Integrated cabin heating and powertrain thermal energy management for a connected hybrid electric vehicle
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Ni-modified beta zeolite (Ni/BEA) catalysts activate carbon-hydrogen bonds in light alkanes, as demonstrated through isobutane reaction testing. Controlled synthesis of Ni/BEA allows for efficient introduction of ion-exchanged Ni sites at varying Ni loadings (0.43% - 1.8%). These catalysts exhibit site time yields (STY) for H2 production that increase with increasing Ni loading. A detailed analysis of secondary reactions and carbon deposition based on the relative molar flowrates of product C and H indicates that the observed increase in H2 STY with increasing Ni loading is likely attributed to both increasing alkane activation activity and increasing formation of hydrogen-deficient aromatic products retained within the catalyst pores. In situ diffuse-reflectance UV-visible-NIR absorbance and X-ray absorption spectroscopies indicate isolated, 4-coordinate Ni(2+) species for all loadings. Quantum mechanics/molecular mechanics modeling identifies two distinct Ni(2+) sites consistent with the structural characterization, but with differing relative stabilities due to their coordination environment. Computed reaction energetics for isobutane dehydrogenation demonstrate that the more stable Ni(2+) species at a six-membered 4Si-2Al ring, Ni-6MR, is less active for isobutane dehydrogenation than the less stable Ni(2+) at the five-membered 3Si-2Al ring, Ni-5MR. The differing local structure of the isolated cationic Ni sites in Ni/BEA offers a possible rationalization for the increased H2 STY observed at greater Ni loadings.
Not Available
Magnetic skyrmions, which are topologically distinct magnetic spin textures, are gaining increased attention for their unique physical properties and potential applications in spintronic devices. Here we present a design strategy for skyrmion host candidates based on combinations of magnetic spin, asymmetric building units having stereoactive lone-pair electrons, and polar lattice symmetry. To demonstrate the viability of the proposed rational design principles, we successfully synthesized a Fe(IO 3 ) 3 polycrystalline sample and single crystals by using a new simplified low-temperature pathway, which is experimentally feasible for extending materials growth of transition metal iodates. Single crystal X-ray and powder synchrotron X-ray diffraction measurements demonstrated that Fe(IO 3 ) 3 crystallizes in the polar chiral hexagonal lattice with space group P63. The combined structural features of the macroscopic electric polarization along the c-axis stemming from the coalignment of the stereoactive lone-pairs of the IO 3 – trigonal pyramid and the magnetic Fe 3+ cation residing on the 3-fold rotation axis were selected to promote asymmetric exchange coupling. We find evidence of a predicted skyrmion phase at 14 K ≤ T ≤ 16 K and 2.5 T ≤ μ 0 H ≤ 3.2 T driven by a Dzyaloshinskii–Moriya (DM) interaction, a conclusion supported by the appreciable DM exchange and the zero-field spiral antiferromagnetic ground state of Fe(IO 3 ) 3 deduced from neutron diffraction experiments. The associated magnetic modulation wavelength of the putative skyrmions is expected to be short ~18 nm, comparable to the period of the DM-driven incommensurate order. This work links stereoactive lone-pair electron effects to enhanced DM interaction, demonstrating a new approach for chemical guidelines in the search for skyrmionic states of matter.
Explore the source record for details and available documents.
In this paper a new concept of multiport modular medium-voltage power electronics hub (M3PE-HUB) is introduced for future power grid. The goal for this project is to design, develop, and demonstrate foundational technologies and capabilities for multiport power electronics energy hubs that can serve as intelligent devices to coordinate and control several different sources and loads. In this paper, the architecture of the controller, the central controls, and its verification is presented.
The dynamics of powertrain control systems are complicated and involve both nonlinear plant model and control functionalities, albeit they are well defined and formulated using first principle approaches. This constitutes difficulties in exploring implementable optimal tuning rules for some selected control parameters using vehicle-to-vehicle (V2V) communications. This paper presents a way to use neural networks (NN) to represent the problem of parameter tuning for optimizing fuel consumption. For this purpose, physical modelling and validation have been firstly performed for the closed loop powertrain system of the concerned vehicle for some given driving cycles. This is then followed by the sensitivity analysis that selects most influential control parameters to optimize. Using the data generated from the obtained physical models, an equivalent NN formulation has finally been obtained that gives simple yet unified objectives and constraints ready to be used to solve the optimization problem that produces optimal tuning rules for the selected control parameters to minimize fuel consumption.
