Search NASA⌕ Search

SEARCH · Search NASA

Results for “diameter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Further development of chemical vapor deposition process for production of large diameter carbon-base monofilaments

The development of large diameter carbon-base monofilament in the 50 micron to 250 micron diameter range using the chemical vapor deposition process is described. The object of this program was to determine the critical process variables which control monofilament strength, monofilament modulus, and monofilament diameter. It was confirmed that wide scatter in the carbon substrate strength is primarily responsible for the scatter in the monofilament strength. It was also shown through etching experiments that defective substrate surface conditions which can induce low strength modular growth in the monofilament layers are best controlled by processing improvements during the synthesis of the substrate. Modulus was found to be linearily proportional to monofilament boron content. Filament modulus was increased to above 27.8MN/sq cm but only by a considerable increase in monofilament boron content to 60 wt. % or more. Monofilament diameter depended upon dwell time in the synthesis apparatus. A monofilament was prepared using these findings which had the combined properties of a mean U.T.S. of 398,000 N/sq cm, a modulus of 18.9 MN/sq cm (24,000,000 psi), and a diameter of 145 microns. Highest measured strength for this fiber was 451,000 N/sq cm (645,000 psi).

Hough, R. L.↗

Radiometric diameters for an additional 22 asteroids

Ten-micron radiometry of 24 asteroids, 22 of which have not previously had their diameters and albedos determined, is presented. The magnitudes of the objects ranged from -0.35 to +5.35 and 13 of them had diameters smaller than 100 km. They ranged in albedo from 0.024 to 0.28, and the 22 previously unstudied objects included 10 C asteroids, seven S asteroids, three U asteroids, and two unknown. In the diameter-albedo plane, ten of the asteroids studied clustered near albedo 0.03 and diameter 100-200 km, in a region previously occupied by only seven asteroids but where Chapman et al. (1975) predicted many objects would be identified upon sampling those fainter than V equals about 12. The new data suggest that there are substantial numbers of S asteroids with diameter less than 100 km in the inner part of the belt.

Morrison, D.↗

Wind tunnel test of a variable-diameter tiltrotor (VDTR) model

This report documents the results from a wind tunnel test of a 1/6th scale Variable Diameter Tiltrotor (VDTR). This test was a joint effort of NASA Ames and Sikorsky Aircraft. The objective was to evaluate the aeroelastic and performance characteristics of the VDTR in conversion, hover, and cruise. The rotor diameter and nacelle angle of the model were remotely changed to represent tiltrotor operating conditions. Data is presented showing the propulsive force required in conversion, blade loads, angle of attack stability and simulated gust response, and hover and cruise performance. This test represents the first wind tunnel test of a variable diameter rotor applied to a tiltrotor concept. The results confirm some of the potential advantages of the VDTR and establish the variable diameter rotor a viable candidate for an advanced tiltrotor. This wind tunnel test successfully demonstrated the feasibility of the Variable Diameter rotor for tilt rotor aircraft. A wide range of test points were taken in hover, conversion, and cruise modes. The concept was shown to have a number of advantages over conventional tiltrotors such as reduced hover downwash with lower disk loading and significantly reduced longitudinal gust response in cruise. In the conversion regime, a high propulsive force was demonstrated for sustained flight with acceptable blade loads. The VDTR demonstrated excellent gust response capabilities. The horizontal gust response correlated well with predictions revealing only half the response to turbulence of the conventional civil tiltrotor.

