Search NASA⌕ Search

SEARCH · Search NASA

Results for “confidence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Maximum-confidence discrimination among symmetric qudit states

We study the maximum-confidence (MC) measurement strategy for discriminating among nonorthogonal symmetric qudit states. Restricting to linearly dependent and equally likely pure states, we find the optimal positive operator valued measure (POVM) that maximizes our confidence in identifying each state in the set and minimizes the probability of obtaining inconclusive results. The physical realization of this POVM is completely determined and it is shown that after an inconclusive outcome, the input states may be mapped into a new set of equiprobable symmetric states, restricted, however, to a subspace of the original qudit Hilbert space. By applying the MC measurement again onto this new set, we can still gain some information about the input states, although with less confidence than before. This leads us to introduce the concept of sequential maximum-confidence (SMC) measurements, where the optimized MC strategy is iterated in as many stages as allowed by the input set, until no further information can be extracted from an inconclusive result. Within each stage of this measurement our confidence in identifying the input states is the highest possible, although it decreases from one stage to the next. In addition, the more stages we accomplish within the maximum allowed, the higher will be the probability of correct identification. We will discuss an explicit example of the optimal SMC measurement applied in the discrimination among four symmetric qutrit states and propose an optical network to implement it.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correction of confidence intervals in excess relative risk models using Monte Carlo dosimetry systems with shared errors

Introduction: Measurement errors are ubiquitous in epidemiological studies, especially for doses arising from environmental and occupational exposures, which are difficult to assess. Correction methods for independent measurement errors, have been comprehensively described elsewhere, including regression calibration, simulation extrapolation (SIMEX), etc. However, when exposure estimates are constructed using complicated physical and biological models, uncertainties in the dosimetry system can become very complex. In such systems, uncertainties in some parameters may affect a large group of study participants simultaneously, and hence are “shared” as opposed to independent dosimetric uncertainties. Representing the structure of the uncertainty in the dosimetry by providing multiple realizations of possible dose has been described for several studies. The goal of this paper is to implement, and explore the properties of, a generalized estimating equation-based approach to shared uncertainties based on principles described in an earlier paper. Methods: The effects of shared and unshared dosimetry error on parameter estimates and confidence intervals in a generalized excess relative risk model are examined. A post-hoc correction method is implemented that constructs corrected confidence intervals based on an underlying variance structure described in an earlier paper. In this correction method it is assumed that the estimated slope parameter in a linear excess relative risk model is distributed as a mixture of normal and lognormal components. A simulation study of the behavior of this correction was developed based on multiple realizations provided by the Monte Carlo dosimetry system used for the plutonium exposures in the Mayak Worker Cohort and a risk model with close similarity to that used in analyses of lung cancer data in that cohort. Results: In the simulation study we found that shared dose errors severely degraded the coverage probabilities of confidence limits for the slope parameter in the linear excess relative risk model relating uncertain exposure to lung cancer risk. Using our correction method to adjust the confidence intervals provided much improved coverage probabilities for this parameter. A smaller amount of degradation in confidence interval coverage for other parameters (e.g. those in the baseline and dose modification terms) was noted, and the proposed correction method also improved coverage for these parameters as well. Discussion: Compared to other recently described methods our proposed correction method relies on relatively familiar software to fit dose response models. The basic modeling philosophy described here first uses existing Poisson regression methods to estimate parameters in the excess relative risk model; in this first stage mean dose (computed from the multiple realizations) is used as the independent variable in the regression. Once the model is fit we then correct (widen) the standard errors for all parameters using the proposed correction method. The simulation studies indicate that the methods described here are an important contribution to the available tools for dealing with shared measurement errors in complex risk analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗

Confidence Calibration Metrics

This technical report serves to summarize a literature search conducted that covered confidence calibration. This report is meant to serve as a solid starting reference for individuals interested in learning more about the confidence calibration domain as well as for individuals more familiar with this work – as a summarizing document for calibration metrics is notably lacking in the literature. This report is not meant to serve as a comprehensive review of everything that has been done in this field – in fact, the reader is encouraged to look further into this domain. We describe confidence and calibration and discuss properties of good calibration metrics. We detail various calibration and calibration-tangential metrics, presenting equations, algorithms, parameters, and an analysis of strengths and weaknesses. We apply a subset of these metrics to eight proxy confidence assessment datasets. We examine the various metrics in the context of model confidence. Finally, we discuss promising future directions and outstanding questions.

