Search NASA⌕ Search

SEARCH · Search NASA

Results for “computed tomography (CT)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Improved Interactive Medical-Imaging System

An improved computational-simulation system for interactive medical imaging has been invented. The system displays high-resolution, three-dimensional-appearing images of anatomical objects based on data acquired by such techniques as computed tomography (CT) and magnetic-resonance imaging (MRI). The system enables users to manipulate the data to obtain a variety of views for example, to display cross sections in specified planes or to rotate images about specified axes. Relative to prior such systems, this system offers enhanced capabilities for synthesizing images of surgical cuts and for collaboration by users at multiple, remote computing sites.

Ross, Muriel D.↗

Biaxial Braided Flared Cone Structural Analysis

Computed Tomography (CT) is a useful tool for performing structural analysis on polymer based materials due to its high precision and accuracy. CT data was taken of two flared cones made from carbon fiber and fiberglass. One of the flared cones is pictured below. The variation in braid angle throughout the part was measured using Avizo 3D modelling software while the variation in thickness throughout the part was determined using MATLAB. Samples of pictures from the process of each of these analyses are shown below. The overall goal of this analysis was to collect structural data relevant to future testing of the parts.

Computed Tomography↗

Finite Element Modeling for Compression Strength Prediction of Honeycomb Cores with Geometric Imperfections Measured using X-ray CT Imaging

Aluminum honeycomb cores have been used extensively in composite sandwich panels due to having high bending rigidity while maintaining low density. During manufacturing of the aluminum honeycomb, the thin metal walls are susceptible to imperfections that deviate from an ideal honeycomb shape. Computational tools to quantify imperfections and investigate their effects on quasi-static compression and impact response can inform design criteria to construct safer and lighter launch vehicle structures. This paper presents the results of a study on finite element modeling of metallic honeycomb cores (HCC) with geometric imperfections measured using X-ray Computer Tomography (CT), to predict the compression response. Finite element (FE) models are constructed with measured imperfections with appropriate boundary conditions. It is shown that the average behavior of larger 10x11 cell models can be predicted by sampling single cell models from the larger domain. Amplification of imperfections for cells at the center of sampled specimens are mode switched from the larger out-of-plane imperfection to the mode shape of the adjacent cells resulting in strengthening of the center specimens.

aluminum honeycomb↗

X-Ray Computed Tomography of Tranquility Base Moon Rock

X-ray Computed Tomography (CT) was used for the first time on the Apollo 11 Lunar Sample number 10057.30, which had been previously maintained by the White House, then transferred back to NASA under the care of Goddard Space Flight Center. Results from this analysis show detailed images of the internal structure of the moon rock, including vesicles (pores), crystal needles, and crystal bundles. These crystals, possibly the common mineral ilmenite, are found in abundance and with random orientation. Future work, in particular a greater understanding of these crystals and their formation, may lead to a more in-depth understanding of the lunar surface evolution and mineral content.

X-ray computed tomography↗

Emplacement of Shergottites in the Martian Crust Inferred From 3D Petrofabric and Crystal Size Distribution Analyses

Shergottites are mafic to ultramafic igneous rocks that represent a majority of known martian meteorites. They are subdivided into gabbroic, poikilitic, basaltic, and olivine-phyric categories based on differences in mineralogy and textures. Their geologic contexts are unknown so analyses of crystal sizes and preferred orientations have commonly been used to infer where shergottites solidified. Such environments range from subsurface cumulates to shallow intrusives to extrusive lava flows, which all have contrasting implications for interactions with crustal material, cooling histories, and potential in situ exposure at the surface. In this study, we present a novel three-dimensional (3D) approach to better understand the solidification environments of these samples and improve our knowledge of shergottites’ geologic contexts. Shape preferred orientations of most phases and crystal size distributions of late-forming minerals were measured in 3D using X-ray computed tomography (CT) on eight shergottites representing the gabbroic, poikilitic, basaltic, and olivine-phyric categories. Our analyses show that highly anisotropic, rod-like pyroxene crystals are strongly foliated in the gabbroic samples but have a weaker foliation and a mild lineation in the basaltic sample, indicating a directional flow component in the latter. Star volume distribution analyses revealed that most phases (maskelynite, pyroxene, olivine, and oxides/sulfides) preserve a foliated texture with variable strengths, and that the phases within individual samples are strongly to moderately aligned with respect to one another. In combination with relative cooling rates during the final stages of crystallization determined from interstitial oxide/sulfide crystal size distribution analyses, these results indicate that the olivine-phyric samples were emplaced as shallow intrusives (e.g., dikes/sills) and that the gabbroic, poikilitic, and basaltic samples were emplaced in deeper subsurface environments.

