Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Extreme ultraviolet quantum detection efficiency of rubidium bromide opaque photocathodes

Measurements are presented of the quantum detection efficiency (QDE) of three samples of RbBr photocathode layers over the 44-150-A wavelength range. The QDE of RbBr-coated microchannel plate (MCP) was measured using a back-to-back Z-stack MCP configuration in a detector with a wedge and strip position-sensitive anode, of the type described by Siegmund et al. (1984). To assess the stability of RbBr layer, the RbBr photocathode was exposed to air at about 30 percent humidity for 20 hr. It was found that the QDE values for the aged cathode were within the QDE measurement errors of the original values. A simple QDE model was developed, and it was found that its predictions are in accord with the QDE measurements.

Siegmund, Oswald H. W.↗

Lightning Detection Efficiency Analysis Process: Modeling Based on Empirical Data

A ground based lightning detection system employs a grid of sensors, which record and evaluate the electromagnetic signal produced by a lightning strike. Several detectors gather information on that signal s strength, time of arrival, and behavior over time. By coordinating the information from several detectors, an event solution can be generated. That solution includes the signal s point of origin, strength and polarity. Determination of the location of the lightning strike uses algorithms based on long used techniques of triangulation. Determination of the event s original signal strength relies on the behavior of the generated magnetic field over distance and time. In general the signal from the event undergoes geometric dispersion and environmental attenuation as it progresses. Our knowledge of that radial behavior together with the strength of the signal received by detecting sites permits an extrapolation and evaluation of the original strength of the lightning strike. It also limits the detection efficiency (DE) of the network. For expansive grids and with a sparse density of detectors, the DE varies widely over the area served. This limits the utility of the network in gathering information on regional lightning strike density and applying it to meteorological studies. A network of this type is a grid of four detectors in the Rondonian region of Brazil. The service area extends over a million square kilometers. Much of that area is covered by rain forests. Thus knowledge of lightning strike characteristics over the expanse is of particular value. I have been developing a process that determines the DE over the region [3]. In turn, this provides a way to produce lightning strike density maps, corrected for DE, over the entire region of interest. This report offers a survey of that development to date and a record of present activity.

Rompala, John T.↗

Ultraviolet quantum detection efficiency of potassium bromide as an opaque photocathode applied to microchannel plates

The quantum detection efficiency (QDE) of potassium bromide as a photocathode applied directly to the surface of a microchannel plate over the 250-1600 A wavelength range has been measured. The contributions of the photocathode material in the channels and on the interchannel web to the QDE have been determined. Two broad peaks in the QDE centered at about 450 and about 1050 A are apparent, the former with about 50 percent peak QDE and the latter with about 40 percent peak QDE. The photoelectric threshold is observed at about 1600 A, and there is a narrow QDE minimum at about 750 A which correlates with 2X the band gap energy for KBr. The angular variation of the QDE from 0 to 40 deg to the channnel axis has also been examined. The stability of Kbr with time is shown to be good with no significant degradation of QDE at wavelengths below 1216 A over a 15-day period in air.

Siegmund, Oswald H. W.↗

Evaluation of the absolute single-photon detection efficiency of HRPPD

Pixelated High Rate Picosecond Photon Detectors (HRPPDs) by Incom Inc. are promising photosensors for use in Ring Imaging CHerenkov (RICH) detectors, where a high gain, sub-mm position resolution and sub-100ps timing resolution are required in a single photon mode. Quantum Efficiency (QE) has been measured for the first batch of EIC HRPPDs both by Incom and EIC research groups at Jefferson Lab and Brookhaven Lab, with peak values at ∼365 nm typically exceeding 30%. Furthermore, in this study, we present a first direct measurement of Photon Detection Efficiency being equal to (17.1 ± 0.1 [stat] ± 0.3 [sys])% at 398.6 nm, for a pixel near the center of HRPPD, in a photoelectron pulse counting mode using a picosecond diode laser. HRPPD QE at the same spot and at the same wavelength was evaluated to be (24.4 ± 0.1 [stat] ± 0.3 [sys])%, leading to a Collection Efficiency estimate of (70.3 ± 1.6)%, which is consistent with the expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determining the Quantum Detection Efficiency of A Soft X-Ray Micro-Channel Plate Detector for the Lunar Mission, LEXI

