Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Prospects for measuring the time variation of astrophysical neutrino sources at dark matter detectors

We study the prospects for measuring the time variation of solar and atmospheric neutrino fluxes at future large-scale xenon and argon dark matter detectors. For solar neutrinos, a yearly time variation arises from the eccentricity of Earth’s orbit and, for charged current interactions, from a smaller energy-dependent day-night variation due to flavor regeneration as neutrinos travel through Earth. For a 100-ton xenon detector running for ten years with a xenon-136 fraction of ≲ 0.1 % , in the electron recoil channel a time-variation amplitude of about 0.8% is detectable with a power of 90% and the level of significance of 10%. This is sufficient to detect time variation due to eccentricity, which has amplitude of ∼ 3 % . In the nuclear recoil channel, the detectable amplitude is about 10% under current detector resolution and efficiency conditions, and this generally reduces to about 1% for improved detector resolution and efficiency, the latter of which is sufficient to detect time variation due to eccentricity. Our analysis assumes both known and unknown periods. We provide scalings to determine the sensitivity to an arbitrary time-varying amplitude as a function of detector parameters. Identifying the time variation of the neutrino fluxes will be important for distinguishing neutrinos from dark matter signals and other detector-related backgrounds and extracting properties of neutrinos that can be uniquely studied in dark matter experiments. Published by the American Physical Society 2024

Zhuang, Yi (ORCID:0000000277138724)↗

Particle track classification using quantum associative memory

Pattern recognition algorithms are commonly employed to simplify the challenging and necessary step of track reconstruction in sub-atomic physics experiments. Aiding in the discrimination of relevant interactions, pattern recognition seeks to accelerate track reconstruction by isolating signals of interest. In high collision rate experiments, such algorithms can be particularly crucial for determining whether to retain or discard information from a given interaction even before the data is transferred to tape. As data rates, detector resolution, noise, and inefficiencies increase, pattern recognition becomes more computationally challenging, motivating the development of higher efficiency algorithms and techniques. Quantum associative memory is an approach that seeks to exploits quantum mechanical phenomena to gain advantage in learning capacity, or the number of patterns that can be stored and accurately recalled. Here, we study quantum associative memory based on quantum annealing and apply it to the particle track classification. We focus on discrimination models based on Ising formulations of quantum associative memory model (QAMM) recall and quantum content-addressable memory (QCAM) recall. We characterize classification performance of these approaches as a function detector resolution, pattern library size, and detector inefficiencies, using the D-Wave 2000Q processor as a testbed. Discrimination criteria is set using both solution-state energy and classification labels embedded in solution states. We find that energy-based QAMM classification performs well in regimes of small pattern density and low detector inefficiency. In contrast, state-based QCAM achieves reasonably high accuracy recall for large pattern density and the greatest recall accuracy robustness to a variety of detector noise sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of high resolution imaging detectors for x ray astronomy

This final report summarizes our past activities and discusses the work performed over the period of 1 April 1990 through 1 April 1991 on x-ray optics, soft x-ray (0.1 - 10 KeV) imaging detectors, and hard x-ray (10 - 300 KeV) imaging detectors. If microchannel plates (MCPs) can be used to focus x-rays with a high efficiency and good angular resolution, they will revolutionize the field of x-ray optics. An x-ray image of a point source through an array of square MCP pores compared favorably with our ray tracing model for the MCP. Initial analysis of this image demonstrates the feasibility of MCPs for soft x-rays. Our work continues with optimizing the performance of our soft x-ray MCP imaging detectors. This work involves readout technology that should provide improved MCP readout devices (thin film crossed grid, curved, and resistive sheets), defect removal in MCPs, and photocathode optimization. In the area of hard x-ray detector development we have developed two different techniques for producing a CsI photocathode thickness of 10 to 100 microns, such that it is thick enough to absorb the high energy x-rays and still allow the photoelectrons to escape to the top MCP of a modified soft x-ray imaging detector. The methods involve vacuum depositing a thick film of CsI on a strong back, and producing a converter device that takes the place of the photocathode.

