Search NASA⌕ Search

SEARCH · Search NASA

Results for “data lakes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Analysis of Skylab MSS data, and calibration of thermal data over Lake Monroe, Indiana

The author has identified the following significant results. The SL/4-S192 data over northern Indiana looks good. The thermal band looks very encouraging. The preliminary analysis indicates so far that it will be difficult to distinguish some land use classes because of the lack of vegetation. Preliminary analysis of the thermal band in particular indicates that there appears to be a correlation of the hot spots in the data over the Ft. Wayne, Indiana area and its industrial centers.

Silva, L. F.↗

Utilization of satellite data for inventorying prairie ponds and lakes. LANDSAT-1 data were used to discriminate ponds and lakes for waterfowl management

The author has identified the following significant results. The mapping of open water as an indicator of waterfowl habitat quality was carried out by using two different recognition techniques, a single waveband thresholding approach and a multiple waveband approach termed proportion estimation. The single waveband technique has proven simple to implement. Its computer algorithm was rapid and accurately recognized prairie lakes and large ponds. The resultant products of this processing technique were thematic maps and statistical tabulations describing open surface water conditions. The maps served to portray visually the location and frequency of surface water bodies but usually necessitated additional interpretation.

Gilmer, D. S.↗

WHOLESCALE: Seismic Survey Data from San Emidio Nevada 2021

This dataset includes raw and processed seismic data from the 2021 seismic survey at the San Emidio geothermal field in Nevada. In April and May 2021, 37 tri-axial short period seismographs were deployed in a 1.8km diameter cluster centered on 40.367278 N, 119.409019 W. The first data record started at 2021-04-06T07:09:10Z UTC and the last record ended at 2021-05-11T02:58:52Z UTC. The 37 stations included 29 SmartSolo IGU-16HR 3C all-in-one 5 Hz seismographs and 8 DataCube seismographs with 4.5 Hz HGS HG-6(B coil) tri-axial geophones. The raw format (level 0) data includes 353 GB of 500 sps SmartSolo data in native DLD format, 113 GB of 400 sps DataCube data in native DataCube format, and 3.4 GB of GPS data collected during the RTK GPS survey. The SAC data (level 1) files include 564 GB of hourly SAC files. The experiment was designed to monitor seismic activity before, during, and after the planned three-day plant maintenance shutdown April 19-21, 2021. The pumping stopped at 2021/04/19 12:51:45 UTC and resumed about 2021/04/21 21:00:00 UTC. The dataset is hosted in an AWS data lake, with an associated GDR data set providing the metadata. Links to both of these resources are included below. Additionally, this collection features data and metadata from a 2016 seismic survey at the same site for comparative analysis.

15 GEOTHERMAL ENERGY↗

A Lakehouse Architecture for the Management and Analysis of Heterogeneous Data for Biomedical Research and Mega-biobanks

Data Lakehouse is a new paradigm in data architectures that embodies and integrates already established concepts for the systematic management of disparate, large-scale data – a data lake for heterogeneous data management, use of open standards for high-performance querying, and systematic maintenance of the data "freshness". In addition to being a new concept, the data lakehouse is also still a conceptual construct. Many projects that use the lakehouse require maturing, empirical studies, and specific implementations. In this paper, we present our implementation of the data lakehouse concept in a biomedical research and health data analytics domain, and we discuss the implementation of some unique and novel features such as support for specialized access controls in support of HIPAA regulation and IRB protocols, and support for the FAIR standard.

Begoli, Edmon↗

A study of Minnesota forests and lakes using data from earth resources technology satellites

This project is to foster and develop new applications of remote sensing under an interdisciplinary effort. Seven reports make up the specific projects presently being conducted throughout the State of Minnesota in cooperation with several agencies and municipalities. These are included under the general headings of: (1) applications of aerial photography and ERTS-1 data to agricultural, forest, and water resources management; (2) classification and dynamics of water and wetland resources of Minnesota; (3) studies of Lake Superior Bay; and (4) feasibility of detecting major air pollutants by earth-oriented satellite-borne sensors.

Source record↗

A study of Minnesota forests and lakes using data from Earth Resources Technology Satellites

Highlights of research and practical benefits are discussed for the following projects which utilized ERTS 1 data to provide municipal, state, federal, and industrial users with environmental resource information for the state of Minnesota: (1) forest disease detection and control; (2) evaluation of water quality by remote sensing techniques; (3) forest vegetation classification and management; (4) detection of saline soils in the Red River Valley; (5) snowmelt flood prediction; (6) remote sensing applications to hydrology; (7) Rice Creek watershed project; (8) water quality in Lake Superior and the Duluth Superior Harbor; and (9) determination of Lake Superior currents from turbidity patterns.

Source record↗

ComStock Measure Scenario Documentation: Chiller Replacement

Building on a 3-year effort to calibrate and validate the U.S. Department of Energy's ResStock (TM) and ComStock (TM) models, this work produces national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual energy consumption (at a subhourly resolution) of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. The goal of this work is to develop energy efficiency and demand flexibility end-use load shapes that cover high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to various "what-if" scenarios that can be applied to buildings. An end-use savings shape is the difference in energy consumption between a baseline building (or collection of buildings) and a building with an energy efficiency or demand flexibility measure applied. It results in a time-series profile broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step, as well as annual aggregations. This report describes the modeling methodology for a single end-use savings shape measure - chiller replacement - and briefly introduces key results. The full public dataset can be accessed on the ComStock (TM) data lake or via the Data Viewer at comstock.nrel.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: High-Efficiency Rooftop Unit

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - high-efficiency rooftop unit (RTU) - and briefly introduces key results. The full public data set can be accessed on the Comstock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Variable-Speed Pumps

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - variable speed pumps - and briefly introduces key results. The full public data set can be accessed on the ComStock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Fan Static Pressure Reset for Multizone Variable Air Volume Systems

This report assesses the potential for nationwide adoption of a duct static pressure reset in MZ VAV systems in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario—Fan Static Pressure Reset for Multizone Variable Air Volume (VAV) Systems—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Thermostat Setbacks During Unoccupied Periods

This report assesses the potential for nationwide adoption of thermostat setbacks in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario— Thermostat Setbacks During Unoccupied Periods—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use cases (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Cold Climate Air-Source Heat Pump

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Cold Climate Air-Source Heat Pump" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Light Air Sealing, Attic Floor Insulation, and Duct Sealing and Insulation

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Light Envelope" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.