Micro-channel plate (MCP) detectors have long been a workhorse for space-based x-ray research and are advantageous over other imaging detectors because of their low size, weight and power. The Lunar Environment heliospheric x-ray Imager (LEXI), will utilize a MCP to image Earth’s magnetosphere in soft x-rays from the lunar surface. A critical element for interpreting on-orbit data is to understand the quantum detection efficiency (QDE) of the MCP. LEXI’s MCP is coated with potassium bromide (KBr) to increase the soft x-ray QDE. Historically, few measurements of QDE exist in the soft x-ray band for KBr detectors. This paper reviews the performance of LEXI’s detector, and the QDE experiment procedure conducted at and results from the Advanced Light Source synchrotron soft x-ray beam line (6.3.2) over the energy range 70eV-1300eV. A unique beam line setup was required to limit the photon flux as to not saturate the pores of the MCP or detector signal chain. The experimental results are similar to previous literature, with some caveats unique to this MCP and experimental setup.

X-ray imaging↗

Measurements of electron detection efficiencies in solid state detectors.

Detailed laboratory measurement of the electron response of solid state detectors as a function of incident electron energy, detector depletion depth, and energy-loss discriminator threshold. These response functions were determined by exposing totally depleted silicon surface barrier detectors with depletion depths between 50 and 1000 microns to the beam from a magnetic beta-ray spectrometer. The data were extended to 5000 microns depletion depth using the results of previously published Monte Carlo electron calculations. When the electron counting efficiency of a given detector is plotted as a function of energy-loss threshold for various incident energies, the efficiency curves are bounded by a smooth envelope which represents the upper limit to the detection efficiency. These upper limit curves, which scale in a simple way, make it possible to easily estimate the electron sensitivity of solid-state detector systems.

Lupton, J. E.↗

Monte Carlo Simulations for Evaluating the Accuracy of GLM Detection Efficiency and False Alarm Rate Retrievals

The performance of the Geostationary Lightning Mapper has been evaluated through comparison with other satellite lightning sensors and ground-based networks. However, because the performance of these reference sensors is both imperfect and imperfectly known, the true performance of GLM can only be estimated through such a process. In particular, GLM performance metrics such as detection efficiency (DE) and false alarm rate (FAR) retrieved through comparison with reference networks are affected by those networks’ own DE, FAR, and spatiotemporal accuracy, as well as the selected flash matching criteria. This study presents follow-on results from an ongoing analysis that uses a Monte Carlo simulation-based inversion technique to quantify the effect on retrieved GLM performance of a reasonable range of reference network DE, FAR, spatiotemporal accuracy, and the associated geographic patterns of each. These results help quantify and bound the actual performance of GLM and the attendant uncertainties when comparing GLM to imperfect reference networks.

Katrina Virts↗

Determining the Detection Efficiency and Background Level of ATIC Electron Observation from Flight Data

Observations of Cosmic-ray electrons are difficult due to the large flux of cosmic ray hadrons. The event selection efficiency and background levels can be estimated from flight data for the ATIC instrument. This reduces the dependence upon Monte Carlo simulations, which show differences between different codes, thereby reducing the systematic errors resulting from analyses that only use simulations. This paper discusses some of the methods used in the ATIC analysis to determine the detection efficiency and background level for the flight data.

Chang, J.↗

Detection efficiency measurement and operational tests of the X-Arapuca for the first module of DUNE far detector

The Deep Underground Neutrino Experiment (DUNE) is a dual-site experiment for long-baseline neutrino oscillation studies, able to resolve the neutrino mass hierarchy and measure δ$_{CP}$. DUNE will also have sensitivity to supernova neutrinos and to processes beyond the Standard Model, such as nucleon decay searches. The Far Detector (FD) will consist of four liquid argon TPC (17.5 kt total mass) with systems for the detection of charge and scintillation light produced by an ionization event. The charge detection system permits both calorimetry and position determination. In addition, the photon-detection system (PDS) enhances the detector capabilities for all DUNE physics drivers. The PDS of the first FD module consists of light collector modules placed in the inactive space between the innermost wire planes of the TPC anode. The light collectors, the so-called X-ARAPUCAS, are functionally a light trap that captures wavelength-shifted photons inside boxes with highly reflective internal surfaces where they are guided to Silicon Photo-multipliers (SiPM) by wavelength-shifting (WLS) bars. Functionality and operational tests of the X-ARAPUCAS to be installed in ProtoDUNE-SP phase II (FD DUNE prototype at the scale 1:20), as well as the measurement of their absolute detection efficiency is reported in this publication.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Efficient detection of a CW signal with a linear frequency drift

An efficient method is presented for the detection of a continuous wave (CW) signal with a frequency drift that is linear in time. Signals of this type occur in transmissions between any two locations that are accelerating relative to one another, e.g., transmissions from the Voyager spacecraft. We assume that both the frequency and the drift are unknown. We also assume that the signal is weak compared to the Gaussian noise. The signal is partitioned into subsequences whose discrete Fourier transforms provide a sequence of instantaneous spectra at equal time intervals. These spectra are then accumulated with a shift that is proportional to time. When the shift is equal to the frequency drift, the signal to noise ratio increases and detection occurs. Here, we show how to compute these accumulations for many shifts in an efficient manner using a variety of Fast Fourier Transformations (FFT). Computing time is proportional to L log L where L is the length of the time series.

