Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Passive optical and infrared meteorology

Applications of passive visible and infrared techniques to the study of meteorological parameters are presented. For the remote sensing of temperature and humidity profiles, infrared sounder improvements have proceeded with the narrow band-pass channels approach, and the partially scanned interferogram approach. Current and planned infrared and microwave sea-surface temperature sounders have an expected accuracy of approximately 2 K, and this can be improved by using three super window channels from the 3.7 micron window region, with narrow band passes away from principal water vapor absorption lines. Cloud data remote sensing is currently performed from satellites, and these visible and infrared images have been used to track weather patterns. In addition, a passive infrared correlation-spectroscopy technique has been proposed for wind measurements. Finally, these techniques have also been applied to monitor such parameters as the Solar Constant, aerosols, and minor gas constituents.

Chahine, M. T.↗

Light Scattering Tests of Fundamental Theories of Transport Properties in the Critical Region

The objective of this program is to measure the decay rates of critical density fluctuations in a simple fluid (xenon) very near its liquid-vapor critical point using laser light scattering and photon correlation spectroscopy. Such experiments have been severely limited on Earth by the presence of gravity which causes large density gradients in the sample when the compressibility diverges approaching the critical point. The goal is to measure decay rates deep in the critical region where the scaled wavevector is the order of 1000. This will require loading the sample to 0.01% of the critical density and taking data as close as 3 microKelvin to the critical temperature (Tc = 289.72 K). Other technical problems have to be addressed such as multiple scattering and the effect of wetting layers. The ability to avoid multiple scattering by using a thin sample (100 microns) was demonstrated, as well as a temperature history which can avoid wetting layers satisfactory temperature control and measurement, and accurate sample loading. Thus the questions of experimental art are solved leaving the important engineering tasks of mounting the experiment to maintain alignment during flight and automating the state-of-the-art temperature bridges for microcomputer control of the experiment.

Gammon, R. W.↗

Passive remote sensing of stratospheric and mesospheric winds

A passive infrared sensor for remote sounding of the wind field in the stratosphere and mesosphere from near earth orbital spacecraft is described. The sensor utilizes gas correlation spectroscopy and electrooptic phase-modulation techniques to measure winds in the 20-120 km altitude range, temperature, and atmospheric species concentrations. The operation of the sensor is examined. The sensitivity of the sensor is small Doppler shifts in an observed spectrum and the performance of the instrument were evaluated using laboratory simulation and numerical modeling. The data reveal that the sensor's wind measurements should have an accuracy better than 5 m/s and a spatial resolution of 5 km vertical by 150 km horizontal.

Mccleese, D. J.↗

Ocean color spectral variability studies using solar-induced chlorophyll fluorescence

It is suggested that chlorophyll-induced ocean color spectral variability can be studied using only a passive airborne spectroradiometer instrument, with solar-induced chlorophyll fluorescence used as the standard against which all correlations are performed. The intraspectral correlation (ISC) method is demonstrated with results obtained during an airborne mapping mission in the New York Bight. The curvature algorithm is applied to the solar-induced chlorophyll fluorescence at about 690 nm, and good agreement is found with results obtained using active-passive correlation spectroscopy. The ISC method has application to spectral variability and resulting chlorophyll concentration measurement in different environmental conditions and in different water types.

Hoge, Frank E.↗

Critical fluid light scattering

Thermal fluctuations give rise to a host of thermodynamic anomalies near critical points. The background for these phenomena is presented, and an experiment design on STS flight experiment called 'Zeno' described. The objective is to measure the decay rates of critical density fluctuations in a simple fluid (xenon) very near its liquid-vapor critical point using laser light-scattering and photon-correlation spectroscopy. Such experiments have been limited on earth by the presence of gravity, which causes large density gradients in the sample. Fluctuation decay rates in xenon will be measured at least 100 times closer to the critical point than is possible on earth. This will require taking data as close as 145 microK to the critical temperature (Tc = 289.72 K), after locating it to + or - 10 microK. The minimum mission time of 100 hours will allow a complete range of temperature points to be covered, limited by the thermal response of the sample. An essential part of the apparatus is the thermostat. Its design principles and key features are given together with some observed performance characteristics of a prototype: + or - 20 microK stability for 18 hours, and one minute programmed step response for steps less than 10 mK.