Murray, S. S.↗

Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground

We present limits on spin-independent dark matter-nucleon interactions using a 10.6 g silicon athermal phonon detector with a baseline energy resolution of 4.92 +/- 0.01 eV. This exclusion analysis sets the most stringent dark matter-nucleon cross-section limits for masses from 87--140 MeV/c^2 , with a raw exposure of 9.9 g d acquired at an above-ground facility. This work illustrates the scientic potential of athermal phonon sensors with eV-scale energy resolution for future dark matter searches.

Alkhatib, I↗

A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level

Abstract The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a photocathode operating in a semi-transparent mode and a Micromegas amplification structure. The first proof of concept single-channel prototype was able to achieve a time resolution below 25 ps. One of the crucial aspects in the development of precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm 2 suffered from degraded timing resolution due to the non-uniformity of the preamplification gap thickness. A new 100 cm 2 detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over the measured pads and a time resolution below 25 ps. More recent measurements with a thinner drift gap detector module and newly developed RF pulse amplifiers show that the pad centre resolution can be enhanced to the level of 17 ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.

Utrobicic, A.↗

Optimization of X-ray Absorbers for High-Resolution TES Detectors in NewATHENA X-IFU

NewATHENA’s X-ray Integral Field Unit (X-IFU) uses a large-format array of Transition Edge Sensor (TES) microcalorimeters coupled with absorbers made of gold and bismuth providing 4 eV FWHM resolution up to 7 keV in the 0.2- 12 keV band. X-ray absorbers must be thick enough for photon absorption, maintain low heat capacity for energy resolution, and have good thermalization properties. The X-IFU requires total Quantum Efficiency (QE) of 96%, 87%, and 63% at 1, 7, and 9.5 keV, respectively. Optimal thicknesses are 1.05 µm gold and 5.5 µm bismuth to achieve 0.731 pJ/K at 90 mK and 87% QE at 7 keV. While typical TES absorbers are 3-4 µm thick, producing the required 5.5 µm Bi absorbers via standard electroplating creates enlarged grains and surface roughness. The increased roughness and grain size variability produced with our standard recipe have resulted in instances of 1) low energy spectral tails 2) spectral broadening of the energy resolution and 3) thermal shorts between pixels when a large grain bridges the gap between absorbers. In this study, we have introduced a new fabrication process and altered the morphology of the thick Bi through changes in the electroplating process. The process changes are intended to address all three issues as well as reduce particulate contamination observed on the finished detector arrays.

Absorber↗

High Spatial Resolution Investigations of Microchannel Plate Imaging Properties for UV Detectors

Microchannel plate (MCP) photon counting detectors are currently being used with great success on many of the recent NASA/ESA ultraviolet (UV) astrophysics missions that make observations in the 1OO A - 1600 A range. These include HUT, the Wide Field Camera on ROSAT, EUVE, ALEXIS, ORFEUS, and SOHO. These devices have also been chosen to fly on future UV astrophysics missions such as FUSE, FUVITA, IMAGE, and both the HST STIS and Advanced Camera instruments. During the period of this award we have fabricated a dual-chamber vacuum test facility to carry out laboratory testing of detector resolution, image stability and linearity, and flat field performance to enable us to characterize the performance of MCPs and their associated read-out architectures. We have also fabricated and tested a laboratory 'test-bed' delay line detector, which can accommodate MCP's with a wide range of formats and run at high data rates, to continue our studies of MCP image fixed pattern noise, and particularly for new small pore MCP's which have recently come onto the market. These tests were mainly focussed on the assessment of cross delay-line (XDL) and double delay line (DDL) anode read-out schemes, with particular attention being focussed on flat-field and spatial resolution performance.

