Search NASA⌕ Search

SEARCH · Search NASA

Results for “deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Characterization of cardiac quiescence from retrospective cardiac computed tomography using a correlation-based phase-to-phase deviation measure

Purpose: Accurate knowledge of cardiac quiescence is crucial to the performance of many cardiac imaging modalities, including computed tomography coronary angiography (CTCA). To accurately quantify quiescence, a method for detecting the quiescent periods of the heart from retrospective cardiac computed tomography (CT) using a correlation-based, phase-to-phase deviation measure was developed. Methods: Retrospective cardiac CT data were obtained from 20 patients (11 male, 9 female, 33–74 yr) and the left main, left anterior descending, left circumflex, right coronary artery (RCA), and interventricular septum (IVS) were segmented for each phase using a semiautomated technique. Cardiac motion of individual coronary vessels as well as the IVS was calculated using phase-to-phase deviation. As an easily identifiable feature, the IVS was analyzed to assess how well it predicts vessel quiescence. Finally, the diagnostic quality of the reconstructed volumes from the quiescent phases determined using the deviation measure from the vessels in aggregate and the IVS was compared to that from quiescent phases calculated by the CT scanner. Three board-certified radiologists, fellowship-trained in cardiothoracic imaging, graded the diagnostic quality of the reconstructions using a Likert response format: 1 = excellent, 2 = good, 3 = adequate, 4 = nondiagnostic. Results: Systolic and diastolic quiescent periods were identified for each subject from the vessel motion calculated using the phase-to-phase deviation measure. The motion of the IVS was found to be similar to the aggregate vessel (AGG) motion. The diagnostic quality of the coronary vessels for the quiescent phases calculated from the aggregate vessel (P{sub AGG}) and IVS (P{sub IV} {sub S}) deviation signal using the proposed methods was comparable to the quiescent phases calculated by the CT scanner (P{sub CT}). The one exception was the RCA, which improved for P{sub AGG} for 18 of the 20 subjects when compared to P{sub CT} (P{sub CT} = 2.48; P{sub AGG} = 2.07, p = 0.001). Conclusions: A method for quantifying the motion of specific coronary vessels using a correlation-based, phase-to-phase deviation measure was developed and tested on 20 patients receiving cardiac CT exams. The IVS was found to be a suitable predictor of vessel quiescence. The diagnostic quality of the quiescent phases detected by the proposed methods was comparable to those calculated by the CT scanner. The ability to quantify coronary vessel quiescence from the motion of the IVS can be used to develop new CTCA gating techniques and quantify the resulting potential improvement in CTCA image quality.

60 APPLIED LIFE SCIENCES↗

Power-Smoothing Scheme of a DFIG Using the Adaptive Gain Depending on the Rotor Speed and Frequency Deviation

In an electric power grid that has a high penetration level of wind, the power fluctuation of a large-scale wind power plant (WPP) caused by varying wind speeds deteriorates the system frequency regulation. This paper proposes a power-smoothing scheme of a doubly-fed induction generator (DFIG) that significantly mitigates the system frequency fluctuation while preventing over-deceleration of the rotor speed. The proposed scheme employs an additional control loop relying on the system frequency deviation that operates in combination with the maximum power point tracking control loop. To improve the power-smoothing capability while preventing over-deceleration of the rotor speed, the gain of the additional loop is modified with the rotor speed and frequency deviation. The gain is set to be high if the rotor speed and/or frequency deviation is large. In conclusion, the simulation results based on the IEEE 14-bus system clearly demonstrate that the proposed scheme significantly lessens the output power fluctuation of a WPP under various scenarios by modifying the gain with the rotor speed and frequency deviation, and thereby it can regulate the frequency deviation within a narrow range.