Martian meteorites↗

Software Method for Computed Tomography Cylinder Data Unwrapping, Re-slicing, and Analysis

A software method has been developed that is applicable for analyzing cylindrical and partially cylindrical objects inspected using computed tomography (CT). This method involves unwrapping and re-slicing data so that the CT data from the cylindrical object can be viewed as a series of 2D sheets (or flattened onion skins ) in addition to a series of top view slices and 3D volume rendering. The advantages of viewing the data in this fashion are as follows: (1) the use of standard and specialized image processing and analysis methods is facilitated having 2D array data versus a volume rendering; (2) accurate lateral dimensional analysis of flaws is possible in the unwrapped sheets versus volume rendering; (3) flaws in the part jump out at the inspector with the proper contrast expansion settings in the unwrapped sheets; and (4) it is much easier for the inspector to locate flaws in the unwrapped sheets versus top view slices for very thin cylinders. The method is fully automated and requires no input from the user except proper voxel dimension from the CT experiment and wall thickness of the part. The software is available in 32-bit and 64-bit versions, and can be used with binary data (8- and 16-bit) and BMP type CT image sets. The software has memory (RAM) and hard-drive based modes. The advantage of the (64-bit) RAM-based mode is speed (and is very practical for users of 64-bit Windows operating systems and computers having 16 GB or more RAM). The advantage of the hard-drive based analysis is one can work with essentially unlimited-sized data sets. Separate windows are spawned for the unwrapped/re-sliced data view and any image processing interactive capability. Individual unwrapped images and un -wrapped image series can be saved in common image formats. More information is available at http://www.grc.nasa.gov/WWW/OptInstr/ NDE_CT_CylinderUnwrapper.html.

Roth, Don J.↗

Computed tomography for non-destructive evaluation of composites: Applications and correlations

The state-of-the-art fabrication techniques for composite materials are such that stringent species-specific acceptance criteria must be generated to insure product reliability. Non-destructive evaluation techniques including computed tomography (CT), X-ray radiography (RT), and ultrasonic scanning (UT) are investigated and compared to determine their applicability and limitations to graphite epoxy, carbon-carbon, and carbon-phenolic materials. While the techniques appear complementary, CT is shown to provide significant, heretofore unattainable data. Finally, a correlation of NDE techniques to destructive analysis is presented.

Goldberg, B.↗

Computed tomography used in weld inspections at NASA

This paper describes an application of computed tomography (CT) for an evaluation of a series of welding-end hydraulic accumulators in use at Kennedy Space Center, which were suspected of possibly containing fatigue cracks in their welds, the failure which could result in a high-velocity or high-volume leakage of hydraulic fluid. The accumulator welds were evaluated in terms of incomplete penetration, porosity, and incomplete fusion. Out of 43 accumulators examined, six were given the ranking of 'good', i.e., having no incomplete penetration, and only slight porosity and incomplete fusion. These were selected for use in most critical locations of the hydraulic system used to load the Magellan spacecraft into the payload bay of the Space Shuttle Discovery, with the resulting successful loading and subsequent launching of the Magellan spacecraft.

Murray, S. H.↗

Computed Tomography For Inspection Of Thermistors

Computed tomography (CT) enables identification of cracked thermistors without disassembly of equipment containing them. CT unit used to scan equipment and locate thermistors. Further scans made in various radial orientations perpendicular to plane of devices to find cracks. Cracks invisible in conventional x-radiographs seen.

Schaefer, Lloyd A.↗

High resolution computed tomography of advanced composite and ceramic materials

Advanced composite and ceramic materials are being developed for use in many new defense and commercial applications. In order to achieve the desired mechanical properties of these materials, the structural elements must be carefully analyzed and engineered. A study was conducted to evaluate the use of high resolution computed tomography (CT) as a macrostructural analysis tool for advanced composite and ceramic materials. Several samples were scanned using a laboratory high resolution CT scanner. Samples were also destructively analyzed at the locations of the scans and the nondestructive and destructive results were compared. The study provides useful information outlining the strengths and limitations of this technique and the prospects for further research in this area.