As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 (or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience.
As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 ( or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience. For decarbonization, the new administration has set a target to reduce greenhouse gas emissions by 50– 52% by 2030 and targeting a carbon-neutral economy by 2050. For electrification, the goal is to achieve 100% clean electricity by 2035. Such decarbonization and electrification in the building sector require that energy consumption in buildings be reduced significantly. Therefore, the building sector must continuously adopt new technologies to achieve its energy and carbon emission goals. One of the most fundamental technologies is the Internet of Things (IoT). IoT has proven to be an effective solution for the building domain, including building information/energy modeling, smart buildings, etc. Although much progress has been made in the development of IoT-based building energy systems, there is still a lack of reliable, scalable, and affordable IoT-based automated fault and degradation diagnostics (AFDDs) solutions. Such solutions would enable deployment of advanced algorithms into real systems to archive the projected energy benefits. This study reviews existing IoT solutions developed for building energy– related application and developed a simple but effective AFDD IoT deployment solution, including developing a suitable IoT architecture and conducting easy and scalable deployment by leveraging a common cloud-based IoT service.
Abstract Aim Plant trait databases often contain traits that are correlated, but for whom direct (undirected statistical dependency) and indirect (mediated by other traits) connections may be confounded. The confounding of correlation and connection hinders our understanding of plant strategies, and how these vary among growth forms and climate zones. We identified the direct and indirect connections across plant traits relevant to competition, resource acquisition and reproductive strategies using a global database and explored whether connections within and between traits from different tissue types vary across climates and growth forms. Location Global. Major taxa studied Plants. Time period Present. Methods We used probabilistic graphical models and a database of 10 plant traits (leaf area, specific leaf area, mass‐ and area‐based leaf nitrogen and phosphorous content, leaf life span, plant height, stem specific density and seed mass) with 16,281 records to describe direct and indirect connections across woody and non‐woody plants across tropical, temperate, arid, cold and polar regions. Results Trait networks based on direct connections are sparser than those based on correlations. Land plants had high connectivity across traits within and between tissue types; leaf life span and stem specific density shared direct connections with all other traits. For both growth forms, two groups of traits form modules of more highly connected traits; one related to resource acquisition, the other to plant architecture and reproduction. Woody species had higher trait network modularity in polar compared to temperate and tropical climates, while non‐woody species did not show significant differences in modularity across climate regions. Main conclusions Plant traits are highly connected both within and across tissue types, yet traits segregate into persistent modules of traits. Variation in the modularity of trait networks suggests that trait connectivity is shaped by prevailing environmental conditions and demonstrates that plants of different growth forms use alternative strategies to cope with local conditions.
The share of renewable and distributed energy resources (DERs), like wind turbines, solar photovoltaics and grid-connected batteries, interconnected to the electric grid is rapidly increasing due to reduced costs, rising efficiency, and regulatory requirements aimed at incentivizing a lower-carbon electricity system. These distributed energy resources differ from traditional generation in many ways including the use of many smaller devices connected primarily (but not exclusively) to the distribution network, rather than few larger devices connected to the transmission network. DERs being installed today often include modern communication hardware like cellular modems and WiFi connectivity and, in addition, the inverters used to connect these resources to the grid are gaining increasingly complex capabilities, like providing voltage and frequency support or supporting microgrids. To perform these new functions safely, communications to the device and more complex controls are required. The distributed nature of DER devices combined with their network connectivity and complex controls interfaces present a larger potential attack surface for adversaries looking to create instability in power systems. To address this area of concern, the steps of a cyberattack on DERs have been studied, including the security of industrial protocols, the misuse of the DER interface, and the physical impacts. These different steps have not previously been tied together in practice and not specifically studied for grid-connected storage devices. In this work, we focus on grid-connected batteries. We explore the potential impacts of a cyberattack on a battery to power system stability, to the battery hardware, and on economics for various stakeholders. We then use real hardware to demonstrate end-to-end attack paths exist when security features are disabled or misconfigured. Our experimental focus is on control interface security and protocol security, with the initial assumption that an adversary has gained access to the network to which the device is connected. We provide real examples of the effectiveness of certain defenses. This work can be used to help utilities and other grid-connected battery owners and operators evaluate the severity of different threats and the effectiveness of defense strategies so they can effectively deploy and protect grid-connected storage devices.