Search NASA⌕ Search

SEARCH · Search NASA

Results for “criticality safety evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A High-Assay Low-Enriched Uranium Fuel Transportation Concept

The uranium 235U enrichment commonly used in fuel production for U.S. light water nuclear reactors typically does not exceed 5 wt%. In contrast, many of the currently investigated advanced reactor concepts demand fuel with higher enrichments. This includes high-assay low-enriched uranium (HALEU), characterized by a 235U enrichment of 5 to 20 wt%. The necessity of HALEU transportation in the fuel production cycle leads to new challenges caused by various technical and regulatory hurdles. Current U.S. Nuclear Regulatory Commission–approved transportation package designs for UF6 with enrichments above 5 wt% provide relatively small payloads [=116 kg (250 lb)]. Furthermore, in accordance with 10 CFR 71.55, package design activities for fissile material enriched above 5 wt% need to consider water infiltration in the containment as part of the criticality safety evaluations. This study presents a transportation package concept for HALEU advanced nuclear reactor fuel with a significantly higher payload of up to 376 kg (830 lb) of fissile material per package and up to 1881 kg (4149 lb) of HALEU per legal weight truck. The anticipated chemical form of the transported material is UO2 downblended from available highly enriched uranium. The concept utilizes a combination of existing transportation packaging, 18 inner canisters, and a novel basket design that includes a borated aluminum flux trap. Criticality and shielding evaluations; fundamental structural, confinement, and thermal assessments; and studies on package operations are presented. The results of this study build significant confidence in the technical feasibility of a high-capacity HALEU transportation package concept while demonstrating the concept’s potential to meet U.S. regulatory requirements.

Eidelpes, Elmar↗

ORNL/TM-2021/2046 Appendix data repository

Repository of data files used to generate plots for Post-Closure Nuclear Criticality Safety Evaluations for Disposition of Criticality Control Overpacks at the Waste Isolation Pilot Plant (ORNL/TM-2021/2046). See the readme for information contained in the individual files. See the report for description of the models used to generate the data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ORNL Testing of Multiple Graphite Benchmarks [Slides]

Integral criticality safety and reactor physics benchmark experiments from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) and the International Handbook of Reactor Physics Experiments (IRPhE Handbook) are essential for nuclear data validation and testing

ENDF↗

Impact of Increased Latent Generations on Sensitivity Calculations with SCALE

Analyses of cross section sensitivity data from systems with fissile material allow analysts to associate an importance for each material, nuclide, reaction, and neutron energy by simulating real world criticality scenarios. Although criticality safety validation efforts can be guided by the cross-section sensitivity and uncertainty data generated for a particular system, these calculations can often be computationally expensive and sometimes cumbersome without proper guidance. The TSUNAMI suite within the SCALE code package has several methods for generating sensitivity data, including multigroup and continuous energy (CE) capabilities. The release of SCALE 6.3 has three different CE methods for generating cross section sensitivity data: (1) the Iterated Fission Probability (IFP) method with the KENO Monte Carlo transport solver, (2) the IFP method with the Shift Monte Carlo transport solver, and (3) the Contributon-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance CHaracterization (CLUTCH) method with the KENO Monte Carlo transport solver. Although the CLUTCH method has additional parameters for generating sensitivity data files relative to the IFP method, all three methods use latent generations, which are the generations between an event (i.e., fission) and the assessment of importance based on the asymptotic population of progeny neutrons. Increasing the number of latent generations in a calculation leads to increased discrimination of the sensitivity coefficients but at the cost of the increased uncertainty associated with those generated values. Analysts must balance the accuracy of the sensitivity calculations and its uncertainty with the associated computational cost involved in generating the values. This paper discusses the impact of adjusting the latent generation parameter for a range of sensitivity values and how these changes compare with the direct perturbation values obtained from a change of ±0.5% Δ k in both benchmark and safety application models. Two benchmarks from the International Handbook of Evaluated Criticality Safety Benchmark Experiments and the MPC-32 dual purpose canister for spent nuclear fuel are used for analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Criticality Safety Pipeline Course - LLNL [Slides]

