Search NASA⌕ Search

SEARCH · Search NASA

Results for “control simulation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Design Power Control Strategies of Grid-Forming Inverters for Microgrid Application

This paper develops and compares two control schemes in the application control layer of a non-phase-locked loop (non-PLL) grid-forming (GFM) inverter to gain insight and understanding into how the two schemes affect the dynamic responses of GFM inverters and the transition operation of microgrids. The first scheme adopts power tracking based on an outer current loop in grid-connected mode and droop control in islanded mode, and the second uses droop control in both grid-connected and islanded modes. Analytical study is developed to compare the performance of these two strategies from various aspects, including fundamental differences, transition operation, power tracking, and P-Q capability with low point-of-common-coupling (PCC) voltages. Extensive simulation testing is carried out to validate the control performance of these two control strategies, and the simulation testing confirms the findings of the analytic study. Finally, the second strategy is recommended because of its superior control performance and ease of implementation. The analysis and results are useful in developing reliable control schemes for non-PLL GFM inverters because increasing numbers of inverters will work as non-PLL grid-forming sources in future grids because of their improved stability and reliability.

grid-forming↗

Microreactor Automated Control System Test Bed Digital Architecture for Real-Time, Hardware-in-the-Loop Simulation

This work describes progress made towards the development of a real-time hardware-in-the-loop (HIL) test bed for non-nuclear testing of microreactor control schemes and failure modes. Non-nuclear testing is a crucial step in developing robust control algorithms for managing microreactor dynamics. The creation of an HIL simulation harnesses the realistic dynamics of physical analogue systems while additionally considering the challenges of variable communication delay. This collaborative effort between Oak Ridge National Laboratory and Idaho National Laboratory has resulted in a LabVIEW-based gRPC communication protocol which couples a TRANSFORM Modelica simulation of nuclear components to the ViBRANT physical hardware for realistic feedback and visual representation of control action in real time. A modular python client structure is developed to manage FMU-based Modelica simulation and real-time gRPC communication. HIL testing suggests that the modeled reactor with natural convection molten salt loop coolant configuration responds well to PID control of drum positioning for modulation of reactor core power, however, future efforts will be made to explore the added thermal inertial delay of system level control and downstream demand changes. Development of this platform with a generalized methodology provides a foundation for exploring a variety of reactor configurations and failure modes in rapid order to provide insight into the most effective avenues of study for further research and development.

McConnell, Jono [ORNL] (ORCID:0000000238984741)↗

Optimal control of the electron temperature profile in DIII-D using machine learning surrogate models

The viability of the tokamak as a potential fusion reactor depends on the ability to keep the plasma in a stable regime while achieving temperatures, densities, and confinement times that are as high as possible. Tokamak scenario development attempts to find plasma regimes that achieve all of these conditions and are accessible with a given set of hardware constraints. This requires the ability to control plasma properties such as the normalized beta, the internal inductance, safety factor, rotation, etc. One property that has received less attention than some of the others, but is no less critical to achieving high performance, is the electron temperature (T e ) profile. In this work, Linear Quadratic Integral (LQI) control is used to develop a controller for the electron temperature profile in DIII-D. The controller is based on a linearized model derived from the transport equation that describes the evolution of the electron temperature, and includes contributions from the neural network surrogate models NubeamNet and MMMnet. Furthermore, the controller is tested in simulation using COTSIM, and is proven capable of tracking a target T e profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Two-Level Model Predictive Control-Based Approach for Building Energy Management including Photovoltaics, Energy Storage, Solar Forecasting and Building Loads

This paper uses a two-level model predictive control-based approach for the coordinated control and energy management of an integrated system that includes photovoltaic (PV) generation, energy storage, and building loads. Novel features of the proposed local controller include (1) the ability to simultaneously manage building loads and energy storage to achieve different operational objectives such as energy efficiency, economic cost efficiency, demand response and grid optimization through the design of specific power trajectory tracking performance functionals, (2) an energy trim function that minimizes the impact of solar forecasting errors on system performance, and (3) the design of a state of charge controller that uses day-ahead forecast of solar power and building loads to intialize energy storage at the start of each day. The local controller is tested in simulation using an exemplary system with PV generation, energy storage and dispatchable building loads. Two sample days with different PV forecasts and multiple case scenarios are considered, and the performance of the algorithm in managing the real and reactive net building load trajectories and the ramp rate of PV injections into the utility network are evaluated. The simulations are based on actual forecasted and measured PV data, and the results show that the local controller meets the tracking requirements for real and reactive power within the operating constraints of the building.

