Search NASA⌕ Search

SEARCH · Search NASA

Results for “concentrator PV modules”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Renewable Energy Potential (reV) Model: A Geospatial Platform for Technical Potential and Supply Curve Modeling

The Renewable Energy Potential (reV) model is a platform for detailed assessment of renewable energy (RE) resources and their geospatial intersection with grid infrastructure and land use characteristics. The reV model currently supports photovoltaic (PV), concentrating solar power (CSP) and land-based wind turbine technologies. Modules in the reV framework function at different spatial and temporal resolutions, allowing for assessment of resource potential, technical potential and supply curves at varying levels of detail. The platform runs on NREL's High Performance Computing system, providing scalable and efficient performance from a single location all the way up to continental scales, for a single year or decades of time series resource data. Coupled with NREL's System Advisor Model (SAM), reV supports resource assessment from 5-minute to hourly temporal resolution and provides for analysis of long-term (i.e., year-on-year) variability of RE generation (e.g., interannual variability and exceedance probabilities). Technical potential is measured as a function of resource potential and limitations put on developable land area defined by the user. For example, the user can limit development by land ownership, terrain, land use/cover, and urban areas, as well as custom inputs. Technology, grid interconnection and operation costs, based on the latest market data and future projections, are also embedded in the model. The supply curve module is a spatial sorting algorithm based on plant siting, grid interconnection cost, and regional competition, which provides a geographically discrete estimate of levelized cost of electricity (LCOE) and supply (i.e., capacity) for specific renewable technologies. The reV model currently provides broad coverage across North America, South and Central Asia, South America and South Africa to inform national- and international-scale analyses as well as regional infrastructure and deployment planning.

13 HYDRO ENERGY↗

Feasibility and Reliability of a Single Layer Polymeric PV Backsheet in White, Transparent, or Luminescent Concentrator Options

A single layer polymeric backsheet material has been evaluated for use in silicon PV modules and as a luminescent solar collector. Physical and optical properties of the backsheet have been examined after damp heat, thermal cycling, and UV exposure for two different polymeric grades and three different pigment options including white, transparent, and photo-luminescent. As the importance of developing a white backsheet that is cost-effective, recyclable, and reliable is evident, the increased availability and use of bifacial cells is bound to increase the demand for transparent backsheets as well. In today's market, the cost of a clear backsheet is significantly higher than a white backsheet which is motivation for research and development of new material options in this field. Results from these extensive tests reveal the need for continued research in white pigments and positive results in transparent and luminescent backsheet options.

14 SOLAR ENERGY↗

Quantifying Optical Loss of High-Voltage Degradation Modes in PV Modules Using Spectral Analysis [Slides]

The direct current bias for photovoltaic (PV) modules interconnected in series-strings may include both high voltage negative ("HV-") and positive ("HV+") polarity with respect to the electrical ground. Multiple degradation modes, resulting in quantifiable optical loss, were found to occur during HV-/HV+ sequential stress, including: corrosion of the external glass surface, encapsulant delamination (at its interfaces with the glass and the PV cell), internal haze formation (resulting from a chemical interaction between the glass and the encapsulant), corrosion and migration of the gridlines, and corrosion of the silicon nitride (SixNy) antireflective coating on the cell. The effects of these separate modes were examined using monolithic (e.g., glass or PV cell) and laminated-coupon (glass/encapsulant/glass or glass/encapsulant/cell/encapsulant/backsheet) specimens. Characterizations during and after unbiased accelerated testing at 85 degrees C/85% relative humidity included: spectrophotometry, optical microscopy, electron microscopy, and ellipsometry. For some module components (i.e., the glass and the SixNy coating), the optical performance was determined through iterative analysis of empirical measurements. Concentrating on just their spectral effect, a novel model was then developed to estimate the transfer of light to the PV cell and the return of light from the PV module with simultaneous degradation mechanisms, which was compared to a mini-module previously subjected to HV-/HV+ stress. The model suggests one-third of the current loss observed for the mini-module can be attributed to the optical degradation of the packaging materials. The dominant degradation modes include encapsulant delamination and corrosion of the SixNy coating. Recommendations are given so that the optical model may be improved relative to accelerated testing and validated relative to field aging.