Matuska, David↗

Cranial diameter pulsations measured by non-invasive ultrasound decrease with tilt

INTRODUCTION: Intracranial pressure (ICP) may play a significant role in physiological responses to microgravity by contributing to the nausea associated with microgravity exposure. However, effects of altered gravity on ICP in astronauts have not been investigated, primarily due to the invasiveness of currently available techniques. We have developed an ultrasonic device that monitors changes in cranial diameter pulsation non-invasively so that we can evaluate ICP dynamics in astronauts during spaceflight. This study was designed to demonstrate the feasibility of our ultrasound technique under the physiological condition in which ICP dynamics are changed due to altered gravitational force. METHODS: Six healthy volunteers were placed at 60 degrees head-up, 30 degrees headup, supine, and 15 degrees head-down positions for 3 min at each angle. We measured arterial blood pressure (ABP) with a finger pressure cuff, and cranial diameter pulsation with a pulsed phase lock loop device (PPLL). RESULTS: Analysis of covariance demonstrated that amplitudes of cranial diameter pulsations were significantly altered with the angle of tilt (p < 0.001). The 95% confidence interval for linear regression coefficients of the cranial diameter pulsation amplitudes with tilt angle was 0.862 to 0.968. However, ABP amplitudes did not show this relationship. DISCUSSION: Our noninvasive ultrasonic technique reveals that the amplitude of cranial diameter pulsation decreases as a function of tilt angle, suggesting that ICP pulsation follows the same relationship. It is demonstrated that the PPLL device has a sufficient sensitivity to detect changes non-invasively in ICP pulsation caused by altered gravity.

NASA Program Biomedical Research and Countermeasur↗

Spirosymplokos deltaeiberi nov. gen., nov. sp.: variable-diameter composite spirochete from microbial mats

Large (up to 100 micrometers long), loosely coiled, free-living spirochetes with variable diameters (from 0.4 to 3 micrometers in the same cell) were seen at least 40 times between August 1990 and January 1993. These spirochetes were observed in mud water and enrichment media from highly specific habitats in intertidal evaporite flats at three disjunct localities, one in Spain and two in Mexico. All three are sites of commercial saltworks. Associated with Microcoleus chthonoplastes the large spirochetes from Spain display phototaxis and a composite organization. Shorter and smaller-diameter spirochetes are seen inside both healthy and spent periplasm of larger ones. Small spirochetes attached to large ones have been observed live. From two to twelve spirochete protoplasmic cylinders were seen inside a single common outer membrane. A distinctive granulated cytoplasm in which the granules are of similar diameter (20-32 nanometers) to that of the flagella (26 nanometers) was present. Granule diameters were measured in thin section and in negatively-stained whole-mount preparations. Based on their ultrastructure, large size, variable diameter, number of flagella (3 to 6), and phototactic behavior these unique spirochetes are formally named Spirosymplokos deltaeiberi. Under anoxic (or low oxygen) conditions they formed blooms in mixed culture in media selective for spirochetes. Cellobiose was the major carbon source in 80% seawater, the antibiotic rifampicin was added, mat from the original field site was present and tubes were incubated in the light at from 18-31 degrees C. Within 1-2 weeks populations of the large spirochete developed at 25 degrees C but they could not be transferred to fresh medium.

Non-NASA Center↗

Phase-Angle Dependence of Determinations of Diameter, Albedo, and Taxonomy: A Case Study of NEO 3691 Bede

Parameters important for NEO risk assessment and mitigation include Near-Earth Object diameter and taxonomic classification, which translates to surface composition. Diameters of NEOs are derived from the thermal fluxes measured by WISE, NEOWISE, Spitzer Warm Mission and ground-based telescopes including the IRTF and UKIRT. Diameter and its coupled parameters Albedo and IR beaming parameter (a proxy for thermal inertia and/or surface roughness) are dependent upon the phase angle, which is the Sun-target-observer angle. Orbit geometries of NEOs, however, typically provide for observations at phase angles greater than 20 degrees. At higher phase angles, the observed thermal emission is sampling both the day and night sides of the NEO. We compare thermal models for NEOs that exclude (NEATM) and include (NESTM) night-side emission. We present a case study of NEO 3691 Bede, which is a higher albedo object, X (Ec) or Cgh taxonomy, to highlight the range of H magnitudes for this object (depending on the albedo and phase function slope parameter G), and to examine at different phase angles the taxonomy and thermal model fits for this NEO. Observations of 3691 Bede include our observations with IRTF+SpeX and with the 10 micrometer UKIRT+Michelle instrument, as well as WISE and Spitzer Warm mission data. By examining 3691 Bede as a case study, we highlight the interplay between the derivation of basic physical parameters and observing geometry, and we discuss the uncertainties in H magnitude, taxonomy assignment amongst the X-class (P, M, E), and diameter determinations. Systematic dependencies in the derivation of basic characterization parameters of H-magnitude, diameter, albedo and taxonomy with observing geometry are important to understand. These basic characterization parameters affect the statistical assessments of the NEO population, which in turn, affects the assignment of statistically-assessed basic parameters to discovered but yet-to-be-fully-characterized NEOs.