Siegmund, Oswald↗

Performance characterization of the Radionuclide Aerosol Sampler/Analyzer air sampler during a high-activity release event

The performance of the Radionuclide Aerosol Sampler/Analyzer (RASA) under high-activity conditions has been evaluated to maintain and protect the operations of International Monitoring System (IMS) radionuclide stations. Station measurements following the Fukushima Daichi accident of 11 March 2011 have been combined with laboratory measurements to understand how the quality of the measurements made using the RASA High-Purity Germanium (HPGe) gamma-spectrometer are impacted by increased sample activity and detector dead-time. Detector saturation has been identified to occur at a count rate of 175,000 counts s-1, at which level there are significant impacts to the sample live-time and detector resolution in addition to a system contamination risk. To safeguard against these effects, a dead-time limit of 16.6% is proposed that could be maintained by monitoring the activity collecting on the filter using a Cadmium Zinc Telluride (CZT) detector installed into the particulate collection area of the RASA. This limit would ensure that the IMS technical specifications for measurement time (> 20 h) and detector resolution (2.5 keV at 1332 keV) are met. The CZT would dynamically control the RASA air flow to limit the collection of particulate activity beneath the HPGe dead-time threshold and would also provide measurements useful for CTBT verification purposes and dose assessments.

Burnett, Jonathan L.↗

A high resolution semiconductor detector for applications in space

Nuclear radiation detectors with volumes of approximately 1 cu cm was fabricated from single crystals of germanium-silicon alloy containing as much as 20 weight percent germanium. The properties of these detectors were investigated and will be discussed. Tests reveal that the gamma ray photoelectric peak efficiency of an alloy detector with only 12 weight percent germanium is approximately 4 times that of a silicon detector of equal volume. The room temperature roomure appears to be a good possibility. Storage for long periods at room temperature does not seem to adversely affect these devices. The results of preliminary radiation damage experiments suggest that the alloy detectors possess a radiation damage resistance far greater than that of silicon.

Alexander, P.↗

High resolution Cherenkov detectors for cosmic ray isotope experiment

Cerenkov detectors are used to measure the velocity of particles in configurations designed to study the isotopic composition of galactic cosmic rays. The geometrical properties of the detector are outlined. Monte-Carlo simulations of photon propagation in a diffusive detector were undertaken. The scattering properties of diffusively reflecting white paint and of surface treatments for the radiator material were measured. It is found that the absorption of light in the radiator is an important light loss mechanism. The simulations are used to find optimal mapping techniques and data reduction strategies. The application of these techniques are discussed with respect to the large area isotopic composition experiment (ALICE) Cerenkov detector.

Acharya, B. S.↗

Intrinsic Line Shape Measurements of the XRS Instrument on Astro-E2

The XRS instrument on the Astro-E2 observatory contains a substantially improved microcalorimeter array over the Astro-E mission. In addition to roughly a factor of 2 improvement in the detector resolution at 6 keV, the detector response is shown to be almost perfectly gaussian. We have made measurements of the detector response of the flight instrument, using a double crystal monochrometer at 4 and 8 keV, a 55-Fe internal conversion source, and x-ray induced fluorescence from a number of targets including Ti, Cu, and GaAs. The detector response has been measured to be entirely gaussian to at least 2 orders of magnitude down from the peak of the line or line complex. This is in sharp contrast to the results from the XRS on Astro-E where many channels exhibited excess counts on the high energy side of the spectral lines. Here we present details of the line shape measurement as well as the detector response as measured during the XRS ground calibration including details of the line fits and line models.

Porter, F. Scott↗

Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector

This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axionlike particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 g Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 g-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section σ ¯ e is constrained for dark matter masses from 0.5 to 10 4 MeV / c 2 ; in the mass range from 1.2 to 50 eV / c 2 the dark photon kinetic mixing parameter ϵ and the axioelectric coupling constant g a e are constrained. The minimum 90% confidence-level upper limits within the above-mentioned mass ranges are σ ¯ e = 8.7 × 10 - 34 cm 2 , ϵ = 3.3 × 10 - 14 , and g a e = 1.0 × 10 - 9 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration and Performance of Germanium High Voltage Detectors for SuperCDMS SNOLAB

As SuperCDMS SNOLAB is getting ready to search for low mass dark matter particles, using cryogenic Ge and Si detectors, a set of six of the new SuperCDMS High Voltage (HV) detectors (four Ge and two Si) were tested in the Cryogenic Underground TEst facility (CUTE) at SNOLAB. This provided the first opportunity to gain experience with this new detector type and assess their performance thoroughly under low background conditions. Here we describe the SuperCDMS HV detector concept and discuss some of the newly developed analysis methods and approaches. Focusing on the Ge detectors, we investigate the detector performance under voltage bias (up to 90 V), exercise the low energy (keV to sub-keV range) calibration based on the electron capture peaks generated by the decay of $^{71}$Ge, assess the detector resolution, and demonstrate the unexpected (and encouraging) ability of these detectors to also measure high energy interactions in the hundreds of keV range with good resolution (better than 3% at 356 keV).