99 GENERAL AND MISCELLANEOUS↗

An Algorithm for Efficient Maximum Likelihood Estimation and Confidence Interval Determination in Nonlinear Estimation Problems

An algorithm for maximum likelihood (ML) estimation is developed with an efficient method for approximating the sensitivities. The algorithm was developed for airplane parameter estimation problems but is well suited for most nonlinear, multivariable, dynamic systems. The ML algorithm relies on a new optimization method referred to as a modified Newton-Raphson with estimated sensitivities (MNRES). MNRES determines sensitivities by using slope information from local surface approximations of each output variable in parameter space. The fitted surface allows sensitivity information to be updated at each iteration with a significant reduction in computational effort. MNRES determines the sensitivities with less computational effort than using either a finite-difference method or integrating the analytically determined sensitivity equations. MNRES eliminates the need to derive sensitivity equations for each new model, thus eliminating algorithm reformulation with each new model and providing flexibility to use model equations in any format that is convenient. A random search technique for determining the confidence limits of ML parameter estimates is applied to nonlinear estimation problems for airplanes. The confidence intervals obtained by the search are compared with Cramer-Rao (CR) bounds at the same confidence level. It is observed that the degree of nonlinearity in the estimation problem is an important factor in the relationship between CR bounds and the error bounds determined by the search technique. The CR bounds were found to be close to the bounds determined by the search when the degree of nonlinearity was small. Beale's measure of nonlinearity is developed in this study for airplane identification problems; it is used to empirically correct confidence levels for the parameter confidence limits. The primary utility of the measure, however, was found to be in predicting the degree of agreement between Cramer-Rao bounds and search estimates.

Murphy, Patrick Charles↗

Random selection as a confidence building tool

Any verification measurement performed on potentially classified nuclear material must satisfy two seemingly contradictory constraints. First and foremost, no classified information can be released. At the same time, the monitoring party must have confidence in the veracity of the measurement. The first concern can be addressed by performing the measurements within the host facility using instruments under the host's control. Because the data output in this measurement scenario is also under host control, it is difficult for the monitoring party to have confidence in that data. One technique for addressing this difficulty is random selection. The concept of random selection can be thought of as four steps: (1) The host presents several 'identical' copies of a component or system to the monitor. (2) One (or more) of these copies is randomly chosen by the monitors for use in the measurement system. (3) Similarly, one or more is randomly chosen to be validated further at a later date in a monitor-controlled facility. (4) Because the two components or systems are identical, validation of the 'validation copy' is equivalent to validation of the measurement system. This procedure sounds straightforward, but effective application may be quite difficult. Although random selection is often viewed as a panacea for confidence building, the amount of confidence generated depends on the monitor's continuity of knowledge for both validation and measurement systems. In this presentation, we will discuss the random selection technique, as well as where and how this technique might be applied to generate maximum confidence. In addition, we will discuss the role of modular measurement-system design in facilitating random selection and describe a simple modular measurement system incorporating six small {sup 3}He neutron detectors and a single high-purity germanium gamma detector.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Achieving reasonable confidence in the validation of control room designs and modifications: A summary of the 2015 NEA experts' workshop - 124

Defining and achieving reasonable confidence in the validation of nuclear power plant control room designs is a complex challenge for many reasons; not the least of which is that validation is a test of strength rather than a test of truth. In 2015, the Nuclear Energy Agency, Committee for Safety of Nuclear Installations' Working Group on Human and Organizational Factors (WGHOF) hosted an experts' workshop to identify and critically examine potential means to address the challenge of achieving reasonable confidence in control room design validations. The experts' principal task was to answer four challenge questions. (1) What are the critical considerations in defining validation objectives and how do these impact achieving reasonable confidence? (2) What methods, approaches, resources, or rationales might be used for deriving performance requirements, selecting measures, and establishing acceptance criteria so as to support reasonable confidence? (3) What methods might be used to develop scenarios that maximize the amount and relevance of information in support of the validation conclusions and achieving reasonable confidence? (4) How should the validation results be aggregated and analyzed to determine the final validation conclusions? This paper provides an overview of the experts' responses to these challenges and briefly touches upon their implications for future directions. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Statistical Method for Assessing Peptide Identification Confidence in Accurate Mass and Time Tag Proteomics

