Search NASA⌕ Search

SEARCH · Search NASA

Results for “computed tomography (CT)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

First-In-Human Validation of CT-Based Proton Range Prediction Using Prompt Gamma Imaging in Prostate Cancer Treatments

Uncertainty in computed tomography (CT)-based range prediction substantially impairs the accuracy of proton therapy. Direct determination of the stopping-power ratio (SPR) from dual-energy CT (DECT) has been proposed (DirectSPR), and initial validation studies in phantoms and biological tissues have proven a high accuracy. However, a thorough validation of range prediction in patients has not yet been achieved by any means. Here, we present the first systematic validation of CT-based proton range prediction in patients using prompt gamma imaging (PGI).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk of hematological malignancies from CT radiation exposure in children, adolescents and young adults

Over one million European children undergo computed tomography (CT) scans annually. Although moderate- to high-dose ionizing radiation exposure is an established risk factor for hematological malignancies, risks at CT examination dose levels remain uncertain. Here we followed up a multinational cohort (EPI-CT) of 948,174 individuals who underwent CT examinations before age 22 years in nine European countries. Radiation doses to the active bone marrow were estimated on the basis of body part scanned, patient characteristics, time period and inferred CT technical parameters. We found an association between cumulative dose and risk of all hematological malignancies, with an excess relative risk of 1.96 (95% confidence interval 1.10 to 3.12) per 100 mGy (790 cases). Similar estimates were obtained for lymphoid and myeloid malignancies. Results suggest that for every 10,000 children examined today (mean dose 8 mGy), 1–2 persons are expected to develop a hematological malignancy attributable to radiation exposure in the subsequent 12 years. Our results strengthen the body of evidence of increased cancer risk at low radiation doses and highlight the need for continued justification of pediatric CT examinations and optimization of doses.

60 APPLIED LIFE SCIENCES↗

System and method for identifying objects of interest in images based on likelihood map decluttering

An automatic threat recognition system and method is disclosed for scanning the x-ray CT image of an article to identify the objects of interest (OOIs) contained within the article, which are otherwise not always quickly apparent or discernable to an individual. The system uses a computer to receive information from two-dimensional (2D) image slices from a reconstructed computed tomography (CT) scan image and to produce a plurality of voxels for each slice of the 2D image. The computer analyzes the voxels to create a likelihood map (LM) representing likelihoods that voxels making up the CT image are associated with a material of interest (MOI). The computer further analyzes the LM to construct neighborhoods of voxels within the LM, and classifies each voxel neighborhood based on its features, thereby decluttering the LM to facilitate the process of connecting voxels of a like MOI together to form segments. The computer classifies each candidate segment based on its features, thereby identifying those segments that correspond to objects of interest.

Paglieroni, David W.↗

Topological analysis of X-ray CT data for the recognition and trending of subtle changes in microstructure under material aging

X-ray computed tomography (CT) is an established non-destructive tool for 3D imaging of multiphasic composites. Numerous applications of X-ray CT in medical diagnosis and materials characterization have been reported, many involving field-specific innovations in the imaging technology itself. Yet, quantitative summarization to link image features to properties of interest has been rare. Here we address this issue by employing state-of-the-art technics in scalar field topology for the summarization of X-ray CT images of an example biphasic system. By varying processing-parameters we create different microstructures, evolve them through accelerated thermal aging, CT-image them pre- and post-aged, and demonstrate the ability of our image summarization method to systematically track process- and age-related changes, which can often be very subtle. A novel aspect of the algorithm involves recognition over multiple resolution levels, which provides deeper insight into the pattern relationship between grain-like features and their neighbors. The method is general, adaptable to diverse image reconstruction methods and materials systems, and particularly useful in applications where practical constraints on the sample-size limits the reliable use of more complex models, e.g., convolutional neural networks.

36 MATERIALS SCIENCE↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhancing synchrotron radiation micro-CT images using deep learning: an application of Noise2Inverse on bone imaging