This presentation details the nuclear criticality safety pipeline course. An educational program from University of California, Berkeley. This course touches on nuclear criticality each fall semester. The curriculum instructs on the fundamentals of criticality safety and provides hands on experience with special nuclear material. This presentation covers lecture topics, project overview, and major criticality safety evaluation projects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sulfur Pellets Responses to a Bare and Steel Reflected Pulse of the Oak Ridge National Laboratory Health Physics Research Reactor

The experiments analyzed in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the $\textit{Fast Burst Reactor}$. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. The HPRR was an unmoderated, unshielded fast reactor that used highly enriched uranium and molybdenum alloy as fuel. The reactor was initially sent to the Nevada Test Site in 1962, where it was used to evaluate radiation doses received as a result of the Hiroshima and Nagasaki bombings during World War II. A few years later, the reactor was sent back to ORNL to be part of the Dosimetry Application Research (DOSAR) facility shown in Figure 1, which included a reactor building shown on the left (west) of the picture and a control and laboratory building in the upper right corner (northeast). The critical assembly was used for numerous technical studies, including systems calibration, dosimetry, radiobiology of plants and animals, testing of radiation alarms, as well as teaching and training in radiation dosimetry and nuclear engineering. Between 1963 and 1987, the HPRR was operated for thousands of hours, achieving criticality close to 10,000 times and motivating many publications. The HPRR was decommissioned in 1987. The goal of this effort was to use historical data from operation of the HPRR to create a criticality accident alarm system (CAAS) benchmark to be included in the $\textit{International Handbook of Evaluated Criticality Safety Benchmark Experiments}$ (ICSBEP Handbook). A thorough inspection was performed of all available documentation and information available. The most promising experiments that were selected for evaluation were those described in the 1987 ORNL report entitled $\textit{Health Physics Research Reactor Reference Dosimetry}$, ORNL-6240. The report includes reference dosimetry results of the shielded and unshielded configurations of the HPRR after burst operations. Because of changes to the reactor positioning and storage systems that were made in 1985, the previous dosimetry reports became obsolete, and the newly designed experiments were needed to create the HPRR’s adjusted dosimetry data. The various results reported in ORNL-6240 include reference doses and dose equivalents from different conventions at different distances and elevations as determined using the detected neutron fluence and conversion factors. The HPRR neutron fluence was obtained through different methods, including sulfur pellet analysis and threshold detector unit data. Information about the HPRR spectrum was also obtained through Bonner sphere measurements. This benchmark is focused on a part of the measured sulfur fluences reported in Appendix H of ORNL-6240. Standard commercial sulfur pellets were placed at different distances from the HPRR centerline during burst operation and were activated due to the 32 S(n,p) 32 P reaction. The resulting 32 P activity was then measured and the information about the corresponding sulfur fluence and/or neutron dose could be extracted. Many of those measurements have 7 been performed with the HPRR in its bare configuration or with different shields (combinations of Lucite, concrete, steel). All the necessary, precise information about material and/or dimensions of the different shields was not found, so it was decided to focus only on the unshielded and steel-shielded configurations to minimize the benchmark uncertainty. A total of 31 cases (24 unshielded and 7 shielded cases at different positions) of sulfur fluence were selected before evaluation to develop the benchmark.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

S/U Comparison Study with a Focus on USLs

Under a DOE Nuclear Criticality Safety Program (NCSP) task involving Analytical Methods, three Laboratories collaborated in a comparison of results obtained from Sensitivity/Uncertainty (S/U) packages relevant to validation of transport codes. The task involves Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Oak Ridge National Laboratory (ORNL) comparing results of MORET 5/MACSENS V3.0, MCNP6.2/Whisper-1.1, and SCALE 6.2.3/TSUNAMI/USLSTATS respectively. All Monte Carlo transport code results utilize ENDF/B-VII.1. Four cases from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) were selected as application models: HEU-MET-FAST-013-001, HEU-SOL-THERM 001-008, PU-MET-FAST-022-001, and PU-SOL-THERM 001-001. Ultimately, comparison is made between Upper Subcritical Limits (USLs) obtained using each code package for each application case. Since differences exist in whether packages take into account margin of subcriticality (MOS), the USL may be computed using bias and bias uncertainty, also known as the calculational margin (CM) in ANSI/ANS 8.24. Application of portions of MOS to the USL for nuclear data uncertainty of and potential code margin is referred to as USL herein. In either case, additional MOS is considered for actual application cases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Developing a New Criticality Safety Hands-On Training Utilizing ZPPR Plates

