Search NASA⌕ Search

SEARCH · Search NASA

Results for “defect microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

In-Situ Transmission Electron Microscopy Study of the Evolution of Extended Defects in Oxide Nuclear Fuels

In-situ transmission electron microscopy (TEM) with simulated extreme environments is an effective tool for understanding and tracking microstructural changes down to the atomic scale. The objective of this research is to study the effect of temperature on the evolution of extended defects in ThO2 and UO2. Here, we present in-situ TEM isochronal thermal annealing experiments using a micro-electro-mechanical-system (MEMS)-based heating holder. ThO2 and UO2 single crystal specimens were grown inside an inert silver ampoule using hydrothermal synthesis. Both samples were irradiated using 2 MeV protons at 600oC up to 0.1 dpa at Texas A&M University’s Accelerator Laboratory. Fig. 1a shows a weak-beam dark field TEM image of ThO2 after irradiation, indicating the presence of faulted 1/3 <111> type dislocation loops. This presentation will discuss the effect of annealing temperature (600oC, 800oC, 1000oC, 1100oC, etc.) on dislocation loop density, size and distribution, loop nature (interstitial/vacancies) and Burgers vector, as well as the formation of voids in both ThO2 and UO2. This work will also discuss the interaction between defects during annealing. The in-situ TEM annealing cycle is shown in Fig 1b. This research significantly improves the understanding of defect behavior in oxide nuclear fuels with temperature and will aid computational modeling efforts. This work was supported as part of the Center for Thermal Energy Transport under Irradiation (TETI) Energy Frontier Research Center, funded by the U.S. Department of Energy Office of Science.

36 MATERIALS SCIENCE↗

Nanoscale lattice strains in self-ion implanted tungsten

Developing a comprehensive understanding of the modification of material properties by neutron irradiation is important for the design of future fission and fusion power reactors. Self-ion implantation is commonly used to mimic neutron irradiation damage, however an interesting question concerns the effect of ion energy on the resulting damage structures. The reduction in the thickness of the implanted layer as the implantation energy is reduced results in the significant quandary: Does one attempt to match the primary knock-on atom energy produced during neutron irradiation or implant at a much higher energy, such that a thicker damage layer is produced? In this work, we address this question by measuring the full strain tensor for two ion implantation energies, 2 MeV and 20 MeV in self-ion implanted tungsten, a critical material for the first wall and divertor of fusion reactors. A comparison of 2 MeV and 20 MeV implanted samples is shown to result in similar lattice swelling. Multi-reflection Bragg coherent diffractive imaging (MBCDI) shows that implantation induced strain is in fact heterogeneous at the nanoscale, suggesting that there is a non-uniform distribution of defects, an observation that is not fully captured by micro-beam Laue diffraction. At the surface, MBCDI and high-resolution electron back-scattered diffraction (HR-EBSD) strain measurements agree quite well in terms of this clustering/non-uniformity of the strain distribution. However, MBCDI reveals that the heterogeneity at greater depths in the sample is much larger than at the surface. This combination of techniques provides a powerful method for detailed investigation of the microstructural damage caused by ion bombardment, and more generally of strain related phenomena in micro-volumes that are inaccessible via any other technique.

36 MATERIALS SCIENCE↗

Ta–Zr carbides: Synthesis advances via carbothermal reduction and defect evolution observed through transmission electron microscopy ion irradiation

The thermodynamic stability of six distinct compositions within the Zr—Ta—C ternary system is investigated in this study, marking the first report of their synthesis through carbothermic reduction in vacuum. A prolonged annealing process at 2200°C enabled high densification and phase equilibrium. Detailed phase identification and microstructural characterization through microscopy and X-ray diffraction techniques revealed clear compositional trends and stable phase formations. Two compositions ((Ta 0.2 Zr 0.8 )C 0.6 and (Ta 0.5 Zr 0.5 )C 1 ) were selected for ion irradiation experiments using 200 keV Kr + at 600°C—representing the first-ever irradiation study on the Zr—Ta—C system. The findings indicated defect accumulation and nanoscale cavity formation without any evidence of amorphization, highlighting the system's structural stability under irradiation. Together, the synthesis and irradiation results provide a basis for further investigation of the system and suggest its relevance for applications under extreme environments.