Gammon, Robert W.↗

Oceanographic applications of laser technology

Oceanographic activities with the Airborne Oceanographic Lidar (AOL) for the past several years have primarily been focussed on using active (laser induced pigment fluorescence) and concurrent passive ocean color spectra to improve existing ocean color algorithms for estimating primary production in the world's oceans. The most significant results were the development of a technique for selecting optimal passive wavelengths for recovering phytoplankton photopigment concentration and the application of this technique, termed active-passive correlation spectroscopy (APCS), to various forms of passive ocean color algorithms. Included in this activity is use of airborne laser and passive ocean color for development of advanced satellite ocean color sensors. Promising on-wavelength subsurface scattering layer measurements were recently obtained. A partial summary of these results are shown.

Hoge, F. E.↗

Critical fluid light scattering

Thermal fluctuations give rise to a host of thermodynamic anomalies near critical points. The background for these phenomena is presented, and an experimental design on STS flight experiment called Zeno is described. The objective is to measure the decay rates of critical density fluctuations in a simple fluid (xenon) very near its liquid-vapor critical point using laser light scattering and photon correlation spectroscopy. Such experiments have been limited on Earth by the presence of gravity, which causes large density gradients in the sample. Fluctuation decay rates in xenon will be measured at least 100 times closer to the critical point than is possible on Earth. This will require taking data as close as 145 micro K to the critical temperature, after locating it to + or - 10 micro K. The minimum mission time of 100 hours will allow a complete range of temperature points to be covered, limited by the thermal response of the sample. An essential part of the apparatus is the thermostat. Its design principles and key features are given together with some observed performance characteristics of a prototype: + or - 20 micro K stability for 18 hours, and one minute programmed step response for steps less than 10 mK.

Gammon, Robert W.↗

Recent spectroscopic findings concerning clay/water interactions at low humidity: Possible applications to models of Martian surface reactivity

A feasibility study assessing the utility of the adaptation of near infrared correlation spectroscopy to quantifying iron and adsorbed water in some clay-based Mars soil analog materials (MarSAM's). The work was intended to constitute Phase 1 of an approach to identifying optical analytical wavelength regions, not only for important mineral classes, but for chemically active centers within them. Many of these centers are common to unrelated mineral classes and of disproportionate influence relative to the mineral structure as a whole in determining the surface reactivity of mineral surfaces. We previously reported linearity between reflectance and total iron and total moisture over a large range of both key variables. We also discovered interesting relationships between the intensity of iron bands and the relative humidity of the systems. These relationships were confirmed. We also show that, in the low humidity range, reflectance is linearly dependent on a different kind of water from that best representing the full humidity range (the kind of water associated, in clays, with surface acidity). These relationships and the sensitivity and capability of quantitation of near infrared data indicate high promise with the production of reactive surface intermediates of products of surface reactions.

Coyne, L.↗

Dynamic light scattering analysis of solutions from which lysozyme crystals grow

The variation of the friction factor was measured by photon correlation spectroscopy during isothermal growth of chicken egg white lysozyme crystals. It was observed to initially increase to a maximum as crystals formed, and then to decrease to a constant value. The change in the friction factors was measured as a function of temperature at concentrations of lysozyme varying from one sufficiently low that molecular interactions were undetectable to concentrations near those at which crystals grow in solutions, in all cases the ionic strength was below that required for crystallization.

Bishop, J. B.↗

Passive remote sensing of stratospheric and mesospheric winds

A passive infrared sensor is described for remote sounding of the wind field in the stratosphere and mesosphere from near Earth orbital spacecraft. The instrument uses gas correlation spectroscopy together with electro-optic phase modulation techniques to measure winds in the 20- to 120-km altitude range globally, both in the day and at night, and with a vertical resolution of better than the atmospheric scale height. Measurement of temperature and the amounts of key atmospheric species may also be made simultaneously and in coincident fields of view with the wind observations. The sensor is currently being developed at the Jet Propulsion Laboratory as a candidate for the upcoming NASA Earth Observation System.