14 SOLAR ENERGY↗

Development of Tools Training and Outreach to Address Solar Glare and Flux-Related Avian Impacts

Millions of dollars and significant resources are being spent by developers of utility-scale solar photovoltaic (PV) and concentrating solar power (CSP) plants to address federal and local requirements regarding glare and avian hazards. Solar glare can occur from the glass surfaces of PV modules and from mirrors in CSP systems, which can produce safety and health risks for pilots, motorists, and residents located near these systems. In addition, concentrated solar flux at CSP plants has the potential to singe birds as they fly through regions of high solar flux. This work will develop tools to characterize and mitigate these potential hazards, which will address regulatory policies and reduce costs and efforts associated with the proposed deployment of gigawatts of solar energy systems throughout the nation. The development of standardized and publicly available tools to address these regulatory policies and ensure public and environmental safety is an appropriate role for the government.

14 SOLAR ENERGY↗

Quantifying optical loss of high-voltage degradation modes in photovoltaic modules using spectral analysis

The direct current bias for photovoltaic (PV) modules interconnected in series-strings may include both high voltage negative (“HV-”) and positive (“HV+”) polarity with respect to the electrical ground. Multiple degradation modes, resulting in quantifiable optical loss, were found to occur during HV-/HV+ sequential stress, including corrosion of the external glass surface, encapsulant delamination (at its interfaces with the glass and the PV cell), internal haze formation (resulting from a chemical interaction between the glass and the encapsulant), corrosion and migration of the gridlines, and corrosion of the silicon nitride (Si x N y ) antireflective coating on the cell. The effects of these separate modes were examined using monolithic (e.g., glass or PV cell) and laminated-coupon (glass/encapsulant/glass or glass/encapsulant/cell/encapsulant/backsheet) specimens. Characterizations during and after unbiased accelerated testing at 85°C/85% relative humidity included spectrophotometry, optical microscopy, electron microscopy, and ellipsometry. For some module components (i.e., the glass and the Si x N y coating), the optical performance was determined through iterative analysis of empirical measurements. Concentrating on just their spectral effect, a novel model was then developed to estimate the transfer of light to the PV cell and the return of light from the PV module with simultaneous degradation mechanisms, which was compared with a mini-module previously subjected to HV-/HV+ stress. Here the model suggests that one third of the current loss observed for the mini-module can be attributed to the optical degradation of the packaging materials. The dominant degradation modes include encapsulant delamination and corrosion of the Si x N y coating. Recommendations are given so that the optical model may be improved relative to accelerated testing and validated relative to field aging.

14 SOLAR ENERGY↗

Artificial Replication of Field Soiling Losses on PV Modules

In this paper, we experimentally demonstrate an improved replication of field soiling losses using an indoor artificial soiling chamber and tests on anti-soiling coated PV modules and coupons. The primary focus is to use site-specific soil collected from module surface and replicate the natural soiling processes including dust concentration in the air, slow and gradual dust accumulation and sedimentation on the module surface during the dominant soiling season of the site of interest. The experiments were conducted on two sample sets having different anti-soiling properties. The first set contains commercial modules with two different surface properties retrieved after three years of exposure from a single PV plant in a mid-Atlantic location; the other set contain glass coupons with three different coating materials that were installed and exposed over 4 months, at Lemoore, California. Major field-representative factors considered here for the close replication in the chamber include: the use of dust collected from modules surfaces at the outdoor sites to give the same dust chemistry; dust particle size distribution and concentration; the charge size of dust (< 0.15 g per injection); field humidity, and module temperature. The effectiveness of antisoiling coatings (or surface properties) for both sample sets were ranked in the artificial testing and were found to be closely matching with the field rank orders of the respective sites and sample sets. This paper provides the rank ordering results to objectively demonstrate the replication of field soiling losses in the artificial soiling chamber.

artificial soiling↗

PV Cell and Module Calibrations at NREL

NREL has equipment to measure any conceivable cell or module technology. The lack of standards for low concentration modules complicates matters. Spectrally adjustable simulators are critical for more than three junctions. NREL's 10-channel fiber optic simulator has shown that the light can be set for each junction within 1% of what it would be under the reference spectrum for up to a five-junction cell. Uncertainty in module simulators dominated by spatial nonuniformity for calibration labs. Manufacturers can mitigate this error by using matched reference modules instead of cells.

