a reactor emulator to produce the reactor’s performance under steady-state, transient, and fault conditions. The control element hardware consists of six full-sized control drums equipped with servo drives and motors and is instrumented with optical encoders, resolvers, and torque sensors for drum movement characterization. In addition to the drums, a two-phase flow loop was designed and built to mimic the valves and turbomachinery associated with the propellant flow through a nuclear thermal rocket engine; components such as pressure sensors, flow meters, thermocouples, and tachometers are instrumented throughout the loop to characterize the fluid flow, valve, and turbomachinery behavior of the system. The data from the physical hardware (e.g., drum position, propellant flow rates) are input to a nuclear reactor simulator to determine the actual nuclear reactor parameters, and the data are sent back to a control algorithm to complete the control loop. The ability to conduct numerous tests of the control systems and autonomous algorithms can help validate the instrumentation and control aspects for a space nuclear reactor for every possible fault situation.

Wilson, Brandon↗

Characterizing Minimum Admissible Separation Distances in Heavy Duty Vehicle Platoons

Heavy duty (HD) vehicles platooning under highway operating conditions, have been projected to provide significant fuel economy (FE) gains based on aerodynamic drag reduction of the platooning vehicles. Realizing these benefits under real-world operating conditions have several challenges. This paper (the second as part of series) quantifies the minimum admissible separation distance between platooning vehicles in HD commercial vehicle (CV) applications. This distance must be set up such that no collision occurs with leading vehicles under all deceleration conditions. In this paper key interactions to characterize this distance are demonstrated. These include, road surface conditions, grade, inter-vehicle communication delays, air-brake lag time, vehicle speed, weight, and aerodynamic drag. It is seen that characterizing the vehicle and road dynamics will be critical in establishing required deceleration or stopping distances for each vehicle in a platoon. The results of the study also necessitate vehicle control systems that can dynamically adjust not only the separation distances but also the braking reference points based on road conditions. The narrative provides application decision personnel with a well-defined set of admissible separation distance impact factors to consider as part of their architecture selection process.

Sujan, Vivek↗

Inertia Emulation Control using Demand Response via 5G Communications

Building energy equipment is moving rapidly towards Internet of Things (IoT)-driven devices to provide consumer connectivity and device management. These device-level interfaces along with 5G communications will be leveraged to develop control architectures to engage a large number of monitoring and control devices and provide real-time and reliable energy services. Emerging 5G networks have high potential to provide the communication technology for demand response, with fast transfer speed, high reliability, and high number of connections. Guaranteed inertial response to limit frequency fluctuations is one of the main challenges in modern power systems due to the increased penetration of renewable generation, and it is largely affected by communication delays and packet losses. This paper analyzes inertial response and rate of change of frequency in a power system model with inverter-interfaced air conditioners. The control loop considers time delays and packet losses to show the need to switch to 5G networks in future smart grids.

Morovati, Samaneh↗

Reinforcement Learning-Based Secondary Control Strategy for Voltage and Frequency Regulation in Islanded Inverter-Based Microgrids

This paper presents a reinforcement learning (RL) approach for secondary voltage and frequency control in islanded inverter-based microgrids. The proposed control strategy aims to restore voltage and frequency deviations caused by the primary droop control while ensuring proper power sharing between distributed generators. The RL agent is designed to provide correction signals to the primary control, considering communication delays and system constraints. The effectiveness of the proposed control strategy is validated through simulation results in MATLAB/Simulink environment, demonstrating superior performance in maintaining voltage and frequency within the nominal values.

Rodriguez Martinez, Omar Felipe [University of Pue↗

A Multiagent Deep Reinforcement Learning-Enabled Dual-Branch Damping Controller for Multimode Oscillation

Here, this study develops a multiagent deep reinforcement learning (MADRL)-enabled framework for the decentralized cooperative control of a novel dual-branch (DB) damping controller for both low-frequency oscillation (LFO) and ultralow-frequency oscillation (ULFO). It has two branches, each of which consists of a proportional resonance (PR) and a second-order polynomial that is designed to handle target oscillation modes. To improve the robustness of the controller to system uncertainties, MADRL is developed, where multiagents are centrally trained to obtain the coordinated adaptive control policy while being executed in a decentralized manner to provide the optimal parameter setting for each controller with only local states. Comparisons with the IEEE 10-machine 39-bus system demonstrate that the proposed method achieves better robustness to uncertainties, lower communication delay, and single-point failure, as well as damping control performances for both LFO and ULFO.