High-throughput proteomics is rapidly evolving to require high mass measurement accuracy for a variety of different applications. Increased mass measurement accuracy in bottom-up proteomics specifically allows for an improved ability to distinguish and characterize detected MS features, which may in turn be identified by, e.g., matching to entries in a database for both precursor and fragmentation mass identification methods. Many tools exist with which to score the identification of peptides from LC-MS/MS measurements or to assess matches to an accurate mass and time (AMT) tag database, but these two calculations remain distinctly unrelated. Here we present a statistical method, Statistical Tools for AMT tag Confidence (STAC), which extends our previous work incorporating prior probabilities of correct sequence identification from LC-MS/MS, as well as the quality with which LC-MS features match AMT tags, to evaluate peptide identification confidence. Compared to existing tools, we are able to obtain significantly more high-confidence peptide identifications at a given false discovery rate and additionally assign confidence estimates to individual peptide identifications. Freely available software implementations of STAC are available in both command line and as a Windows graphical application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of a Metal Artifact Reduction Algorithm for C-Arm Cone-Beam CT: Impact on Image Quality and Diagnostic Confidence for Bronchial Artery Embolization

Objective: The objective of this study was to evaluate the potential benefit of a dedicated cone-beam-CT streak metal artifact removal technique (SMART) in terms of both image quality and diagnostic confidence in patients undergoing bronchial artery embolization. Methods: A total of 17 patients were included in this retrospective study. The SMART algorithm was applied to images containing streak artifacts generated by a radiopaque intra-arterial catheter tip. Quantitative evaluation of artifact severity was performed via measurement of the Hounsfield units along a closed loop surrounding the catheter tip and was conducted in the frequency domain following the application of the discrete Fourier transform to the measured data. A high proportion of power in the low frequencies of the resulting spectrum indicated a high level of streak artifacts. Qualitative evaluation of diagnostic confidence was performed using a 4-point Likert scale. Results: Both quantitative and qualitative evaluation demonstrated a significant reduction in artifact severity using the SMART algorithm. Quantitative evaluation demonstrated a mean artifact reduction of 22.5% using SMART compared to non-SMART images (p < 0.001). Qualitative evaluation demonstrated the greatest artifact reduction at the inner and outer aortic curvature, as well as immediately surrounding the tip of the catheter. In 6 of 17 cases, the use of the SMART algorithm yielded additional clinical information, increasing mean diagnostic confidence from 3.17 to 3.78 (p < 0.001). Conclusion: The SMART algorithm allows for efficient reduction of metal artifacts introduced by radiopaque catheter tips during cone-beam CT. Using this algorithm, diagnostic images of the aortic arch were significantly improved both quantitatively and qualitatively, yielding clinically relevant levels of enhanced diagnostic confidence. These results demonstrate that the SMART algorithm improves diagnostic and clinical characterization of the course of bronchial arteries on CBCT images, potentially improving the accuracy and clinical efficacy of bronchial artery embolization. Level of Evidence: 3.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proposed Confidence Scale and ID Score in the Identification of Known-Unknown Compounds Using High Resolution MS Data

High-resolution (HR) MS instruments recording HR-full scan allow analysts to go further beyond pre-acquisition choices. Untargeted acquisition can reveal unexpected compounds or concentrations and can be performed for preliminary diagnosis attempt. Then, revealed compounds will have to be identified for interpretations. Whereas the need of reference standards is mandatory to confirm identification, the diverse information collected from HRMS allows identifying unknown compounds with relatively high degree of confidence without reference standards injected in the same analytical sequence. However, there is a necessity to evaluate the degree of confidence in putative identifications, possibly before further targeted analyses. This is why a confidence scale and a score in the identification of (non-peptidic) known-unknown, defined as compounds with entries in database, is proposed for (LC-) HRMS data. The scale is based on two representative documents edited by the European Commission (2007/657/EC) and the Metabolomics Standard Initiative (MSI), in an attempt to build a bridge between the communities of metabolomics and screening labs. With this confidence scale, an identification (ID) score is determined as [a number, a letter, and a number] (e.g., 2D3), from the following three criteria: I, a General Identification Category (1, confirmed, 2, putatively identified, 3, annotated compounds/classes, and 4, unknown); II, a Chromatography Class based on the relative retention time (from the narrowest tolerance, A, to no chromatographic references, D); and III, an Identification Point Level (1, very high, 2, high, and 3, normal level) based on the number of identification points collected. Three putative identification examples of known-unknown will be presented. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved LC-MS/MS Spectral Counting Statistics by Recovering Low Scoring Spectra Matched to Confidently Identified Peptide Sequences