14 SOLAR ENERGY↗

Development of control quality factor for HVAC control loop performance assessment—II: Field testing and results (ASHRAE RP-1587)

This article is the third paper from the research project RP-1587, focusing on presenting a comprehensive field test of the proposed control quality factors (CQFs; i.e., CQF-Harris and CQF-exponentially weighted moving average [EWMA]) and testing results. Firstly, the simulated control loops and real control loops are evaluated for offline assessment. Then, the field experiment implemented for different HVAC control loops is assessed online using the proposed CQFs. Test results show that the proposed CQFs are capable of adequately and effectively assessing the HVAC control loop performance. The methodology of obtaining those CQFs is provided in the companion paper: Development of Control Quality Factor for HVAC Control Loop Performance Assessment I - Methodology (ASHRAE RP-1587) (Li et al. 2019 Li, Y., Z. D. O'Neill, and X. Zhou. 2019. Development of control quality factor for HVAC control loop performance assessment I - Methodology (ASHRAE RP-1587).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep Reinforcement Learning for Residential HVAC Control with Consideration of Human Occupancy

The Artificial Intelligence (AI) development described herein uses model-free Deep Reinforcement Learning (DRL) to minimize energy cost during residential heating, ventilation, and air conditioning (HVAC) operation. Building cooling loads and HVAC operation are difficult to accurately model due to complexity, lack of measurements and data, and model specific performance, so online machine learning is used to allow for real-time readjustment in performance. Energy costs for the multi-zone cooling unit shown in this work are minimized by scheduling on/off commands around dynamic prices. By taking advantage of precooling events that take place when the price is low, the agent is able to reduce operational cost without violating user comfort. The DRL controller was tested in simulation where the learner achieved a 43.89% cost reduction when compared to traditional, fixed-setpoint operation. The system is now ready for the next phase of testing in a live, real-time home environment.

Mckee, Evan↗

Synthesis of Post-fire Monitoring Activities in the Great Basin Desert, Mojave Desert, and Transition Zones

