Search NASA⌕ Search

SEARCH · Search NASA

Results for “cost study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Process Design and Techno-Economic Analysis of the Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Biomass

This work describes the process design and techno-economic analysis (TEA) of the modular SPOC power plant for biomass firing and coal-biomass co-firing. Two Rankine cycles were considered: a supercritical steam cycle (242 bar, 593°C, 593°C) with 550 MWe net output and a subcritical cycle (166 bar, 566°C, 566°C) with 200 MWe net output. For both cases, 95% carbon capture was modeled, and hybrid poplar biomass was chosen to generate carbon-negative power. In addition, the supercritical 500 MWe case included a 25% biomass co-firing (carbon neutral) case. For both cycles, a 100% Powder River Basin coal firing case was used for comparison purposes. In the SPOC process, oxygen is produced via a cryogenic air separation unit (ASU) and the heat generated from the compression of air is integrated into the steam cycle and utilized for boiler feed water pre-heating. Unique to the SPOC process, the boilers are pressurized and arranged in a series-parallel configuration, with minimized flue gas recirculation. The flue gas is cooled and scrubbed in the direct-contact cooler (DCC) column, and the moisture in the flue gas is condensed, leaving the bottom of the DCC at a sufficiently high temperature such that it can be used for boiler feed water pre-heating, improving plant thermal efficiency. Following drying and purification, CO2 in the flue gas is at the purity required for storage or utilization. The performance data were obtained from process modelling via Aspen Plus®. The stream data from Aspen Plus® were used as an input for the AACE Class 5 cost study. Ultimately, the capital costs, Levelized Cost of Electricity (LCOE), and cost of CO2 captured and avoided were obtained. The HHV efficiency of the carbon negative 550 MWe supercritical SPOC case (34.8%) was clearly above those reported by NETL for the BECCS baseline cases of supercritical pulverized coal with capture (B12B, 31.5%) and the 49% biomass co-firing case with capture (PA3, 29.2%). The HHV efficiency of the carbon-negative subcritical plant is also higher than the subcritical baseline PC plant with capture (case B11B.95) presented by NETL (32% vs 29.7%). The LCOE for the SPOC 100% biomass case was similar to the LCOE for the BECCS 49% biomass with carbon capture case ($147/MWh), and the SPOC carbon neutral case LCOE was lower ($110/MWh) than the cost for the NETL baseline SC coal firing case with 90% carbon capture ($114/MWh).

Magalhaes, Duarte↗

Data Analysis of Energy Code Compliance in Commercial Buildings

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. The field study team implemented the pilot methodology, compiling a data set of 230 office and retail buildings in two climate zones. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This report is focused on the analysis of the collected data. The primary goal was to analyze the data collected during the field study and determine the actual energy cost impact of each measure in a non-compliance situation. The energy impact results allowed for ranking the measures to identify which have the highest potential for lost savings. These results combined with the time required to verify each measure will allow future compliance verification to focus on measures that had a large impact on energy use over the life of the building and those that have the greatest savings recovery potential per verification hour.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Analysis of Energy Code Compliance in Commercial Buildings (Rev. 1)

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. The field study team implemented the pilot methodology, compiling a data set of 230 office and retail buildings in two climate zones. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This report is focused on the analysis of the collected data. The primary goal was to analyze the data collected during the field study and determine the actual energy cost impact of each measure in a non-compliance situation. The energy impact results allowed for ranking the measures to identify which have the highest potential for lost savings. These results combined with the time required to verify each measure will allow future compliance verification to focus on measures that had a large impact on energy use over the life of the building and those that have the greatest savings recovery potential per verification hour.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Commercial Energy Code Compliance – Just the Facts, Ma’am

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. This paper builds on the methodology presented at the 2016 Summer Study and provides a first glimpse of the results as seen in the field. The field study team has implemented the pilot methodology, compiling a data set of over 200 office and retail buildings in climate zones 2A and 5A. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This paper will review the findings of that analysis, discuss critical aspects of the methodology, such as sampling and recruitment strategies, and identify areas where the greatest return—bang for the buck—exists in improving compliance with codes in commercial buildings. In addition, the team will make specific recommendations for jurisdictions looking to use the methodology to maximize energy code savings achieved in the field.

