Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffraction limited light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

24 records · Page 2

Super Smooth Optics for Extra-Solar Planet Detection

The goal of imaging planets around the nearby stars has important scientific significance but requires the use of advanced methods of controlling diffracted and scattered light. Over the last three years we have undertaken a study of coronagraphic methods of controlling diffracted light and of figuring hyper-contrast optics. Progress in these two general areas have led to a proposed space-based, 1.9 meter diameter coronagraphic telescope designed specifically for very high performance in the imaging of faint objects near bright sources. This instrument, called the Circumstellar Imaging Telescope (CIT), relies on a new high efficiency coronagraph design and the careful control of scattered light by extremely smooth optics. The high efficiency coronagraph uses focal plane apodization in order to concentrate diffracted light more efficiently in the pupil. This allows convenient removal of the diffracted light by masking off parts of the telescope pupil while not sacrificing the center of the field. Reductions of diffracted light by factors exceeding 1000 are not only possible but are required in order to detect extra-solar planets. Laboratory experiments with this new design have confirmed the theoretical diffraction reductions to the limits of the optics used (factors of about 300) . The extremely high efficiency of this coronagraph puts strong constraints on the narrow angle scattered light due to figure errors in the telescope mirror. Since planets orbiting nearby stars are expected at angular distances of about 1 arcsecond, it is in this small angular range in which scattering must be controlled. The figure errors responsible for scattering in this range come from mid-spatial frequencies corresponding to correlation lengths of about 10 cm on the primary mirror. A primary mirror about 15 times smoother than the Hubble Space Telescope mirror is required for the CIT. Laboratory experiments indicate that small test mirrors can be fabricated with existing technology which come within a factor of two of this requirement.

Terrile, Richard J.↗

Telescope-optical system performance analysis for the Cryogenic Limb Array Etalon Spectrometer (CLAES) on the Upper Atmospheric Research Satellite

A first-order performance analysis of the CLAES telescope-optical system is presented. The experiment involves the passive measurement of earth-limb radiance over a 10-60 km tangent altitude range, and is based on a solid Fabry-Perot spectrometer which provides spectral resolution of 0.25/cm for atmospheric emission spectroscopy over the 3.5-12 micron IR range. The optical system is required to provide a high degree of off-axis rejection and stray-light control, primarily to suppress intense emission from the earth surface. The astigmatism and other geometric aberrations are corrected by a secondary mirror which produces an excellent image of the primary one, allowing for location of a diffraction control or Lyot stop. The off-axis scattering performance of the telescope is examined in terms of the mirror scatter coefficient and point source rejection ratio. A mirror bidirectional reflectance distribution function of 0.0001 at 1 deg with a 1/theta-squared roll-off between 1 and 0.2 deg is realizable based on recent measurements. This results in an off-axis radiance term that is generally small in comparison with the system-limiting NER.

Roche, A. E.↗

Porosity and Variations in Microgravity Aerogel Nano-Structures: New Laser Speckle Characterization Methods - 2

The transition from sol to gel is a process that is critical to the properties of engineered nanomaterials, but one with few available techniques for observing the dynamic processes occurring during the evolution of the gel network. Specifically, the observation of various cluster aggregation models, such as diffusion-limited and reaction-limited cluster growth can be quite difficult. This can be rather important as the actual aggregation model can dramatically influence the mechanical properties of gels, and is significantly affected by the presence of convective flows, or their absence in microgravity. We have developed two new non-intrusive optical methods for observing the aggregation processes within gels in real time. These make use of the dynamic behavior of laser speckle patterns produced when an intense laser source is passed through a gelling sol. The first method is a simplified time-correlation measurement, where the speckle pattern is observed using a CCD camera and information on the movement of the scattering objects is readily apparent. This approach is extremely sensitive to minute variations in the flow field as the observed speckle pattern is a diffraction-based image, and is therefore sensitive to motions within the sol on the order of the wavelength of the probing light. Additionally, this method has proven useful in determining a precise time for the gel-point, an event often difficult to measure. Monitoring the evolution of contrast within the speckle field is another method that has proven useful for studying aeration. In this case, speckle contrast is dependent upon the size (correlation length) and number of scattering centers, increasing with increasing size, and decreasing with increasing numbers. The dynamic behavior of cluster growth in gels causes both of these to change simultaneously with time, the exact rate of which is determined by the specific aggregation model involved. Actual growth processes can now be observed, and the effects of varying gravity fields on the growth processes qualitatively described. Results on preliminary ground-based measurements have been obtained.