97 MATHEMATICS AND COMPUTING↗

Microgrid Modeling for Stability Analysis

Here this document is a summary of a report prepared by the IEEE PES Task Force (TF) on Microgrid (MG) Dynamic Modeling, IEEE Power and Energy Society, Tech. Rep. PES-TR106, 2023. In this paper, the major issues and challenges in microgrid modeling for stability analysis are discussed, and a review of state-of-the-art modeling approaches and trends is presented. In the context of the IEEE 1547 standard, the document covers issues associated with component models for MG dynamic studies and simulations, including generator and grid modeling, full and average converter models, unbalanced and balanced system conditions, dynamic and static loads, protection requirements, and detailed and simplified controls considering communications delays, packet losses, and security issues. Considering the future integration of grids and MGs to form broad integrated networks, a discussion is presented of the use of phasor vis-à-vis electromagnetic transient simulation tools for MG dynamic stability studies, as well as modeling scale-up issues and MG equivalent models. Specifically white-, grey-, and black-box models, are presented. This TF paper and companion report constitute a modeling guide for R&D groups working on developments and standards of MGs with a focus on stability issues.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of 0.1-Hz Var Oscillations in Solar Photovoltaic Power Plants

Oscillations with very low frequency at 0.1 Hz, have been observed in voltage and var in practical solar photovoltaic (PV) systems when power exporting ramps up to a certain level. Here, this letter provides an explanation on the formation of 0.1-Hz oscillations and identifies three critical factors that lead to the oscillations: communication delay between the plant-level control and the inverter-level control, high volt/var sensitivity at a high power exporting level, and the volt-var feedback system consisting of the plant control, inverter control and the grid impact. Furthermore, a critical feature of the 0.1-Hz oscillation is also explained: why oscillations appear only in voltage and var, but not in real power.

14 SOLAR ENERGY↗

Sequential infiltration of two-photon polymerized 3D photonic crystals for mid-IR spectroscopic applications

Photonic crystals (PhCs) are spatially organized structures with lattice parameters equivalent to the operational wavelength of light. PhCs have been subject to extensive research efforts in the last two decades and are known for controlling light propagation with applications in sensing and time-delayed communication due to the slow-light phenomenon. Despite their exceptional properties, PhCs are difficult to fabricate using planar micromachining techniques due to their periodic structures. Techniques like two-photon stereolithography have been discussed for PhC fabrication in the literature, but the inherent disadvantage of poor refractive index (RI) contrast results in limited application. In this work, we present sequential infiltration synthesis performed on two-photon stereolithographically printed 3D PhCs for infiltration with zinc oxide to increase the RI of 3D PhCs. Further, finite element analysis was performed over a range of RI contrast values to study the change in photonic bandgap (PBG) with RI contrast. The transmission spectra were recorded on 3D PhCs before and after infiltration to demonstrate the change experimentally. An increase in the PBG width and absorbance is seen postinfiltration due to enhanced RI. This work presents the first, to our knowledge, sequentially infiltrated enhanced 3D PhC fabricated with two-photon stereolithography.

3D printing↗

Mitigating Phase Unbalance for Distribution Systems with High Penetrations of Solar PV (Final Technical Report)

Distribution system operators have traditionally limited unbalance among phases by maintaining similar loadings on each phase. High penetrations of distributed solar PV continually change the net loading on each phase, resulting in time-varying phase unbalances that can damage three-phase devices such as three-phase motors, violate grid codes, and increase technical losses. This project has developed several control strategies for the reactive power outputs of solar PV inverters in order to mitigate power quality issues related to phase unbalance. These control strategies include a decentralized approach that is solely based on local measurements, distributed and grouped approaches that consider subsets of loads and PV generators, and a centralized approach that leverages measurements from a variety of locations in order to compute optimal reactive power setpoints for each inverter. Variants of the controllers handle challenges relevant to practical implementations, including noisy measurements, delayed communications, and reactive power limits. Moreover, the project developed theory that provides convergence guarantees for systems with multiple interacting controllers as well as “balanceability” certificates that ensure satisfaction of phase unbalance requirements with variable loading. The controllers were integrated with NRECA’s Open Modeling Framework (omf.coop) and evaluated using actual distribution system models obtained from several NRECA member utilities. Application of the controllers results in significant improvements to phase unbalance in these test cases with decreases from base case levels of over 3% to under 0.5%, which is within the 2% IEC phase unbalance standard.