Yancey, R. N.↗

Analysis, design, and experimental results for lightweight space heat receiver canisters, phase 1

Critical technology experiments have been performed on thermal energy storage modules in support of the Brayton Advanced Heat Receiver program. The modules are wedge-shaped canisters designed to minimize the mechanical stresses that occur during the phase change of the lithium fluoride phase change material. Nickel foam inserts were used in some of the canisters to provide thermal conductivity enhancement and to distribute the void volume. Two canisters, one with a nickel foam insert, and one without, were thermally cycled in various orientations in a fluidized bed furnace. The only measurable impact of the nickel foam was seen when the back and short sides of the canister were insulated to simulate operation in the advanced receiver design. In tests with insulation, the furnace to back side delta T was larger in the canister with the nickel foam insert, probably due to the radiant absorptivity of the nickel. However, the differences in the temperature profiles of the two canisters were small, and in many cases the profiles matched fairly well. Computed Tomography (CT) was successfully used to nondestructively demarcate void locations in the canisters. Finally, canister dimensional stability, which was measured throughout the thermal cycling test program with an inspection fixture was satisfactory with a maximum change of 0.635 mm (0.025 in.).

Schneider, Michael G.↗

NDE of advanced turbine engine components and materials by computed tomography

Computed tomography (CT) is an X-ray technique that provides quantitative 3D density information of materials and components and can accurately detail spatial distributions of cracks, voids, and density variations. CT scans of ceramic materials, composites, and engine components were taken and the resulting images will be discussed. Scans were taken with two CT systems with different spatial resolution capabilities. The scans showed internal damage, density variations, and geometrical arrangement of various features in the materials and components. It was concluded that CT can play an important role in the characterization of advanced turbine engine materials and components. Future applications of this technology will be outlined.

Yancey, R. N.↗

Medical Image Compression Using a New Subband Coding Method

A recently introduced iterative complexity- and entropy-constrained subband quantization design algorithm is generalized and applied to medical image compression. In particular, the corresponding subband coder is used to encode Computed Tomography (CT) axial slice head images, where statistical dependencies between neighboring image subbands are exploited. Inter-slice conditioning is also employed for further improvements in compression performance. The subband coder features many advantages such as relatively low complexity and operation over a very wide range of bit rates. Experimental results demonstrate that the performance of the new subband coder is relatively good, both objectively and subjectively.

Kossentini, Faouzi↗

Constitutive and Stability Behavior of Granular Materials Under Very Low Effective Stresses

The study of the behavior of granular materials such as sand is of great importance to the understanding of the response of foundations resting on surface and near-surface soil deposits. A clear understanding of the behavior of such materials can also provide insights into other related issues where low effective stresses are encountered such as liquefaction. The main sources of the constitutive and stability properties of cohesionless granular materials is interparticle friction, which in turn under low confinement stress levels is strongly affected by gravitational body forces under terrestrial (1 gravity) conditions. Under moderate-to-high stress levels, the influence of gravity on the behavior of experiments may not be pronounced and therefore the test results in a terrestrial environment may be acceptable for engineering purposes. However, the conduct of experiments on granular materials under very low stress levels and under quasi-static conditions can only be performed in a microgravity environment. A series of displacement-controlled cyclic triaxial compression experiments were performed in a SPACEHAB module on the Space Shuttle during the STS-79 mission to Mir in September, 1996, and the STS-89 mission in January, 1998. The experiments were conducted on six right cylindrical specimens 75 mm in diameter and 150 mm long at effective confining pressures of 0.05, 0.52 and 1.30 kPa. The results show very high peak strength friction angles in the range of 47.6 to 70.0 degrees, which are mainly due to overconsolidation and grain interlocking effects. It was observed that the residual strength levels were in the same range as that observed at higher confining stress levels. The dilatancy angles were unusually high in the range of 30 to 31 degrees. All specimens display substantial initial stiffnesses and elastic moduli during unloading and reloading events, which are nearly an order of magnitude higher than conventional theories predict. A periodic instability phenomenon which appears to result from buckling of multiple internal arches and columnar systems, augmented by stick-slips was observed in the experiments. Computed Tomography (CT) measurements revealed valuable data about the internal fabric and the specimens deformation patterns. Uniform diffuse bifurcation with multiple radial shear bands was observed in the specimens tested in a microgravity environment. In the axial direction, two major conical surfaces were developed. Spatial nonsymmetrical deformations were observed in specimens tested in terrestrial laboratory.

Alshibli, Khalid A.↗

Assessment of Localized Deformations in Sand Using X-Ray Computed Tomography

The internal fabric and localized deformation patterns of triaxial sand specimens were investigated using Computed Tomography (CT). Three displacement-controlled, conventional, drained axisymmetric (triaxial) experiments were conducted on dry Ottawa sand specimens at very low effective confining stresses (0.05, 0.52, and 1.30 kPa) in a microgravity environment aboard the Space Shuttle during the NASA STS-79 mission. CT scanning was p'erformed on these flight specimens, as well as on an uncompressed specimen and a specimen tested in a terrestrial laboratory at 1.30 kPa effective confining stress. CT demonstrated high accuracy in detecting specimen inhomogeneity and localization patterns. Formation of deformation patterns is dependent on the effective confining stress and gravity. Multiple symmetrical radial shear bands were observed in the specimens tested in a microgravity environment. In the axial direction, two major conical surfaces were developed. Nonsymmetrical spatial deformation was observed in the 1-G specimen. Analysis tools were developed to quantify the spatial density change. Void ratio variation within and outside the shear bands was calculated and discussed.