14 SOLAR ENERGY↗

PV Lifetime Project (2021 NREL Annual Report)

DOE's PV Lifetime project was initiated in 2016 with the goal of accurately characterizing the early-life evolution of photovoltaic (PV) field performance. Different PV cell and module technologies result in different initial performance loss rates due to effects like light-induced degradation (LID) and light & elevated temperature-induced degradation (LeTID). To accurately characterize the initial field performance loss requires the use of high-accuracy indoor IV curve measurements at standard test conditions. Therefore, PV modules involved in this study are removed from the field once or twice per year and brought indoors for measurement. Current samples deployed and monitored in this way include Jinko Solar (2016), Trina Solar (2016), Hanwha Q-Cells (2017), Panasonic (2018), LG (2018), Canadian Solar (2018), Mission Solar (2019). More recently, modules from Sunpreme (2019), and LONGi (2020) have been deployed but not yet analyzed. Overall annual performance loss rates are as follows: our first modules to be deployed (Jinko and Trina) have annual median performance loss rate between -0.4%/yr and -0.9%/yr, mainly concentrated in the first year. The QCells mono-PERC and multi-PERC modules have an annual degradation rate of -0.76%/yr and -0.69%/yr respectively, also concentrated in the first year of operation. Panasonic and LG modules displayed negligible performance loss in the past two years, at 0.1%/yr and -0.0%/yr respectively. They also were the only modules with initial IV curve measurements consistently above the nameplate rating. Possibly relatedly, these are also the only two N-type silicon module types analyzed so far. Canadian Solar multi-PERC modules demonstrated a -1.3%/yr degradation rate which actually accelerated in the past year, so this will be a module type to monitor in future years. Mission Solar modules exhibited strong recoverable performance loss, consistent with LeTID susceptibility. (The same is true for the Jinko JKM260 module type). Annual performance loss actually showed improvement in time at +0.3%/yr after 2 years in the field, although the module initially was measured at 3% below nameplate rating. These modules could therefore be experiencing a form of post-LeTID recovery. Initial measurements have been conducted on the next two module types - Sunpreme n-HIT and LONGi bifacial mono-PERC. We will report on initial year-1 performance change for these modules in the next PV Lifetime annual report. For the remaining modules, an additional year of field exposure will provide greater certainty in annual degradation rates, particularly for those with degradation concentrated in the initial year of field deployment.

14 SOLAR ENERGY↗

Solar dynamic power for space station freedom

The Space Station Freedom Program is presently planned to consist of two phases. At the completion of Phase 1, Freedom's manned base will consist of a transverse boom with attached manned modules and 75 kW of available electric power supplied by photovoltaic (PV) power sources. In Phase 2, electric power available to the manned base will be increased to 125 kW by the addition of two solar dynamic (SD) power modules, one at each end of the transverse boom. Power for manned base growth beyond Phase 2 will be supplied by additional SD modules. Studies show that SD power for the growth eras will result in life cycle cost savings of $3 to $4 billion when compared to PV-supplied power. In the SD power modules for Space Station Freedom, an offset parabolic concentrator collects and focuses solar energy into a heat receiver. To allow full power operation over the entire orbit, the receiver includes integral thermal energy storage by means of the heat of fusion of a salt mixture. Thermal energy is removed from the receiver and converted to electrical energy by a power conversion unit (PCU) which includes a closed brayton cycle (CBC) heat engine and an alternator. The receiver/PCU/radiator combination will be completely assembled and charged with gas and cooling fluid on Earth before launch to orbit. The concentrator subassemblies will be pre-aligned and stowed in the orbiter bay before launch. On orbit, the receiver/PCU/radiator assembly will be installed as a unit. The pre-aligned concentrator panels will then be latched together and the total concentrator attached to the receiver/PCU/radiator by the astronauts. After final electric connections are made and checkout is complete, the SD power module will be ready for operation.