17 WIND ENERGY↗

Real-Time Pretreatment Review Limits Unacceptable Deviations on a Cooperative Group Radiation Therapy Technique Trial: Quality Assurance Results of RTOG 0933

Purpose: RTOG 0933 was a phase II trial of hippocampal avoidance during whole brain radiation therapy for patients with brain metastases. The results demonstrated improvement in short-term memory decline, as compared with historical control individuals, and preservation of quality of life. Integral to the conduct of this trial were quality assurance processes inclusive of pre-enrollment credentialing and pretreatment centralized review of enrolled patients. Methods and Materials: Before enrolling patients, all treating physicians and sites were required to successfully complete a “dry-run” credentialing test. The treating physicians were credentialed based on accuracy of magnetic resonance imaging–computed tomography image fusion and hippocampal and normal tissue contouring, and the sites were credentialed based on protocol-specified dosimetric criteria. Using the same criteria, pretreatment centralized review of enrolled patients was conducted. Physicians enrolling 3 consecutive patients without unacceptable deviations were permitted to enroll further patients without pretreatment review, although their cases were reviewed after treatment. Results: In all, 113 physicians and 84 sites were credentialed. Eight physicians (6.8%) failed hippocampal contouring on the first attempt; 3 were approved on the second attempt. Eight sites (9.5%) failed intensity modulated radiation therapy planning on the first attempt; all were approved on the second attempt. One hundred thirteen patients were enrolled in RTOG 0933; 100 were analyzable. Eighty-seven cases were reviewed before treatment; 5 (5.7%) violated the eligibility criteria, and 21 (24%) had unacceptable deviations. With feedback, 18 cases were approved on the second attempt and 2 cases on the third attempt. One patient was treated off protocol. Twenty-two cases were reviewed after treatment; 1 (4.5%) violated the eligibility criteria, and 5 (23%) had unacceptable deviations. Conclusions: Although >95% of the cases passed the pre-enrollment credentialing, the pretreatment centralized review disqualified 5.7% of reviewed cases, prevented unacceptable deviations in 24% of reviewed cases, and limited the final unacceptable deviation rate to 5%. Thus, pretreatment review is deemed necessary in future hippocampal avoidance trials and is potentially useful in other similarly challenging radiation therapy technique trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A high precision instrument to measure angular and binocular deviation introduced by aircraft windscreens by using a shadow casting technique

Objects viewed through transparent sheets with residual non-parallelism and irregularity appear shifted and distorted. This distortion is measured in terms of angular and binocular deviation of an object viewed through the transparent sheet. The angular and binocular deviations introduced are particularly important in the context of aircraft windscreens and canopies as they can interfere with decision making of pilots especially while landing, leading to accidents. In this work, we have developed an instrument to measure both the angular and binocular deviations introduced by transparent sheets. This instrument is especially useful in the qualification of aircraft windscreens and canopies. It measures the deviation in the geometrical shadow cast by a periodic dot pattern trans-illuminated by the distorted light beam from the transparent test specimen compared to the reference pattern. Accurate quantification of the shift in the pattern is obtained by cross-correlating the reference shadow pattern with the specimen shadow pattern and measuring the location of the correlation peak. The developed instrument is handy to use and computes both angular and binocular deviation with an accuracy of less than {+-}0.1 mrad ( Almost-Equal-To 0.036 mrad) and has an excellent repeatability with an error of less than 2%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Linear maps preserving maximal deviation and the Jordan structure of quantum systems

In the algebraic approach to quantum theory, a quantum observable is given by an element of a Jordan algebra and a state of the system is modelled by a normalized positive functional on the underlying algebra. Maximal deviation of a quantum observable is the largest statistical deviation one can obtain in a particular state of the system. The main result of the paper shows that each linear bijective transformation between JBW algebras preserving maximal deviations is formed by a Jordan isomorphism or a minus Jordan isomorphism perturbed by a linear functional multiple of an identity. It shows that only one numerical statistical characteristic has the power to determine the Jordan algebraic structure completely. As a consequence, we obtain that only very special maps can preserve the diameter of the spectra of elements. Nonlinear maps preserving the pseudometric given by maximal deviation are also described. The results generalize hitherto known theorems on preservers of maximal deviation in the case of self-adjoint parts of von Neumann algebras proved by Molnar.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

