Search NASA⌕ Search

SEARCH · Search NASA

Results for “design for X”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Electrolyte Design for NMC811||SiO x -Gr Lithium-Ion Batteries with Excellent Low-Temperature and High-Rate Performance

The use of high-nickel NMC811 cathode and SiO x -Gr anode can greatly improve the overall energy densities of lithium-ion batteries. However, the unfavorable solid electrolyte interphase (SEI) layer generated from the decomposition of EC-based electrolytes lead to the poor cycling stability of NMC811||SiO x -Gr cells. Here we report an electrolyte design of 1.5 M LiPF 6 dissolved in FEC/MA/BN 2:2:6 by volume, which can form thin, robust, and homogeneous SEI layer to greatly improve the charge transfer at the electrode-electrolyte interface. Importantly, the designed electrolyte shows an outstanding low temperature performance that it can deliver a capacity of 123.3 mAh g –1 after 50 cycles at −20 °C with a current density of 0.5 C, overwhelming the standard EC-based electrolyte (1.2 M LiPF 6 EC/EMC 3:7 by volume) with a capacity of 35.7 mAh g –1 . The electrolyte also has a superior rate performance that it achieves a capacity of 122.5 mAh g −1 at a high current density of 10 C. Moreover, the LTE electrolyte holds the great potential of extreme fast-charging ability because of the large part of CC contribution in the CCCV charging model at high charging current densities.

Electrochemistry↗

Capsule Design and Preparation for YH x Specimen Irradiation in the High Flux Isotope Reactor

Advanced nuclear systems for terrestrial microreactors and space applications require moderator materials with high thermal stability, hydrogen retention, and efficient neutron moderation. Yttrium hydride (YH x ) is a promising candidate, but its irradiation performance and hydrogen stability remain insufficiently understood. To address this, Oak Ridge National Laboratory (ORNL) and Los Alamos National Laboratory, supported by the US Department of Energy’s Nuclear Science User Facilities program, have initiated an irradiation campaign in ORNL’s High Flux Isotope Reactor. The experiment employs six irradiation capsules containing YH x specimens (H/Y ≈ 1.9) designed for three target temperatures (300°C, 400°C, and 500°C) and two distinct neutron fast fluence levels. This report documents the irradiation test matrix, capsule design, specimen precharacterization, and experiment readiness for insertion. Planned postirradiation examinations will provide new insights into hydrogen retention and microstructural stability, advancing the understanding of YHx as a moderator for compact reactor applications.

36 MATERIALS SCIENCE↗

Conceptual design and performance predictions for 2D beam emission spectroscopy turbulence measurements at Wendelstein 7-X

A conceptual design for a 2D beam emission spectroscopy diagnostic system to measure ion gyro-scale plasma turbulence at Wendeslstein 7-X is described. The conceptual design identifies field-aligned viewing geometries and ports for cross-field turbulence measurements in the neutral beam volume. A 2D sightline grid covers the outer plasma region, and the grid configuration provides sufficient k-space coverage in radial and poloidal directions for ion temperature gradient and trapped-electron mode turbulence measurements. Emission intensity estimates, optical transmission losses, and detector noise levels indicate that the measurements will be sensitive to plasma density fluctuations as small as δn/n ≈ 0.5% with a bandwidth of 1 MHz. Implementation challenges include a small beam emission Doppler shift due to nearly radial heating beams and reduced optical throughput due to collection aperture limitations.