Nuclear criticality safety is an extremely important part of the work at Los Alamos National Laboratory (LANL). As part of the work LANL performs to continue to keep criticality safety a top priority, LANL has developed and regularly teaches nuclear criticality safety training classes for both the United States Department of Energy Nuclear Criticality Safety Program as well as internal trainings for LANL employees. A portion of the training classes is comprised of hands-on demonstrations, where students get the opportunity to handle special nuclear material at the National Criticality Experiments Research Center (NCERC). One hands-on demonstration uses the “Class foils,” thin HEU foils which are stacked with lucite moderator plates. A hand-stack is performed until the multiplication reaches the “three-quarters rule,” where the demonstration is continued remotely on a vertical lift assembly up until the system is critical. This hands-on demonstration eventually achieves a critical configuration and follows the ANS-1 guidelines on an approach to critical. Another hands-on demonstration involves handling clad plutonium and neptunium spheres, and follows procedures using criticality safety evaluations to ensure that the hands-on demonstrations remain subcritical.This hands-on demonstration also involves the use of polyethylene shells around the plutonium sphere to demonstrate how additional reflector increases the criticality of a system. This paper is focused on developing a new hands-on demonstration using Zero Power Physics Reactor (ZPPR) plates. This new hands-on demonstration will follow the ANS-8 standards as it is not desired to achieve criticality with the ZPPR plates during the hands-on demonstration. A hands-on demonstration using multiple plutonium parts will likely be more applicable to personnel who handle plutonium on a daily basis, such as LANL glovebox operators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Nuclear Data Covariances on Integral Experiment Design with Sensitivity and Uncertainty Analysis

Washington River Protection Solutions (WRPS) uses MCNP6.2 and the Whisper code for criticality safety analyses of the Hanford Tank Farm. Together the codes derive baseline upper subcritical limits (USLs) for the waste models using experimental benchmarks. Whisper returns higher USLs, i.e. , has less of a conservative penalty, when the neutronic similarity of the experimental benchmarks to the application is high. Unfortunately, few critical benchmarks have high similarity to the Hanford tanks. The waste in the tanks is highly dilute in plutonium and contains large masses of weakly neutron-absorbing elements like iron and manganese. Experimental benchmarks typically have low sensitivity to these absorbers because they are present as structural materials. Lacking similar benchmarks, new Thermal Epithermal eXperiment (TEX) configurations with high Pu content and interstitial iron absorbers have been designed for the criticality safety validation. The features of the design have been iterated upon to maximize the similarity between the experiment and different Hanford waste models. The similarity is quantified with sensitivity analysis and uncertainty quantification using the representativity coefficient, or c k . The representativity calculation requires nuclear data covariances, which may differ between nuclear data libraries and between library versions. Because of these variations, the optimal design may depend on the nuclear data covariances library. A scenario can be envisioned where an experiment is designed, and c k is maximized, with one set of covariance data. However, when the covariance data is changed, say from ENDF/B-VII.1 to ENDF/B-VIII.0, and the benchmark is used in a criticality safety evaluation, the experiment becomes suboptimal with respect to c k . In this paper, we present how the optimal design of the new TEX experiments varied depending on the nuclear data covariances used to calculate c k . We compare ENDF/B-VII.1 and ENDF/B-VIII.0, as if the library had been updated since the design of the experiment. Additionally, we use JEFF3.3 to simulate if the covariance data of a different library had been used. The results show that the covariances do have an important effect on the designs, less so for thermal systems (where the data are more consistent between evaluations) and more so for epithermal systems where more differences exist.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity/Uncertainty Comparison Study Involving IRSN, LANL, and ORNL Tools to Support Validation

