Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Real time computations of cryogenic He properties

The Fermilab PIP-II (proton improvement plan - II) project is being constructed at Fermilab to deliver $800\,MeV$ protons of $>1\,MW$ beam power to replace the present LINAC and provide protons to the remainder of the existing accelerator complex. The new LINAC consists of a warm front end, 23 superconducting RF cryomodules, and a beam transfer line to the existing complex. The cryomodules (CMs) are to be tested at Fermilab's CryoModule Test Facility (CMTF).An important measurement in cryogenic testing is the heat load of each CM. Traditionally, at Fermilab, these measurements were made collecting archived data offline and analyzing it. The new control system for PIP-II is being developed with the EPICS (Experimental Physics and Industrial Control System) framework, which allows us to compute the heat load in real time using the HePak library.We are exploring other $He$ properties, such as flow, where flow meters are not available, which can also be calculated in real time and fed back to the cryogenics engineers.This paper details the real time heat load calculation and $He$ flow software developed for CM testing at CMTF, as well as the first results from the prototype HB650 CM. Future plans for 2-phase $LHe$ flow will also be outlined.

Hanlet, Pierrick [Fermilab]↗

Calibration and Performance of Germanium High Voltage Detectors for SuperCDMS SNOLAB

As SuperCDMS SNOLAB is getting ready to search for low mass dark matter particles, using cryogenic Ge and Si detectors, a set of six of the new SuperCDMS High Voltage (HV) detectors (four Ge and two Si) were tested in the Cryogenic Underground TEst facility (CUTE) at SNOLAB. This provided the first opportunity to gain experience with this new detector type and assess their performance thoroughly under low background conditions. Here we describe the SuperCDMS HV detector concept and discuss some of the newly developed analysis methods and approaches. Focusing on the Ge detectors, we investigate the detector performance under voltage bias (up to 90 V), exercise the low energy (keV to sub-keV range) calibration based on the electron capture peaks generated by the decay of $^{71}$Ge, assess the detector resolution, and demonstrate the unexpected (and encouraging) ability of these detectors to also measure high energy interactions in the hundreds of keV range with good resolution (better than 3% at 356 keV).

Albakry, M. F. [British Columbia U.; TRIUMF]↗

Operational Experience of the NML Cryogenic Plant at the FAST Test Facility

The New Muon Laboratory (NML) cools two individually cryostated superconducting radio frequency (SRF) capture cavities (CC) and one prototype ILC cryomodule (CM) with eight SRF cavities. This complex accelerates electrons at 150 MeV for the Integrable Optics Test Accelerator (IOTA) ring, located at the Fermilab Accelerator Science and Technology (FAST) facility. Since 2019, this R&D accelerator complex has gone through four science runs.

Wallace, T. [Fermilab]↗

Co-Sputtering of Nb3Sn into SRF Cavity Using Composite Target and Optimizing Surface Homogeneity

Nb₃Sn coating method for superconducting radiofrequency (SRF) cavity has been developed following co-sputtering of Nb-Sn composite target using a DC cylindrical sputter coater. Deposition parameters and annealing strategies were optimized for uniform Nb₃Sn coating. 1.5 m Nb-Sn film was deposited onto 2.6 GHz Nb SRF cavity and annealed at 600 C for 6 h, followed by 950 C for 1 h. Cryogenic RF testing confirmed Nb₃Sn formation with Tc = 17.8 K. A post-annealing light Sn recoating process improved the cavity s performance, achieving Q₀ = 8.5 10⁸ at 2.0 K.

Shakel, M. S. [Old Dominion U.]↗

Nb3Sn Superconducting Radiofrequency Cavity Fabricated by Sputter Deposition from a Stoichiometric Target

Nb$_3$Sn is a promising coating material for superconducting radiofrequency cavities in next-generation accelerators due to its higher superconducting transition temperature (~18.3 K) and superheating field (~400 mT), offering the potential to surpass the intrinsic performance limits of bulk niobium. We developed a sputter coating technique employing a stoichiometric target to fabricate Nb$_3$Sn films on the inner surfaces of niobium cavities. A Nb$_3$Sn tube target, prepared by growing a >20 m thick Nb$_3$Sn coating on the surface of a Nb tube via a Sn vapor diffusion process, was used in a DC cylindrical magnetron sputtering system. Approximately 170 nm thick Nb-Sn films were sputter-coated onto flat Nb substrates positioned to replicate the beam tube and equator regions of a 2.6 GHz cavity, followed by annealing at 950 °C for 3 hours to form Nb$_3$Sn. The composition, morphology, and structure of the annealed Nb$_3$Sn films were examined. Then, a ~1.2 m-thick film was sputter-coated onto the interior of a 2.6 GHz Nb cavity following the procedure developed for the flat samples. The cavity was subsequently annealed under the same conditions used for the flat samples. Cryogenic RF testing of the sputter-coated cavity demonstrated a T$_c$ of approximately 17.8 K, consistent with Nb$_3$Sn layer. Subsequently, the cavity underwent a light Sn recoating followed by a vapor diffusion Nb$_3$Sn coating process, achieving a quality factor of approximately 8.5 × 10$^9$ and an accelerating gradient of up to 11.3 MV/m at 4.2 K.