14 SOLAR ENERGY↗

Real-Sim Interface: Enabling Multi-resolution Simulation and X-in-the-Loop Development for Connected and Automated Vehicles

We report connected and automated vehicles (CAVs) can bring safety, mobility, and energy benefits to transportation systems. Ideally, CAV applications would be fully evaluated and validated prior to real-world implementation. However, many technical challenges in both software and hardware hinder the process. To comprehensively evaluate all aspects of CAV applications, an integrated evaluation environment is needed with various simulation tools from different domains. In the current literature, there lacks a well-developed interface to enable multi-resolution simulation of vehicle, traffic, virtual environment, and hardware-in-the-loop (HIL) simulation. In this work, a modular and flexible interface is developed to enable multi-resolution vehicle and traffic co-simulation for CAV applications. This interface is built upon Oak Ridge National Laboratory’s (ORNL’s) Real-Sim approach, can support various simulation tools and real-time X-in-the-loop (XIL) simulations, and is based on network communication protocols. The network communication delays are analyzed for simultaneous connection of up to 20 simulators. Then, two example applications are studied to demonstrate the potential usage of the Real-Sim interface: (1) a centralized merging scenario where the dynamics of two ego vehicles are emulated with detailed vehicle and powertrain dynamics models and (2) a signal-controller-in-the-loop (SCIL) evaluation where one intersection of the simulated traffic scenario is controlled by a physical signal controller. This Real-Sim interface is a tool that allows researchers to bring real, tangible hardware and software into simulated environments to comprehensively evaluate and support a wide variety of CAV applications.

33 ADVANCED PROPULSION SYSTEMS↗

Engine-in-the-Loop Study of a Hierarchical Predictive Online Controller for Connected and Automated Heavy-Duty Vehicles

This paper presents a cohesive set of engine-in-the-loop (EIL) studies examining the use of hierarchical model-predictive control for fuel consumption minimization in a class-8 heavy-duty truck intended to be equipped with Level-1 connectivity/automation. This work is motivated by the potential of connected/automated vehicle technologies to reduce fuel consumption in both urban/suburban and highway scenarios. The authors begin by presenting a hierarchical model-predictive control scheme that optimizes multiple chassis and powertrain functionalities for fuel consumption. These functionalities include: vehicle routing, arrival/departure at signalized intersections, speed trajectory optimization, platooning, predictive optimal gear shifting, and engine demand torque shaping. The primary optimization goal is to minimize fuel consumption, but the hierarchical controller explicitly accounts for other key objectives/constraints, including operator comfort and safe inter-vehicle spacing. This work is experimentally experimentally validated via a sequence of EIL studies intended for evaluating the computational costs and fuel savings associated with these algorithms. These EIL studies involve the closed-loop validation of the proposed control strategies, both individually and combined. These studies show that this hierarchy of algorithms is capable of running online, with the round-trip communication delay inherent in EIL simulation being one of the key factors affecting the EIL results. Moreover, the EIL studies are encouraging, both in terms of the successful hierarchical integration of the underlying algorithms and also in the resulting fuel savings seen in the EIL tests. In particular, the EIL results suggest that an aggressive overall goal of reducing vehicle fuel consumption by 15-20% or more is potentially achievable, especially in urban/suburban scenarios.

33 ADVANCED PROPULSION SYSTEMS↗

Networked HIL Simulation System for Modeling Large-scale Power Systems

This paper presents a network hardware-in-the-loop (HIL) simulation system for modeling large-scale power systems. Researchers have developed many HIL test systems for power systems in recent years. Those test systems can model both microsecond-level dynamic responses of power electronic systems and millisecond-level transients of transmission and distribution grids. By integrating individual HIL test systems into a network of HIL test systems, we can create large-scale power grid digital twins with flexible structures at required modeling resolution that fits for a wide range of system operating conditions. This will not only significantly reduce the need for field tests when developing new technologies but also greatly shorten the model development cycle. In this paper, we present a networked OPAL-RT based HIL test system for developing transmission-distribution coordinative Volt-VAR regulation technologies as an example to illustrate system setups, communication requirements among different HIL test systems, and connection mechanisms. Impacts of communication delays, information exchange cycles, and computing delays are illustrated. Simulation results show that the performance of a networked HIL test system is satisfactory.

digital twin, distribution system, co-simulation, ↗