Under a DOE Nuclear Criticality Safety Program (NCSP) task involving Analytical Methods, three Laboratories collaborated in a comparison of results obtained from Sensitivity/Uncertainty (S/U) packages relevant to validation of transport codes. The task involves Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Oak Ridge National Laboratory (ORNL) comparing results of MORET 5/MACSENS V3.0, MCNP6.2/Whisper-1.1, and SCALE 6.2.3/TSUNAMI/USLSTATS respectively. All Monte Carlo transport code results utilize nuclear data from ENDF/B-VII.1 evaluation. This study examines five cases from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) selected as application models: IEU-MET- FAST-002-001, LEU-COMP-THERM-001-001, LEU-SOL-THERM-004-001, MIX-COMP- THERM-001-001, and U233-SOL-THERM-001-001. This is a continuation of a previous study to examine Pu and HEU cases: HEU-MET-FAST-013-001, HEU-SOL-THERM-001-008, PU-MET- FAST-022-001, and PU-SOL-THERM-001-001. Ultimately, comparison is made between Upper Subcritical Limits (USLs) obtained using each code package for each application case. Since differences exist in whether packages take into account margin of subcriticality (MOS), the USL is computed using only bias and bias uncertainty, also known as the calculational margin (CM) in ANSI/ANS-8.24. Results comparison appears to show that benchmark selection has a greater influence on the USL than the method used for calculation of bias and bias uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HEU Metal Delayed Critical Experiments with 10 to 19 Inch Thick Graphite Reflectors

Approximately 100 graphite-reflected highly enriched uranium (HEU, 93.14 wt % 235 U) metal annular and cylindrical critical experiments were performed in the early 1960s at the Oak Ridge Critical Experiments Facility (ORCEF). This report presents details from experiment logbooks, experimental data sheets and the author's memory for 44 HEU metal (93.14 wt % 235 U) critical assemblies with graphite reflectors varying from 10 to 19 in. thick, outside diameters varying from 7 to 15 in., inside diameters varying from 7 to 13 in. and critical HEU metal masses varying from 20.4 to 69.0 kg. The data from the 44 experiments described in this report are acceptable for use as criticality safety benchmark experiments for the International Criticality Safety Evaluation Program (ICSBEP) once the uncertainty analysis on the measured k eff is completed. Based on previous ICSBEP benchmarks with this HEU metal at ORCEF, the uncertainties in the measured k eff are expected to be as low as ±0.0004. Preparation of this report is part of an effort at Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented series of critical and subcritical experiments enumerated in Critical and Subcritical NEA Benchmark Possibilities for Measurements at ORCEF and Other US DOE Facilities (Mihalzo, ORNL/TM-2019/1188, 2019) and performed by ORNL at ORCEF and other US Department of Energy critical experiments facilities. More than 500 operational days of critical facility time were used, not including setup and dismantlement time. This documentation for a part of one series of graphite reflected highly enriched uranium metal critical experiments, that used 50 operational days of ORCEF time, was performed using funding received from the DOE Office of Nuclear Energy’s Nuclear Energy University Programs at the University of Tennessee Nuclear Engineering Department. This documentation was also supported by the Nuclear Criticality, Radiation Transport, and Safety programs at ORNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of a Density Law via Python for Aqueous Plutonium Nitrate

A predictive density tool has been developed in Python to reduce bias and uncertainty in nuclear criticality safety calculations for plutonium nitrate systems. The Pitzer Method and an empirical method were implemented into the tool, allowing for plutonium nitrate density calculations. Additionally, the Python tool can generate atom densities for a MCNP6.2 material card using the density from the selected method and directly the densities into a prepared MCNP6 input text file. The material card and density are calculated based on customizable user inputs of plutonium content, nitric acid content, temperature, plutonium isotope weight percentages and impurity concentrations. The Python tool has been validated and verified against the International Handbook of Evaluated Criticality Safety Benchmark Experiments to predict densities within a root mean square error of 1.0% for the Pitzer method and 1.8% for the empirical method. These errors in density were shown to lead to a ±0.5% error in MCNP6.2 calculated k effective for the Pitzer method and a ±1.7% error for the Empirical method. Simultaneous work is also being done at the University of New Mexico and Los Alamos National Laboratory to create a similar tool for plutonium chloride solutions, which aims to provide the accreditation of the chlorine absorption. These capabilities will not only provide more accurate models but also lead the way towards a better understanding of solution systems and potential relaxation in the conservatism of the current aqueous plutonium processing limits.