36 MATERIALS SCIENCE↗

Humble planar defects in SiGe nanopillars

We report a {001} planar defect found in SiGe nanopillars. The defect structure, determined by atomic-resolution electron microscopy, matches the Humble defect model proposed for diamond. We also investigate several possible variants of the Humble structure using first-principles calculations and find that the one lowest in energy is in agreement with the scanning transmission electron microscope images. The pillar composition has been analyzed with electron energy loss spectroscopy, which hints at how the defect is formed. Our results show that the structure and formation process of defects in nanostructured group IV semiconductors can be different from their bulk counterparts.

36 MATERIALS SCIENCE↗

Application of a deep learning semantic segmentation model to helium bubbles and voids in nuclear materials

Imaging nanoscale radiation-induced defects using the transmission electron microscope (TEM) is a key factor in the successful implementation of materials for nuclear energy structural applications. Analyzing each defect in a TEM micrograph is currently a manual task. To identify the defects in a single image can take anywhere from 15 min to an hour and a project can require the analysis of anywhere from tens to ≥ 100 images. Here, we use artificial intelligence (AI) models to automate this task. For simplification, we evaluated images with only a single type of defect; helium bubbles. Additionally, we performed semantic segmentation of these helium bubble defects in electron microscopy images of irradiated FeCrAl alloys using a deep learning DefectSegNet model. This model, which was previously used to classify crystal defects, is inspired by the classic DenseNet and U-Net image segmentation models. It claims high spatial resolution, but has poor performance at object boundaries. Our paper improves the DefectSegNet model’s application by adding two new features. First, the DefectSegNet model is applied not only to perform calculation pixel-wise but also object (or feature) wise. Because object-wise metrics are directly relevant to our final goal of detecting bubbles, whereas pixel-wise classification is only an intermediate step, it is an important part of our study. Second, a distance map loss (DML) function has been added to increase its performance at object boundaries. It is crucial to accurately represent defects boundaries, especially bubbles, in order to track the bubble-induced swelling caused by irradiation. The boundary-focused DML function is also compared to other loss functions like Cross-entropy, Weighted Binary Cross Entropy (WBCE), Dice and Intersection over Union (IOU). Finally, by incorporating new features, we found a marked improvement on segmentation quality and better shape preservation at the boundaries and areas of the bubbles.

42 ENGINEERING↗

Probing Electron Beam Induced Transformations on a Single-Defect Level via Automated Scanning Transmission Electron Microscopy

A robust approach for real-time analysis of the scanning transmission electron microscopy (STEM) data streams, based on ensemble learning and iterative training (ELIT) of deep convolutional neural networks, is implemented on an operational microscope, enabling the exploration of the dynamics of specific atomic configurations under electron beam irradiation via an automated experiment in STEM. Combined with beam control, this approach allows studying beam effects on selected atomic groups and chemical bonds in a fully automated mode. Here, in this study, we demonstrate atomically precise engineering of single vacancy lines in transition metal dichalcogenides and the creation and identification of topological defects in graphene. The ELIT-based approach facilitates direct on-the-fly analysis of the STEM data and engenders real-time feedback schemes for probing electron beam chemistry, atomic manipulation, and atom by atom assembly.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic Force Microscopy to Characterize Antimicrobial Peptide-Induced Defects in Model Supported Lipid Bilayers