Shakel, Md Sharifuzzaman [Old Dominion U.; Jeffers↗

Monitoring Helium Cryogen Usage with iFix Software at IB1 Test Facility

At the IB1 facility of the Applied Physics and Superconducting Technology Directorate within the Cryogenic Division at Fermilab, liquid helium is essential to the testing activities. The test stands used require large amounts of Helium to test the thermal and superconducting cavities and magnets. The liquid helium that enters the test stand is monitored through a series of valves and controls to determine the start and stop for monitoring time. There are 3 phases of cryogen usage that must be considered for each stand, cooldown, warming and overnight mode. With a new system in place, cold hour tracking will be more objective and precise within each test stand ensuring better calculations for user s fees that will provide funding for the replenishment of helium and continual operation at IB1.

Trillo, Angelica↗

Monitoring Helium Cryogen Usage with iFix Software at IB1 Test Facility

At the IB1 facility of the Applied Physics and Superconducting Technology Directorate within the Cryogenic Division at Fermilab, Liquid Helium is essential to the testing activities. The test stands require large amounts of Helium to test the thermal and superconducting cavities and magnets. The Liquid Helium that enters the test stand is monitored through a series of valves and controls to determine the start and stop for monitoring time. There are 3 phases of cryogen usage that must be considered for each stand, cooldown, warming and overnight mode. With a new system in place, cold hour tracking will be more objective and precise within each test stand ensuring better calculations for User s fees which are charged to various groups that employ the facility and aid replenishment of Helium and continual operation at IB1.

Trillo, Angelica↗

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB 650 CM.

Yoon, S. [Fermilab]↗

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign, an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real-time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB650 CM.

Yoon, S. [Fermilab]↗

Testing of Fusion Machine Components Against Cryogenic Pellet Impacts

Shattered pellet injection (SPI), currently the most effective method of disruption mitigation, is currently implemented on tokamaks worldwide for experimental purposes. Cryogenic pellets are formed and fired into an angled surface before entering the plasma. The impact with the angled surface causes the pellets to fragment into a cloud of particles with the purpose of increasing the surface area for ablation. As pellets traverse guide tubes, depending on design, there is a chance of an off-normal pellet impact. Pellet impacts are also, depending on design, possible in the plasma chamber if not fully ablated and assimilated, or if the fragment plume is not directed in the proper direction. This paper outlines a series of pellet impact tests on various tiles and components relevant to the ITER, JET, and ASDEX Upgrade SPI systems. In conclusion, testing was done to assess the potential damage from pellet and fragment plume impacts through high-speed imaging and the visual inspection of components.

Cryogenic pellets↗

A tunable dielectric resonator for axion searches at 11 GHz

In the context of axion search with haloscopes, tunable cavity resonators with high quality factor and high effective volume at frequencies above about 8 GHz are central for probing the axion-photon coupling with the required sensitivity to reach the QCD axion models. Higher order modes in dielectrically-loaded cavities allow for higher effective volumes and larger quality factors compared to basic cylindrical cavities, but a proper cavity frequency tuning mechanism to probe broad axion mass ranges is yet not available. In this work, we report about the design and construction of a tunable prototype of a single-shell dielectric resonator with its axion-sensitive pseudo-TM$_{030}$ high-order mode at about 11 GHz frequency. A clamshell tuning method previously tested for empty cylindrical resonators has been perfected for this geometry through simulations and in situ tests conducted at cryogenic temperature. Tuning is accomplished in a range of about 2 $\%$ the central frequency, without significantly impacting the quality factor of about 175000. The experimental results presented in this work demonstrate the tunability of this type of resonator, definitely confirming its applicability to high frequency axion searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Guarded Hot Cylinder Apparatus for Characterization of Thermal Insulation Systems and Materials at Liquid Hydrogen Temperatures