Cheslak, Kimberly↗

Matrix Approach to Accelerate Spin-Up of CLM5

Numerical models have been developed to investigate and understand responses of biogeochemical cycle to global changes. Steady state, when a system is in dynamic equilibrium, is generally required to initialize these model simulations. However, the spin-up process that is used to achieve steady state pose a great burden to computational resources, limiting the efficiency of global modeling analysis on biogeochemical cycles. This study introduces a new Semi-Analytical Spin-Up (SASU) to tackle this grand challenge. We applied SASU to Community Land Model version 5 and examined its computational efficiency and accuracy. At the Brazil site, SASU is computationally 7 times more efficient than (or saved up to 86% computational cost in comparison with) the traditional native dynamics (ND) spin-up to reach the same steady state. Globally, SASU is computationally 8 times more efficient than the accelerated decomposition spin-up and 50 times more efficient than ND. In summary, SASU achieves the highest computational efficiency for spin-up on site and globally in comparison with other spin-up methods. It is generalizable to wide biogeochemical models and thus makes computationally costly studies (e.g., parameter perturbation ensemble analysis and data assimilation) possible for a better understanding of biogeochemical cycle under climate change.

54 ENVIRONMENTAL SCIENCES↗

Resilience and economics of microgrids with PV, battery storage, and networked diesel generators

Current designs and assessments of microgrids have ignored component reliability, leading to significant errors in predicting a microgrid’s performance while islanded. Existing life cycle cost studies on hybrid microgrids—which combine photovoltaics (PV), battery storage and networked emergency diesel generators—also have not identified all the potential economic opportunities. Reducing the number of emergency diesel generators through reliance on PV and battery, retail bill savings, and demand response and wholesale market revenue streams are all important. This paper provides a new statistical methodology that calculates the impact of distributed energy reliability and variability on a microgrid’s performance and a novel use of the optimization platform REopt to explore multiple cost savings and revenue streams. We examine the impacts for microgrids in California, Maryland, and New Mexico and show that a hybrid microgrid is a more resilient and cost-effective solution than a diesel-only system. Under realistic conditions, a hybrid microgrid can provide higher system reliability when islanded and have a lower life cycle cost under multiple market conditions than a traditional diesel generator-based system. The improved performance of the hybrid system is resilient to conditions experienced over the last 20 years in solar irradiance and sees little degradation in performance immediately after a hurricane. The cost savings to provide this more resilient backup power system as compared to a diesel-only microgrid are significant. The net present cost for a hybrid microgrid is 19% lower in New Mexico and 35% lower in Maryland than a diesel-only microgrid. In California, the net present cost of the hybrid microgrid is negative because, unlike a diesel-only microgrid, a hybrid microgrid has lower life cycle costs than the power costs without a microgrid.

25 ENERGY STORAGE↗

Reducing microgrid availability to reduce costs for coastal Puerto Rican communities

Renewable microgrids are sustainable, resilient solutions to mitigate and adapt to climate change. Making electric loads nearly 100% available (i.e., power remains on) during outages increases cost. Near 100% availability is required when human life or high-cost assets are involved, but availability can be reduced for less consequential loads leading to lower costs. This study analyses costs for photo-voltaic and lithium-ion battery microgrids with availability ranging from 0–99%. We develop a methodology to analyse three Puerto Rican coastal communities. Here, we consider power outage effects for hurricanes, earthquakes, and everyday outages. The results show cost versus availability from 0–99%. There is 27–31% cost reduction at 80% availability in comparison to 99% availability. A regression model of microgrid availability versus three ratios: 1) the annual generation to demand ratio, 2) storage to interruption energy ratio, and 3) peak storage to load ratio produced a coefficient of determination of 0.99949 with 70% of the data used for training and 30% for testing. The results can therefore be extended to other coastal Puerto Rican communities of varying sizes that have ratios within the ranges analysed in this study. This can empower decision makers to rapidly analyse designs that have availabilities well below 100%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Facebook to Recruit Urban Participants for Smartphone-Based Travel Surveys

Social media has become an integral part of everyday life for many individuals, serving as a platform to express opinions, share memories and lifestyles, follow news, and adapt to social trends and norms. The wealth of user information and analytics on these platforms has facilitated the development and sale of tailored products and services, benefiting advertisers and researchers seeking survey participants. Social media advertising has demonstrated its effectiveness in reaching hard-to-reach populations. However, transport researchers have yet to capitalise on this potential fully. This paper presents our experience using social media to recruit participants for two smartphone travel surveys conducted in Australia. We demonstrate that social media recruitment and smartphone-based travel surveys are highly effective, adaptable, and can be rapidly deployed in response to research opportunities, such as during the early phase of the COVID-19 pandemic when traditional methods may be less suitable. This approach also holds great potential for travel surveys targeting the general population. This paper shares several lessons from this experiment, including our administrative approach and detailed technical instructions to utilise open-source software tools for conducting smartphone travel surveys like ours. This approach significantly reduces study costs compared to most commercial solutions.

