Search NASA⌕ Search

SEARCH · Search NASA

Results for “container materials valves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

21 records · Page 2

Tracking Radioactive Isotopes in HVAC and Application for Hot Cell Analyses - 20155

In recent years, the surge in the number of isotope production facilities under design has increased the need to analyze isotope migration in facility Heating, Ventilation, and Air Conditioning (HVAC) during normal operations and accident scenarios. These facilities are used to produce isotopes for medical, security, and industrial applications and as such are subject to license and regulatory requirements 10CFR20, 10CFR30, 10CFR50, and 10CFR70. GOTHIC, a general-purpose thermal-hydraulics software package, includes the ability to model isotopic tracers, radioactive decay and isotope migration as well as HEPA and charcoal filters for isotope retention. A GOTHIC model was developed by Zachry Nuclear Engineering (ZNE) to examine the effect of negative room pressure, HEPA filtration, and HVAC fluctuations on radiation areas, hot cells and gloveboxes. Radioactive tracers were used to simulate the concentration of spills within contaminated areas, track the migration of isotopes of interest, and determine the isotopic retention and buildup on facility HEPA filters. A variety of isotopes with concern to dose (e.g., Kr-85, Sr-90, I-131, etc.), including their decay and progeny, are included in the analysis. Negative pressures are maintained in the regions of interest by a representative central HVAC system equipped with a volumetric fan that exhausts to the environment after a series of isolation valves and HEPA filters. GOTHIC is an industry trusted tool for providing engineering solutions for a variety of applications, including fission product tracking, aerosol and particulate transport and ventilation assessments. The software provides an integrated analysis environment that includes a graphical user interface (GUI) for constructing analysis models, a numerical solver that includes parallel processing capabilities and a post-processor for evaluating simulation results. It solves the conservation equations for mass, momentum and energy for multicomponent, multi-phase flow in lumped parameter and multi-dimensional geometries (1, 2, or full 3D), including the effects of turbulence, diffusion and buoyancy. It has been developed and maintained under a Quality Assurance program in compliance with the requirements of 10CFR50 Appendix B and applicable portions of ASME NQA-1 since 1995. GOTHIC has been used for assessing both forced and natural convection conditions for a wide range of applications, including: - Tracking concentration of hazardous gases and chemicals for habitability and safety assessments - Determining ventilation and filtration requirements and optimizing location and arrangement of these systems - Room heat-up, including diverse and Flexible coping strategies for Extended Loss of AC Power (FLEX/ELAP) - Equipment Qualification (EQ) A distinctive feature of GOTHIC is the ability to track many different fields/substances in a simulation, including user defined tracer elements, in the liquid, vapor and droplet fields as well as surfaces and filters. This capability allows GOTHIC to model fission product transport and release or the removal of particulates or harmful toxins from exhaust gases using a spray scrubber or other types of filtration systems. GOTHIC also includes models for engineered equipment, such as fans, filters, charcoal filters, dryers/demisters, dampers, etc. The aerosols and other filtered material are removed or accumulated in these components. The range of aerosol and radiological applications that GOTHIC has been used for includes: - Source Term: Primary Coolant (Equilibrium) Activity; Non-Water Coolant Source/Leakage. - Conditions for Iodine Re-evolution: Sump/Suppression Pool Conditions and pH; - RWST Conditions and pH. - Isotope Removal Mechanisms: Containment Sprayed and Unsprayed Region Mixing; Charcoal Filter Heating due to Iodine decay. - Radionuclide Transport and Decay: Post-LOCA Release in containment; Transport between connected Compartments and vent systems; Groundwater transport of radionuclides. - Non-Newtonian Fluid modeling for sludge, waste tanks, etc. ADAMS ML071581053 (titled 'Best Practice Guidelines for the use of CFD in Nuclear Reactor Safety Applications') poses guidelines for applying single phase CFD codes in nuclear reactor safety problems and GOTHIC is listed as a 'tool for 3D flows' and 'dispersal and deposition of radionuclides.' The Nuclear Quality Assurance (NQA) pedigree of GOTHIC is an important aspect for applications in the nuclear industry. The fundamental tracer models (convective transport, molecular and turbulent diffusion, removal mechanisms, etc.) have been verified using analytical solutions and validated against applicable separate effects tests. Also, GOTHIC has been benchmarked to many integrated effects tests, including Phebus FP (Fission Product). GOTHIC gives good agreement for the buildup and decay of fission products in Phebus Test 3. The model developed by ZNE demonstrates GOTHIC's applicability and acceptability for use in analyzing the migration and retention of radioactive isotopes and their progeny in normal operation and accident scenario analyses for isotope production facilities, hot cells, and gloveboxes. The tracer activities calculated by GOTHIC can then be used in downstream radiation transport and shielding codes like RADTRAD-NAI{sup C}, MCNP{sup R}, and MicroShield{sup R} to determine on-site and of-site doses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MAGNETICALLY SUSPENDED CANNED ROTOR PUMPS FOR THE INTEGRAL MOLTEN SALT REACTOR