97 MATHEMATICS AND COMPUTING↗

Structural, Criticality, and Radiation Dose Calculations to support SNF Loading into a DOE Standard Canister

The DOE Standard Canister Demonstration Project includes the development of an internal support structure (ISS) for the 4.6-m long and 45.7-cm diameter canister. This study presents structural evaluations, criticality safety assessments, and dose rate calculations conducted within the scope of the ISS design process to support smooth canister loading operations and to ensure safe storage, transportation, and disposal of Peach Bottom 1 Core II (PB2) and Fort St. Vrain (FSV) SNF, currently stored at the CPP-603 facility of the INL. The ISS includes a 316L stainless steel basket that holds twelve PB2 SNF rods. Further, six individual, 78.7-cm long, 316L stainless steel columns are equally spaced and welded to the inner canister wall at the lower end of the shell. These columns represent the FSV basket and can hold one FSV SNF element. An A92014 T6 aluminum spacer disc is bolted to the bottom plate of the PB2 basket to vertically restrain the FSV SNF element after the PB2 basket is placed inside the canister on top of the FSV basket. The structural evaluations of the ISS followed applicable ASME BPVC.III.3 guidelines and included finite element (FE) analyses of the PB2 basket structure; analyses of welds and bolds; buckling analyses of selected components, and acceptability assessments of the expected basket deformations under loading operations. The criticality safety assessments used the Monte Carlo N-Particle (MCNP) software architecture version 6.2 including ENDF/B-V continuous energy cross-section libraries, considering intact SNF in a single storage overpack or two multi-storage overpack configurations, and intact or failed SNF configured for disposal. The dose rate computations are based on source terms taken from the DOE Spent Fuel Database. The isotopic composition was decay corrected for the year 2022 using the ORIGEN module in the SCALE suite. A 19-group photon spectrum and 27-group neutron-source spectra were generated and used in MCNP to calculate estimated dose-equivalent rates, both on DOE Standard Canister contact and at a radial distance of from the canister surface. The results of this study indicate a structurally sound system that can uphold its criticality safety functions throughout its intended operational phases. Further, they increase confidence that sufficient radiological protection is technically achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structural, Criticality, and Radiation Dose Calculations to Support SNF Loading into a DOE Standard Canister

The DOE Standard Canister Demonstration Project includes the development of an internal support structure (ISS) for the 4.6-m-long and 45.7-cm-diameter canister. This study presents structural evaluations, criticality safety assessments, and dose rate calculations conducted within the scope of the ISS design process to support smooth canister loading operations and to ensure safe storage, transportation, and disposal of Peach Bottom 1 Core II (PB2) and Fort St. Vrain (FSV) SNF, currently stored at INL’s CPP-603 facility. The ISS includes a 316L stainless-steel basket that holds 12 PB2 SNF rods. The PB2 basket rests on top of six individual, 78.7-cm-long, 316L stainless-steel columns that are equally spaced and welded to the inner canister wall at the lower end of the shell. These columns represent the FSV basket and can hold one FSV SNF element. An A92014 T6 aluminum spacer disc is bolted to the bottom plate of the PB2 basket to vertically restrain the FSV SNF element after the PB2 basket is placed inside the canister above the FSV basket. The structural evaluations of the ISS followed applicable ASME BPVC.III.3 guidelines and included finite element (FE) analyses of the PB2 basket structure; analyses of welds and bolds; buckling analyses of selected components, and acceptability assessments of the expected basket deformations under loading operations. The criticality safety assessments used the Monte Carlo N-Particle (MCNP) software architecture Version 6.2, including ENDF/B-V continuous-energy cross-section libraries, considering intact SNF in a single storage overpack or two multistorage overpack configurations and intact or failed SNF configured for disposal. The dose rate computations are based on source terms taken from the DOE Spent Fuel Database. The isotopic composition was decay corrected for the year 2022 using the ORIGEN module in the SCALE suite. A 19-group photon spectrum and a 27-group neutron-source spectrum were generated and used in MCNP to calculate estimated dose-equivalent rates, both on DOE Standard Canister contact and at a radial distance of 1 m from the canister surface. The results of this study indicate a structurally sound system that can uphold its criticality safety functions throughout its intended operational phases. Furthermore, this study provides confidence that sufficient radiological protection is technically achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CHALLENGES IN THE DEVELOPMENT OF THE ELECTROREFINING PROCESS AT Y-12