47 OTHER INSTRUMENTATION↗

Adapted Cell Design for the Operando X‑Ray Absorption Study of a Structurally Evolving Cu Nanoparticle Ensemble during the CO2 Electroconversion to Multicarbon Products

An improved understanding of the materials that will sustain the future of energy production, storage, and delivery calls for better characterization tools. Operando characterization methods have thus become essential for investigating electrocatalytic materials. Without their resulting insights, the study of highly performing catalysts post-mortem cannot viably facilitate the further development of functional catalysts. Herein, we present an operando electrochemical cell designed for hard X-ray absorption spectroscopy (XAS) and specifically adapted to the study of an electrocatalytically active Cu nanoparticle ensemble. So far, this nanocatalyst has proven to pose quite a challenge to characterize due to its unique structural dynamics. Adopting a design comparable to the H-cell employed for all activity testing, we report the satisfactory translation of the active site formation into an XAS-compatible cell. The simultaneous collection of CO2-derived products during XAS characterization enabled the operando characterization of this CO2-reducing active structure. We report a Cu–Cu coordination number of the first scattering path higher than suggested in our previous studies, highlighting the importance of monitoring metastable nanoelectrocatalysts in operando. This study illustrates important caveats for the electrocatalysis community when considering the application of operando XAS. Our results highlight that the sample size, homogeneity, and stability determine how to interpret the measured signal. Considering these parameters carefully, the operando EXAFS results confirm the exceptional undercoordinated character of the Cu nanoparticle ensemble during CO2 reduction to C2+ products.

Louisia, Sheena↗

Bayesian optimization to design a novel x-ray shaping device

In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC) - a complex mechatronic device comprising over one hundred individually powered tungsten ‘leaves’ that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed “SPHINX”: Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray “beamlets.” A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm 2 were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. The optimized 5–, 7–, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm 2 and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 ±1.9 mm to 0.01 ±0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm 2 field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray FEL linear accelerator design via start-to-end global optimization

An X-ray Free Electron Laser (FEL) prefers using an electron beam with low emittance, small energy spread, and a high core current to generate coherent radiation through an undulator. In order to attain such a high brightness beam, the linear accelerator beam dynamics design generally involves separate photoinjector optimization and linac optimization. In this paper, we propose a new beam dynamics design strategy based on global optimization with fast start-to-end simulations from the photocathode to the end of the accelerator. The new start-to-end model significantly reduces the simulation time and makes the global optimization practical. The global optimization method avoids the need to choose a single solution based on bunch length at the injector exit for the linac optimization and helps find the solution with unfavorable bunch length at the injector exit but better phase space distribution that can result in better final electron beam phase space distribution at the entrance of the undulator. Here, using the start-to-end global optimization, we showed in an application example, with a 100 pC beam that good transverse emittance and over kilo-Ampere final core current can be attained using a photoinjector that consists of a VHF gun and boosting RF cavities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Custom Low-Noise Silicon Photodiode Detector Designed for Use With X-Ray Capillary Optics

We present the first results of a custom low-noise silicon photodiode detector designed for use with X-ray capillary optics. This system is intended to perform as a smaller, lighter, and low-powered alternative to currently existing X-ray telescope technologies. The detector has an active area with a diameter of 100 μm, and its small size leads to a low capacitance of well under 1 pF and a leakage current of 1 pA or less at the depletion voltage. We tested the detector with both a discrete preamp and an ultralow-noise front-end application-specific integrated circuit (ASIC). The front-end ASIC, developed at Brookhaven National Laboratory, was designed for low-capacitance detectors but had not been previously tested with a detector. Here, we discuss the detector design, the experimental setup, and the resulting detector performance. Using radioactive laboratory sources, we measure a full-width at half-maximum (FWHM) of 211 ± 8 eV at 5.9 keV with the ASIC and are able to set the threshold as low as 0.6 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monolithically Integrated $\varepsilon$-Ge/In x Ga 1-x As Quantum Well Laser Design: Experimental and Theoretical Investigation