Swarztrauber, Paul N.↗

Light output and neutron detection efficiency of boron-based neutron scintillator screens for neutron imaging

Recent research has explored the development of boron-based neutron scintillator screens, which potentially offer improved spatial resolution and neutron capture efficiency compared to traditional lithium-based screens. This work builds upon previous efforts to improve boron-based neutron scintillators by assessing a newer generation of boron-based scintillator screens fabricated using different compositions and fabrication approaches compared to previous generations of screens. Some of the test screens exhibit higher light output than previous efforts and higher neutron capture efficiency than lithium-based screens. This paper describes the current state of screen development, measurement results for the most recent generation of screens, and future activities.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Effects of trapped charge on the signal formation and detection efficiency for subsequent pulses in irradiated silicon sensors

Envisaged high energy physics experiments like the Future Circular Collider require unprecedented radiation hardness of the detectors, as well as short readout time due to high luminosity and occupancy. Silicon has proven to be extremely radiation hard. Sufficient signals can be recorded even at fluences close to 1 ∙ 1 0 16 n e q / cm 2 . Here, the signal formation was studied in silicon strip sensors, irradiated and annealed until the phenomenon of charge multiplication occurred. ATLAS12EC R0 mini sensors were tested by means of edge TCT measurements at temperatures around –20 °C. It was observed that the detection of subsequent signals separated up to several microseconds is altered by the charge trapped during the preceding pulses. The effects of trapped charge on the electrical configuration of a sensor are well known as a polarization or pumping effect in larger band-gap materials like diamond, but is often neglected for silicon at this relatively high temperature. The investigation of the effect created by trapped charges in silicon sensors using subsequent pulses allows to gain information on important parameters such as de-trapping times. Furthermore, it shows a severe impact on the sensor performance in a pile-up scenario. The irradiation fluence and hence the effective doping concentration, the temperature and the amount of initially created charge have a large impact on this phenomenon. The measurements presented help to characterize this phenomenon; particular attention was paid to the application point of view.

47 OTHER INSTRUMENTATION↗

Efficient Detection of Emission-line Galaxies in the Cl0016+1609 and MACSJ1621.4+3810 Supercluster Filaments Using SITELLE

We observe a system of filaments and clusters around Cl0016+1609 and MACSJ1621.4+3810 using the SITELLE Fourier transform spectrograph at the Canada–France–Hawaii Telescope. For Cl0016+1609 (z = 0.546), the observations span an 11.8 Mpc × 4.3 Mpc region along an eastern filament that covers the main cluster core, as well as two 4.3 Mpc × 4.3 Mpc regions that each cover southern subclumps. For MACSJ1621.4+3810 (z = 0.465), 3.9 Mpc × 3.9 Mpc around the main cluster core is covered. We present the frequency and location of the emission-line galaxies and their emission-line images, and calculate the star formation rates, specific star formation rates, and merger statistics. In Cl0016+1609, we find 13 [O ii] 3727 Å emitting galaxies with star formation rates between 0.2 and 14.0 M {sub ⊙} yr{sup −1}. Of these, 91{sub −10}{sup +3}% are found in regions with moderate local galaxy density, avoiding the dense cluster cores. These galaxies follow the main filament of the superstructure and are mostly blue and disky, with several showing close companions and merging morphologies. In MACSJ1621.4+3810, we find 10 emission-line sources. All are blue (100{sub −15}{sup +0}%), with 40{sub −12}{sup +16}% classified as disky and 60{sub −16}{sup +12}% as merging systems. Eight avoid the cluster core (80{sub −17}{sup +7}%), but two (20{sub −7}{sup +17}%) are found near high-density regions, including the brightest cluster galaxy (BCG). These observations push the spectroscopic study of galaxies in filaments beyond z ∼ 0.3 to z ∼ 0.5. Their efficient confirmation is paramount to their usefulness as more galaxy surveys come online.

47 OTHER INSTRUMENTATION↗