Mccleese, Daniel J.↗

MOPITT - A gas correlation spectrometer for tropospheric Earth observations

MOPITT (Measurement of Pollution in the Troposphere) is an instrument that will fly on the EOS AM-1 Polar Orbiting Platform, to be launched in mid-1998. The instrument accurately measures the concentration of carbon monoxide (CO) and methane (CH4) gas in the troposphere, using novel and conventional gas correlation spectroscopy techniques. These techniques are used to measure both the column amount and the vertical profile of the two gases in the troposphere. The instrument is nadir viewing and has cross-track scanning ability. It measures upwelling IR radiation through the atmosphere in the 4.6-micron and 2.3-micron bands for CO detection, and 2.2-micron for CH4. The instrument performance is enhanced using Stirling cycle mechanical coolers to maintain the IR detectors at less than 100 K. MOPITT has a total of eight detector channels to measure the total column of atmospheric CH4 gas to a precision of 1 percent, and to measure CO profiles to a precision of 10 percent. The instrument is self-calibrating to ensure data validity using internal targets and an external cold space view.

Drummond, James R.↗

The use of multispectral thermal infrared image data to estimate the sulfur dioxide flux from volcanoes: A case study from Mount Etna, Sicily, July 29, 1986

We have found that image data acquired with NASA's airborne Thermal Infrared Multispectral Scanner (TIMS) can be used to make estimates of the SO2 content of volcanic plumes. TIMS image data are most applicable to the study of partially transparent SO2 plumes, such as those released during quiescent periods or nonexplosive eruptions. The estimation procedure is based on the LOWTRAN 7 radiative transfer code, which we use to model the radiance perceived by TIMS as it views the ground through an SO2 plume. The input to the procedure includes the altitudes of the aircraft and ground, the altitude and thickness of the SO2 plume, the emissivity of the ground, and altitude profiles of the atmospheric pressure, temperature, and relative humidity. We use the TIMS data to estimate both ground temperatures beneath a plume and SO2 concentrations within a plume. Applying our procedure to TIMS data acquired over Mount Etna, Sicily, on July 29, 1986, we estimate that the SO2 flux from the volcano was approximately 6700 t d(exp -1). The use of TIMS to study SO2 plumes represents a bridge between highly localized methods, such as correlation spectroscopy or direct sampling, and small-scale mapping techniques involving satellite instruments such as the Total Ozone Mapping Spectrometer or Microwave Limb Sounder. We require further airborne experiments to refine our estimation procedure. This refinement is a necessary preparation for the schedueled 1998 launch of the Advanced Spaceborne Thermal Emission and Reflectance Radiometer, which will allow large-scale multispectral thermal infrared image data to be collected over virtually any volcano on Earth at least once every 16 days.

Realmuto, Vincent J.↗

Recent Advances in Laser Remote Sensing

Current terrestrial and hydrographic laser remote sensing research and applications are briefly reviewed. New progress in airborne oceanic lidar instrumentation and applications is then highlighted. Topics include a discussion of the unique role of airborne active-passive (laser-solar) correlation spectroscopy methods in oceanic radiative transfer studies and satellite ocean color algorithm development. Based on a perceived need for high resolution laser-induced resonance Raman and atomic emission spectra of oceanic constituents, future airborne lidar transmitter and receiver configurations are suggested.

Hoge, Frank E.↗

Zinc Nucleation and Growth in Microgravity

We report our experiences with zinc nucleation in a microgravity environment aboard NASA's Reduced Gravity Research Facility. Zinc vapor is produced by a heater in a vacuum chamber containing argon gas. Nucleation is induced by cooling and its onset is easily detected visually by the appearance of a cloud of solid, at least partially crystalline zinc particles. Size distribution of these particles is monitored in situ by photon correlation spectroscopy. Samples of particles are also extracted for later analysis by SEM. The initially rapid increase in particle size is followed by a slower period of growth. We apply Scaled Nucleation Theory to our data and find that the derived critical temperature of zinc, the critical cluster size at nucleation, and the surface tension values are all in reasonably good agreement with their accepted literature values.

