Search NASA⌕ Search

SEARCH · Search NASA

Results for “decay photons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Multiple photon emission in heavy particle decays

Cosmic ray interactions, at energies above 1 TeV/nucleon, in emulsion chambers flown on high altitude balloons have yielded two events showing apparent decays of a heavy particle into one charged particle and four photons. The photons converted into electron pairs very close to the decay vertex. Attempts to explain this decay topology with known particle decays are presented. Unless both events represent a b yields u transition, which is statistically unlikely, then other known decay modes for charmed or bottom particles do not account satisfactorily for these observations. This could indicate, possibly, a new decay channel.

Asakimori, K.↗

Test of the decaying dark matter hypothesis using the Hopkins Ultraviolet Telescope

Sciama's hypothesis that the dark matter associated with galaxies, galaxy clusters, and the intergalactic medium consists of tau neutrinos of rest mass 28-30 eV whose decay generates ultraviolet photons of energy roughly 14-15 eV, has been tested using the Hopkins Ultraviolet Telescope flows aboard the Space Shuttle Columbia. A straightforward application of Sciama's model predicts that a spectral line from neutrino decay photons should be observed from the rich galaxy cluster Abell 665 with an SNR of about 30. No such emission was detected. For neutrinos in the mass range 27.2-32.1 eV, the observations set a lower lifetime limit significantly greater than Sciama's model requires.

Davidsen, A. F.↗

Transition probability of the Si III 189.2-nm intersystem line

Measurement of the lifetime of the metastable 3s3p(3)P(0)1 level of Si(2+) (Si III), which decays by photon emission at 189.2 nm to the 3s2(1)S0 state, is reported. The data were taken from spontaneous emission from metastable Si III stored in an RF ion trap. The Si III ions were produced through electron bombardment of SiH4 and SiF4 at pressures of 1/100,000,000-1/10,000,000 Torr. A photomultiplier was employed to count the photon emissions from the transitions. A total of 11 decay curves were generated for analysis, with Poisson statistics used to set the uncertainties at within 8 pct. Significant systematic effects were controlled, and the lifetime was found to be within 3.6 microsec of 59.9 microsec. The method used is concluded valid for determining the lifetimes of metastable levels of low-Z ions with low charge, and thereby the transition probabilities.

Kwong, H. S.↗

Observation of radiative surface plasmons in metal-oxide-metal tunnel junctions

A peak in the UV region of the spectrum of light emitted from metal-oxide-metal (MOM) tunnel junctions has been observed at room temperature. Both the amplitude and wavelength of the peak are sensitive to applied junction bias. The UV peak corresponds to the normal or radiative surface plasmon mode while a visible peak, also present in the present spectra and reported in past MOM literature, is due to the tangential or nonradiative mode. The radiative mode requires no surface roughness or gratings for photon coupling. The results show that it is possible to obtain radiative surface plasmon production followed by a direct decay into photons with MOM tunnel diodes. A MOM diode with a double anode structure is found to emit light associated only with the nonradiative mode. The thickness dependence of the UV peak, along with the experimental results of the double anode MOM diode and the ratio of the UV peak to visible peak, support the contention that the UV light emission is indeed due to the radiative surface plasmon.

Donohue, J. F.↗

Cosmological constraints on the lifetime of massive particles

Particles with masses more than a few MeV, decaying into photons or electrons, can cause destruction by photofission of cosmologically produced light elements. A previous calculation of this effect is corrected and extended, and used to derive maximum lifetimes for massive neutrinos; these range from a few thousand seconds upward, depending on the particle mass. Some approximate expressions are given that enable lifetime limits to be obtained for other particles, with different masses and abundances, such as gravitinos. These limits are generally stronger than previously determined constraints, such as distortion of the microwave background by energetic photons.

Lindley, D.↗

Distorted Wave Calculation and Applications

Physical properties such as temperature and electron density of solar plasma and other astrophysical objects can be inferred from EUV and X-ray emission lines observed from space. These lines are emitted when the higher states of an ion are excited by electron impact and then decay by photon emission. Excitation cross sections are required for the spectroscopic analyses of the observations and various approximations have been used to calculate the scattering functions. One of them which has been widely used is a distorted wave approximation. This approximation, along with its applications to solar observations, is discussed. The Bowen fluorescence mechanism and optical depth effects are also discussed. It is concluded that such calculations are reliable for highly charged ions and for high electron temperatures.

Bhatia, A. K.↗

Distorted Wave Calculations and Applications

Physical properties such as temperature and electron density of solar plasma and other astrophysical objects can be inferred from EUV and X-ray emission lines observed from space. These lines are emitted when the higher states of an ion are excited by electron impact and then decay by photon emission. Excitation cross sections are required for the spectroscopic analyses of the observations and various approximations have been used to calculate the scattering functions. One of them which has been widely used is a distorted wave approximation. This approximation, along with its applications to solar observations, is discussed. The Bowen fluorescence mechanism and optical depth effects are also discussed. It is concluded that such calculations are reliable for highly charged ions and for high electron temperatures.