Here, we have analyzed the electrical and optical phenomenon occurring in a $\varepsilon$-Ge/In x Ga 1-x -Ge/In x Ga 1-x As quantum well (QW) laser through self-consistent physical solvers calibrated using in-house experimental results. A separate confinement heterostructure QW design is proposed to enable lasing from tensile strained germanium ($\varepsilon$-Ge/In x Ga 1-x -Ge) in the range of 1.55 um to 4 um wavelengths as a function of QW thickness and indium (In) composition. Different recombination mechanisms were analyzed as a function of tensile strain in $\varepsilon$-Ge/In x Ga 1-x -Ge QW. Minority carrier lifetime and band alignment are key attributes of a QW laser, which were measured using microwave photoconductive decay and x-ray photoelectron spectroscopy (as a function of In composition), respectively. The transition point of Ge to a direct bandgap material is re-affirmed to be at $\varepsilon$-Ge/In x Ga 1-x = 1.6% (In ~24%) and the transition from type I to type II for $\varepsilon$-Ge/In x Ga 1-x -Ge/In x Ga 1-x As QW is found to be at In ~55%. Also, the transition to a TM mode dominant laser is identified at In ~15%. Using a tunable waveguide design to optimize confinement as a function of In composition, strain, wavelength, QW thickness, refractive index, and geometry, the $\varepsilon$-Ge/In x Ga 1-x -Ge QW laser design provided a net material gain of ~2000 cm -1 and a threshold current density of ~5 kA/cm 2 , which is an improvement over existing Ge based lasers. In conclusion, the impact of In composition and QW thickness on the band structure, polarized gain spectra, and various lasing metrics were analyzed to show $\varepsilon$-Ge/In x Ga 1-x -Ge/InGaAs QW lasers as promising for integrated photonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A design of resonant inelastic X-ray scattering (RIXS) spectrometer for spatial- and time-resolved spectroscopy

The optical design of a Hettrick–Underwood-style soft X-ray spectrometer with Wolter type 1 mirrors is presented. The spectrometer with a nominal length of 3.1 m can achieve a high resolving power (resolving power higher than 10000) in the soft X-ray regime when a small source beam (<3 µm in the grating dispersion direction) and small pixel detector (5 µm effective pixel size) are used. Adding Wolter mirrors to the spectrometer before its dispersive elements can realize the spatial imaging capability, which finds applications in the spectroscopic studies of spatially dependent electronic structures in tandem catalysts, heterostructures, etc . In the pump–probe experiments where the pump beam perturbs the materials followed by the time-delayed probe beam to reveal the transient evolution of electronic structures, the imaging capability of the Wolter mirrors can offer the pixel-equivalent femtosecond time delay between the pump and probe beams when their wavefronts are not collinear. In combination with some special sample handing systems, such as liquid jets and droplets, the imaging capability can also be used to study the time-dependent electronic structure of chemical transformation spanning multiple time domains from microseconds to nanoseconds. The proposed Wolter mirrors can also be adopted to the existing soft X-ray spectrometers that use the Hettrick–Underwood optical scheme, expanding their capabilities in materials research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Molecular Design of Supported MoO x Catalysts with Surface TaO x Promotion for Olefin Metathesis

A series of supported 3% MoOx catalysts were synthesized by incipient-wetness impregnation of 5%-15% TaO x surface modified γ-Al 2 O 3 support. The catalysts were characterized by in situ spectroscopies (DRIFTS, Raman, UV-vis, XAS) and multiple chemical probes (C 2 H 4 /C 4 H 8 titration, C 3 H 6 -TPSR, steady state propylene metathesis, NH 3 -IR adsorption). The supported tantalum oxide phase was present as surface TaO x sites on the γ-Al 2 O 3 support that capped that Al 2 O 3 surface hydroxyls. The change in available surface hydroxyls caused the subsequent anchoring of MoOx species to occur at different surface hydroxyls. This shifted the anchoring of MoO x species from basic (Al-OH) to neutral (Al 2 -OH) to more acidic (Al 3 -OH) surface hydroxyls as well as perturbation of the remaining alumina surface hydroxyls by the surface TaO x sites. The TaO x surface modified γ-Al 2 O 3 support increased the number of activated surface MoO x sites (Ns) by ~6x and the TOF by ~10x resulting in an increased activity of ~60x. In conclusion, It was found that the specific anchoring surface hydroxyls rather than the extent of oligomerization of the surface MoO x sites control the number of activated MoO x sites and TOF for propylene metathesis. No relationship between the nature of the surface Lewis/Brønsted acid sites and Ns and TOF were found to be present.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