Albedo and taxonomy↗

Development of welded metal bellows having minimum effective diameter change

A program of analysis, design, and fabrication was conducted to develop welded metal bellows having a minimum change in effective diameter for cryogenic turbomachinery face seal applications. Linear analysis of the principle types of bellows provided identification of concepts capable of meeting basic operation requirements. For the 6-inch (.152 m) mean diameter, 1.5-inch free length bellows studied, nonlinear analysis showed that opposed and nested toroidal bellows plates stiffened by means of alternating stiffener rings were capable of maintaining constant effective diameter within 0.3% and 0.1% respectively under the operating conditions of interest. Changes in effective diameter were due principally to bellows axial deflection with pressure differential having a lesser influence. Fabrication problems associated with joining the thin bellows plates to the relatively heavy stiffener rings were encountered and precluded assembly and testing of a bellows core. Fabrication problems are summarized and recommended fabrication methods for future effort are presented.

Henschel, J. K.↗

The occultation of beta Scorpii by Jupiter. VII - The angular diameters of beta Scorpii A1 and A2

A new technique for measuring angular diameters of stars, which makes use of stellar images formed by planetary atmospheres during occultations, is described. This method has been applied to light curves of the 1971 May 13 occultation of beta Sco by Jupiter, yielding the angular diameters of the two early B stars comprising the spectroscopic binary beta Sco A. An angular diameter of about .000422 arcsec for beta Sco A1 and about .000264 arcsec is found for beta Sco A2. These angular diameters are in good agreement with that obtained with the intensity interferometer for beta Sco, a star of nearly the same magnitude and spectral type as beta Sco A1. If the distance to beta Sco A were precisely known, beta Sco A1 and A2 would become fundamental standards of mass, luminosity, and radius for early B stars. Present constraints on the distance and methods by which it could be accurately determined are discussed.

Elliot, J. L.↗

Apparent depth/apparent diameter relation for lunar craters

Photogrammetric measurements from Apollo metric-quality pictures ensure high accuracy of apparent depth (R sub a) and apparent diameter (D sub a) data for fresh lunar craters. R sub a is a direct function of D sub a and the R sub a/D sub a distribution inflects sharply at an apparent diameter of about 15 km. Each of the two resulting subgroups of craters requires two separate least-squares fits. For simple lunar craters (less than 15 km across), the ratio of R sub a to D sub a is about 0.2; the ratio for complex (larger) craters ranges from 0.1 to 0.01. Apparent depth does not exceed 3400 m, regardless of crater size, possibly as a result of isostasy, substrate layering, or curvature of the moon. R sub a/D sub a differences for mare versus terra craters are either absent or are equivocal. The ratio of apparent diameter to rim-crest diameter (D sub a/D sub r) averages 0.83 for smaller craters and 0.86 for larger craters, indicating another simple-to-complex contrast in crater morphology on the moon, and confirms a prediction by R. B. Baldwin for simple craters. Close similarity of D sub a/D sub r for terrestrial experimental craters and simple lunar craters is especially consistent with impact origin for the moon's craters.

