Search NASA⌕ Search

SEARCH · Search NASA

Results for “conservative loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Predicting nepheline precipitation in waste glasses using ternary submixture model and machine learning

Nepheline precipitation in nuclear waste glasses during vitrification can be detrimental due to its negative effect on chemical durability. Developing models to accurately predict nepheline precipitation from compositions is important to increase waste loading since existing models can be overly conservative. In this study, an expanded dataset containing 955 glasses was compiled from literature data, where 355 glasses are for high-level waste (HLW). Previously developed submixture models were refitted using the new dataset, where a misclassification rate of 7.8% was achieved. Nine machine learning (ML) algorithms (e.g., k-nearest neighbor, Gaussian process regression, artificial neural network, support vector machine, decision tree, etc.) were applied to evaluate their ability of predicting nepheline precipitation from compositions. Model accuracy, precision, recall/sensitivity, and F1 score were systemically compared between different ML algorithms and modeling protocols. Good model prediction with an accuracy ~0.9 (misclassification rate of ~10%) was observed with different algorithms under certain protocol. This study evaluated various ML models to predict nepheline precipitations in waste glasses, highlighting the importance of data preparation, modeling protocol, and their effect on model stability and reproducibility. The results provide insights into applying ML to predict glass properties and suggest areas for future research on modeling nepheline precipitations.

Lu, Xiaonan↗

Phased: Phase-Aware Submodularity-Based Energy Disaggregation

Energy disaggregation is the task of discerning the energy consumption of individual appliances from aggregated measurements, which holds promise for understanding and reducing energy usage. In this paper, we propose PHASED, an optimization approach for energy disaggregation that has two key features: PHASED (i) exploits the structure of power distribution systems to make use of readily available measurements that are neglected by existing methods, and (ii) poses the problem as a minimization of a difference of sub-modular functions. We leverage this form by applying a discrete optimization variant of the majorization-minimization algorithm to iteratively minimize a sequence of global upper bounds of the cost function to obtain high-quality approximate solutions. PHASED improves the disaggregation accuracy of state-of-the-art models by up to 61% and achieves better prediction on heavy load appliances.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Demographic Information Incorporated Household Energy Consumption Analysis

The high energy consumption from residential buildings provides them large potential to participate in demand response programs. To design appropriate demand response programs for residential buildings, it is important for electric utilities to know the energy consumption characteristics for different types of households so that utilities can send requests to the groups with a higher possibility to successfully respond. In this paper, we develop a load model to generate synthetic load profiles for different types of households incorporating demographical information including Current Population Survey data set and American Time Use Survey data set. The details of each data set and the details of the load models are presented. The synthetic household load profiles are generated by the load model and clustered into different groups based on state, age, number of occupants, income level, and city of the household. The average energy consumption characteristics for different groups of households are analyzed and compared, which will help electric utilities issue demand response signals to appropriate households.

building loads↗

Thermomechanical analysis and modeling of a high-temperature light trapping planar cavity solar receiver

The development of durable particle-based high-temperature solar receivers is critical for advancing concentrating solar-thermal (CST) technologies to enable high-efficiency power generation and industrial process heat. Here, this study presents a computational framework to evaluate the thermomechanical performance of a proposed enclosed light-trapping planar cavity receiver designed for particle-based thermal energy systems. The receiver incorporates absorptive cavities and fluidized particle-bed channels to enhance heat capture and reduce thermal losses. Finite element analysis (FEA) is employed to assess stress, strain, and creep-fatigue behavior under concentrated solar flux using realistic thermal boundary conditions derived from coupled system models and experimental assembly parameters. The analysis investigates the influence of particle-to-wall heat transfer coefficients (HTC) ranging from 800 to 1800 W/m 2 .K on the thermomechanical response of six candidate high-temperature alloys: Alloy 740H, Alloy 282, Alloy 617, 316H, Alloy 230, and 800H. Results show that increasing HTC reduces thermal gradients, leading to lower stresses and strains and extended minimum predicted creep life. While all materials satisfy fatigue life requirements under the investigated conditions, significant differences in creep resistance are observed. Alloy 740H consistently exhibits the longest minimum predicted creep life and the most favorable durability margins, followed by Alloy 282, with the remaining materials showing reduced creep resistance under identical loading. The reported creep lives are conservative lower-bound estimates intended for comparative material evaluation. This framework highlights the critical roles of material selection and geometry optimization in improving mechanical durability and reliability of solar-thermal receivers, forming a foundation for future experimental validation and design optimization.