Antimicrobial peptides (AMPs) interact with bacterial cell membranes through a variety of mechanisms, causing changes extending from nanopore formation to microscale membrane lysis, eventually leading to cell death. Several AMPs also disrupt mammalian cell membranes, despite their significantly different lipid composition and such collateral hemolytic damage hinders the potential therapeutic applicability of the AMP as an anti-microbial. Elucidating the mechanisms underlying the AMP–membrane interactions is challenging due to the variations in the chemical and structural features of the AMPs, the complex compositional variations of cell membranes and the inadequacy of any single experimental technique to comprehensively probe them. (1) Background: Atomic Force Microscopy (AFM) imaging can be used in combination with other techniques to help understand how AMPs alter the orientation and structural organization of the molecules within cell membranes exposed to AMPs. The structure, size, net charge, hydrophobicity and amphipathicity of the AMPs affect how they interact with cell membranes of differing lipid compositions. (2) Methods: Our study examined two different types of AMPs, a 20-amino acid, neutral, α-helical (amphipathic) peptide, alamethicin, and a 13-amino acid, non-α-helical cationic peptide, indolicidin (which intramolecularly folds, creating a hydrophobic core), for their interactions with supported lipid bilayers (SLBs). Robust SLB model membranes on quartz supports, incorporating predominantly anionic lipids representative of bacterial cells, are currently not available and remain to be developed. Therefore, the SLBs of zwitterionic egg phosphatidylcholine (PC), which represents the composition of a mammalian cell membrane, was utilized as the model membrane. This also allows for a comparison with the results obtained from the Quartz Crystal Microbalance with Dissipation (QCM-D) experiments conducted for these peptides interacting with the same zwitterionic SLBs. Further, in the case of alamethicin, because of its neutrality, the lipid charge may be less relevant for understanding its membrane interactions. (3) Results: Using AFM imaging and roughness analysis, we found that alamethicin produced large, unstable defects in the membrane at 5 µM concentrations, and completely removed the bilayer at 10 µM. Indolicidin produced smaller holes in the bilayer at 5 and 10 µM, although they were able to fill in over time. The root-mean-square (RMS) roughness values for the images showed that the surface roughness caused by visible defects peaked after peptide injection and gradually decreased over time. (4) Conclusions: AFM is useful for helping to uncover the dynamic interactions between different AMPs and cell membranes, which can facilitate the selection and design of more efficient AMPs for use in therapeutics and antimicrobial applications.

Swana, Kathleen W.↗

Electron beam analysis induces Cl vacancy defects in a NaCl thin film

This work reports on the electron-induced modification of NaCl thin film grown on Ag(110). We show using low energy electron diffraction that electron beam bombardment leads to desorption and formation of Cl vacancy defects on NaCl surface. The topographic structure of these defects is studied using scanning tunneling microscopy (STM) showing the Cl defects as depressions on the NaCl surface. Most of the observed defects are mono-atomic vacancies and are located on flat NaCl terraces. Auger electron spectroscopy confirms the effect of electron exposure on NaCl thin films showing Cl atoms desorption from the surface. Using density functional theory taken into account the van der Waals dispersion interactions, we confirm the observed experimental STM measurements with STM simulation. Furthermore, comparing the adsorption of defect free NaCl and defective NaCl monolayer on Ag(110) surfaces, we found an increase of the adhesion energy and the charge transfer between the NaCl film and the substrate due to the Cl vacancy. In details, the adhesion energy increases between the NaCl film and the metallic Ag substrate from 30.4 meV Å –2 for the NaCl film without Cl vacancy and from 39.5 meV Å –2 for NaCl film with a single Cl vacancy. The charge transfer from the NaCl film to the Ag substrate is enhanced when the vacancy is created, from 0.63e – to 1.25e – .

Materials Science↗

The Role of Defect Geometry in Localized Emission from Monolayer Tungsten Dichalcogenides

In two-dimensional transition metal dichalcogenides such as tungsten diselenide (WSe 2 ), single photon emission has been broadly attributed to exciton localization from atomic point defects, yet the precise microscopic origins are unclear. This work introduces an empirically grounded computational framework that explains the origins of facile single photon emission in WSe 2 . High-resolution microscopy identifies native defect geometries in monolayer WSe 2 lattices from which the model is built. Here, the qualitative effects of chalcogen type, defect geometry, and mechanical strain on the electronic structure are individually assessed using density functional theory, and a specific divacancy configuration emerges as the candidate for localized single-electron transitions that match observed spectral energies. Spectroscopy and photon correlation measurements further validate this model, establishing a self-consistent link between defect geometry, electronic structure, and quantum emission.

defect emission↗

Scanning Transmission Electron Microscopy–Atom Probe Tomography Correlative Analysis for the Characterization of Solute-defect Interactions