Spectral counting has become a popular semi-quantitative method for LC-MS/MS based proteome quantification; however, this methodology is often not reliable when proteins are identified by a small number of spectra. Here we present a simple strategy to improve spectral counting based quantification for low abundance proteins by recovering low quality or low scoring spectra for confidently identified peptides. In this approach, stringent data filtering criteria were initially applied to achieve confident peptide identifications with low false discovery rate (e.g., <1%) after LC-MS/MS analysis and database search by SEQUEST. Then, all low scoring MS/MS spectra that match to this set of confidently identified peptides were recovered, leading to more than 20% increase of total identified spectra. The validity of these recovered spectra was assessed by the parent ion mass measurement error distribution, retention time distribution, and by comparing the individual low score and high score spectra that correspond to the same peptides. The results support that the recovered low scoring spectra have similar confidence levels in peptide identifications as the spectra passing the initial stringent filter. The application of this strategy of recovering low scoring spectra significantly improved the spectral count quantification statistics for low abundance proteins, as illustrated in the identification of mouse brain region specific proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Confidence Level and Sensitivity Limits in High Contrast Imaging

In long adaptive optics corrected exposures, exoplanet detections are currently limited by speckle noise originating from the telescope and instrument optics, and it is expected that such noise will also limit future high-contrast imaging instruments for both ground and space-based telescopes. Previous theoretical analysis have shown that the time intensity variations of a single speckle follows a modified Rician. It is first demonstrated here that for a circular pupil this temporal intensity distribution also represents the speckle spatial intensity distribution at a fix separation from the point spread function center; this fact is demonstrated using numerical simulations for coronagraphic and non-coronagraphic data. The real statistical distribution of the noise needs to be taken into account explicitly when selecting a detection threshold appropriate for some desired confidence level. In this paper, a technique is described to obtain the pixel intensity distribution of an image and its corresponding confidence level as a function of the detection threshold. Using numerical simulations, it is shown that in the presence of speckles noise, a detection threshold up to three times higher is required to obtain a confidence level equivalent to that at 5{sigma} for Gaussian noise. The technique is then tested using TRIDENT CFHT and angular differential imaging NIRI Gemini adaptive optics data. It is found that the angular differential imaging technique produces quasi-Gaussian residuals, a remarkable result compared to classical adaptive optic imaging. A power-law is finally derived to predict the 1-3 x 10{sup -7} confidence level detection threshold when averaging a partially correlated non-Gaussian noise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistical variability and confidence intervals for planar dose QA pass rates

Purpose: The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimeters, the grid of analyzed points corresponds to an array with a low areal density of point detectors. In these cases, the pass rates for any given comparison criteria are not absolute but exhibit statistical variability that is a function, in part, on the detector sampling geometry. In this work, the authors analyze the statistics of various methods commonly used to calculate pass rates and propose methods for establishing confidence intervals for pass rates obtained with low-density arrays. Methods: Dose planes were acquired for 25 prostate and 79 head and neck intensity-modulated fields via diode array and electronic portal imaging device (EPID), and matching calculated dose planes were created via a commercial treatment planning system. Pass rates for each dose plane pair (both centered to the beam central axis) were calculated with several common comparison methods: %Diff/DTA composite analysis and gamma evaluation, using absolute dose comparison with both local and global normalization. Specialized software was designed to selectively sample the measured EPID response (very high data density) down to discrete points to simulate low-density measurements. The software was used to realign the simulated detector grid at many simulated positions with respect to the beam central axis, thereby altering the low-density sampled grid. Simulations were repeated with 100 positional iterations using a 1 detector/cm{sup 2} uniform grid, a 2 detector/cm{sup 2} uniform grid, and similar random detector grids. For each simulation, %/DTA composite pass rates were calculated with various %Diff/DTA criteria and for both local and global %Diff normalization techniques. Results: For the prostate and head/neck cases studied, the pass rates obtained with gamma analysis of high density dose planes were 2%-5% higher than respective %/DTA composite analysis on average (ranging as high as 11%), depending on tolerances and normalization. Meanwhile, the pass rates obtained via local normalization were 2%-12% lower than with global maximum normalization on average (ranging as high as 27%), depending on tolerances and calculation method. Repositioning of simulated low-density sampled grids leads to a distribution of possible pass rates for each measured/calculated dose plane pair. These distributions can be predicted using a binomial distribution in order to establish confidence intervals that depend largely on the sampling density and the observed pass rate (i.e., the degree of difference between measured and calculated dose). These results can be extended to apply to 3D arrays of detectors, as well. Conclusions: Dose plane QA analysis can be greatly affected by choice of calculation metric and user-defined parameters, and so all pass rates should be reported with a complete description of calculation method. Pass rates for low-density arrays are subject to statistical uncertainty (vs. the high-density pass rate), but these sampling errors can be modeled using statistical confidence intervals derived from the sampled pass rate and detector density. Thus, pass rates for low-density array measurements should be accompanied by a confidence interval indicating the uncertainty of each pass rate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Confidence intervals with a priori parameter bounds

