Search NASA⌕ Search

SEARCH · Search NASA

Results for “differential pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Applications of high pressure differential scanning calorimetry to aviation fuel thermal stability research

High pressure differential scanning calorimetry (DSC) was studied as an alternate method for performing high temperature fuel thermal stability research. The DSC was used to measure the heat of reaction versus temperature of a fuel sample heated at a programmed rate in an oxygen pressurized cell. Pure hydrocarbons and model fuels were studied using typical DSC operating conditions of 600 psig of oxygen and a temperature range from ambient to 500 C. The DSC oxidation onset temperature was determined and was used to rate the fuels on thermal stability. Kinetic rate constants were determined for the global initial oxidation reaction. Fuel deposit formation is measured, and the high temperature volatility of some tetralin deposits is studied by thermogravimetric analysis. Gas chromatography and mass spectrometry are used to study the chemical composition of some DSC stressed fuels.

Neveu, M. C.↗

Optical zero-differential pressure switch and its evaluation in a multiple pressure measuring system

The design of a clamped-diaphragm pressure switch is described in which diaphragm motion is detected by a simple fiber-optic displacement sensor. The switch was evaluated in a pressure measurement system where it detected the zero crossing of the differential pressure between a static test pressure and a tank pressure that was periodically ramped from near zero to fullscale gage pressure. With a ramping frequency of 1 hertz and a full-scale tank pressure of 69 N/sq cm gage (100 psig), the switch delay was as long as 2 milliseconds. Pressure measurement accuracies were 0.25 to 0.75 percent of full scale. Factors affecting switch performance are also discussed.

Powell, J. A.↗

Ring valve responds to differential pressure changes

Pressure valve has a moving annular ring seal that automatically reacts to differential pressure changes across the seat. This valve has good potential for the petroleum and chemical industries.

Source record↗

Reactant pressure differential control for fuel cell gases

A pair of spool valves are described which are balanced between pressures of reactant gases supplied to a fuel cell power plant. The pressure differences are controlled between the gases so as to maintain those pressures substantially in the proportions necessary for operation of the fuel cell.

Grasso, A. P.↗

A program to evaluate a control system based on feedback of aerodynamic pressure differentials. Part 2: Data report for phase 1 wind tunnel test

Wind tunnel test data are presented. The purpose of the test was to determine the sensor location for sensitivity to flap deflection and to determine the range required of the sensor. The calculations followed to correct the raw pressure measurements, the corrected measurements, which represent the static pressures along the airfoil surface, and the static pressures tabulated and in coefficient form are described. However, the chordwise locations of the upper and lower surface taps do not coincide. An interpolation routine is performed to find the lower surface pressure coefficients at the upper surface tap locations. The difference, C sub P(lower) - C sub P(upper), is calculated and listed and the data are reorganized with respect to each tap location. A numerical regression performed to quantify the slopes of the graphs allows more accurate comparison of sensitivity and linearity.

Hrabak, R. R.↗

Flutter Sensitivity to Boundary Layer Thickness, Structural Damping, and Static Pressure Differential for a Shuttle Tile Overlay Repair Concept

This paper examines the aeroelastic stability of an on-orbit installable Space Shuttle patch panel. CFD flutter solutions were obtained for thick and thin boundary layers at a free stream Mach number of 2.0 and several Mach numbers near sonic speed. The effect of structural damping on these flutter solutions was also examined, and the effect of structural nonlinearities associated with in-plane forces in the panel was considered on the worst case linear flutter solution. The results of the study indicated that adequate flutter margins exist for the panel at the Mach numbers examined. The addition of structural damping improved flutter margins as did the inclusion of nonlinear effects associated with a static pressure difference across the panel.

Scott, Robert C.↗

High-Differential-Pressure Heat Exchanger

Heat exchanger accommodates large pressure difference between heat-transfer fluids. Designed so all welded joints inspected with x rays to ensure leak-free operation over many years. Joints between fluids and between each fluid and environment radiographically inspectable. Used in Stirling-cycle engines, including those in proposed nuclear and solar powerplants.

Hylin, Edward C.↗

Experimental and Analytical Investigation of Pressure Differentials for Clean and Loaded Wire Meshes Used in Zeolite Retention

Following failure of the carbon dioxide removal assembly (CDRA) on the ISS, a CDRA teardown, test, and evaluation (TT&E) effort found that the sorbent material was not retained as intended by the packed beds and that presence of the sorbent in the check valve and selector valve was the cause of the failure of these components. This paper documents the development of design data for an in-line filter element. The purpose of the in-line filter is to provide temporary protection for on-orbit CDRA hardware until the bed retainment system can be redesigned and replaced.

Knox, James C.↗

Inherent spiral stability in a fixed wing aircraft by means of a simplified pneumatic wing tip control system

The concept of the lateralizer device is to sense the difference in wing tip static pressures (differential pressures being created by wing tip venturis) produced when any deviation from straight to level flight occurs. In a steady state turn the low slow wing tip experiences less venturi suction than the high fast wing tip. This signal activates the appropriate servos connected to the ailerons to produce a wing leveling restoring moment. If the wing is subjected to rolling velocities due to changes of the local angle of attack at the tip, the downgoing wing tip operates at a higher angle than the upgoing one. If with an increase in the angle of attack the signal is such that it increases the venturi pressure, then the servos are activated to produce the most negative signal to an upgoing aileron which results in a wing leveling restoring moment. In other words, any deviation from straight and level flight in either roll or yaw is exploited and the difference signal from the differential pressures activates the servo to effect or produce the necessary corrective action to null the signal.

Goglia, G. L.↗

DSS 13 antenna monitor system

The development of a monitor system for the DSS 13 antenna is presented. The system checks for accumulator pressures, differential pressures, wind velocity, power supplies, fluid temperatures, and fluid levels. It was concluded that the system performed properly in high winds and correctly reported all malfunctions.

Siev, B.↗

Mechanical counter pressure on the arm counteracts adverse effects of hypobaric exposures

INTRODUCTION: Current space suits have limited movement due to gas pressurization during exposure to the vacuum of space. Alternatively, if pressure is applied by an elastic garment vs. pneumatic garment to produce mechanical counter pressure (MCP), several advantages are possible. In this study, we investigate local microcirculatory and other effects produced with and without a prototype MCP glove and sleeve during exposure to varying levels of vacuum. METHODS: The entire arms of eight male volunteers were studied at normal ambient pressure and during 5 min exposures to -50, -100, and -150 mm Hg with and without the MCP glove and sleeve. Pressure distribution, skin microvascular flow, and temperature were measured. RESULTS: The MCP glove and sleeve generated over 200 mm Hg on the middle finger, dorsum of the hand, and the wrist. However, pressure was significantly lower on the forearm and the upper arm. Without the glove and sleeve, only two of eight subjects tolerated -100 mm Hg. Also, no subject tolerated -150 mm Hg. However, subjects tolerated all vacuum pressures wearing the glove and sleeve. Skin microvascular flow and temperature remained within control values with the glove and sleeve at a chamber pressure of -150 mm Hg. DISCUSSION: The MCP glove and sleeve counteracts adverse effects of vacuum exposures due to lower pressure differentials. Pressure levels over the hand and wrist are similar to those of the current U.S. space suit glove and sleeve, but additional development is required to increase MCP over the forearm and upper arm.

NASA Discipline Cardiopulmonary↗