14 SOLAR ENERGY↗

The Empirical Effect of Fleet Optimization on Synchronization and Rebound Effects in Heat Pump Water Heaters

Demand response is a growing concept in light of the internet of things and an increasing need for grid flexibility. Water heaters are one of the preferred devices for providing demand response for grid services and peak management due to their capability to store energy. The efficient use of water heaters for demand response requires consideration of the associated load effects such as synchronization of device schedules and rebound effect. These effects present a significant challenge. Despite the importance of the mentioned effects for water heater queuing and scheduling, there has been no effort to quantify and empirically validate their impact. This study attempts to address this gap by offering two methods - Ward clustering and Euclidean K-means - to evaluate the extent of synchronization in a fleet of 42 water heaters in Atlanta, GA. Using the aforementioned methods on the measured data, we find evidence of convergence of water heater loads as a result of optimization compared to an idle period and analyzed their impact.

demand response↗

Peak Reduction Using Mode Adjustment of Heat Pump Water Heaters in a Residential Neighborhood

Building electrification is putting pressure on distribution grid worldwide. Peak reduction is an important concern that can help reduce the growing stress and allow to defer investments in new capacity. Water heaters represent a convenient way of reducing peak because they are less dependent on weather, and their storage volume allows for asynchronous water heating and hot water use. Previous empirical studies investigated the ability of water heaters to reduce peak through the adjustment of the temperature setpoint. However, not all equipment vendors offer this option. This study aims at understanding the feasibility of peak reduction with an alternative configuration available in the market - by adjusting the device mode rather than temperature setpoint. The peak reduction methodology is tested in an occupied 46-townhome neighborhood located in Atlanta, GA. We find that peak shifting is possible with the adjustable mode approach, with the change in the peak load by 30-60%.

demand response↗

Putting Our Industry's Data to Work: A Case Study of Large-Scale Data Aggregation: Preprint

With increasing deployment of Advanced Metering Infrastructure (AMI), Building Automation System (BAS) controls, Internet of Things (IoT) network devices, and data-driven evaluation, measurement, and verification studies, the building sector is currently generating a staggering amount of energy-related data. In the right hands, these data sets can contribute to increased comfort and energy savings for building occupants and a more reliable electrical grid; however, due to a combination of factors, including significant privacy concerns, much of the data that are presently generated and stored are not used outside of basic operational applications. In the past year, our team has dedicated over 2,000 person-hours to accessing building energy data for a project funded by the U.S. Department of Energy (DOE) Building Technologies Office. We sought whole-building or end-use (e.g., lighting) timeseries data at the individual-building or equipment level where possible or aggregated information, such as timeseries averages and quartiles by building type (e.g., office, retail, hospital), where sharing individual building information was not an option. We are additionally working with IoT and BAS data sets to derive information important to the project. We have assembled an extensive data set that will enable the development of publicly available end-use load profiles to benefit the U.S. building and electricity industries. Here we present an overview of the data set that we have assembled to date, the motivators and approaches that got us here, and the lessons we learned through our efforts. We also discuss work underway that presents additional options for future data access.

building energy data↗

End-Use Load Profiles for the U.S. Building Stock: Technical Advisory Group Meeting #11

A technical advisory group guided the End-Use Load Profiles dataset development to ensure that the direction and outcomes of the work were aligned with market needs. The technical advisory group included roughly 100 representatives from organizations that were likely to use the resulting load profiles in their work, including utility companies, utility program implementers, grid operators, consultancies, research centers, state regulatory agencies, and regional energy efficiency organizations. This is the presentation from TAG Meeting #11.

buildings↗

Study Highlights: Characterizing Plug Load Energy Use and Savings Potential in Army Buildings