We review the methods of constructing confidence intervals that account for a priori information about one-sided constraints on the parameter being estimated. We show that the so-called method of sensitivity limit yields a correct solution of the problem. Derived are the solutions for the cases of a continuous distribution with non-negative estimated parameter and a discrete distribution, specifically a Poisson process with background. For both cases, the best upper limit is constructed that accounts for the a priori information. A table is provided with the confidence intervals for the parameter of Poisson distribution that correctly accounts for the information on the known value of the background along with the software for calculating the confidence intervals for any confidence levels and magnitudes of the background (the software is freely available for download via Internet).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Do LIGO/Virgo Black Hole Mergers Produce AGN Flares? The Case of GW190521 and Prospects for Reaching a Confident Association

The recent report of an association of the gravitational-wave (GW) binary black hole (BBH) merger GW190521 with a flare in the active galactic nuclei (AGNs) J124942.3 + 344929 has generated tremendous excitement. However, GW190521 has one of the largest localization volumes among all of the GW events detected so far. The 90% localization volume likely contains 7400 unobscured AGNs brighter than g ≤ 20.5 AB mag, and it results in a ≳70% probability of chance coincidence for an AGN flare consistent with the GW event. We present a Bayesian formalism to estimate the confidence of an AGN association by analyzing a population of BBH events with dedicated follow-up observations. Depending on the fraction of BBHs arising from AGNs, counterpart searches of $\mathcal{O}(1) - \mathcal{O}(100)$ GW events are needed to establish a confident association, and more than an order of magnitude more for searches without follow-up (i.e., using only the locations of AGN and GW events). Follow-up campaigns of the top ~5% (based on volume localization and binary mass) of BBH events with total rest-frame mass ≥50 M ⊙ are expected to establish a confident association during the next LIGO/Virgo/KAGRA observing run (O4), as long as the true value of the fraction of BBHs giving rise to AGN flares is >0.1. Our formalism allows us to jointly infer cosmological parameters from a sample of BBH events that include chance coincidence flares. Until the confidence of AGN associations is established, the probability of chance coincidence must be taken into account to avoid biasing astrophysical and cosmological constraints.

79 ASTRONOMY AND ASTROPHYSICS↗

A methodology for airplane parameter estimation and confidence interval determination in nonlinear estimation problems

An algorithm for maximum likelihood (ML) estimation is developed with an efficient method for approximating the sensitivities. The ML algorithm relies on a new optimization method referred to as a modified Newton-Raphson with estimated sensitivities (MNRES). MNRES determines sensitivities by using slope information from local surface approximations of each output variable in parameter space. With the fitted surface, sensitivity information can be updated at each iteration with less computational effort than that required by either a finite-difference method or integration of the analytically determined sensitivity equations. MNRES eliminates the need to derive sensitivity equations for each new model, and thus provides flexibility to use model equations in any convenient format. A random search technique for determining the confidence limits of ML parameter estimates is applied to nonlinear estimation problems for airplanes. The confidence intervals obtained by the search are compared with Cramer-Rao (CR) bounds at the same confidence level. The degree of nonlinearity in the estimation problem is an important factor in the relationship between CR bounds and the error bounds determined by the search technique. Beale's measure of nonlinearity is developed in this study for airplane identification problems; it is used to empirically correct confidence levels and to predict the degree of agreement between CR bounds and search estimates.

Murphy, P. C.↗

On the appropriateness of applying chi-square distribution based confidence intervals to spectral estimates of helicopter flyover data

The validity of applying chi-square based confidence intervals to far-field acoustic flyover spectral estimates was investigated. Simulated data, using a Kendall series and experimental acoustic data from the NASA/McDonnell Douglas 500E acoustics test, were analyzed. Statistical significance tests to determine the equality of distributions of the simulated and experimental data relative to theoretical chi-square distributions were performed. Bias and uncertainty errors associated with the spectral estimates were easily identified from the data sets. A model relating the uncertainty and bias errors to the estimates resulted, which aided in determining the appropriateness of the chi-square distribution based confidence intervals. Such confidence intervals were appropriate for nontonally associated frequencies of the experimental data but were inappropriate for tonally associated estimate distributions. The appropriateness at the tonally associated frequencies was indicated by the presence of bias error and noncomformity of the distributions to the theoretical chi-square distribution. A technique for determining appropriate confidence intervals at the tonally associated frequencies was suggested.

