Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection threshold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Temporal variation in spectral detection thresholds of substrate and vegetation in AVIRIS images

The ability to map changes over large surface areas over time is one of the advantages in using remote sensing as a monitoring tool. Temporal changes in the surface may be gradual, making them difficult to detect in the short-term, and because they commonly occur at the subpixel scale, they may be difficult to detect in the long-term as well. Also, subtle changes may be real or merely an artifact of image noise. It is, therefore, necessary to understand the factors that limit the detection of surface materials in evaluating temporal data. The spectral detectability of vegetation and soil in the 1990 July and October Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data of Jasper Ridge, CA was evaluated and compared.

Sabol, Donald E., Jr.↗

Threshold computations for detection of failures in SISO systems with transfer function errors

The author considers the problem of detecting failures in SISO systems using analytic redundancy concepts. Since the models used are subject to error, a method of determining the detection thresholds that account for these errors is sought. The methodology presented utilizes a straightforward application of Parseval's relation to develop a threshold computation that is performed online as a function of the input signal. The threshold is set at a quiescent value to account for sensor noise and is adjusted (upward) according to the activity of the input signal. An application to detection of actuator failures is presented.

Weiss, Jerold L.↗

Flood Extent Mapping for Namibia Using Change Detection and Thresholding with SAR

A new method for flood detection change detection and thresholding (CDAT) was used with synthetic aperture radar (SAR) imagery to delineate the extent of flooding for the Chobe floodplain in the Caprivi region of Namibia. This region experiences annual seasonal flooding and has seen a recent renewal of severe flooding after a long dry period in the 1990s. Flooding in this area has caused loss of life and livelihoods for the surrounding communities and has caught the attention of disaster relief agencies. There is a need for flood extent mapping techniques that can be used to process images quickly, providing near real-time flooding information to relief agencies. ENVISAT/ASAR and Radarsat-2 images were acquired for several flooding seasons from February 2008 to March 2013. The CDAT method was used to determine flooding from these images and includes the use of image subtraction, decision based classification with threshold values, and segmentation of SAR images. The total extent of flooding determined for 2009, 2011 and 2012 was about 542 km2, 720 km2, and 673 km2 respectively. Pixels determined to be flooded in vegetation were typically <0.5 % of the entire scene, with the exception of 2009 where the detection of flooding in vegetation was much greater (almost one third of the total flooded area). The time to maximum flooding for the 2013 flood season was determined to be about 27 days. Landsat water classification was used to compare the results from the new CDAT with SAR method; the results show good spatial agreement with Landsat scenes.

Flood↗

Effect of model uncertainty on failure detection - The threshold selector

The performance of all failure detection, isolation, and accomodation (DIA) algorithms is influenced by the presence of model uncertainty. A unique framework is presented to incorporate a knowledge of modeling error in the analysis and design of failure detection systems. The tools being used are very similar to those in robust control theory. A concept is introduced called the threshold selector, which is a nonlinear inequality whose solution defines the set of detectable sensor failure signals. The threshold selector represents an innovative tool for analysis and synthesis of DIA algorithms. It identifies the optimal threshold to be used in innovations-based DIA algorithms. The optimal threshold is shown to be a function of the bound on modeling errors, the noise properties, the speed of DIA filters, and the classes of reference and failure signals. The size of the smallest detectable failure is also determined. The results are applied to a multivariable turbofan jet engine example, which demonstrates improvements compared to previous studies.

Emami-Naeini, Abbas↗

Improved Detection System Description and New Method for Accurate Calibration of Micro-Channel Plate Based Instruments and Its Use in the Fast Plasma Investigation on NASA's Magnetospheric MultiScale Mission