As interest in liquid hydrogen (LH2) continues to grow within the energy and mobility sectors, so does the demand for testing capabilities at deep cryogenics temperatures. However, cost-, complexity-, and safety-related challenges associated with handling LH2 effectively limit the landscape of possible options. As an alternative, LH2 temperatures can be accessed via a helium-based cryogenic refrigerator, or “cryocooler”. Recently, NASA and its partners CB&I and Shell began the development of a cryocooler-based calorimeter to characterize the thermal performance of insulations and other materials down to 20 K. Deemed the Guarded Hot Cylinder (GHC), the apparatus utilizes a small vacuum chamber in conjunction with a GM cryocooler and trim heater to control the cold boundary temperature. A sealed, cylindrical copper cup bolts to the cryocooler and houses the material specimen, with an internal, cylindrical test heater assembly to maintain the warm boundary. The steady-state heat load, traveling radially through the specimen, is measured via the electrical input power to the test heater and then used to evaluate the material’s absolute thermal performance. Initial checkout and validation of the GHC using a common bulk-fill insulation material showed close agreement with published data from standardized LN2 boiloff calorimetry testing. The instrument is now considered a lab standard, with the goal of incorporating it into the ASTM C1774 standard in the future, and it is in continuous use, examining insulation materials for next-generation LH2 applications.

Swanger, Adam (ORCID:000000021487592X)↗

Experiment to Investigate the On-set of Transient Fission Gas Release Under Simulated LOCA Conditions

Continuing efforts to better understand the phenomenon of transient fission gas release in irradiated commercial light water reactor fuel undergoing a simulated loss of coolant accident (LOCA) will be discussed in this work. During heating associated with LOCA conditions there is an additional release of fission gas beyond what is typically released during steady state operation. The exact timing of this release could impact the cladding balloon and rupture as the LOCA progresses in an actual accident. Recent experiments performed on the upgraded Severe Accident Test Station at Oak Ridge National Laboratory have expanded the current assessment of transient fission gas release. This system evaluates fission gas release by sweeping fission gas out of the LOCA test furnace and into cryogenically cooled cold traps where radioactive noble gas fission products are measured by gamma spectrometry. Additionally, the sweep gas can be monitored by a gas mass spectrometer to provide additional data on noble gas release and changes in the sweep gas atmosphere during heating. Several different conditions have been evaluated that explored the response of irradiated fuel to different thermal ramp conditions and different overpressure conditions. This further confirmed the impact of an overpressure in suppressing transient fission gas release. Further experiments are planned to evaluate the on-set temperature of transient fission gas release under a known overpressure. This test will progressively step through different temperature conditions while maintaining hydrostatic pressure on the fuel that is representative of high burnup fuel conditions. The available results from this type of testing will be discussed. Post-test microscopy will be compared to other transient fission gas release and standard LOCA tests to further understand the microstructural source of transient fission gas release.

Harp, Jason [ORNL] (ORCID:0000000253458440)↗

Quality and Loss Factor Analysis of YBCO Superconducting Transmission Lines for Axion Dark Matter Detection

Axion haloscope experiments aim to detect the conversion of axions into microwave photons in a magnetic field, which produces extremely small signals requiring low-loss cryogenic transmission lines for readout to reduce noise and attenuation. Yttrium Barium Copper Oxide (YBCO) cables are a promising candidate. Unlike commonly used low-loss superconducting cables such as Niobium (Nb) and Niobium Titanium (NbTi), which have low critical fields, YBCO is a high-temperature superconductor that can remain stable in strong magnetic fields. We evaluate their suitability by characterizing the quality and loss factors of five stripline resonators (three YBCO, and copper and silver references) from the Brookhaven Technology Group at 77 K without an external field, and cooled to 30 mK in a 14 T magnet. For measurements at 77 K we recorded scattering parameter data and employed Lorentzian and circle-fitting analysis techniques. We identified the best-performing resonator and developed a cryogenic probe for future testing in the magnet at millikelvin temperatures.