Rutledge, Charles K.↗

Reliability and Confidence Interval Analysis of a CMC Turbine Stator Vane

High temperature ceramic matrix composites (CMC) are being explored as viable candidate materials for hot section gas turbine components. These advanced composites can potentially lead to reduced weight, enable higher operating temperatures requiring less cooling and thus leading to increased engine efficiencies. However, these materials are brittle and show degradation with time at high operating temperatures due to creep as well as cyclic mechanical and thermal loads. In addition, these materials are heterogeneous in their make-up and various factors affect their properties in a specific design environment. Most of these advanced composites involve two- and three-dimensional fiber architectures and require a complex multi-step high temperature processing. Since there are uncertainties associated with each of these in addition to the variability in the constituent material properties, the observed behavior of composite materials exhibits scatter. Traditional material failure analyses employing a deterministic approach, where failure is assumed to occur when some allowable stress level or equivalent stress is exceeded, are not adequate for brittle material component design. Such phenomenological failure theories are reasonably successful when applied to ductile materials such as metals. Analysis of failure in structural components is governed by the observed scatter in strength, stiffness and loading conditions. In such situations, statistical design approaches must be used. Accounting for these phenomena requires a change in philosophy on the design engineer s part that leads to a reduced focus on the use of safety factors in favor of reliability analyses. The reliability approach demands that the design engineer must tolerate a finite risk of unacceptable performance. This risk of unacceptable performance is identified as a component's probability of failure (or alternatively, component reliability). The primary concern of the engineer is minimizing this risk in an economical manner. The methods to accurately determine the service life of an engine component with associated variability have become increasingly difficult. This results, in part, from the complex missions which are now routinely considered during the design process. These missions include large variations of multi-axial stresses and temperatures experienced by critical engine parts. There is a need for a convenient design tool that can accommodate various loading conditions induced by engine operating environments, and material data with their associated uncertainties to estimate the minimum predicted life of a structural component. A probabilistic composite micromechanics technique in combination with woven composite micromechanics, structural analysis and Fast Probability Integration (FPI) techniques has been used to evaluate the maximum stress and its probabilistic distribution in a CMC turbine stator vane. Furthermore, input variables causing scatter are identified and ranked based upon their sensitivity magnitude. Since the measured data for the ceramic matrix composite properties is very limited, obtaining a probabilistic distribution with their corresponding parameters is difficult. In case of limited data, confidence bounds are essential to quantify the uncertainty associated with the distribution. Usually 90 and 95% confidence intervals are computed for material properties. Failure properties are then computed with the confidence bounds. Best estimates and the confidence bounds on the best estimate of the cumulative probability function for R-S (strength - stress) are plotted. The methodologies and the results from these analyses will be discussed in the presentation.

Murthy, Pappu L. N.↗

Functional Mobility Performance and Balance Confidence in Older Adults after Sensorimotor Adaptation Training

Research indicates a main contributor of injury in older adults is from falling. The decline in sensory systems limits information needed to successfully maneuver through the environment. The objective of this study was to determine if prolonged exposure to the realignment of perceptual-motor systems increases adaptability of balance, and if balance confidence improves after training. A total of 16 older adults between ages 65-85 were randomized to a control group (walking on a treadmill while viewing a static visual scene) and an experimental group (walking on a treadmill while viewing a rotating visual scene). Prior to visual exposure, participants completed six trials of walking through a soft foamed obstacle course. Participants came in twice a week for 4 weeks to complete training of walking on a treadmill and viewing the visual scene for 20 minutes each session. Participants completed the obstacle course after training and four weeks later. Average time, penalty, and Activity Balance Confidence Scale scores were computed for both groups across testing times. The older adults who trained, significantly improved their time through the obstacle course F (2, 28) = 9.41, p < 0.05, as well as reduced their penalty scores F (2, 28) = 21.03, p < 0.05, compared to those who did not train. There was no difference in balance confidence scores between groups across testing times F (2, 28) = 0.503, p > 0.05. Although the training group improved mobility through the obstacle course, there were no differences between the groups in balance confidence.

Buccello-Stout, Regina R.↗