Labus, Thomas L.↗

Solar dynamic power for Space Station Freedom

The Space Station Freedom Program is presently planned to consist of two phases. At the completion of Phase 1, Freedom's manned base will consist of a transverse boom with attached manned modules and 75 kW of available electric power supplied by photovoltaic (PV) power sources. In Phase 2, electric power available to the manned base will be increased to 125 kW by the addition of two solar dynamic (SD) power modules, one at each end of the transverse boom. Power for manned base growth beyond Phase 2 will be supplied by additional SD modules. Studies show that SD power for the growth eras will result in life cycle cost savings of $3 to $4 billion when compared to PV-supplied power. In the SD power modules for Space Station Freedom, an offset parabolic concentrator collects and focuses solar energy into a heat receiver. To allow full power operation over the entire orbit, the receiver includes integral thermal energy storage by means of the heat of fusion of a salt mixture. Thermal energy is removed from the receiver and converted to electrical energy by a power conversion unit (PCU) which includes a closed brayton cycle (CBC) heat engine and an alternator. The receiver/PCU/radiator combination will be completely assembled and charged with gas and cooling fluid on earth before launch to orbit. The concentrator subassemblies will be pre-aligned and stowed in the orbiter bay before launch. On orbit, the receiver/PCU/radiator assembly will be installed as a unit. The pre-aligned concentrator panels will then be latched together and the total concentrator attached to the receiver/PCU/radiator by the astronauts. After final electric connections are made and checkout is complete, the SD power module will be ready for operation.

Labus, Thomas L.↗

Q2/Q3 2019 Solar Industry Update

This technical presentation provides an update on the major trends that occurred in the solar industry in the first three quarters of 2019. Major topics of focus include costs and deployment, the global and U.S. supply and demand of PV, module and system price, investment trends and business models, and updates on U.S. government programs supporting the solar industry.

14 SOLAR ENERGY↗

Transfer Printed Microcells with Micro-Optic Concentrators for Low Cost, High Performance Photovoltaic Modules (Final Scientific and Technical Report)

This program of work established and validated a new form factor and fully scalable manufacturing processes for low cost, high performance photovoltaic modules. The programmatic highlights of the work include cost-effective assembly of modules fabricated from single crystalline semiconductor inks by high-throughput transfer printing of the micro-cells, advanced methods of systems level integration of sparse arrays, and design and fabrication of micro optical concentrator arrays that provide significant collection efficiencies of light and high performance of the system when integrated with the PV array module. The designs further provide efficient but fully passive heat management that simplifies fabrication while further enhancing operating capabilities of the modules. This collaborative program of research carried out under this award has exceeded all key guidelines laid out in the original proposal. It first has provided a new means to utilize high performance semiconductor materials in an exceptionally low cost and robust form factor. The technology so engendered by these key materials discoveries, new means of manufacturing, and advanced systems level designs are establishing new benchmarks for reductions in the installed cost/kWh relative to any commercial photovoltaic (PV) energy technology currently in use. The work in this program, having surpassed its key scientific milestones, has gone further and with our partners has now fully validated designs with scalable manufacturing methods for photovoltaic modules that use large-scale arrays of high efficiency solar microcells created from bulk wafers, integrating them in diverse spatial layouts on foreign substrates by transfer printing. Full research modules installed and operating at a utility site since 2010 have established the designs to be a viable PV technology.

36 MATERIALS SCIENCE↗

Terrestrial photovoltaic collector technology trends

Following the path of space PV collector development in its early stages, terrestrial PV technologies based upon single-crystal silicon have matured rapidly. Currently, terrestrial PV cells with efficiencies approaching space cell efficiencies are being fabricated into modules at a fraction of the space PV module cost. New materials, including CuInSe2 and amorphous silicon, are being developed for lowering the cost, and multijunction materials for achieving higher efficiency. Large grid-interactive, tracking flat-plate power systems and concentrator PV systems totaling about 10 MW, are already in operation. Collector technology development both flat-plate and concentrator, will continue under an extensive government and private industry partnership.