How the “main condition” of phase stability can explain the effect of the velocity deviation of secondary electrons in DC-biased single-sided multipactors

In this work, a “main condition” for phase stability has been employed to investigate the effects of the velocity deviation of the electrons in DC-biased single-sided multipactors (MPs). In a previous study [M. Mostajeran, Phys. Plasmas 21, 053108 (2014)], a stability equation was derived, where the secondary electron was assumed to have zero initial velocity and the phase deviation from the resonant phase was considered. In this work, both deviations in phase and velocity from the resonant condition are taken into account, assuming nonzero initial velocity for the secondary electrons. Using the main condition for stability, it is shown that MP discharge can rise in situations, where large velocity deviations from initial velocity and large phase deviations from resonant phase exist. This is contrary to what can be predicted on the basis of the “simple stability condition.” This result is further confirmed by numerical simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The velocity deviations of secondary electrons and the main condition of phase stability in two-sided multipactors

The conditions for secondary emission of electrons and the occurrence of discharge have been analyzed in detail with a plane-parallel model. According to the traditional theory of a resonance discharge (referred to as “simple resonance theory”), the velocity deviation of secondary electrons has no effect on multipactor (MP) zones. In this work, the effect of such deviations from resonance value in two-sided multipactors has been investigated using a different approach. In a previous study [M. Mostajeran and M. Lamehi Rachti, J. Instrum. 5, P08003 (2010)], a stability equation was derived considering only the phase deviation from the resonant phase. Here, the approach used in that paper has been extended to include velocity deviations as well. It is shown that phase and velocity deviations, which may not be considered small, support MP zones. Theoretical calculations are then compared with numerical results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Large Angle Deviation in Grid-Following IBRs Upon Grid Voltage Dip

In the 2021 Texas Odessa large-scale solar PV tripping events, phase-locked-loop (PLL) loss of synchronism is identified as a major cause of solar PV tripping. When solar PVs detected a large phase angle deviation (e.g., 10 degrees), tripping commands were initiated. Here, the large phase angle deviation was triggered by a transmission line fault 200 miles away, which in turn led to approximately 30% voltage drop in the 345-kV system. This paper offers a plausible reason why grid-following inverter-based resources (IBRs) may experience a large angle deviation upon grid voltage dip. Critical operating conditions contributing to such phenomena are identified via analysis and their effects are demonstrated using electromagnetic transient (EMT) simulation. Furthermore, the effect of converter control, e.g., grid-following control vs. grid-forming control, is examined. It is found from EMT simulation results that frequency and voltage control are helpful in mitigating angle deviation. Furthermore, linear block diagrams are derived to examine why frequency control can effectively suppress large angle deviation.

14 SOLAR ENERGY↗

Secondary flow spanwise deviation model for the stators of NASA middle compressor stages

A model of the spanwise variation of deviation for stator blades is presented. Deviation is defined as the difference between the passage mean flow angle and the metal angle at the outlet of a blade element of an axial compressor stage. The variation of deviation is taken as the difference above or below that predicted by blade element, (i.e., two-dimensional) theory at any spanwise location. The variation of deviation is dependent upon the blade camber, solidity and inlet boundary layer thickness at the hub or tip end-wall, and the blade channel aspect ratio. If these parameters are known or can be calculated, the model provides a reasonable approximation of the spanwise variation of deviation for most compressor middle stage stators operating at subsonic inlet Mach numbers.

Roberts, W. B.↗

The Standard Deviation of Launch Vehicle Environments

Statistical analysis is used in the development of the launch vehicle environments of acoustics, vibrations, and shock. The standard deviation of these environments is critical to accurate statistical extrema. However, often very little data exists to define the standard deviation and it is better to use a typical standard deviation than one derived from a few measurements. This paper uses Space Shuttle and expendable launch vehicle flight data to define a typical standard deviation for acoustics and vibrations. The results suggest that 3dB is a conservative and reasonable standard deviation for the source environment and the payload environment.

