Advanced Computing Annual Report 2022

National Renewable Energy Laboratory's (NREL) high-performance computing (HPC), efficient data center operation, and state-of-the-art data visualization powered over 300 clean energy projects in Fiscal Year 2022 (FY22). 555 scientists and engineers utilized HPC resources to assess and integrate data into their research. The report highlights the arrival of new HPC Kestrel in 2023, the contributions of the Insight Center, and researchers looking into bias in artificial intelligence, alongside key research collaborations using advanced computing.

advanced computing↗

INTREPID program: technology and architecture for next-generation, energy-efficient, hyper-scale data centers [Invited]

The INTREPID program is developing power-efficient coherent optics for package-level integration with future switch integrated circuits as a path to realizing higher-radix switches for flatter networks. The link architecture is underpinned by coherent quadrature phase-shift keying (QPSK) polarization-multiplex transceivers at 200 Gb/s per λ <#comment/> , further enhanced with wavelength division multiplexing (WDM) to enable energy-efficient 800 or 1600 Gb/s inter-switch fiber connections. The technology is compatible with conventional three-level data center designs as well as a two-level data center design introduced here, which includes an added layer of passive, arrayed waveguide grating routers (AWGRs) or WDM circuit switches to further improve the cost, energy efficiency, and latency of the network.

Saleh, Adel A. M. (ORCID:0000000182451136)↗

Data Center Facility Monitoring with Physics Aware Approach

U.S. Department of Energy's National Renewable Energy Laboratory (NREL) hosts one of the world's most energy-efficient HPC data centers; this system uses component-level warm-water liquid cooling to efficiently remove heat from the data center and capture it for reuse in the building or rejection to the atmosphere. Given the complexity of this system, building data-driven tools for holistically monitoring and operating the entire data center is a priority for ensuring maximal efficiency and resiliency. In this advanced smart facility, over one million metrics are recorded per minute using state-of-the-art streaming data architecture and software to capture and process the state of the system in real time. Here we detail two efforts to effectively analyze, visualize, and interpret this large volume streaming data. We have developed a novel, flexible system for identifying and visualizing individual metric anomalies and component performance across the data center through automatic metadata extraction and physically-motivated visualization for quick interpretation. Additionally, to directly connect system maintenance to data stream processing we explore a physics informed multi-metric drift and anomaly detection application to detect scale-build up in heat exchangers.

anomaly detection↗

Artificial Intelligence for Data Center Operations (AIOps): Cooperative Research and Development (Final Report)

High performance computing data centers will increasingly need to rely on automation to keep pace with exascale growth in compute capability and to manage and optimize the data center environment and facility resources. Artificial intelligence and machine learning approaches provide the means to improve HPC data center operational efficiency, by learning historical trends and training models to operate on real-time data collected from both IT and facilities sources. NREL has developed methods of real-time collection, aggregation and streaming of these data in the ESIF HPC Data Center and has collected a significant dataset of relevant metrics across computer systems, racks, environmental, building and utility sources for research into various predictive analytics problems. HPE's Advanced Technology Group (ATG) is doing comprehensive research into exascale monitoring and management for High Performance Computing (HPC) systems (hereinafter HPE's Data Monitoring/ Management Technology). NREL and HPE will collaborate to add Artificial Intelligence (AI) to NREL's real-time data collection/ aggregation/ streaming system and HPE's Data Monitoring/ Management System, with the goal of improving the operational efficiency of NREL's Energy Systems Integration Facility (ESIF) HPC Data Center through data analytics on both historical and real-time data from IT systems and facilities operations. This collaboration will consist of efforts in Data Management, Data Analytics, and AI/ML Optimization for both manual and autonomous intervention in data center operations. This will be a multi-year, multi-staged effort with a goal towards building capabilities for an Advanced Smart Facility, and demonstration of these techniques in the NREL ESIF HPC Data Center.

97 MATHEMATICS AND COMPUTING↗

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optics Enabled Networks and Architectures for Data Center Cost and Power Efficiency

Bandwidth demand for datacenter networks continues as performance increases and is further fueled by the exploding demand for AI and new HPC workloads. Managing power and costs will require a range of solutions including new networking and workload specialized architectures, composable systems and optical circuit switching. In this study we focus primarily on two topics, examining the benefits of flatter networks (enabled mainly by means of co-packaged-optics-enabled switches) and the utilization improvement potential for composable (disaggregated) systems, while discussing specialized hardware and networks, and optical circuit switching more briefly.