In bone-imaging research, in situ synchrotron radiation micro-computed tomography (SRµCT) mechanical tests are used to investigate the mechanical properties of bone in relation to its microstructure. Low-dose computed tomography (CT) is used to preserve bone's mechanical properties from radiation damage, though it increases noise. To reduce this noise, the self-supervised deep learning method Noise2Inverse was used on low-dose SRµCT images where segmentation using traditional thresholding techniques was not possible. Simulated-dose datasets were created by sampling projection data at full, one-half, one-third, one-fourth and one-sixth frequencies of an in situ SRµCT mechanical test. After convolutional neural networks were trained, Noise2Inverse performance on all dose simulations was assessed visually and by analyzing bone microstructural features. Visually, high image quality was recovered for each simulated dose. Lacunae volume, lacunae aspect ratio and mineralization distributions shifted slightly in full, one-half and one-third dose network results, but were distorted in one-fourth and one-sixth dose network results. Following this, new models were trained using a larger dataset to determine differences between full dose and one-third dose simulations. Significant changes were found for all parameters of bone microstructure, indicating that a separate validation scan may be necessary to apply this technique for microstructure quantification. Noise present during data acquisition from the testing setup was determined to be the primary source of concern for Noise2Inverse viability. While these limitations exist, incorporating dose calculations and optimal imaging parameters enables self-supervised deep learning methods such as Noise2Inverse to be integrated into existing experiments to decrease radiation dose.

Obata, Yoshihiro (ORCID:0000000303659129)↗

Different CT slice thickness and contrast‐enhancement phase in radiomics models on the differential performance of lung adenocarcinoma

Abstract Background To investigate the effects of computed tomography (CT) reconstruction slice thickness and contrast‐enhancement phase on the differential diagnosis performance of radiomic signature in lung adenocarcinoma. Methods A total of 187 patients who had been pathologically confirmed with lung adenocarcinoma and nonadenocarcinoma were divided into a training cohort ( n = 149) and validation cohort ( n = 38). All the patients underwent contrast‐enhanced CT and the images were reconstructed with different slice thickness. The radiomic features were extracted from different slice thickness and scan phase. The logistic regression (LR) algorithm was used to build a machine learning model for each group. The area under the curve (AUC) obtained from the receiver operating characteristic (ROC) curve and DeLong test was used to evaluate its discriminating performance. Results Finally, 34 image features and five semantic features were selected to establish a radiomics model. Based on the three contrast‐enhanced CT phases and four reconstruction slice thickness, 12 groups of radiomics models showed good discrimination ability with the AUCs range from 0.9287 to 0.9631, sensitivity range from 0.8349 to 0.9083, specificity range from 0.825 to 0.925 in the training group. Similar results were observed in the validation group. However, there was no statistical significance between the different CT scan phase groups and different slice thickness ( p > 0.05). Conclusions The radiomic analysis of contrast‐enhanced CT can be used for the differential diagnosis of lung adenocarcinoma. Moreover, different slice thickness and contrast‐enhanced scan phase did not affect the discriminating ability in the radiomics models.

Wang, Yang↗

Low-Cost X-Ray CT System for Imaging of Roots

The goal of this project was to develop and demonstrate an innovative, low cost, field deployable, stationary 3D x-ray computed tomography (CT) system that will image total root phenotypes with a micron size resolution at a throughput of hundreds of plants per cycle. This system is based on UHV’s unique low cost linear x-ray tube technology and sophisticated reconstruction & image segmentation algorithms developed at University of Massachusetts, Lowel and University of Nottingham; and was tested for several types of soils at University of Wisconsin and Texas A&M University. Currently, no technologies exist that have been designed to image roots in complex media such as agricultural field conditions. Due to its small size, high resolution & fast imaging of fine roots, low power consumption, large penetration depth (i.e. ability to see through several feet of soil) and ease of field deployability, this CT system will increase the speed and efficacy of discovery, field translation, and deployment of improved crops and systems that improve soil carbon accumulation and storage, decrease N2O emissions, and improve water efficiency leading towards advancements that could mitigate 10% of the total US Greenhouse gases. This degree of imaging in the field has never been available and would be invaluable to scientists in understanding how environmental conditions and phenotypic variations contribute to carbon deposition through root development.

54 ENVIRONMENTAL SCIENCES↗

Assessing pore network heterogeneity across multiple scales to inform CO2 injection models

Geologic heterogeneity is a key feature that must be considered when translations of scaled data are performed. This paper presents the assessment of geologic heterogeneity using a multiscale workflow that includes image analysis-based methods coupled with well log analysis to provide data in which fractals and machine learning methods estimate the carbon dioxide (CO 2 ) storage resource potential of a reservoir. The heterogeneity of rock properties of the complex Bell Creek reservoir in Montana, USA, was explored at the pore scale (~nm to mm), core scale (~mm to m), and well scale (~cm to m). The data used in this study included advanced image analysis of micro-CT (computed tomography) images (pore scale), thin sections (pore scale), plugs and core images (core scale) and well logs (well scale). The micro-CT images were segmented using a U-net segmentation approach into objects of pores and grains. Further, the segmented images were reconstructed into subvolumes of different sizes. Physical properties (porosity and permeability) and fractal dimensions were calculated for the various subvolumes, and Lorenz coefficient (Lc) values, a single parameter to describe the degree of heterogeneity within a pay zone section, were calculated from thin-section images and well logs. Porosity and fractal dimension values were used to estimate the 188-µm threshold of representative elementary volume (REV) in this study. Both the Lc and fractal dimension values were found to be negatively correlated. When these two parameters are combined, it is possible to discern differences in the complex porous networks of the samples analyzed in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model-based reconstruction for enhanced x-ray CT of dense tri-structural isotropic particles