Yunis, Isam↗

Moderate deviations-based importance sampling for stochastic recursive equations

Subsolutions to the Hamilton–Jacobi–Bellman equation associated with a moderate deviations approximation are used to design importance sampling changes of measure for stochastic recursive equations. Analogous to what has been done for large deviations subsolution-based importance sampling, these schemes are shown to be asymptotically optimal under the moderate deviations scaling. Here, we present various implementations and numerical results to contrast their performance, and also discuss the circumstances under which a moderate deviation scaling might be appropriate.

97 MATHEMATICS AND COMPUTING↗

Dynamical Large Deviations of Two-Dimensional Kinetically Constrained Models Using a Neural-Network State Ansatz

We use a neural-network ansatz originally designed for the variational optimization of quantum systems to study dynamical large deviations in classical ones. We use recurrent neural networks to describe the large deviations of the dynamical activity of model glasses, kinetically constrained models in two dimensions. We present the first finite size-scaling analysis of the large-deviation functions of the two-dimensional Fredrickson-Andersen model, and explore the spatial structure of the high-activity sector of the South-or-East model. These results provide a new route to the study of dynamical large-deviation functions, and highlight the broad applicability of the neural-network state ansatz across domains in physics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of Natural Variability on the Use of Standard Deviation to Represent Measurement Uncertainties in Atmospheric Composition Studies

Measurement uncertainty is defined as a “non-negative parameter characterizing the dispersion of the quantity values being attributed to a measurand”. It is most common that the uncertainties of GAW hourly measurements, such as greenhouse gas measurements, are reported as standard deviations derived from individual sampling at a higher time resolution (e.g., 1 min). In contrast, the uncertainties of GAW measurements of reactive gases and aerosol properties are reported in percentiles covering the same probability. A quick look at hourly CO 2 data from Cape Grim, Australia yielded some interesting findings: the hourly standard deviation is, on average, more than a factor of 10 higher for the measurements under non-background conditions (over 50% observations), while the difference in average CO 2 amount fraction was less than 2 ppm. The dramatic contrast cannot be explained by the difference in measurement uncertainties, but can largely be attributed the natural variability, or episodic ambient CO 2 variation reflecting changes in meteorological conditions or emissions. These initial findings motivated a more in-depth analysis of the ground-based measurements of trace gases and aerosol properties. This analysis will be using continuous 1 min ground site observations to construct time averaged statistical indicators to evaluate whether the standard deviation is adequate to represent the dispersion, especially under marked influence by natural variability. The suitability of this representation can be determined by examining the difference between the standard deviation and percentiles encompassing the same probability. We will examine time intervals of 1 hour, 3 hours, and 24 hours, with the latter time intervals chosen to match those commonly used in model assessments. We will also investigate how natural variability can alter the probability distribution of the measurands and how adequate the quadrature propagation of uncertainties is under these conditions. The results will include several trace gases (e.g., CO 2 , CO, O 3 , and NO 2 ) with a range of measurement techniques (e.g., PANDORA, in situ), atmospheric lifetimes, and aerosol properties (e.g. scattering coefficient). The findings from this analysis should provide some useful feedback on the best practices for uncertainty reporting.

Measurement Uncertainty↗

Vacuum stability bounds on Higgs coupling deviations in the absence of new bosons

We analyze the constraints imposed by Higgs vacuum stability on models with new fermions beyond the Standard Model. We focus on the phenomenology of Higgs couplings accessible at the Large Hadron Collider. New fermions that affect Higgs couplings lead to vacuum instability of the Higgs potential. Above the scale of vacuum instability, bosonic states must stabilize the potential, implying a cut-off to the pure fermion model. Conservatively tuning the models to produce the maximal cut-off for a given Higgs coupling effect, we show that observing a deviation in the Htt, H-diphoton, or H-digluon coupling, larger than 20%, would require that new bosons exist in order to stabilize the Higgs potential below about 100 TeV. For generic parameter configurations, and unless the new fermions are made as light as they can possibly be given current experimental constraints, observing a 10% deviation in any of these couplings would suggest an instability cut-off below 10-100 TeV. Similarly, if new bosons are absent up to a high scale, then a deviation in the Hbb or Hττ coupling, larger than about 20%, should be accompanied by a sizable deviation in the Zbb or Zττ couplings that can be conclusively tested with electroweak precision measurements at planned lepton colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Density Large Deviations for Multidimensional Stochastic Hyperbolic Conservation Laws