Pike, R. J.↗

Error analysis and corrections to pupil diameter measurements with Langley Research Center's oculometer

Factors that can affect oculometer measurements of pupil diameter are: horizontal (azimuth) and vertical (elevation) viewing angle of the pilot; refraction of the eye and cornea; changes in distance of eye to camera; illumination intensity of light on the eye; and counting sensitivity of scan lines used to measure diameter, and output voltage. To estimate the accuracy of the measurements, an artificial eye was designed and a series of runs performed with the oculometer system. When refraction effects are included, results show that pupil diameter is a parabolic function of the azimuth angle similar to the cosine function predicted by theory: this error can be accounted for by using a correction equation, reducing the error from 6% to 1.5% of the actual diameter. Elevation angle and illumination effects were found to be negligible. The effects of counting sensitivity and output voltage can be calculated directly from system documentation. The overall accuracy of the unmodified system is about 6%. After correcting for the azimuth angle errors, the overall accuracy is approximately 2%.

Fulton, C. L.↗

Direct determination of asteroid diameters from occultation observations

Of the available earth-based techniques for determining asteroid diameters, observation of stellar occultations involving asteroids is clearly the most direct. The high degree of accuracy achievable by this method has already been demonstrated in the case of Pallas, whose mean diameter has been measured with a standard error of plus or minus 2%. In this paper the problems, results and prospects of the stellar occultation technique are reviewed. It is shown that, with the use of a network of small, portable telescopes, the method is currently applicable to a large number of asteroids. The best results can be expected for asteroids of large angular diameter and regular shape. The potential of lunar occultation observations for asteroid diameter measurements is also briefly discussed.

Millis, R. L.↗

Effect of hole geometry and Electric-Discharge Machining (EDM) on airflow rates through small diameter holes in turbine blade material

The effects of two design parameters, electrode diameter and hole angle, and two machine parameters, electrode current and current-on time, on air flow rates through small-diameter (0.257 to 0.462 mm) electric-discharge-machined holes were measured. The holes were machined individually in rows of 14 each through 1.6 mm thick IN-100 strips. The data showed linear increase in air flow rate with increases in electrode cross sectional area and current-on time and little change with changes in hole angle and electrode current. The average flow-rate deviation (from the mean flow rate for a given row) decreased linearly with electrode diameter and increased with hole angle. Burn time and finished hole diameter were also measured.

Hippensteele, S. A.↗

The effect of growth rate, diameter and impurity concentration on structure in Czochralski silicon crystal growth

It is demonstrated that maximum growth rates of up to 80% of the theoretical limit can be attained in Czochralski-grown silicon crystals while maintaining single crystal structure. Attaining the other 20% increase is dependent on design changes in the grower, to reduce the temperature gradient in the liquid while increasing the gradient in the solid. The conclusions of Hopkins et al. (1977) on the effect of diameter on the breakdown of structure at fast growth rates are substantiated. Copper was utilized as the test impurity. At large diameters (greater than 7.5 cm), concentrations of greater than 1 ppm copper were attained in the solid (45,000 ppm in the liquid) without breakdown at maximum growth speeds. For smaller diameter crystals, the sensitivity of impurities is much more apparent. For solar cell applications, impurities will limit cell performance before they cause crystal breakdown for fast growth rates of large diameter crystals.

Digges, T. G., Jr.↗

Allowable silicon wafer thickness versus diameter for ingot rotation ID wafering

Inner diameter (ID) wafering of ingot rotation reduce the ID saw blade diameter was investigated. The blade thickness can be reduced, resulting in minimal kerf loss. However, significant breakage of wafers occurs during the rotation wafering as the wafer thickness decreases. Fracture mechanics was used to develop an equation relating wafer thickness, diameter and fracture behavior at the point of fracture by using a model of a wafer, supported by a center column and subjected to a cantilever force. It is indicated that the minimum allowable wafer thickness does not increase appreciably with increasing wafer diameter and that fracture through the thickness rather than through the center supporting column limits the minimum allowable wafer thickness. It is suggested that the minimum allowable wafer thickness can be reduced by using a vacuum chuck on the wafer surface to enhance cleavage fracture of the center core and by using 111 ingots.