99 GENERAL AND MISCELLANEOUS↗

Extreme Efficiency 240 Vac to Load Data Center Power Delivery Topologies and Control

The research explored innovative new circuit topologies and power converter architectures for data center power delivery, from the 240 V ac voltage at the input of a server rack, down to the less than 1 V dc power supply of the latest microprocessors. The research pursued three parallel tracks to increase the power conversion efficiency and to reduce the overall size of the servers: 1) An innovative new ac-dc power converter topology which enables improved efficiency through use of a novel direct step-down topology, well suited for the popular 48V dc power distribution. 2) A new series-stacked power delivery approach for servers comprising a large number of similar loads, such as hard drives in storage servers. The approach greatly reduces the power conversion losses, and achieves efficiency well over 99%. 3) A new family of hybrid switched-capacitor power converters that enable improved efficiency and reduced size through the use of dense ceramic capacitors and new circuit topologies that leverage GaN and low-voltage Si transistor technology. Together, the accomplished research achieved the goal of reducing the power conversion losses in datacenters, thereby reducing greenhouse gas emissions, operating costs, and overall electricity consumption.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-resonant switched capacitor power converter architecture

A switched-capacitor (SC) network in an SC converter is controlled to operate at varying resonant modes to achieve high conversion ratio efficiency, at a low circuit component count. These power converters are suited to numerous application areas including improving energy efficiency of data centers. A family of resonant switched capacitor (SC) converters with multiple operating phases are presented “Multi-Resonant SC Converters”. Described in detail are an 8-to-1 Multi-Resonant-Doubler (MRD) converter and a 6-to-1 Cascaded Series-Parallel (CaSP). The topology of these converters make them amenable to combining like units in parallel toward reaching higher power levels.

Ye, Zichao↗

Shedding light on U.S. small and midsize data centers: Exploring insights from the CBECS survey

As demand for digital services accelerates, the energy and environmental footprint of data centers faces increasing scrutiny. While hyperscale cloud facilities have driven efficiency gains, small and midsize U.S. data centers remain a critical yet underexamined segment with significant untapped potential for energy savings. This study leverages data from the Commercial Buildings Energy Consumption Survey (CBECS) to analyze trends in server stocks, computing customers, cooling system adoption and efficiency, and geospatial distribution from 2012 to 2018. Findings reveal a sharp decline in small and midsize data centers, from 1.764 million to 1.398 million, with server counts dropping from 5.177 million to 4.262 million—aligning with the broader shift toward cloud computing. More than 40 % of servers in small data centers and 55 % in midsize data centers are housed in office buildings, and over half of all servers are concentrated in climate zones 5A (cold), 3A (mixed-humid), and 4A (mixed-humid), with the highest densities in metropolitan hubs. While direct expansion units remain the dominant cooling system, a clear transition toward more energy-efficient solutions, particularly air economizers, is evident. By integrating server and cooling system distributions, we estimate Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) for U.S. data centers by size and year. Results show that midsize data centers are more energy-efficient but more water-intensive due to the widespread use of water-cooled chillers. These findings highlight the trade-offs in cooling system selection and provide a critical foundation for policies aimed at enhancing efficiency in an evolving data center landscape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conceptual Cost Estimating

Kennedy Space Center data aid in efficient construction-cost managment. Report discusses development and use of NASA TR-1508, Kennedy Space Center Aerospace Construction price book for preparing conceptual budget, funding cost estimating, and preliminary cost engineering reports. Report based on actual bid prices and Government estimates.

Brown, J. A.↗

Bridging the Gap for Powering Data Centers

The rapid expansion of data centers, primarily driven by artificial intelligence, is outpacing the adaptability of the U.S. electric grid. This report, developed by Idaho National Laboratory (INL) , presents a gap analysis of some of the infrastructure challenges associated with large-scale data center deployment. Drawing from a national workshop hosted by INL in October of 2025, the report synthesizes stakeholder insights, survey data, and technical discussions to identify critical barriers and research needs. Key findings highlight the growing preference for behind-the-meter generation, the perceived inadequacy of legacy interconnection processes, and the urgent need for improved coordination between utilities, regulators, and data center developers. Environmental concerns such as water use and noise pollution, as well as economic constraints like equipment lead times and cost allocation, are also explored. The report outlines national lab capabilities in modeling, simulation, and technical assistance, and proposes targeted R&D priorities to support resilient, scalable, and efficient integration of data centers into the grid.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Digital Twins for Data Centers

Fueled by an unprecedented adoption of AI (Artificial Intelligence), data centers are becoming the largest growing consumers of energy. Digital Twins provide living digital models of physical systems that enable data-driven analysis and application of AI to better manage selective aspects of the data center and drive efficiency for sustainability. Digital twins have emerged as a way to create virtual prototypes of physical artifacts, which may be used in a variety of contexts. Physical artifacts include airplanes, factories, or even static objects, such as bridges or dams. Digital twin helps monitor changes and assist in predicting planned or unplanned behaviors of physical objects. In this paper, we discuss digital twins for data centers.

97 MATHEMATICS AND COMPUTING↗

Green Computing Catalyzer Kickoff: Green Artificial Intelligence (AI) Directions

For the 2022 JISEA annual meeting, JISEA introduces in this presentation the new Green Computing Catalyzer. The new catalyzer looks to establish green computing as a salient research domain at NREL, and crucially, to begin to address the looming computing energy crisis. The presentation provides some basic numbers, establishing energy use and source or carbon emissions for computing. The presentation also includes a brief history of green computing at NREL, empirical deep learning efficiency study, and research directions.

AI efficiency↗