Shimada, K.↗

Institutional Transformation Version 2.5 Modeling and Planning.

Reducing the resource consumption and emissions of large institutions is an important step toward a sustainable future. Sandia National Laboratories' (SNL) Institutional Transformation (IX) project vision is to provide tools that enable planners to make well-informed decisions concerning sustainability, resource conservation, and emissions reduction across multiple sectors. The building sector has been the primary focus so far because it is the largest consumer of resources for SNL. The IX building module allows users to define the evolution of many buildings over time. The module has been created so that it can be generally applied to any set of DOE-2 ( http://doe2.com ) building models that have been altered to include parameters and expressions required by energy conservation measures (ECM). Once building models have been appropriately prepared, they are checked into a Microsoft Access (r) database. Each building can be represented by many models. This enables the capability to keep a continuous record of models in the past, which are replaced with different models as changes occur to the building. In addition to this, the building module has the capability to apply climate scenarios through applying different weather files to each simulation year. Once the database has been configured, a user interface in Microsoft Excel (r) is used to create scenarios with one or more ECMs. The capability to include central utility buildings (CUBs) that service more than one building with chilled water has been developed. A utility has been created that joins multiple building models into a single model. After using the utility, several manual steps are required to complete the process. Once this CUB model has been created, the individual contributions of each building are still tracked through meters. Currently, 120 building models from SNL's New Mexico and California campuses have been created. This includes all buildings at SNL greater than 10,000 sq. ft., representing 80% of the energy consumption at SNL. SNL has been able to leverage this model to estimate energy savings potential of many competing ECMs. The results helped high level decision makers to create energy reduction goals for SNL. These resources also have multiple applications for use of the models as individual buildings. In addition to the building module, a solar module built in Powersim Studio (r) allows planners to evaluate the potential photovoltaic (PV) energy generation potential for flat plate PV, concentrating solar PV, and concentration solar thermal technologies at multiple sites across SNL's New Mexico campus. Development of the IX modeling framework was a unique collaborative effort among planners and engineers in SNL's facilities division; scientists and computer modelers in SNL's research and development division; faculty from Arizona State University; and energy modelers from Bridger and Paxton Consulting Engineers Incorporated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of soiling in CPV systems

The effect of soiling in flat PV modules has been already studied, causing a reduction of the electrical output of 4% on average. For CPV's, as far as soiling produces light scattering at the optical collector surface, the scattered rays should be definitively lost because they cannot be focused onto the receivers again. While the theoretical study becomes difficult because soiling is variable at different sites, it becomes easier to begin the monitoring of the real field performance of concentrators and then raise the following question: how much does the soiling affect to PV concentrators in comparison with flat panels?' The answers allow to predict the PV concentrator electrical performance and to establish a pattern of cleaning frequency. Some experiments have been conducted at the IES-UPM and CSES-ANU sites, consisting in linear reflective concentration systems, a point focus refractive concentrator and a flat module. All the systems have been measured when soiled and then after cleaning, achieving different increases of I{sub SC}. In general, results show that CPV systems are more sensitive to soiling than flat panels, accumulating losses in I{sub SC} of about 14% on average in three different tests conducted at IES-UPM and CSES-ANU test sites in Madrid (Spain) and Canberra (Australia). Some concentrators can reach losses up to 26% when the system is soiled for 4 months of exposure. (author)

14 SOLAR ENERGY↗

Solar Industry Update (Q2/Q3 2020) [Slides]

Each quarter, the National Renewable Energy Laboratory (NREL) conducts the Quarterly Solar Industry Update, a presentation of technical trends within the solar industry, to the solar office staff. Each presentation focuses on global and U.S. supply and demand, module and system price, investment trends and business models, and updates on U.S. Government programs supporting the solar industry.

14 SOLAR ENERGY↗