97 MATHEMATICS AND COMPUTING↗

Assessment of Offshore Wind Energy Leasing Areas for Humboldt and Morro Bay Wind Energy Areas, California

The National Renewable Energy Laboratory (NREL) is providing scientific and technical services to the Bureau of Ocean Energy Management (BOEM) under an interagency agreement. The purpose of this report is to provide technical assistance in delineating potential lease areas from the California wind energy areas (WEAs) that can be competitively auctioned to wind energy developers. Each wind energy area is presumed to be technically and economically feasible for wind energy development based on the economic cost study performed by NREL in 2020. The subsequent analysis summarized in this report is intended to help BOEM maximize efficient offshore wind energy resource use and ensure fair return to the Government for use of the lease areas, by making recommendations for viable ways to divide the WEAs into auctionable commercial lease areas of approximately equal value. We considered several factors that affect the value of lease areas for wind energy development, including mean wind speeds, water depth, seafloor gradient, seismicity, hard substrate, and access to infrastructure. The largest impact to generating capacity came from the choice of mooring technology and the resulting setback from the lease area boundaries. Based on our setback assumptions, the generating capacity for a wind plant using catenary moorings could be nearly 30% less than with vertical moorings in Humboldt, or approximately 20% less in Morro Bay. The likely range of generating capacity is 1.5 to 3 GW in Humboldt and 3 to 5 GW in Morro Bay.

17 WIND ENERGY↗

DOE’s National Solar Thermal Test Facility Operations and Maintenance

This report details operations and maintenance (O&M) activities performed across Fiscal Years 2022 through 2024 in support of the continued capabilities of the National Solar Thermal Testing Facility (NSTTF) at Sandia National Laboratories. The NSTTF O&M project is funded by the U.S. Department of Energy Solar Energy Technologies Office (SETO) to support research activities and testing on behalf of external customers at the facility under award number CPS 38491. During the project period, the NSTTF made progress in the areas of site metrics, site maintenance and utilization tracking, and customer engagement. The O&M project also supported special initiatives including procurement of a heat exchanger for particle concentrating solar thermal processes and a scoping and cost study for refurbishment and repair of component in the NSTTF heliostat field.

14 SOLAR ENERGY↗

Collaborative Approach to Identify Degradation Mechanisms and Validate Aging Protocols for a Diverse Set of DAC Materials (TCF Base Technology-Specific Final Report)

This work supports the mission of the U.S. Department of Energy to promote American energy leadership, technological innovation, and economic growth through the development of technologies for cost effective carbon capture. While capture technologies can provide carbon dioxide for enhanced oil recovery, many capture materials suffer from oxidative, hydrolytic and/or thermal degradation which leads to capacity loss and unwanted emissions such as ammonia. Short lifetimes increase operational costs and cost studies suffer from uncertainty because the true lifetimes of many capture materials are unknown. In this study, a suite of capture materials were studied to quantify their degradation, provide insight into the mechanisms that lead to their uptake loss and provide validated accelerated aging protocols for industry.

36 MATERIALS SCIENCE↗

A Study of Cost-Saving Potential of Load Flexibility Measures in Grid-Interactive Multifamily Buildings

With recent advances in smart technologies, more and more smart devices are penetrating the residential and commercial buildings market. The introduction of these smart devices is also helping IoT companies emerge with load aggregator roles in the sector. With more utility companies on the track of supporting OpenADR protocols, the aggregators could play a significant role in providing load flexibilities by automatically responding to demand response (DR) events and coordinating load flexibility measures between customers. This would benefit utility companies by reducing stress on the grid during critical peak demand hours as well as customers by allowing them to utilize utility rate structures advantageous to those able to reduce electric usage during high-demand hours. This study evaluates cost and energy savings from adopting multiple load flexibility measures in multifamily buildings. Combinations of different load flexibility measures, including space temperature floating, light dimming, automatic window shading, and water heater temperature floating, are considered. The simulations are performed using OpenStudio®, an open-source U.S. Department of Energy (DOE) simulation platform. For the case study, we used a midrise apartment building with weather conditions from Denver, Colorado. To compare climate zone differences, simulations were also performed for Los Angeles, California, and Chicago, Illinois. Initial results indicate that the application of automated load flexibility measures without careful consideration of dispatching strategies and DR program enrollments could significantly affect the savings. To get meaningful cost savings, aggregators need to encourage tenant awareness to curtail energy usage through occupant behavior in addition to dispatching automatic load flexibility measures. The outcomes from this study are believed to help load aggregators understand the risks and benefits of load flexibility opportunities.