Bhatia, A. K.↗

Telescope search for a 3-eV to 8-eV axion

Axions of mass 3-8 eV should have a cosmological abundance of about 50/cu cm and reside in rich clusters of galaxies. Their decays to two photons will produce a line at a wavelength of about 3100-8300 A. This effort has searched unsuccessfully for such a feature in the tergalactic light of three rich clusters, closing this 'window', and leaving open only the window from 10 to the -6th to 0.001 eV. This implies that if the axion exists, it likely comprises the dark matter. The present flux limits are of relevance to other relics whose decays produce monoenergetic photons.

Bershady, Matthew A.↗

Limits to the radiative decays of neutrinos and axions from gamma-ray observations of SN 1987A

Gamma-ray observations obtained by the SMM gamma-ray spectrometer in the energy range 4.1-6.4 MeV are used to provide limits on the possible radiative decay of neutrinos and axions emitted by SN 1987A. For branching ratio values for the radiative decay modes of less than about 0.0001, the present limits are more stringent than those based upon the photon flux from decaying relic neutrinos. The data are also used to set an axion mass limit.

Kolb, Edward W.↗

Anisotropic Optical-Response of Eu-doped Yttrium Orthosilicate

Eu-doped yttrium orthosilicate (Eu(3+) : Y2SiO5) had been a subject being investigated for coherent time-domain optical memory and information processing applications since its ultraslow optical dephasing was discovered several years ago. In this crystal the weakly allowed (7)F0 - (5)D0 transition of europium ions exhibits a sufficient long dephasing time and no spectral difli.usion on a time scale of several hours at low temperature, thus an information pattern or data can be stored as a population grating in the ground state hyperfine levels. On the other hand, the study on photon-echo relaxation shows that the dephasing time T2 of Eu (3+) and other rare-earth ions doped YAG, YAlO3 strongly depends on the intensity of the excitation pulses. In Eu (3+) :YAlO3, an exponential decay of photon-echo with T2 = 53 microseconds if the excitation pulses are weak (5 vJ/pulse) was observed. However, when the excitation pulses are strong (80 pJ/pulse) they observed a much shortened T2 with a highly nonexponential decay pattern. The conclusion they derived is that the intensity-dependent dephasing rate effects are quite general, and it depends on how much the excitation intensity varies. In this paper we use transient grating formation technique showing that a temporal lattice distortion may only occur along crystal c axis, caused by EU (3+) excitation. At high excitation level the produced exciton in conduction band may also couple to the dynamical lattice relaxation process, giving rise to an apparently much shortened dephasing time.

Liu, Huimin↗

Limits to the radiative decay of the axion

An axion with a mass greater than 1 eV should be detectable through its decay into two photons. The astrophysical and cosmological limits which define a small window of allowed axion mass above 3 eV are discussed. A firm upper bound to the axion's mass of M(sub a) less than or equal to 8 eV is derived by considering the effect of decaying axions upon the diffuse extragalactic background radiation and the brightness of the night sky due to axions in the halo of the Milky Way galaxy. The intergalactic light of clusters of galaxies is shown to be an ideal place to search for an emission line arising from the radiative decay of axions. An unsuccessful search for this emission line in three clusters of galaxies is then detailed. Limits to the presence of any intracluster line emission are derived with the result that axions with masses between 3 and 8 eV are excluded by the data, effectively closing this window of axion mass, unless a severe cancellation of axionic decay amplitudes occurs. The intracluster flux limits are then used to constrain the amplitude of any such model dependence.

Ressell, M. Ted↗

Experimental apparatus for measurements of electron impact excitation

An ion beam apparatus for the absolute measurement of collision cross sections in singly and multiply charged ions is described. An inclined electron and ion beams arrangement is used. Emitted photons from the decay of collision produced excited states are collected by a mirror and imaged onto a photomultiplier. Absolute measurements of the electron impact excitation of the 2s-2p transition in C(3+) were used to demonstrate the reliability of the apparatus.

Lafyatis, G. P.↗

Angular correlation studies in noble gases

There has been a recent revival of interest in the measurement of angular correlation of annihilation photons from the decay of positrons and positronium in gases. This revival has been stimulated by the possibility offered by the technique to shed new light on the apparently low positronium formation fraction in the heavier noble gases and to provide information on positronium quenching processes in gases such as oxygen. There is also the potential for learning about positronium slowing down in gases. This review focuses on experimental noble gas work and considers what new information has been, and may be, gained from these studies.

