Search NASA⌕ Search

SEARCH · Search NASA

Results for “dielectric fluid cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

25 records · Page 2

Automotive Power Electronics Cooling Technology Research at NREL

This presentation describes power electronics thermal management technologies used for on-road EVs. Examples are provided and heat exchangers are described. Advanced cooling technologies developed are NREL to enable increased power density and enable high WBG temperature operation are then presented. The performance (e.g., thermal resistance, pumping power) of the advanced power electronics cooling technologies are compared to the performance of current, on-road technology.

ADVANCED PROPULSION SYSTEMS↗

Flow Assisted Evaporative Cooling for Electric Motor

This paper examines a novel concept of flow assisted latent heat driven two-phase evaporative cooling (EC) confined in-between slot liner and active-winding of electric motor. Wicking micro-structure enhanced PDMS liner axially sucks coolant in the form of thin film between the PDMS liner and active-winding and eventually enables thin film evaporation on the outer surface of the active-winding. Therefore, EC based thermal management eliminates contact resistance between the winding and slot-liner and, enhances the heat extraction from the winding without compromising the electro-magnetic performance. Two-way coupled electro-magnetic (EM) – computational fluid dynamics/heat transfer (CFD/HT) and EM - lumped parameter thermal network (LPTN) models have been developed to assess the electro-thermal performance of the EC under steady and transient conditions. Taking a case study of a 125 kW jacket cooled BMW i3 motor and dielectric coolant FC-84, EC is shown to be capable of handling a maximum steady state rms current density of 26 A/mm2 at a evaporative heat transfer coefficient of 5,000 W/m2.K, which is about 78.7% higher compared to the traditional jacket cooling (JC). In case of EC, a maximum steady state and transient rms current density of 30 A/mm2 (106.2% higher compared to the JC), and 40.8 A/mm2 have been realized by using high thermal conductivity epoxy (1.9 W/m.K) impregnation material. Thermal performance of the EC is also assessed and compared with JC over a dynamic drive cycle. Lastly, a motorette testing has been performed to demonstrate the applicability of the proposed EC method and to validate the developed modeling framework.

42 ENGINEERING↗

Microgravity Experiments and Numerical Modeling of Rotating Buoyant Convection in a Spherical Shell with Latitudinal Thermal Gradients

The results of numerical model calculations are compared with space laboratory experiments for rotating, thermally driven flow in a hemispherical shell, and various flow regimes are described. A spherically symmetric body force, analogous to gravity, is imposed in the radial direction through the use of a dielectric fluid and an electrostatic potential difference across the gap. The spherical boundaries are maintained at constant temperature profiles (with the pole and the inner sphere being the warmer surfaces), and the equatorial wall is an insulator. Typical parameter combinations result in highly nonlinear, but laminar, flow. For weak enough buoyant forcing, the flow is axisymmetric. It consists of a single meridional cell, rising in warm latitudes (in this case, near the pole) and sinking in cool latitudes, with prograde flow in the equatorial region and near the inner hemisphere for other latitudes, and retrograde motion elsewhere. For fast rotation, the first transition due to the instability of this simple flow is also axisymmetric, consisting of rings of convection in the polar region, which propagate poleward. The first nonaxisymmetric convection occurs at Rayleigh numbers which increase with rotation rate. The form of the convection near the transition also depends upon the rate of rotation. Selected flow patterns near the transition as well as those beyond it are studied numerically. For those cases where there exist laboratory experiments with which to compare, the numerical and experimental results agree very well.