A recent study of plug load devices in Army buildings has identified opportunities to save over 83 million kWh of electricity valued at over $5 million per year. These savings may be conservative and were identified by inventorying and monitoring plug load and miscellaneous electric load (MEL) equipment within representative Army buildings. The objective was to better understand the energy consumed by these devices and identify approaches for reducing it while enhancing resilience. This summary highlights the findings, lessons learned, and recommendations identified by the study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Best Practices for Smart Grid-Interactive Efficient Building Ready Performance Contracts

Grid-interactive efficient building (GEB) measures reduce costs and optimize energy use for additional grid services by coordinating building energy loads and providing continuous demand management. Incorporating GEB energy conservation measures (ECMs) in performance contracts is reliant upon multiple factors. These factors include site selection with utility tariffs and incentives favorable to GEB, the identification of GEB as a priority in the initial stages of the contracting process, integration of GEB within comprehensive performance contracts with multiple other ECMs, and careful consideration of GEB measurement and verification (M&V) for energy savings performance contracts (ESPCs) and performance assurance for utility energy service contracts (UESCs).

building energy loads↗

Immunogenicity and protective efficacy of a rhesus adenoviral vaccine targeting conserved COVID-19 replication transcription complex

The COVID-19 pandemic marks the third coronavirus pandemic this century (SARS-CoV-1, MERS, SARS-CoV-2), emphasizing the need to identify and evaluate conserved immunogens for a pan-sarbecovirus vaccine. Here we investigate the potential utility of a T-cell vaccine strategy targeting conserved regions of the sarbecovirus proteome. We identified the most conserved regions of the sarbecovirus proteome as portions of the RNA-dependent RNA polymerase (RdRp) and Helicase proteins, both of which are part of the coronavirus replication transcription complex (RTC). Fitness constraints suggest that as SARS-CoV-2 continues to evolve these regions may better preserve cross-reactive potential of T-cell responses than Spike, Nucleocapsid, or Membrane proteins. We sought to determine if vaccine-elicited T-cell responses to the highly conserved regions of the RTC would reduce viral loads following challenge with SARS-CoV-2 in mice using a rhesus adenovirus serotype 52 (RhAd52) vector. The RhAd52.CoV.Consv vaccine generated robust cellular immunity in mice and led to significant reductions in viral loads in the nasal turbinates following challenge with a mouse-adapted SARS-CoV-2. These data suggest the potential utility of T-cell targeting of conserved regions for a pan-sarbecovirus vaccine.

60 APPLIED LIFE SCIENCES↗

Comparison of time-frequency-analysis techniques applied in building energy data noise cancellation for building load forecasting: A real-building case study

Time-frequency analysis that disaggregates a signal in both time and frequency domain is an important supporting technique for building energy analysis such as noise cancellation in data-driven building load forecasting. There is a gap in the literature related to comparing various time–frequency-analysis techniques, especially discrete wavelet transform (DWT) and empirical mode decomposition (EMD), to guide the selection and tuning of time–frequency-analysis techniques in data-driven building load forecasting. This article provides a framework to conduct a comprehensive comparison among thirteen DWT/EMD techniques with various parameters in a load forecasting modeling task. A real campus building is used as a case study for illustration. The DWT and EMD techniques are also compared under various data-driven modeling algorithms for building load forecasting. The results in the case study show that the load forecasting models trained with noise-cancelled energy data have increased their accuracy to 9.6% on average tested under unseen data. This study also shows that the effectiveness of DWT/EMD techniques depends on the data-driven algorithms used for load forecasting modeling and the training data. Hence, DWT/EMD-based noise cancellation needs customized selection and tuning to optimize their performance for data-driven building load forecasting modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Ideal Thermal Air Loads

This study provides hypothetical thermal heating and cooling loads for ComStock models representing the U.S. commercial building stock. This measure scenario removes all HVAC models from the baseline ComStock building model and instead uses "ideal air" to meet loads. "Ideal air" can be thought of as an HVAC unit that mixes air at the zone exhaust condition with the specified amount of outdoor air, and then adds or removes heat and moisture at 100% efficiency to produce a supply air stream at the specified conditions. The resulting ideal thermal loads are represented under the "district" fuel type for both heating and cooling and can be found in both annual and timeseries results in the ComStock public dataset. This measure scenario does not represent any real technology or improvement, but rather, serves as a resource for thermal heating and cooling loads for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MPC solution for optimal load shifting for buildings with ON/OFF staged packaged units: Experimental demonstration, and lessons learned