The Fast Plasma Investigation (FPI) on NASAs Magnetospheric MultiScale (MMS) mission employs 16 Dual Electron Spectrometers (DESs) and 16 Dual Ion Spectrometers (DISs) with 4 of each type on each of 4 spacecraft to enable fast (30 ms for electrons; 150 ms for ions) and spatially differentiated measurements of the full 3D particle velocity distributions. This approach presents a new and challenging aspect to the calibration and operation of these instruments on ground and in flight. The response uniformity, the reliability of their calibration and the approach to handling any temporal evolution of these calibrated characteristics all assume enhanced importance in this application, where we attempt to understand the meaning of particle distributions within the ion and electron diffusion regions of magnetically reconnecting plasmas. Traditionally, the micro-channel plate (MCP) based detection systems for electrostatic particle spectrometers have been calibrated using the plateau curve technique. In this, a fixed detection threshold is set. The detection system count rate is then measured as a function of MCP voltage to determine the MCP voltage that ensures the count rate has reached a constant value independent of further variation in the MCP voltage. This is achieved when most of the MCP pulse height distribution (PHD) is located at higher values (larger pulses) than the detection system discrimination threshold. This method is adequate in single-channel detection systems and in multi-channel detection systems with very low crosstalk between channels. However, in dense multi-channel systems, it can be inadequate. Furthermore, it fails to fully describe the behavior of the detection system and individually characterize each of its fundamental parameters. To improve this situation, we have developed a detailed phenomenological description of the detection system, its behavior and its signal, crosstalk and noise sources. Based on this, we have devised a new detection system calibration method that enables accurate and repeatable measurement and calibration of MCP gain, MCP efficiency, signal loss due to variation in gain and efficiency, crosstalk from effects both above and below the MCP, noise margin, and stability margin in one single measurement. More precise calibration is highly desirable as the instruments will produce higher quality raw data that will require less post-acquisition data correction using results from in-flight pitch angle distribution measurements and ground calibration measurements. The detection system description and the fundamental concepts of this new calibration method, named threshold scan, will be presented. It will be shown how to derive all the individual detection system parameters and how to choose the optimum detection system operating point. This new method has been successfully applied to achieve a highly accurate calibration of the DESs and DISs of the MMS mission. The practical application of the method will be presented together with the achieved calibration results and their significance. Finally, it will be shown that, with further detailed modeling, this method can be extended for use in flight to achieve and maintain a highly accurate detection system calibration across a large number of instruments during the mission.

detection system↗

SARSAT 121.5/243 MHz technical evaluation

The NOAA 8 SARSAT system performance was tested at 121.5/243 MHz to measure detection probability, detection threshold, location accuracy, ambiguity resolution, and multiple access capacity. Detection probability exceeds 0.95 for a single satellite pass. Detection threshold margin varies from 2 dB (243 MHz, incoherent) to 20 dB (121.5, coherent). Position location error is 20 km 68% of the time. Ambiguity is resolved 75% of the time. The system can locate 10 separate test signals.

Hayes, E. J.↗

A Three-Dimensional Receiver Operator Characteristic Surface Diagnostic Metric

Receiver Operator Characteristic (ROC) curves are commonly applied as metrics for quantifying the performance of binary fault detection systems. An ROC curve provides a visual representation of a detection system s True Positive Rate versus False Positive Rate sensitivity as the detection threshold is varied. The area under the curve provides a measure of fault detection performance independent of the applied detection threshold. While the standard ROC curve is well suited for quantifying binary fault detection performance, it is not suitable for quantifying the classification performance of multi-fault classification problems. Furthermore, it does not provide a measure of diagnostic latency. To address these shortcomings, a novel three-dimensional receiver operator characteristic (3D ROC) surface metric has been developed. This is done by generating and applying two separate curves: the standard ROC curve reflecting fault detection performance, and a second curve reflecting fault classification performance. A third dimension, diagnostic latency, is added giving rise to 3D ROC surfaces. Applying numerical integration techniques, the volumes under and between the surfaces are calculated to produce metrics of the diagnostic system s detection and classification performance. This paper will describe the 3D ROC surface metric in detail, and present an example of its application for quantifying the performance of aircraft engine gas path diagnostic methods. Metric limitations and potential enhancements are also discussed

Simon, Donald L.↗

Orbiter global positioning system design and Ku-band problem investigations, exhibit B, revision 1

The shuttle Ku-band Costas loop lock detector output signal appears to vary about the lock detection threshold (the lock detect flag is on and off) shortly after the carrier acquisition starts. Real time computer simulation was performed to obtain the signal output from the low pass filter of the lock detector. Based on this simulation, it appears that the oscillation of in-lock and out-lock is related to tracking process and is not caused by the sweep acquisition algorithm.