Leslie, Fred W.↗

Electrohydrodynamic heat pipe experiments

Experiments with two electrohydrodynamic heat pipes are reported. Both devices employ an electromechanical flow structure for axial liquid flow and a capillary wicking structure for (1) collection of condensed liquid at the cooled end and (2) distribution of this liquid at the heated end. One device has circumferential grooving for the capillary structure and the other has feltmetal wicking. The experiments successfully demonstrate the electrohydrodynamic heat pipe concept. Compatibility of the two circumferential wick structures with an axial electromechanical flow structure is also demonstrated. A significant mismatch of the capillary groove and electrohydrodynamic pumping capabilities results in severe hydrodynamic burn-out limiting in the first heat pipe. Both devices have very poor over-all thermal conductances of the order of 1-2 W/deg C, reflecting the generally poor heat-transfer properties of the dielectric working fluids required in electrohydrodynamic heat pipes.

Jones, T. B.↗

Filamentary surface plasma discharge flow length and time scales

Nanosecond surface dielectric barrier discharges (ns-SDBDs) are a class of plasma actuators that utilize a high-voltage pulse of nanosecond duration between two surface-mounted electrodes to create an electrical breakdown of air, along with rapid heating. These actuators usually produce multiple filaments when operated at high pulse frequencies, and the rapid heating leads to the formation of shock waves and complex flow fields. In this work we replicate a single filament of the ns-SDBDs and characterize the induced flow using velocity measurements from particle image velocimetry and density measurements from background-oriented schlieren. The discharge is produced by a high voltage electrical pulse between two copper electrodes on an acrylic base. A hot gas kernel characterizes the flow field formed close to the electrodes that expands and cools over time and a vortex ring that propagates away from the surface while entraining cold ambient fluid. The gas density deficit inside the kernel displays a power-law decay over time. Based on the observations, we develop a simplified theoretical model based on vortex-driven cooling and perform a scaling analysis to obtain the induced flow length and time scales. The results show that the cooling process's time scales correspond to a circulation-based time scale of the vortex ring, and the length scale of the kernel corresponds to the vortex ring radius. Furthermore, these findings can guide the choice of optimal filament spacing and pulse frequencies in the design, deployment, and operation of ns-SDBDs for flow control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental and analytical study of the hydrodynamic and single and two-phase convective heat transfer performance of flexible PDMS microchannels with micropillar arrays

Various copper and silicon based thermal management systems are used in the cooling of electronics. However, the rigid nature of these materials along with their high thermal and electrical conductivity pose a difficulty in developing direct contact embedded flexible cooling systems that can offer robust cooling performance. The low density, thermal stability, chemical inertness, and electrical insulation of Polydimethylsiloxane (PDMS) make it an ideal material to develop lightweight direct contact thermal management systems for electronics. Its ease of fabrication with tunable flexibility provides the opportunity to go beyond traditional electronics and develop advanced active and passive thermal management systems for a wide–range of applications in foldable and wearable electronics, liquid cooling garments, microgravity, and electric motors. In this study, a flexible PDMS based microchannel with micropillar arrays, which enhance the thermal performance of the device through capillary-assisted flow, has been developed. The hydrodynamic and convection heat transfer performance of three PDMS wick pillar geometries, ranging from a porosity of 0.8–0.91, are investigated and compared under single-phase and two-phase conditions. Dielectric coolant FC-3283 is employed and permeability measurements are made for mass fluxes ranging from 53 kg/m 2 s to 369 kg/m 2 s. Given its conformability, the device demonstrates a deviation from Darcy’s Law, within the laminar regime, with an increasing permeability with mass flux at the rate of ~0.5–0.8 Darcy/(kg/m 2 s). A semi-analytical model has been developed and reported to quantify the conformability of the device. The heat transfer performance is experimentally evaluated using the same dielectric fluid for mass flux ranging from 105 kg/m 2 s to 420 kg/m 2 s with heat fluxes ranging from 1.5 W/cm 2 to 16 W/cm 2 . Heat transfer coefficients of up to 7000 W/m 2 K are observed, which are comparable to copper and silicon microchannels. The effect of porosity on the single phase thermal performance has been evaluated against the pumping power to provide a basis for thermal management system design. Finally, high-speed imaging is performed to study the two-phase flow characteristics to provide insight into the vapor formation and removal.

42 ENGINEERING↗