Small and medium-sized commercial buildings (SMCB) are significant demand response resources, and it is important to develop grid-responsive control algorithms that exploit those resources and create financial benefits for building owners and HVAC service providers. Furthermore, unlike large-sized commercial buildings, there is an opportunity to have universally applicable control solutions for many SMCBs since those buildings have a consistent HVAC system configuration: SMCBs are commonly served by multiple-staged air conditioning units controlled by their own thermostats. Despite the demand response potential and scalability, however, very few control solutions are available for SMCBs. Typical model predictive control (MPC) and heuristic control approaches for cooling load shifting that lower thermostat setpoints before an electric price jump are suitable mainly for large-sized commercial buildings where a continuous capacity modulation is possible, e.g., via dampers in variable air volume terminal units. However, those approaches can cause undesired, high peaks for SMCBs due to the nature of ON/OFF unit staging and narrow thermostat deadbands. This could discourage the use of advanced grid-responsive controls for SMCBs due to the concern of high demand charges, and has to be resolved. This paper presents a MPC solution that overcomes this challenge. It has a hierarchical MPC structure where an upper level MPC is responsible for electrical load shifting in response to an electric price signal while a lower level MPC is responsible for coordinating compressor stages to eliminate unnecessary peaks and follows the setpoints determined by the upper level MPC. In this work, two one-month, comprehensive laboratory tests have been carried out to demonstrate load shifting and cost savings for the algorithm. Interesting trade-offs between energy efficiency and load flexibility were observed and are discussed, and lessons learned for applying MPCs for SMCBs are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wind Turbine Rotor Design Optimization Using Importance Sampling: Preprint

Probabilistic methods are commonly adopted to estimate both ultimate and fatigue loads in wind turbines, and multiple papers have presented a variety of approaches. In contrast, system-level, integrated design optimization methods for wind turbines have so far relied on deterministic methods to estimate loads and deflections. This work aims at addressing this gap by adopting importance sampling to estimate ultimate blade deflection for use within a rotor design optimization. A comparison between the results of this approach against traditional approaches using deterministic load evaluations show that the probabilistic approach is more conservative and that the solutions found with deterministic approaches violate the probabilistic constraint on tip deflection between 13% and 17%. This highlights the importance of accurate load and deflection estimates and demonstrates that probabilistic approaches can be successfully integrated within a wind turbine design process despite the higher computational costs.

17 WIND ENERGY↗

2022 Summer Resource Adequacy in the ERCOT Region

This report is a 2022 update to the National Energy Technology Laboratory (NETL) report that examined the potential system performance of the Electric Reliability Council of Texas (ERCOT) system during the summer of 2021. Anticipated summer reserve margins in ERCOT have risen year-over-year from the 15.7 percent reported in ERCOT’s Final Seasonal Assessment of Resource Adequacy (SARA) for Summer 2021 to 22.8 percent in the Final SARA for Summer 2022, driven mostly by increases in wind and solar generation. Using data from ERCOT’s 2022 Summer SARA, Capacity, Demand and Reserves (CDR) reports, and historical performance data obtained from ERCOT and Hitachi Energy Velocity Suite, six economic dispatch scenarios using PROMOD were developed to assess the risk to ERCOT of a load shedding event for Summer 2022. The results suggests that ERCOT may be facing a very tight resource adequacy situation, with the potential for a serious shortfall during the summer peak, usually the end of July through mid-August, if demand and generator outage rates significantly exceed peak levels. Under these conditions, ERCOT will need to call on its operating tools, including Energy Emergency Alerts (EEA) and calls to conserve electricity, to maintain reliability and continue serving load. Those measures alone may not be sufficient to avert a shedding of load.

24 POWER TRANSMISSION AND DISTRIBUTION↗