Tri-structural isotropic (TRISO) fuel particles are a key component of next generation nuclear fuels. Using x-ray computed tomography (CT) to characterize TRISO particles is challenging because of the strong attenuation of the x-ray beam by the uranium core, leading to severe photon starvation in a substantial fraction of the measurements. Furthermore, the overall acquisition time for a high-resolution CT scan can be very long when using conventional laboratory-based x-ray systems and reconstruction algorithms. Specifically, when analytic methods such as the Feldkamp–Davis–Kress (FDK) algorithm are used for reconstruction, it results in severe streak artifacts and noise in the corresponding 3D volume, which makes subsequent analysis of the particles challenging. In this paper, we develop and apply model-based image reconstruction (MBIR) algorithms to improve the quality of CT reconstructions for TRISO particles to facilitate better characterization. We demonstrate that the proposed MBIR algorithms can significantly suppress artifacts with minimal pre-processing compared to conventional approaches. We also demonstrate that the proposed MBIR approach can obtain high-quality reconstruction compared to the FDK approach even when using a fraction of the typically acquired measurements, thereby enabling dramatically faster measurement times for TRISO particles.

Venkatakrishnan, Singanallur↗

TP099-CT-800DR Comparison Between SIRZ-2 and Surface Fit Method ($ρ_{e},Ζ_{e}$) Estimation

The primary objective of this test plan is to acquire dual-energy computed tomography (CT) data of 33 well-known specimens using the Leidos Reveal CT-80DR+ baggage scanner housed at LLNL (hereafter referred to as CT-80DR). These data sets will allow us to compare, for each specimen, the accuracy and precision of electron density ($ρ_{e}$) and effective atomic number ($Z_{e}$) estimates obtained from two different algorithmic methods— from TSL’s surface fits and from LLNL’s SIRZ-2 decomposition. A secondary objective is to determine how often it is necessary to acquire CT-80DR spectral response information.

42 ENGINEERING↗

Physics guided machine learning for multi-material decomposition of tissues from dual-energy CT scans of simulated breast models with calcifications

We introduce a physics guided data-driven method for image-based multi-material decomposition for dual-energy computed tomography (CT) scans. The method is demonstrated for CT scans of virtual human phantoms containing more than two types of tissues. The method is a physics-driven supervised learning technique. We take advantage of the mass attenuation coefficient of dense materials compared to that of muscle tissues to perform a preliminary extraction of the dense material from the images using unsupervised methods. We then perform supervised deep learning on the images processed by the extracted dense material to obtain the final multi-material tissue map. The method is demonstrated on simulated breast models with calcifications as the dense material placed amongst the muscle tissues. The physics-guided machine learning method accurately decomposes the various tissues from input images, achieving a normalized root-mean-squared error of 2.75%.

Gopalakrishnan Meena, Murali↗

A Computed Tomography Automation Architecture Developed from a Comprehensive Literature Review

This paper presents a literature review on techniques related to the computed tomography procedure that incorporate automation elements in their research investigations or industrial applications. Computed tomography (CT) is a non-destructive testing (NDT) technique in that the imaging and inspection are performed without damaging the sample, allowing for additional or repeated analysis if necessary. The reviewed literature is organized based on the steps associated with a general NDT task in order to define an end-to-end computed tomography automation architecture. The process steps include activities prior to image collection, during the scan, and after the data are collected. It further reviews efforts related to repeating this process based on a previous scan result. By analyzing the multiple existing but disparate efforts found in the literature, we present a framework for fully automating NDT procedures and discuss the remaining technical gaps in the developed framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic Screening of COVID-19 Disease Based on Chest CT and RT-PCR for Cancer Patients Undergoing Radiation Therapy in a Coronavirus French Hotspot