Coleman, P. G.↗

Methods of Fabricating Scintillators with Radioisotopes for Beta Battery Applications

Technology has been developed for a class of self-contained, long-duration power sources called beta batteries, which harvest the energy contained in the radioactive emissions from beta decay isotopes. The new battery is a significant improvement over the conventional phosphor/solar cell concept for converting this energy in three ways. First, the thin phosphor is replaced with a thick scintillator that is transparent to its own emissions. By using a scintillator sufficiently thick to completely stop all the beta particles, efficiency is greatly improved. Second, since the energy of the beta particles is absorbed in the scintillator, the semiconductor photodetector is shielded from radiation damage that presently limits the performance and lifetime of traditional phosphor converters. Finally, instead of a thin film of beta-emitting material, the isotopes are incorporated into the entire volume of the thick scintillator crystal allowing more activity to be included in the converter without self-absorption. There is no chemical difference between radioactive and stable strontium beta emitters such as Sr-90, so the beta emitter can be uniformly distributed throughout a strontium based scintillator crystal. When beta emitter material is applied as a foil or thin film to the surface of a solar cell or even to the surface of a scintillator, much of the radiation escapes due to the geometry, and some is absorbed within the layer itself, leading to inefficient harvesting of the energy. In contrast, if the emitting atoms are incorporated within the scintillator, the geometry allows for the capture and efficient conversion of the energy of particles emitted in any direction. Any gamma rays associated with secondary decays or Bremsstrahlung photons may also be absorbed within the scintillator, and converted to lower energy photons, which will in turn be captured by the photocell or photodiode. Some energy will be lost in this two-stage conversion process (high-energy particle to low-energy photons to electric current). The geometric advantage partially offsets this as well, since the absorption depth of high-energy beta radiation is much larger than the depth of a p-n junction. Thus, in a p-n junction device, much of the radiation is absorbed far away from the junction, and the electron- hole pairs are not all effectively collected. In contrast, with a transparent scintillator the radiation can be converted to light in a larger volume, and all of the light can be collected in the active region of the photodiode. Finally, the new device is more practical because it can be used at much higher power levels without unduly shortening its lifetime. While the crystal structure of scintillators is also subject to radiation damage, their performance is far more tolerant of defects than that of semiconductor junctions. This allows the scintillator- based approach to use both higher energy isotopes and larger quantities of the isotopes. It is projected that this technology has the potential to produce a radioisotope battery with up to twice the efficiency of presently used systems.

Rensing, Noa M.↗

Laboratory astrophysics under the ultraviolet, visible, and gravitational astrophysics research program: Oscillator strengths for ultraviolet atomic transitions

The conditions within astrophysical environments can be derived from observational data on atomic and molecular lines. For instance, the density and temperature of the gas are obtained from relative populations among energy levels. Information on populations comes about only when the correspondence between line strength and abundance is well determined. The conversion from line strength to abundance involves knowledge of meanlives and oscillator strengths. For many ultraviolet atomic transitions, unfortunately, the necessary data are either relatively imprecise or not available. Because of the need for more and better atomic oscillator strengths, our program was initiated. Through beam-foil spectroscopy, meanlives of ultraviolet atomic transitions are studied. In this technique, a nearly isotopically pure ion beam of the desired element is accelerated. The beam passes through a thin carbon foil (2 mg/cu cm), where neutralization, ionization, and excitation take place. The dominant process depends on the energy of the beam. Upon exiting the foil, the decay of excited states is monitored via single-photon-counting techniques. The resulting decay curve yields a meanlife. The oscillator strength is easily obtained from the meanlife when no other decay channels are presented. When other channels are present, additional measurements or theoretical calculations are performed in order to extract an oscillator strength. During the past year, three atomic systems have been studied experimentally and/or theoretically; they are Ar, I, Cl I, and N II. The results for the first two are important for studies of interstellar space, while the work on N II bears on processes occurring in planetary atmospheres.

Federman, Steven R.↗

Electron-photon coincidence technique for the absolute calibration of VUV detectors

A method is described whereby VUV photon detectors can be accurately calibrated. This method is illustrated by taking the 58.4-nm transition of He as an example. The technique consists of crossing a monoenergetic electron beam with a beam of He atoms. When inelastically scattered electrons which have excited the 2 1P state are detected in coincidence with the 58.4-nm photons emitted in the decay of the excited state, the interaction volume formed by the crossed beams constitutes a standard source of photons. By comparing the number of detected coincidences with the predicted number the calibration can be made. A total detector efficiency of 0.024 + or - 0.003 is obtained for a Galileo 4830 channeltron.

Mcadams, R.↗

Development of a Photon Counting System for Differential Lidar Signal Detection

Photon counting has been chosen as a means to extend the detection range of current airborne DIAL ozone measurements. Lidar backscattered return signals from the on and off-line lasers experience a significant exponential decay. To extract further data from the decaying ozone return signals, photon counting will be used to measure the low light levels, thus extending the detection range. In this application, photon counting will extend signal measurement where the analog return signal is too weak. The current analog measurement range is limited to approximately 25 kilometers from an aircraft flying at 12 kilometers. Photon counting will be able to exceed the current measurement range so as to follow the mid-latitude model of ozone density as a function of height. This report describes the development of a photon counting system. The initial development phase begins with detailed evaluation of individual photomultiplier tubes. The PMT qualities investigated are noise count rates, single electron response peaks, voltage versus gain values, saturation effects, and output signal linearity. These evaluations are followed by analysis of two distinctive tube base gating schemes. The next phase is to construct and operate a photon counting system in a laboratory environment. The laboratory counting simulations are used to determine optimum discriminator setpoints and to continue further evaluations of PMT properties. The final step in the photon counting system evaluation process is the compiling of photon counting measurements on the existing ozone DIAL laser system.

Elsayed-Ali, Hani↗