Alshibli, Khalid A↗

Quantitative Computer Tomography for Determining Composition of Microgravity and Ground Based Solid Solutions

Advances in x-ray Computer Tomography (CT) have been led by the medical profession, and by evaluation of industrial products, particularly castings. Porosity can readily be determined as a function of the density of a material, and CT is thus an industrially important NDE tool. Providing high purity, 100% dense standards of pure elements and compounds can be fabricated, the composition of solid solution alloys can be determined by measuring the CT number, which is a function of the absorption of the sample. Average densities across slices 1 mm thick can generally be determined to better than 1 percent. With present technology this spatial sensitivity is less than ideal, but important benefits can nevertheless be obtained by using CT, particularly single crystals, prior to making any destructive assault upon the sample. The sample can in fact be examined prior to removal from the mold within which it has been grown and, in the cases of microgravity flight samples, before removal from the cartridge assembly. This greatly assists the researcher in the characterization of the products, particularly as a guide to cutting and sampling. Examples of work with germanium-silicon alloys and mercury cadmium telluride taken with a radioactive cobalt source will be demonstrated.

Gillies, D. C.↗

Mechanics of Granular Materials (MGM) Microgravity Experiment

The second series of MGM experiment was conducted during the STS-89 mission in January 1998. The experiment was previously flow on Atlantis's STS-79 mission in September 1996. Six displacement-controlled, drained triaxial compression experiments were performed at very low effective confining stresses. The confining stresses were in the ranges 0.05, 0.52 and 1.30 kPa. Three experiments were subjected to monotonic loading and unloading cycles while the other three experiments were subjected to cyclic loading. The results show very high peak strength friction angles in the range of 47.6 to 70.0 degrees, which are mainly due to overconsolidation and grain interlocking effects. It was observed that the residual strength levels in the monotonic loading experiments were in the same range as that observed at higher confining stress levels. The dilatancy angles were unusually high in the range of 30 to 31 degrees. All specimens display substantial initial stiffnesses and elastic moduli during unloading and reloading events, which are nearly an order of magnitude higher than conventional theories predict. A periodic instability phenomenon which appears to result from buckling of multiple internal arches and columnar systems, augmented by stick-slips was observed in the experiments. Computed Tomography (CT) measurements revealed valuable data about the internal fabric and the specimens deformation patterns. Uniform diffuse bifurcation with multiple radial shear bands was observed in the specimens tested in a microgravity environment. In the axial direction, two major conical surfaces were developed. Spatial nonsymmetrical deformations were observed in specimens tested in terrestrial laboratory.

Alshibli, Khalid A.↗

Assessment of Internal Fabric of Particulate Materials

Particle arrangement and distribution within a soil matrix has long been recognized as having significant influence on the mechanical behavior of cohesionless soils. It is well known that two soil specimens having the same grain type (e.g., quartz, feldspar, etc.), same grain size distribution and relative density (or void ratio) can display completely different mechanical behavior. Because of the different fabric configurations in the otherwise similar specimens, they are likely to have different mechanical properties such as stress-strain response, anisotropy, dilatancy, etc. Soil Fabric is defined as the arrangement of particles, particle groups and associated pore space. In the literature, fabric analysis techniques are mainly classified as destructive (e.g., specimen stabilization, thin-sectioning, and microscopy), and nondestructive techniques (e.g., magnetic resonance imaging, ultrasonic testing, x-ray radiography, and computed tomography). Quantifying the void ratio and its distribution is the main parameter used to describe the fabric of particulate materials. This paper presents a comprehensive literature review of fabric analysis techniques applied to particulate materials. In addition, the results of a comprehensive investigation to quantify void ratio of sand specimens will be presented and discussed. The sand used in the experiments in a natural, uniform rounded to sub-rounded silica sand known as F-75 banding sand with mean particle size of 0.22 mm. Uniform specimens and specimens subjected to different axial-strain levels tested under triaxial and biaxial conditions are examined to evaluate void ratio evolution and its distribution using destructive thin-sectioning and nondestructive Computed Tomography (CT) techniques. Details of a new innovative polygon generation technique called Voronoi tessellation used to quantify void ratio of microscopic images of sand grains will be presented and compared to classical Oda's method. Finally, frequency distribution of void ratio calculated using CT analysis will be presented and discussed.

Alshibi, Khalid A.↗