Patients with cancer are presumed to be more vulnerable to COVID-19. We evaluated a screening strategy combining chest computed tomography (CT) and reverse-transcription polymerase chain reaction (RT-PCR) for patients treated with radiation therapy at our cancer center located in a COVID-19 French hotspot during the first wave of the pandemic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Segmentation of Porous Thermal Spray Material CT Scans with Geometric Uncertainty Estimation

Thermal sprayed metal coatings are used in many industrial applications, and characterizing the structure and performance of these materials is vital to understanding their behavior in the field. X-ray Computed Tomography (CT) machines enable volumetric, nondestructive imaging of these materials, but precise segmentation of this grayscale image data into discrete material phases is necessary to calculate quantities of interest related to material structure. In this work, we present a methodology to automate the CT segmentation process as well as quantify uncertainty in segmentations via deep learning. Neural networks (NNs) are shown to accurately segment full resolution CT scans of thermal sprayed materials and provide maps of uncertainty that conservatively bound the predicted geometry. These bounds are propagated through calculations of material properties such as porosity that may provide an understanding of anticipated behavior in the field.

36 MATERIALS SCIENCE↗

Automated segmentation of porous thermal spray material CT scans with predictive uncertainty estimation

Abstract Thermal sprayed metal coatings are used in many industrial applications, and characterizing the structure and performance of these materials is vital to understanding their behavior in the field. X-ray computed tomography (CT) enables volumetric, nondestructive imaging of these materials, but precise segmentation of this grayscale image data into discrete material phases is necessary to calculate quantities of interest related to material structure. In this work, we present a methodology to automate the CT segmentation process as well as quantify uncertainty in segmentations via deep learning. Neural networks (NNs) have been shown to excel at segmentation tasks; however, memory constraints, class imbalance, and lack of sufficient training data often prohibit their deployment in high resolution volumetric domains. Our 3D convolutional NN implementation mitigates these challenges and accurately segments full resolution CT scans of thermal sprayed materials with maps of uncertainty that conservatively bound the predicted geometry. These bounds are propagated through calculations of material properties such as porosity that may provide an understanding of anticipated behavior in the field.

Martinez, Carianne↗

Quantifying Trapped Powder in Electron Beam Powder Bed Fusion

Abstract Electron beam powder bed fusion (PBF-EB) shows great potential for manufacturing complex parts including those with internal cavities for heat exchanger, manifold systems, or energy absorption purposes. PBF-EB allows for the manufacture of channel geometries without the need for support structures. Due to the nature of the powder spreading process, powder feedstock is often trapped in intentionally manufactured cavities. This trapped powder can often be difficult to remove and can disturb the intended flow of fluid through the cavity or damage downstream components in its use case. These trapped powder particles present a risk of contamination and component failure if not completely evacuated. Ti6Al4V is a choice material for aerospace applications due to its high strength to weight ratio and its composition as a nonferrous metal; however, in weight sensitive applications excess entrapped powders or powders loosely attached to the surface could cause undesirable weight increases. The inherent spreading process of PBF-EB is different than laser powder bed fusion (PBF-LB) in its operational temperature, sintering. In addition, PBF-EB is less commonly studied in literature compared to its PBF-LB counterpart, and as a result the complexity of the semi-sintered powder and its spreading behavior are not well understood. Prior work has investigated the difficulty in removing trapped powder from PBF-EB, but these studies do not address how to quantify the amount of trapped powder in the cavity. Thus, an accurate method to measure the amount of trapped powder in the cavity must be investigated. In this work, Ti6Al4V coupons were manufactured with horizontal and vertical cavities of three different sizes. Archimedes testing allows for the determination of density differences caused by porosity and trapped powders by measuring mass and volumetric dispersion. Computed tomography (CT) is well suited for segmenting the internal structure and features of a part and has been studied for applications including voids, porosity, and dross. Thus, CT was explored as a method for evaluating trapped powder content in this work. The volumetric representation of the segmentation of the reconstructed CT volume can vary greatly depending on the input filter and thresholding methods. In this study, four different types of segmentation approaches were evaluated to determine the best approach for segmenting the volume as compared to an operator labeled ground truth. The percentage density results from the Archimedes testing were compared to the volumetric percent density from the computed tomography approach. Differences in packing density between two different internal channel features were investigated. Overall, this work sought to validate the use of computed tomography for the detection of trapped powders and present a framework for volumetric segmentation.

Johnstone, Brian↗

IMPACT 2025-2026 Internship Poster

At Sandia National Laboratories, I developed a C++ program that converts printed circuit boards(PCB) and integrated circuits(IC) design files to be compatible for computed tomography (CT) simulations through Monte Carlo methods.

97 MATHEMATICS AND COMPUTING↗