This project developed a molten salt pump design for small modular reactors, concentrated solar, and Gen IV nuclear reactors with a magnetically levitated rotor that can operate at temperatures of up to 700 °C. This eliminates the need for rotating seals and roller element bearings which require maintenance and are prone to failure. The pump design is also more compact than existing molten salt pump designs which require long shafts to thermally isolate the electric motor. The aims of the project are to: 1) design and test the molten salt pump, 2) develop and test a high temperature position sensor needed for magnetic bearing control, and 3) develop and test high temperature coil fabrication methods for electric motor and magnetic bearing fabrication. To develop the high temperature coils, conductor materials were analyzed for oxidation, diffusion, cladding, and resistivity. Of the candidate conductor materials that met the requirements, silver was chosen. The long-term impact of radiation on silver resistivity was analyzed by developing a model of a generic molten salt fast reactor to model the conductor irradiation in worst case scenarios. The analysis showed that increased resistivity due to transmutation of silver decreases exponentially with the reactor reflector thickness. Different electrical insulation materials were tested and the final high temperature coils developed were able to withstand conductor to ground voltages up to 1800 V before insulation breakdown. Magnetic bearings require high-precision high-speed measurements of the rotor position to operate. Current commercial position sensors can only operate up to 550 °C so a novel position sensor was developed that can operate up to 800 °C. These sensors were also designed to measure the position of the metallic rotor through a thin metallic corrosion barrier that protects that coils, insulation, and magnetic cores so that the salt containment barrier does not have any penetrations. The high-temperature sensor was tested and had comparable performance to commercially available inductive position sensors. The sensor design and signal processing has led to several invention disclosures. The magnetically levitated molten salt pump design was completed and analyzed. The chloride salt test loop at Oak Ridge National Laboratory was chosen to test the pump and the pump hydraulics and power were designed for the test loop flow and pressure requirements. Classes of motor designs that do not utilize permanent magnetic were considered for the high-temperature motor. After extensive analysis of their performance, a synchronous reluctance motor was chosen for the pump. The design was refined and analyzed to optimize performance. The magnetic bearings were designed to meet the force and frequency requirements necessary to levitate the rotor and reject disturbances from rotor imbalance, motor forces, and hydraulic forces. Compliant mounts for the position sensors were designed that would not damage the ceramic sensor components and maintain sensor alignment over a wide temperature range. A thermal hydraulic analysis of the molten salt coolant flow used to cool the rotor and stator was performed to ensure that the maximum temperature in the rotor and stator will not exceed 725 °C. The corrosion barrier and casing were designed to maintain the salt fluid boundary by using compliant features to absorb large expansion mismatches due to different coefficients of thermal expansion (CTE). Finally, the salt drain and fill systems were designed along with the pump support structure, integration with the test loop, and thermal insulation and heating. Corrosion barrier fabrication experiments were performed to assess using laser cladding to apply a sub-millimeter corrosion barrier to the surface of a Fe-Co-V magnetic core material. The cladding method showed minimal mixing between materials at their interface and withstood temperature cycling without damage to the cladding. The technology commercialization is focused on the high-temperature position sensors and there has been significant interest from the nuclear industry in utilizing these sensors along with some interest from the aerospace industry. The project also led to a research collaboration with a fusion energy industrial partner to study barriers to scaling the pump design from the kW size to the MW size. This research collaboration will also study methods to create high-temperature coils that have conductor to ground breakdown voltages above 5 kV. The successful development of high-temperature electromagnetic coils and high-temperature position sensors greatly increases the temperature limits for electromagnetic devices that don’t rely on permanent magnets. This includes electric motors, magnetic bearings, linear actuators, rotary position and velocity sensing, actuated valves, and generators to name a few. This will fill a current need in molten salt reactors, concentrated solar, and fusion energy for these critical peripheral devices needed for practical reactor designs that do not currently have commercial solutions.

Hines, J Wesley↗

RELAP5-3D Modeling of High Temperature Test Facility (HTTF) Test PG-26

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors with prismatic fuel and reflector blocks. Several tests have been completed, and more are still planned to at the HTTF, including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This report analyses test PG-26, a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC. PG-26 has been performed at the HTTF between May 30 and June 30, 2019. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heaters. The DCC transient was initiated during the 50 th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test. Version 4.4.2ie of the RELAP5-3D computer code has been used to model the HTTF PG-26 test, and results have been compared to available high-quality measured data. The model used in this study is the quality-controlled HTTF RELAP5-3D model (HTTF base 2018-04-19 QA), originally developed by P. Bayless. The report includes RELAP5-3D results of the “base calculations” as well as some sensitivities to important uncertain model inputs, such as primary helium mass flow rate, core ceramic thermal properties, as well as heat evacuation and loop friction models. Using the base RELAP5-3D model predicts a countercurrent helium flow in the hot duct observed at the beginning of the DCC, but instead of going into a molecular diffusion mode, the model predicts the onset of natural convection. Increasing friction in the core and hot duct prevents the natural convection from happening in some of the simulations. Although some temperatures are well predicted (and even overpredicted), the general tendency is to underpredict the ceramic and helium temperatures and heat removal rates during the DCC, resulting in many of the assessment findings being in minimal or insufficient agreement with the data. It is worth noting that the described discrepancies between measured data and RELAP5-3D predictions are not RELAP5-3D code limitations. More so, they reflect limitations in boundary condition and thermal property knowledge. While the RELAP5-3D calculations of the test provide some insights into what happens during the transient, and point to missing or potentially uncertain data to which the experimenters can direct their attention, the principal conclusion is that the PG-26 test data are insufficient for a system code assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