We investigate the density large deviation function for a multidimensional conservation law in the vanishing viscosity limit, when the probability concentrates on weak solutions of a hyperbolic conservation law. When the mobility and diffusivity matrices are proportional, i.e. an Einstein-like relation is satisfied, the problem has been solved in Bellettini and Mariani (Bull Greek Math Soc 57:31–45, 2010). When this proportionality does not hold, we compute explicitly the large deviation function for a step-like density profile, and we show that the associated optimal current has a non trivial structure. We also derive a lower bound for the large deviation function, valid for a more general weak solution, and leave the general large deviation function upper bound as a conjecture.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Flux Large Deviations of Independent and Reacting Particle Systems, with Implications for Macroscopic Fluctuation Theory

We consider a system of independent particles and a system of reacting particles on a discrete state space. For the independent case, we rigorously prove a dynamic large-deviation principle for the empirical measure-integrated flux pair, taking the one-way fluxes rather than net fluxes into account. We prove the large deviations under deterministic initial conditions, and under random initial conditions satisfying a large-deviation principle. We formally calculate similar one-way flux large deviations for the more general reacting particles case. Next, we use these results to derive a number of principles from Macroscopic Fluctuation Theory like time-reversal principles and generalised gradient structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of Patient Residual Deviation and Its Impact on Dose Distribution for Proton Radiotherapy

The residual deviations after final patient repositioning based on bony anatomy and the impact of such deviations on the proton dose distributions was investigated. Digitally reconstructed radiographs (DRRs) and kilovoltage (kV) 'portal verification' images from 10 patients treated with passively scattered proton radiotherapy was used to estimate the residual deviation. These changes were then applied to the location of isocenter points that, in effect, moved the isocenter relative to the apertures and compensators. A composite verification plan was obtained and compared with the original clinical treatment plan to evaluate any changes in dose distributions. The residual deviations were fitted to a Gaussian distribution with {mu} = -0.9 {+-} 0.1 mm and {sigma} = 2.55 {+-} 0.07 mm. The dose distribution showed under- and overcovered dose spots with complex dose distributions both in the target volumes and in the organs at risk. In some cases, this amounts to 63.5% above the intended clinical plan. Although patient positioning is carefully verified before treatment delivery and setup uncertainties are accounted for by using compensator smearing and aperture margins, a residual shift in a patient's position can considerably affect the dose distribution.

61 RADIATION PROTECTION AND DOSIMETRY↗

Deviational simulation of phonon transport in graphene ribbons with ab initio scattering

We present a deviational Monte Carlo method for solving the Boltzmann-Peierls equation with ab initio 3-phonon scattering, for temporally and spatially dependent thermal transport problems in arbitrary geometries. Phonon dispersion relations and transition rates for graphene are obtained from density functional theory calculations. The ab initio scattering operator is simulated by an energy-conserving stochastic algorithm embedded within a deviational, low-variance Monte Carlo formulation. The deviational formulation ensures that simulations are computationally feasible for arbitrarily small temperature differences, while the stochastic treatment of the scattering operator is both efficient and exhibits no timestep error. The proposed method, in which geometry and phonon-boundary scattering are explicitly treated, is extensively validated by comparison to analytical results, previous numerical solutions and experiments. It is subsequently used to generate solutions for heat transport in graphene ribbons of various geometries and evaluate the validity of some common approximations found in the literature. Our results show that modeling transport in long ribbons of finite width using the homogeneous Boltzmann equation and approximating phonon-boundary scattering using an additional homogeneous scattering rate introduces an error on the order of 10% at room temperature, with the maximum deviation reaching 30% in the middle of the transition regime.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