In the deserts of the American Southwest, fire return intervals of centuries to millennia are being replaced by fire return intervals of decades. This increased burn frequency has implications for post-closure management and long-term stewardship for Soils Corrective Action Units (CAUs) and Corrective Action Sites (CASs) on the Nevada National Security Site (NNSS), Tonopah Test Range, and Nevada Test and Training Range for which the U.S. Department of Energy (DOE), Environmental Management-Nevada (EM-NV) is responsible. For many CAUs and CASs, where closure-in-place alternatives were implemented or are being considered, there is a chance that these sites could burn over while they still pose a risk to the environment or human health given the long half-lives of some of the radionuclide contaminants of concern (COCs) (Shafer et al., 2007; Shafer and Gomes, 2009). Although it would have been ideal to conduct a fire-related study at a radionuclide contaminated site on the NNSS to determine how contaminated soils are transported post-fire, it was more practical to examine fires in environments analogous to where Soils Activity CAUs and CASs exist. Therefore, a series of studies were initiated at three radiologically uncontaminated analog sites to better understand the possible effects of wildfire on erosion and sediment transport by wind and water should vegetation at contaminated sites burn at the NNSS. The studies took place at the sites of the Gleason Fire, a prescribed burn that occurred near Ely, Nevada, which is in the Great Basin ecoregion; the White Rock Fire that occurred near Mesquite, Nevada, which is in the Mojave Desert ecoregion; and the Jacob Fire that occurred near Hiko, Nevada, in the transitional zone between the Great Basin Desert and the Mojave Desert. Each site was representative of one of the three ecoregions found on the NNSS. Erosion and vegetation characteristics were measured multiple times post-fire on both burned and unburned test plots at these study sites to compare and monitor the effects of fire over time. However, at the Mojave Desert site, there was an additional burn from nearly 25 years ago that was also compared with the more recent burned areas from 2013. Also, the time elapsed after the fire and the time when sampling began differed among the ecoregions. For example, at the Great Basin site, samples were collected prior to the fire and less than one month after the fire, whereas data collected at the Mojave Desert site did not occur until 22 months after the fire. The differences between the sample measurements and the time that elapsed after the fire may contribute to the variability in the data and the interpretations of the data. Runoff and water erosion were quantified through a series of rainfall and runoff simulation tests in which controlled amounts of water were delivered to the soil surface. Runoff data were collected from different microhabitats (e.g., undercanopies, interspace soils, ridges, and drainage areas). The data showed soil hydrophobicity (i.e., water repellency) on the Great Basin site for up to 12 months after the fire. The soil structure remained changed and weaker on the burned areas compared with the unburned areas for the three-year study period. Although runoff data at both the Great Basin site and transition zone site were highly variable, the post-fire runoff potential did not generally increase at either location after three years of monitoring. Mojave runoff did not differ much between fire ages or between burned and unburned areas, possibly because of the amount of vegetation growing on all three surfaces and because the fire intensity was likely lower relative to other ecoregions due to the amount of space between plants. Additionally, the measurements conducted on the Mojave fire occurred several years after the fire had burned and not within several months of the burn, which may also account for the lack of differences in runoff between burned and unburned locations. Wind erosion was assessed and quantified with a Portable In-Situ Wind ERosion Lab (PI-SWERL) on both the burned and unburned soils of different microhabitats (e.g., ridges, drainages, interspaces between plants, and plant undercanopies). Estimates of emissions (e.g., particulate matter with aerodynamic diameters less than or equal to 10 micrometers, or PM10) at different wind speeds were collected and filter samples were analyzed for chemical composition. The measurements among the fires were similar and the results of the wind erosion measurements indicate that there were seasonal influences on many parameters, but the potential for PM10 windblown dust emissions was higher on burned areas compared with unburned areas. Among the burned areas, drainages produced the most dust emissions, whereas burned ridges were the least emissive. Emissions at the Mojave site and transition zone site were similar between burned and unburned areas approximately three years after the respective fires. Emissions remained much greater on burned soils at the Great Basin site. However, site selection may have also contributed to the differences of emissions among the three study locations. Post-fire vegetation responses were documented for three years following each fire in different microhabitats (e.g., ridge, drainage, undercanopy, and interspace) at the Great Basin and transition zone sites. In 2013, at the Mojave fire site, random permanent plots were established in newly burned areas, areas that burned approximately 25 years ago, and an unburned control area. At each fire site, the regeneration of native plant species dominated the burned areas, but invasive annual grasses were present at each fire site. During the course of each three-year study, the invasive annual grasses increased in density or percentage at both the Great Basin and transition fire sites but not at the Mojave site, where annual invasive grasses remained high throughout the study period. However, the chronosequence data from the Mojave site indicate a transition to different invasive grass species with time. The post-burn vegetation at all three ecoregions is still in the early stages of succession, and shrub size should increase over time and shrub density should decrease over time. However, the recovery of the plant communities to pre-burn compositions may not occur for decades or centuries, or may not occur because of changes in climate and the presence of invasive annual grasses. Results from the three study locations suggested that contaminated soils on the NNSS that experienced wildfire had the potential for soil erosion and transport of contaminated soils. Both wind and soil runoff studies indicated that locations in the Great Basin and transition zone ecoregions were more susceptible to erosion than the Mojave Desert ecoregion, but the highest levels of erosion occurred during the early portions of the study (the first 24 months) and the Mojave Desert was not measured until 22 months after the burn. Additionally, data from the Great Basin indicated deeper soils may increase susceptibility to wind erosion. Historically, the Great Basin and transition zone ecoregions burned more frequently than the Mojave Desert because of fuel abundance and connectivity—and they continue to burn more frequently, particularly after the introduction of invasive grasses (Davies and Nafus, 2013). However, both ecoregions and the transition zone have burned with extensive, high-severity fires when certain weather and fuel conditions are met. For example, the high abundance and productivity of annual grasses and forbs—which are usually produced by above average winter precipitation—combined with early spring and summer warm, dry conditions. Future climate scenarios predict increased temperatures, variable to reduced precipitation, and larger, more extreme wildfires throughout western North America. These predictions suggest that future fires on the NNSS could increase in frequency, intensity, and severity similar to their analog ecosystems throughout the Great Basin and Mojave Desert (Dennison et al., 2014; Abatzoglou andWilliams, 2016; Westerling, 2016).