Chen, C. P.↗

Analytical calculation of thickness versus diameter requirements of silicon solar cells

It may be more cost-effective to produce larger diameter silicon Cz solar cells. However, greater thickness is anticipated to be necessary for larger diameter wafers to withstand wafering, cell processing and handling. No material standard for these dimensional requirements is practical or cost-effective for cell manufacturers. The equations relating wafer thickness and diameter were derived by using fracture mechanics analysis. An analytical model was used as a guideline to estimate thickness versus diameter requirements of silicon solar cells in terms of fracture mechanics parameters.

Chen, C. P.↗

Economics of ingot slicing with an internal diameter saw for low-cost solar cells

Slicing of silicon ingots using diamond impregnated internal diameter blade saws has been a standard technology of the semiconductor industry. This paper describes work on improvements to this technology for 10 cm diameter ingot slicing. Ingot rotation, dynamic blade edge control with feedback, mechanized blade dressing and development of thinner blades are the approaches tried. A comparison of the results for wafering with and without ingot rotation is also made. A sensitivity analysis of the major cost elements in wafering is performed for 10 cm diameter ingot and extended to the 15 cm diameter ingot case. Various parameter values such as machine cost, feed rate and consumable materials cost are identified both for single and multiple ingot slicing.

Daud, T.↗

Noise reduction for model counterrotation propeller at cruise by reducing aft-propeller diameter

The forward propeller of a model counterrotation propeller was tested with its original aft propeller and with a reduced diameter aft propeller. Noise reductions with the reduced diameter aft propeller were measured at simulated cruise conditions. Reductions were as large as 7.5 dB for the aft-propeller passing tone and 15 dB in the harmonics at specific angles. The interaction tones, mostly the first, were reduced probably because the reduced-diameter aft-propeller blades no longer interacted with the forward propeller tip vortex. The total noise (sum of primary and interaction noise) at each harmonic was significantly reduced. The chief noise reduction at each harmonic came from reduced aft-propeller-alone noise, with the interaction tones contributing little to the totals at cruise. Total cruise noise reductions were as much as 3 dB at given angles for the blade passing tone and 10 dB for some of the harmonics. These reductions would measurably improve the fuselage interior noise levels and represent a definite cruise noise benefit from using a reduced diameter aft propeller.

Dittmar, James H.↗

Noise of a model counterrotation propeller with reduced aft rotor diameter at simulated takeoff/approach conditions (F7/A3)

A model high-speed advanced counterrotation propeller, F7/A3, was tested in the NASA Lewis Research Center 9 by 15 foot Anechoic Wind Tunnel at simulated takeoff/approach conditions of 0.2 Mach number. Acoustic measurements were taken with an axially translating microphone probe, and with a polar microphone probe which was fixed to the propeller nacelle and could take both sideline and circumferential acoustic surveys. Aerodynamic measurements were also made to establish propeller operating conditions. The propeller was run at two setting angles (front angle/rear angle) of 36.4/43.5 and 41.1/46.4 degrees, forward rotor tip speeds from 165 to 259 m/sec, rotor spacings from 8.48 to 14.99 cm based on pitch change axis separation, and angles of attack to 16 degrees. The aft rotor diameter was 85 percent of the forward rotor diameter to reduce tip vortex-aft rotor interaction as a major interaction noise source. Results are compared with equal diameter F7/A7 data which was previously obtained under similar operating conditions. The aft rotor-alone tone was 7 dB lower for the reduced diameter aft rotor, due to reduced tip speed at constant rpm. Interaction tone levels for the F7/A3 propeller were higher at minimum row spacing and lower at maximum spacing.

Woodward, Richard P.↗