Lindsey, W. C.↗

A Gamma-Ray Burst Trigger Toolkit

The detection rate of a gamma-ray burst detector can be increased by using a count rate trigger with many accumulation times DELTAt and energy bands DELTAE Because a burst's peak flux varies when averaged over different DELTAt and DELTAE the nominal sensitivity (the numerical value of the peak flux) of a trigger system is less important than how much fainter a burst could be at the detection threshold as DELTAt and DELTAE are changed. The relative sensitivity of different triggers can be quantified by referencing the detection threshold back to the peak flux for a fiducial value of DELTAt and DELTA E. This mapping between peak flux values for different sets of DELTAt and DELTAE varies from burst to burst. Quantitative estimates of the burst detection rate for a given detector and trigger system can be based on the observed rate at a measured peak flux value in this fiducial trigger. Predictions of a proposed trigger's burst detection rate depend on the assumed burst population, and these predictions can be wildly in error for triggers that differ significantly from previous missions. I base the fiducial rate on the BATSE observations: 550 bursts per sky above a peak flux of 0.3 ph per square centimeter per second averaged over DELTAt=1.024 sec and DELTAE=50-300 keV. Using a sample of 100 burst lightcurves I find that triggering on any value of DELTAt that is a multiple of 0.064 sec decreases the average threshold peak flux on the 1.024 sec timescale by a factor of 0.6. Extending DELTAE to lower energies includes the large flux of the X-ray background, increasing the background count rate. Consequently a low energy DELTAE is advantageous only for very soft bursts. Whether a large fraction of the population of bright bursts is soft is disputed; the new population of X-ray Flashes is soft but relatively faint.

Band, David L.↗

Node synchronization of viterbi decoders using state metrics

The concept of node synchronization using state metrics is investigated. The branch metrics are integrated over a fixed time interval and the results are compared to the detection threshold. If the threshold is exceeded, the out-of-sync hypothesis is accepted; otherwise, the in-sync hypothesis is accepted. It is shown that the detection threshold can be chosen independent of any particular convolutional code with fixed code rate and constant length if the code has reasonably good bit error rate performance. Three node synchronization schemes are compared: (1) a scheme using the syndrome; (2) a scheme using the frame-sync patterns; and (3) a scheme using the state metrics. At very low signal to noise ratios (SNR), scheme 2 can be faster than scheme 1. For Voyager's rate 1/2 and constraint length 7 convolutional code, this happens for SNRs of less than 0.7 dB. This result is obtained by assuming that the code frame-sync pattern has good aperiodic autocorrelation properties. For a fixed false alarm probability, the sequential detection scheme based on the syndrome is faster than scheme 3 with fixed integration time. A sequential detection technique is needed to improve the speed of scheme 3.

Cheng, U.↗

Temporal variations of the anomalous oxygen component, 1977 - 1984

A survey is of the long term temporal variations of 6.6 to 12 MeV/nucleon anomalous oxygen at 1 AU covering the period 1977 to 1984. This time interval included the recent solar maximum, with the recovery at neutron monitor energies beginning in 1982. During this time interval, 6.6 to 12 MeV/nucleon 0 fluxes decreased by at least a factor of 50, and indeed remained below the instrumental detection threshold after 1979. By late 1984, neutron monitors had recovered to roughly 1979 levels from the 1982 solar maximum, and anomalous O still remained below the detection threshold.

Mason, G. M.↗

Visibility of wavelet quantization noise

The discrete wavelet transform (DWT) decomposes an image into bands that vary in spatial frequency and orientation. It is widely used for image compression. Measures of the visibility of DWT quantization errors are required to achieve optimal compression. Uniform quantization of a single band of coefficients results in an artifact that we call DWT uniform quantization noise; it is the sum of a lattice of random amplitude basis functions of the corresponding DWT synthesis filter. We measured visual detection thresholds for samples of DWT uniform quantization noise in Y, Cb, and Cr color channels. The spatial frequency of a wavelet is r 2-lambda, where r is display visual resolution in pixels/degree, and lambda is the wavelet level. Thresholds increase rapidly with wavelet spatial frequency. Thresholds also increase from Y to Cr to Cb, and with orientation from lowpass to horizontal/vertical to diagonal. We construct a mathematical model for DWT noise detection thresholds that is a function of level, orientation, and display visual resolution. This allows calculation of a "perceptually lossless" quantization matrix for which all errors are in theory below the visual threshold. The model may also be used as the basis for adaptive quantization schemes.

NASA Center ARC↗

On the use of V/V(max) for gamma-ray bursts

As applied to the BATSE observations, the V/V(max) test has shown definitively that gamma-ray bursts are not distributed homogeneously. It is shown that variations in the detection threshold smooth the distribution of V/V(max) values, and consequently this distribution should not be used to determine the nature of the source inhomogeneity. Models fitted to the V/V(max) distribution assuming a constant detection threshold are quantitatively incorrect; the true source density has a more extreme radial decrease than previously found. Models should be fitted to the observed distribution of peak burst photon fluxes corrected for detection incompleteness.

Band, David↗