54 ENVIRONMENTAL SCIENCES↗

Innovations in optimization and control of accelerators using methods of differential geometry and genetic algorithms (Final Report)

Online tuning of particle accelerators is necessary in order to achieve optimal machine performance. However, it is also a major challenge due to the large parameter space which must be searched and the fact that many of the desir- able objectives compete with one another, and so will not reach their optimal values simultaneously. In order to mitigate these issues, we have explored using dimension-reduction techniques to reduce the size of the parameter space which must be searched and multi-objective genetic algorithms to obtain the sets of tuning parameters which provide pareto-optimal values for the objectives. These methods have enabled us to obtain improved values of the vertical emittance at the Cornell Electron Storage Ring (CESR), and to do so with greater control of orbit errors. Algorithmic tuning is a multidisciplinary endeavour, requiring expertise in beam dynamics, diagnostics, control systems and computer science, and thus a key practical problem is to formulate a common language in which experts with different specialties can communicate. We developed a solution to this problem in the form of a generic accelerator software interface that allows for rapid prototyping of optimization and control algorithms. Our interface is built on the Experimental Physics and Industrial Control Systems (EPICS) and makes possible testing control code in simulation before deployment on real accelerators, as well as deployment of third-party optimization code.

43 PARTICLE ACCELERATORS↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

An Open-Source Virtual Testbed for a Real Net-Zero Energy Community

Net zero energy communities (NZECs) are critical to ensure sustainability and resilience of modernized power systems. System modeling helps overcome technical challenges in designing and operating NZECs. In this paper, we present the modeling work based on a real NZEC. Two sets of models are developed: higher-fidelity physics-based models considering the interaction between subsystems of the studied NZEC and capturing fast-dynamics; and lower-fidelity data-driven models requiring less resource to establish and/or run. All models are validated against measurements from this real NZEC. In addition, we create a simulation framework which streamlines the processes for simulation and thus allows using developed models to form a virtual testbed. To demonstrate the usage of the virtual testbed, a case study is conducted where a building-to-grid integration control is evaluated via simulation. The evaluation results suggest that the tested control significantly smooths the power draw of the studied community and doesn’t sacrifice the thermal comfort to a great extent.

Huang, Sen↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

GQuEST Control System Resolution

GQuEST (Gravity from Quantum Entanglement of Space-Time), is a collaboration verifying a quantum gravity model by measuring holographic effects on a microscopic scale. Its interferometer apparatus filters excessive optical noise and requires a control system that can adjust the filtration to accommodate for frequency changes in the output light. We stress-test this control system by simulating filter behaviors with parameters in their outermost regimes, and we have determined a threshold that maintains precision while minimizing resource usage. These results are important for the successful operation of GQuEST's interferometer, enabling more accurate tests of quantum gravity models and thereby advancing our understanding of gravity at the quantum mechanical level.

Nguyen, David↗

Evaluation of supply air temperature control performance with different control strategies at air handling units

Due to its nonlinear feature, supply air temperature control systems at air handling units using single-loop fixed gain control frequently suffer unstable response under dynamic conditions. This paper is aimed at identifying a more effective control strategy to stabilize the valve control and achieve desirable supply air temperature response under various operation conditions by evaluating three control strategies, cascade, gain scheduling and cascade plus gain scheduling controls. Firstly, a control-oriented model is developed and calibrated through open-loop tests. Then, the control issues with single-loop fixed gain control are evaluated through simulations and field tests, which indicates that the system has more aggressive response or becomes unstable under lower load conditions when the chilled-water flow rate is less than 0.1 L/s. Finally, three control strategies are proposed and evaluated. Further, the results reveal that all three proposed controls can achieve better robustness with the integral square error of supply air temperature decreased to 16%, 47% and 5%, respectively, under lower load condition. However, since high-frequency oscillation of the control valve occurs with cascade and cascade plus gain scheduling control, the gain scheduling control is recommended considering a trade-off among the supply air temperature response, valve lifetime and implementation complexity.