Marinos, Zoe [UCLA]↗

Challenges in Continuous In-Field Critical Current Testing of High-Temperature Superconducting Tapes: Thermal and Mechanical Perspectives

High-temperature superconductors (HTS) are essential for ultra-high-field applications requiring exceptional current-carrying capacity under extreme conditions. However, systematic characterization of critical current in long-length conductors remains challenging due to complex thermal, electromag netic, and mechanical interactions during continuous testing. This study reports the development of a continuous in-field magnetization testing system for position-dependent critical current measurement in HTS tapes at 20 K under 7.5 T fields applied normal to the tape plane, enabling identification of performance-limiting regions that could compromise magnet stability. Here, the system addresses two fundamental challenges inherent to cryogenic reel to-reel testing. First, thermal management requires continuous cooling of a moving conductor to 20 K, achieved through liquid nitrogen precooling combined with a 100 W@20 K Gifford McMahon cryocooler. Second, screening currents in high fields generate Lorentz forces that induce twisting, bowing, and potential delamination. To mitigate these risks, we propose mechanical reinforcement and active current density suppression strategies. Numerical simulations using the stream function formulation reveal four primary failure modes: frictional heating at guide interfaces, unstable equilibria causing deformation, transverse current-induced stresses at guide transitions, and unsupported forces in vertical spans. Our mitigation strategies include PTFE coated guides to minimize friction, spring-loaded stabilization mechanisms to maintain tape alignment, controlled pre-heating using the liquid nitrogen thermal jacket to suppress critical current at stress points, and optimized guide positioning to minimize force accumulation. The experimental system is nearing completion, with testing planned to commence within two months. Preliminary validation at 65 K under 0.5 T demonstrates strong correlation between simulation-predicted mechanical instabilities and observed critical current variations during conductor tran sitions through the measurement region. These findings establish a robust foundation for quality assurance protocols essential to next-generation superconducting magnet applications.

Chen, Siwei [Princeton Plasma Physics Laboratory (↗

Photon Detection System Calibration for DUNE

Photon Detection System Calibration for DUNE Not scheduled 20m Conference Center (University of California, Irvine) Poster New Technologies for Neutrino Physics Poster session Speaker Denis Torres (South Dakota School of Mines and Technology) Description The Deep Underground Neutrino Experiment (DUNE) is a long baseline neutrino oscillation experiment that relies on a precise Photon Detection System (PDS) to provide accurate timing information, enhance sensitivity to low-energy and non-beam events, and support detector performance studies in liquid argon time projection chambers. Achieving these goals requires a well-understood and stable optical calibration strategy that operates reliably under cryogenic conditions. In this poster, I will present PDS calibration studies performed in ProtoDUNE, focusing on the characterization of the ultraviolet (UV) light calibration system and key optical components in the light-delivery chain. I will discuss measurements of optical fiber transmission, SMA-to-SMA connector and feedthrough interface losses, and diffuser assemblies, emphasizing wavelength dependence, attenuation, and performance under cryogenic thermal cycling and stability tests. These studies provide quantitative inputs for understanding light transport, uniformity, and long-term reliability of the PDS in large-scale liquid argon detectors, and they directly inform calibration strategies for the DUNE Far Detector.

Torres Muñoz, Denis [South Dakota Sch. Mines Tech.↗

ExINP NSA Ice Nucleating Particle Concentrations

This data set comprises cumulative ambient ice-nucleating particle (INP) concentrations measured at the National Oceanic and Atmospheric Administration's (NOAA’s) Barrow Atmospheric Baseline Observatory (71.3230° N, 156.6114° W, “BRW” hereafter), next to the Atmospheric Radiation Measurement (ARM) North Slope of Alaska (NSA) site and ~ 6 km northeast of the town of Utqiaġvik. Our INP abundance data were generated using a combination of online instrument, the Portable Ice Nucleation Experiment chamber ver. 3 (PINE-03), and an offline cold stage, the West Texas Cryogenic Refrigerator Applied to Freezing Test system (WT-CRAFT). Our online INP data are all from the Examining the Ice-Nucleating Particles from NSA (ExINP-NSA) campaign conducted from October 19, 2021 to May 24, 2024. The offline INP concentration analysis was performed at West Texas A&M University for aerosol particle samples collected on polycarbonate filters (with 0.2-micron diameter pores). The PINE-03 measurements, as well as sampling activities for offline INP measurements, were conducted using the BRW site. An inset laminar sampling stack was mounted to the instrument platform, allowing PINE-03 to intake particle-laden air. For most of the campaign period, the semi-autonomous PINE-03 chamber was remotely controlled from West Texas A&M University using the LabView interface through the BeyondTrust remote-access console. PINE-03 was set to conduct an immersion freezing expansion experiment (i.e., simulated adiabatic cooling along with RHw at or above 100%). Except during the scheduled maintenance periods, the time resolution of each expansion experiment was approximately 12 minutes. PINE-03 continuously measured INP concentrations during the entire campaign without any substantial breaks. For most of the campaign period, PINE scanned its set-point vessel air temperatures from -14 °C to -31 °C and back to -14 °C about every 120 minutes.

54 ENVIRONMENTAL SCIENCES↗