Albakry, M. F. [British Columbia U.; TRIUMF]↗

Development of liquid xenon detectors for gamma ray astronomy

The application of liquid xenon in high-resolution detectors for gamma-ray astronomy is being investigated. Initial results from a pulse-shape analysis of ionization signals in a liquid-xenon gridded chamber indicate that it is possible to achieve the necessary liquid purity for the transport of free electrons with simple techniques. The energy resolution has been measured as a function of applied electric field, using electrons and gamma-rays from a 207Bi source. At a field of 12 kV/cm the noise-substracted energy resolution of the dominant 569-keV gamma-ray line is 34 keV FWHM (full width at half maximum). This value is mostly determined by recombination of electron-ion pairs on delta-electron tracks.

Aprile, Elena↗

Isotopic gamma lines for identification of shielding materials

Identifying the constituting materials of concealed objects is crucial in a wide range of sectors, such as medical imaging, geophysics, nonproliferation, national security investigations, and so on. Existing methods face limitations, particularly when multiple materials are involved or when there are challenges posed by scattered radiation and large areal mass. Here we introduce a novel brute-force statistical approach for material identification using high spectral resolution detectors, such as HPGe. The method relies upon updated semianalytic formulae for computing uncollided flux from source of gamma radiation, shielded by a sequence of nested spherical or cylindrical materials. These semianalytical formulae make possible rapid flux estimation for material characterization via combinatorial search through all possible combinations of materials, using a high-resolution HPGe counting detector. An important prerequisite for the method is that the geometry of the objects is known (for example, from X-ray radiography). We demonstrate the viability of this material characterization technique in several use cases with both simulated and experimental data in spherical geometry.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of online pulse-finding algorithms for the Mu2e Stopping Target Monitor and an evaluation of the signal to background ratio for the Mu2e stopped-muon rate determination

This thesis presents a determination of the acceptance of the Mu2e Stopping Target Monitor (STM) detector for both signal and background events. The rate of X-rays of a specific energy in the STM is used to determine the rate of stopped muons in the aluminium stopping target, which is used as the normalisation for all Mu2e measurements, particularly the branching ratio for a charged lepton flavour violating (cLFV) process. The acceptance for the 347\,keV $2p-1s$ aluminium signal X-ray is determined to be $(8.03 \pm 0.05) \times 10^{-10}$\,cm$^{-2}$ and the acceptance for the background photons (at 347\,keV) to be $(3.19 \pm 0.21) \times 10^{-8}$\,cm$^{-2}$. This results in a signal-to-background ratio of approximately two which is significantly higher than had previously been estimated. These signal-to-background rates are used to determine the time required to achieve a statistical uncertainty of 10\% on the number of 347\,keV X-rays as a function of the detector resolution and back ground rate. For a resolution of 2\,keV, and the background rate determined in this thesis, approximately one minute of data is required. The three corrections needed to be applied to the measured 347\,keV rate to determine the rate of stopped muons are also determined and potential sources of bias arising from the background shape, background fit range and energy calibration are investigated and found to be insignificant. The raw energy of the particles in the STM detector comes from a 16-bit ADC digitising at $\sim 300$\,MHz. It is not possible to store all the raw digitisations and online algorithms have been developed to rapidly select pulses in the detector and reconstruct their energy. The performance of these algorithms has been characterised with simulated data as a function of detector rate and resolution and optimum operating points for the algorithms have been defined. The integrity of the algorithms has also been demonstrated and characterised on test-beam data at high r ates and with radioactive sources at low rates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