Atom probe tomography (APT) and (scanning) transmission electron microscopy ((S)TEM) are complementary techniques that provide spatially resolved chemical and structural information at the atomic scale. Here, in this study, we employ two different STEM/APT correlative analysis methods to investigate Cr segregation at dislocation loops in ultra-high purity Fe–Cr alloys. APT needles for the correlative analysis were extracted either from bulk material or from thinned TEM lamellae. STEM analysis was used to determine the Burgers vectors of ion-irradiation-induced dislocation loops, while APT reconstruction of the same region revealed the Cr segregation to these loops. We extended the g•b = 0 invisibility criterion of dislocation loops from TEM mode in a lamella to STEM mode in a needle-shaped specimen. STEM and APT analysis on the same needle provide straightforward correlative analysis, although it is limited by a small observation volume. In contrast, iterative STEM analysis of TEM lamellae, followed by the selective extraction of specific regions of interest for APT analysis, expands the observation area by up to 100 times but requires additional time-consuming steps for APT needle extraction from the lamellae.

47 OTHER INSTRUMENTATION↗

Characterization of radiation damage in 3D printed SiC

The SiC fuel matrix for advanced gas-cooled high temperature reactors as part of the Transformational Challenge Reactor program serves as the fuel particle container structure, a barrier to fission gas release, and a heat transfer medium. Its performance is particularly important because the fuel matrix must demonstrate good structural stability and thermal behaviors. An additive manufacturing methodology combining a binder jet 3D printing process with chemical vapor infiltration (CVI) for the production of SiC was recently developed. In this study, post irradiation examination by transmission electron microscopy shows that defect accumulation within the printed particles is very similar to other forms of high-purity SiC. However, damage accumulation was not directly observed in the CVI matrix because black spot damage and dislocation loops are difficult to image within the nanoscale highly faulted CVI matrix and because interstitial defects may rapidly annihilate at the stacking faults. Therefore, electron energy loss spectroscopy (EELS) analysis was used to analyze defect swelling in both the printed particles and the CVI matrix. The EELS analysis helped reveal that the radiation-induced swelling in the CVI matrix is similar to that of the printed SiC particles. This work shows that 3D printed SiC has behavior that is comparable to SiC processed by other means and that 3D printing could serve as a suitable processing technique for high-purity SiC for nuclear applications.

36 MATERIALS SCIENCE↗

Locally Engineering and Interrogating the Photoelectrochemical Behavior of Defects in Transition Metal Dichalcogenides

Transition metal dichalcogenides (TMDs) are attractive materials for a variety of applications in solar energy conversion and electrocatalysis, due to their favorable optical and electrical properties and their unique two-dimensional structures which facilitate the fabrication of wide-area, ultrathin layers. Unfortunately, the basal planes which make up the majority of these materials are relatively inert, and thus a great deal of effort has been directed to engineering favorable, catalytically active defects into these materials. In this paper, we demonstrate how probe-based electrochemical techniques can be employed as multifunctional tools for locally modifying TMD materials and probing the electrochemical behavior of the resulting defects. Scanning Electrochemical Cell Microscopy (SECCM) was employed to locally anodize exfoliated p-type WSe 2 nanosheets, creating hole-like defects within individual basal planes in a highly controllable fashion. Photoelectrochemical SECCM imaging was then employed to characterize the chemical behavior of these engineered defects, revealing significantly enhanced activity toward the Hydrogen Evolution Reaction (HER). Atomic force microscopy studies are presented which suggest these enhancements result from an increased density of monolayer-high step features within the anodized defects. Analysis of the SECCM data in the context of finite element simulations revealed that these enhancements increased with increasing anodization time, with local kinetic rates over 2 orders of magnitude higher than unaltered basal planes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Alternating-bias assisted annealing of amorphous oxide tunnel junctions

Superconducting quantum bits (qubits) rely on ultra-thin, amorphous oxide tunneling barriers that can have significant inhomogeneities and defects as grown. This can result in relatively large uncertainties and deleterious effects in the circuits, limiting the scalability. Finding a robust solution to the junction reproducibility problem has been a long-standing goal in the field. Here, we demonstrate a transformational technique for controllably tuning the electrical properties of aluminum-oxide tunnel junctions. This is accomplished using a low-voltage, alternating-bias applied individually to the tunnel junctions, with which resistance tuning by more than 70% can be achieved. The data indicates an improvement of coherence and reduction of two-level system defects. Transmission electron microscopy shows that the treated junctions are predominantly amorphous, albeit with a more uniform distribution of alumina coordination across the barrier. This technique is expected to be useful for other devices based on ionic amorphous materials.