In order to ensure future capabilities of the Y-12 site as older buildings retire, a new process was developed, the Metal Purification Process. The purpose of this new process is to provide a simpler and more efficient uranium metal purification that the previous multi-staged, complex chemical processes. The basis for this technology currently exists in the US DOE complex, but it has not been utilized on a large scale for uranium at higher enrichments. The system requires larger-geometry vessels and furnaces in order to meet the through-put requirements. The crux of the process is the electrorefining cell, consisting of several concentric liners and an unfavorable geometry cylindrical crucible. Within the crucible, a molten Li-CL-KCL-UCL3 salt electrolyte is present. ‘Dirty’ metal is placed into a loading basket and loaded into an electrorefining cell. Here, the metal reacts into the molten salt within the cell to form UCL3, while ‘clean’ metal simultaneously plates out from the salt electrolyte in the form of metal dendrites. These dendrites are then collected and removed from the cell. After removal from the cell, the dendrites are taken to a furnace to remove adhered salts. Then, the salt-free dendrites are moved to a separate furnace for consolidation into the final product form. The development of the Criticality Safety Evaluation for this complex system brought with it many NCS Challenges and lessons learned. These challenges include: design decisions for ensuring subcriticalty in the electrorefining cell during abnormal conditions, the interface of the main glovebox system with auxiliary systems such as the purification system and designated storage, implementation of mass tracking, and concerns from production and operation regarding the movement of material within the system.

36 MATERIALS SCIENCE↗

Solubility Testing to Support the Addition of Sodium Reactor Experiment Material to Sludge Batch 10

The Savannah River Site H-Canyon Facility is planning to discard dissolved Sodium Reactor Experiment (SRE) material into Tank 51 prior to Sludge Batch 10 (SB10). SB10 with the SRE material will be processed in the Defense Waste Processing Facility (DWPF) using the Nitric-Glycolic Acid (NGA) flowsheet. The DWPF Nuclear Criticality Safety Evaluation (NCSE) protects a 14:1 mass ratio of manganese to equivalent uranium-235 in both the solid and liquid phases during processing by requiring a 70:1 mass ratio in the feed. A concern was raised that freshly precipitated manganese in the SRE material will behave differently from the manganese in sludge during DWPF processing and potentially invalidate the criticality control. To mitigate risks to the DWPF criticality controls, the Savannah River National Laboratory (SRNL) performed a metals solubility test applicable to recently precipitated manganese and uranium, as would be expected with SRE transfers to SB10. The objective of this analysis is the tracking of partitioning of the primary fissile component (uranium-235) with the credited poison (manganese) between the aqueous and insoluble phases.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lessons Learned From Ventilation and Glovebox Flooding Via Overfilling of the Wet Vacuum System in a Plutonium Facility

In the summer of 2021, operations personnel requested maintenance personnel to fill a wet vacuum (Wetvac) seal water tank in a plutonium facility at Los Alamos National Laboratory (LANL). After the filling was finished, the fill valve of the Wetvac seal water tank was left open and a ‘dead-man’ valve on an isolation line failed to close properly. After a series of other failures, the water exited the glovebox and contaminated three rooms of the first floor of the facility and an underlying area in the basement. A retrospective analysis of this event determined that there was no risk of a criticality due to the inherent design features of the ventilation system. This paper will explain the driving factors behind how this event was able to happen, as well as some of the major lessons learned that can be universally applied to other nuclear facilities. One of the main causes of the event was the delegation of work to maintenance personnel that were not qualified for the work being asked of them. Additionally, there was a lack of coordination between criticality safety engineers and facility operations equipment owners regarding equipment and connections present on the seal water tanks for the Wetvac, specifically the presence of overflow drain lines. The respective criticality safety evaluation credited an overflow drain line being present on the seal water tanks that was later found to have not been present. Lastly, there are lessons to be learned regarding equipment configuration and designing systems with safety in mind.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