Michael, B. Patrick↗

Validation of the Measurement of Pollution in the Troposphere (MOPITT) Experiment by Ground-Based Infrared Solar Spectroscopic Measurements of Carbon Monoxide (CO) and Methane (CH4)

The goal of the MOPITT experiment is to enhance our knowledge of the lower atmosphere system and particularly how it interacts with the surface/ocean/biomass systems. The particular focus is the distribution, transport, sources and sinks of carbon monoxide and methane in the troposphere. The MOPITT instrument was launched on EOS TERRA satellite December 18, 1999. After the launch and until March 22, 2000 the MOPITT instrument was in engineering and calibration mode. Beginning March 23, 2000 through May 6, 2001 the instrument was in a science measurement mode with some calibration breaks. On May 7, 2001 a criocooler on a side B died and channels 1 - 4 became inoperational. The MOPITT resumed its scientific measurements on August 25, 2001 with channels 5 - 8. With some calibration breaks the instrument currently provides the data. The project has three elements to it: hardware, data analysis and modeling. The MOPITT instrument, on the NASA EOS Terra satellite, measures the upwelling infrared radiance. Using the technique of correlation spectroscopy, information regarding the distribution of atmospheric CO and CH4 can be extracted. By using appropriate data analysis techniques, concentration profiles of CO are currently obtained on a global basis at a reasonably high horizontal (approximately 22km) and vertical resolution (approximately 3km). Column amounts of methane will be derived over the sunlit side of the orbit. These profiles are assimilated into models to study the chemistry and dynamics of CO, CH4 and other constituents of the lower atmosphere.

Pougatchev, Nikita↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗

Determination of Spatial Distribution of Air Pollution by Dye Laser Measurement of Differential Absorption of Elastic Backscatter

This paper presents the results of an analytical study of a lidar system which uses tunable organic dye lasers to accurately determine spatial distribution of molecular air pollutants. Also described will be experimental work to date on simultaneous multiwavelength output dye laser sources for this system. Basically the scheme determines the concentration of air pollutants by measuring the differential absorption of an (at least) two wavelength lidar signal elastically backscattered by the atmosphere. Only relative measurements of the backscattered intensity at each of the two wavelengths, one on and one off the resonance absorption of the pollutant in question, are required. The various parameters of the scheme are examined and the component elements required for a system of this type discussed, with emphasis on the dye laser source. Potential advantages of simultaneous multiwavelength outputs are described. The use of correlation spectroscopy in this context is examined. Comparisons are also made for the use of infrared probing wavelengths and sources instead of dye lasers. Estimates of the sensitivity and accuracy of a practical dye laser system of this type, made for specific pollutants, snow it to have inherent advantages over other schemes for determining pollutant spatial distribution.

Ahmed, S. A.↗

MOPITT Mechanisms 16 Years In-Orbit Operation on TERRA

The 16th anniversary of the launch of NASA's Terra Spacecraft was marked on December 18, 2015, with the Measurements of Pollution in the Troposphere (MOPITT) instrument being a successful contributor to the NASA EOS flagship. MOPITT has been enabled by a large suite of mechanisms, allowing the instrument to perform long-duration monitoring of atmospheric carbon monoxide, providing global measurements of this important greenhouse gas for 16 years. Mechanisms have been successfully employed for scanning, cooling of detectors, and to optically modulate the gas path length within the instrument by means of pressure and gas cell length variation. The instrument utilizes these devices to perform correlation spectroscopy, enabling measurements with vertical resolution from the nadir view, and has thereby furthered understanding of source and global transport effects of carbon monoxide. Given the design requirement for a 5.25-year lifetime, the stability and performance of the majority of mechanisms have far surpassed design goals. With 16 continuously operating mechanisms in service on MOPITT, including 12 rotating mechanisms and 4 with linear drive elements, the instrument was an ambitious undertaking. The long life requirements combined with demands for cleanliness and optical stability made for difficult design choices including that of the selection of new lubrication processes. Observations and lessons learned with regards to many aspects of the mechanisms and associated monitoring devices are discussed here. Mechanism behaviors are described, including anomalies, long-term drive current/power, fill pressure, vibration and cold-tip temperature trends. The effectiveness of particular lubrication formulations and the screening method implemented is discussed in relation to continuous rotating mechanisms and stepper motors, which have exceeded 15 billon rotations and 2.5 billion steps respectively. Aspects of gas cell hermeticity, optical cleanliness, heater problems and SEU effects on accelerometers are also discussed.

Gibson, Andrew S.↗