36 MATERIALS SCIENCE↗

Water content modulation enables selective ion transport in 2D MXene membranes

Separation membranes are critical for a range of processes, including but not limited to water desalination, chemical and fuel production, and recycling and recovery applications. Fundamentally, there are intrinsic trade-offs between permeability and selectivity. Local water organization and content can impact membrane structure (short- and long-range) in laminar transition metal carbide (MXene) membranes and impact selective ion permeation. Intercalation of chaotropic cesium (Cs + ) ions within the layers reduces the water content in the membrane and at the surface which cannot be found in the intercalation of other ions. Additionally, 3D imaging using focused ion beam scanning electron microscopy showed fewer defects in the Cs-MXene membrane, due to reduced local water content, leading to more efficient ion sieving. X-ray diffraction and density functional theory calculations on the nanochannel structure demonstrated that the chaotropic ion results in the smallest nanochannel size and induces a stronger resistance to water-induced nanochannel swelling. With a narrower nanochannel, the Cs-MXene membrane limits ion transport pathways, resulting in more selective transport of lithium over other metal cations, as evidenced in both experiment and molecular dynamics simulations. In conclusion, our findings highlight the potential for controlling the structural organization of 2D MXene membranes to enable on-demand transport of ions for diverse applications.

36 MATERIALS SCIENCE↗

Characterization of Build Parameters and Microstructure in Low Heat Input WAAM of Ni-Based Superalloy Haynes 282

Ni-based superalloy Haynes® 282® is being targeted for various applications in advanced power generation systems for its superior fabricability, weldability, and excellent high temperature creep and corrosion performance. This process optimization study aims to use a low heat-input, high deposition rate, controlled Gas Metal Arc Welding (GMAW) process, Cold Metal Transfer (CMT) by Fronius, attempting to achieve fully dense fabrication and possibly avoid the need for HIP. Twenty-one multilayer blocks (~25x100x40 mm3) were deposited to explore a large set of build parameters variations that focused on varying the travel speed from 14 to 42 inches per minute (ipm) and wire feed speed from 150 to 450 ipm. A strong correlation has been observed between arc energy – controlled primarily by travel and wire feed speed. Initial visual inspection, internal microstructural examination, and computed tomography (CT) have been used to determine the effects of built parameters on evolution of internal porosity and defects. Scanning electron microscopy techniques enabled structural and compositional imaging of heterogeneity and changes in microstructural properties.

additive manufacturing↗

Characterization of Build Parameters and Microstructure in Low Heat Input WAAM of Ni-Based Superalloy Haynes 282

Ni-based superalloy Haynes® 282® is being targeted for various applications in advanced power generation systems for its superior fabricability, weldability, and excellent high temperature creep and corrosion performance. This process optimization study aims to use a low heat-input, high deposition rate, controlled Gas Metal Arc Welding (GMAW) process, Cold Metal Transfer (CMT) by Fronius, attempting to achieve fully dense fabrication and possibly avoid the need for HIP. Twenty-one multilayer blocks (~25x100x40 mm3) were deposited to explore a large set of build parameters variations that focused on varying the travel speed from 14 to 42 inches per minute (ipm) and wire feed speed from 150 to 450 ipm. A strong correlation has been observed between arc energy – controlled primarily by travel and wire feed speed. Initial visual inspection, internal microstructural examination, and computed tomography (CT) have been used to determine the effects of built parameters on evolution of internal porosity and defects. Scanning electron microscopy techniques enabled structural and compositional imaging of heterogeneity and changes in microstructural properties.

additive manufacturing↗