building energy modeling↗

A Study on Computational Cost Reduction of Simulations of Phase-Change Material (PCM) Embedded Heat Exchangers

Thermal storage can be implemented using Phase-Change Materials (PCM), which absorb significant latent heat with a relatively small temperature change. PCM phase-change processes are transient and are driven by thermal diffusion and natural convection – the latter, especially for melting process. Modeling and simulation of PCM heat exchangers (HX’s) is typically computationally intensive due to the relatively complex time-dependent physics. Most of the PCM modeling work in the literature uses high-order modeling tools such as Computational Fluid Dynamics (CFD) and Lattice-Boltzmann Method (LBM). For design purposes, the existing PCM modeling approaches are not practical, limiting researchers in their ability to investigate new ideas and different PCM’s with faster turnarounds. This paper presents a study investigating the reduction of computational cost of PCM embedded HX’s CFD models by evaluating the feasibility of spatial reduction without losing accuracy. The analysis consists of comparing full and partial domain under full melting conditions. The subject of this study is a single straight tube with circular transverse fins in the vertical orientation, using PCM’s with 35oC nominal melting temperature. Different tube and fin dimensions are investigated. Results indicate that the reduced domain reproduces - in half the run time - the same behavior as the full domain since the buoyancy effects are localized and patterned. The outputs from the partial domain simulation were used to build a non-general correlation for the PCM heat transfer characteristics and demonstrated how it can be implemented in a Finite Control Volume Reduced Order Model (ROM). The ROM can accurately reproduce the CFD simulations at 4 to 5 orders of magnitude faster.

25 ENERGY STORAGE↗

Cost-Benefit Analysis of Grid-Supportive Loads for Fast Frequency Response

Flexibility in inverter-based loads could be used to support the converter-dominated power grid by offering a rapid, autonomous, and adjustable power reserve during system transients to help maintain system stability. Based on technical potential, ancillary service (AS) value, and implementation costs, this study illustrates the cost-benefit analysis of grid-supportive loads (GSLs) for the supply of fast frequency response (FFR). The net benefit for each GSL is demonstrated using a case study and relevant data sources. The findings suggest that implementation costs for enabling GSL features are low compared to the value that grid operators get from the acquisition of responsive reserve services. The authors believe that, given the rising popularity of renewable energy sources, GSLs can be a useful tool for grid stability in low-inertia systems.

cost-benefit analysis↗

Evaluating the Impacts of the Bipartisan Budget Act of 2018 45Q Tax Credit on CCS Network Costs

This study evaluates the impact of the Bipartisan Budget Act of 2018 (BBA)-amended 45Q tax credit on integrated carbon capture and storage (CCS) networks for source types and geologic storage reservoirs common to the north-central U.S. The integrated CCS networks evaluated were chosen to closely replicate those in the forthcoming National Energy Technology Laboratory (NETL) central U.S. CCS cost options study’s Northwest CCS Network Regional Impact Area (Northwest Impact Area).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Updated Oregon Floating Offshore Wind Cost Modeling [Slides]

The study provides heat maps showing updated estimates of the levelized cost of energy (LCOE) for floating offshore wind energy off the coast of Oregon. This project builds on a 2019 National Renewable Energy Laboratory (NREL) floating offshore wind power cost study in Oregon (Musial et al. 2019) and a recent NREL California cost analysis (Beiter et al. 2020). Floating wind power cost data, modeling methodology, and resource data are updated and LCOE is estimated through 2032 using 2019 as a reference year. Comparisons are made to the previous offshore wind energy cost studies (Musial et al. 2019; Beiter et al. 2020). The study does not prioritize specific sites or make judgments about marine spatial planning viability.

17 WIND ENERGY↗

EXPERIMENTAL STUDY ON COST-EFFECTIVE ADDITIVE MANUFACTURING OF SILICA AEROGEL

The conventional aerogel insulation material manufacturing from supercritical drying suffers from issues of massive energy consumption and prolonged processing time. With the consideration of large market demand of the aerogel insulation material in the next decade, a low-cost and scalable fabrication technique is highly desired. In this paper, a direct ink writing (DIW) method is used to three-dimensionally fabricate the silica aerogel insulation material, followed by ambient pressure drying. Compared to the supercritical drying and freeze drying, the reported method significantly reduces the fabrication time and costs. The cost-effective DIW technique offers the capability to print complex hollow internal structure, coupled with the porous structure, is found to be beneficial to the thermal insulation property. The addition of fiber to the ink assures the durability of the fabricated product. The foam ink preparation methods and the printability are demonstrated in this paper, along with the printed samples for characterizing thermal insulation properties and mechanical properties.

42 ENGINEERING↗