42 ENGINEERING↗

Using Qualified On-Site Nuclear Power Plant Simulators in Human Factors Validations of Control Room Upgrades

Existing commercial nuclear power plants (NPPs) are valuable assets in the infrastructure portfolio of the United States (U.S.) because they safely and reliably generate about 1/5th of all the electricity used. The instrumentation and control (I&C) systems in commercial NPPs are the ‘eyes and ears' of the operator, allowing operators to maintain situation awareness, thereby allowing the plant to operate safely and efficiently for all phases of operation. Because the I&C systems in NPPs are still mostly based on analog technologies, which are reliable but not especially cost-effective, upgrading the existing I&C in com-mercial NPPs to new digital I&C is very important. Furthermore, simulators and simulation are critical human factors engineering tools for this I&C modernization work. NPP control room simulators are essential test beds to simulate normal, abnormal, and emergency operations that allow human factors researchers to safely and realistically evaluate early design phase prototypes of the upgraded digital I&C, and validate final as-built digital I&C systems that have been modernized deployed in NPPs. This paper describes research performed using qualified on-site NPP simulators to perform human factors validations of digital I&C control room upgrades.

99 GENERAL AND MISCELLANEOUS↗

Optimization-Based Fast-Frequency Estimation and Control of Low-Inertia Microgrids

The lack of inertial response from non-synchronous, inverter-based generation in microgrids makes the power system vulnerable to a large rate of change of frequency (ROCOF) and frequency excursions. Energy storage systems (ESSs) can be utilized to provide fast-frequency support to prevent such large excursions in the system. However, fast-frequency support is a power-intensive application that has a significant impact on the ESS lifetime. In this paper, a framework that allows the ESS operator to provide fast-frequency support as a service is proposed. The framework maintains the desired quality-of-service (limiting the ROCOF and frequency) while taking into account the ESS lifetime and physical limits. The framework utilizes moving horizon estimation (MHE) to estimate the frequency deviation and ROCOF from noisy phase-locked loop (PLL) measurements. These estimates are employed by a model predictive control (MPC) algorithm that computes control actions by solving a finite-horizon, online optimization problem. Additionally, this approach avoids oscillatory behavior induced by delays that are common when using low-pass filters as with traditional derivative-based (virtual inertia) controllers. MATLAB/Simulink simulations on a test system from Cordova, Alaska, show the effectiveness of the MHE-MPC approach to reduce frequency deviations and ROCOF of a low-inertia microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Core Microcontroller Hardware In the Loop System for Electric Machine Control

Hardware in the Loop (HIL) is a simulation technique used to reduce the software development cycle and test control systems in a non-destructive environment. This work describes a cost effective HIL simulator on a dual core microcontroller in which one core acts as a controller and the other emulates the system under control. The emulator runs one step per Pulse Width Modulation (PWM) period in real time. To handle the computational burden and prioritize execution of simulation and control tasks, an interrupt-based software architecture with task prioritization has been developed. As a demonstration, the HIL has been implemented on a Texas Instruments TMS320F28379D dual core microcontroller, which emulates a Permanent Magnet Synchronous Machine (PMSM) with resolver feedback. Hardware peripherals are developed and tested concurrently with the control system, providing higher confidence in the software. By using the peripherals in the HIL development, the controller exercises either the HIL emulation or a pin compatible PMSM testbench. To quantify performance and validate the processor based emulator, the HIL results are compared to the preexisting testbench for accuracy benchmarking at no-load and under load for a range of operating points.

33 ADVANCED PROPULSION SYSTEMS↗

Integrated control of individual plasma scalars with simultaneous neoclassical tearing-mode suppression

A novel integrated-control architecture has been tested in nonlinear, one-dimensional simulations using the control-oriented transport simulator (COTSIM©) and in DIII-D experiments. Integrated architectures that can perform continuous-mission control while also handling off-normal events will be vital in future reactor-grade tokamaks. Continuous-mission controllers for individual magnetic and kinetic scalars (thermal stored-energy (W), volume-average toroidal rotation (Ω Φ ), and safety factor profile (q) at different spatial locations) have been integrated in this work with event-triggered neoclassical tearing-mode (NTM) suppression controllers by combining them into an architecture augmented by a supervisory and exception handling (S&EH) system and an actuator management (AM) system. Here, the AM system, which enables the integration of competing controllers, solves in real time a nonlinear optimization problem that takes into account the high-level control priorities dictated by the S&EH system. The resulting architecture offers a high level of integration and some of the functionalities that will be required to fulfill the advanced-control requirements anticipated for ITER. Initial simulations using COTSIM suggest that the plasma performance and its MHD stability may be improved under integrated feedback control. In addition, the integrated-control architecture has been implemented in the DIII-D plasma control system and tested experimentally for the first time ever in DIII-D in a high-q min scenario, which is a candidate for steady-state operation in ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