Hunt, A. J.↗

The AIRES Optical Design

AIRES (Airborne InfraRed Echelle Spectrometer) is the facility spectrometer for SOFIA (Stratospheric Observatory For Infrared Astronomy). AIRES is a long-slit (approximately 160 in) spectrometer designed to cover the 17 to 210-micron range with good sensitivity using three spectroscopic arrays. Initially, only the 30-130 micron, mid-wavelength array will be available. The instrument has a cryogenic K-mirror to perform field rotation and a slit-viewing camera (lambda < 28 microns, FOV = 160 in diameter) to image source morphology and verify telescope pointing. AIRES employs a large echelle grating to achieve a spectral resolving power (lambda/delta lambda) of approximately 1.0 x 10(exp 6)/lambda (sub mu), where lambda (sub mu) is the wavelength in microns. Hyperfine, Inc. has ruled and tested the AIRES' echelle; its wave-front error is 0.028 waves RMS (root mean square) at 10.6 microns. The instrument is housed in a liquid-helium cryostat which is constrained in diameter (approximately 1 m) and length (approximately 2 m) by the observatory. Hence, the length of the echelle (approximately 1.1 m) and the focal length of its collimator (approximately 5.2 m) severely drive the optical design and packaging. The final design uses diamond-turned aluminum optics and has up to 19 reflections inside the cryostat, depending on the optical path. This design was generated, optimized, and toleranced using Code V. The predicted performance is nearly diffraction-limited at 17 microns; the error budget is dominated by design residuals. Light loss due to slit rotation and slit curvature has been minimized. A thorough diffraction analysis with GLAD (G-Level Analysis Drawer) was used to size the mirrors and baffles; the internal light loss is shown to be a strong function of slit width.

Haas, Michael R.↗

Diffusivity Measurements Made Instant and Easy

A compact common path interferometer (CPI) system has been developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. It uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. The molecular diffusion coefficient of liquids can be determined from the physical relations between changes in the optical path length and liquid phase properties. When the data obtained by using the CPI have been compared with similar results from other techniques, the instrument has been demonstrated to be far superior to other instruments for measuring the diffusivity of miscible liquids while staying very compact and robust (ref. 1). Because of its compactness and ease of use, the CPI has been adopted for use in studies of interface dynamics as well as other diffusion-controlled process applications (ref. 2). This progress will permit experiments in microgravity that can quantitatively answer basic science questions about mass and thermal diffusion and their effect in transport processes. This instrument is a spinoff of a diagnostic development for microgravity fluid physics experiments at the NASA Glenn Research Center that has used optics and electronics existing in the fluid physics laboratory for feasibility studies. Optical diagnostic techniques have become an integral part of many areas of measurement applications in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used as instruments for measuring optical wave fronts for lens testing and combustion and fluid flow diagnostics. One of these, the point diffraction interferometer, is considered to be robust (see, for example, ref. 3) because it has a common-path design. The point diffraction interferometer is difficult to align and has a limited measurement range for liquid-phase applications. Interferometry and schlieren techniques have been widely used for many years for gas-flow-visualization. On the other hand, the CPI, which is basically a Wollaston prism Polarizer in combination with an analyser (crystalline quartz retardation plate) is used instead of a point diffraction interferometer unit. The advantage of using the CPI over other optical techniques is that it can make quantitative measurements in liquids with the large index of refraction variations that often occur in interface dynamics studies. This can be simply accomplished by using different prism polarizers for each particular experimental condition.

Rashidnia, Nasser↗

Multi-Star Wavefront Control: Update on Technology Development for Roman Space Telescope and Habitable Worlds Observatory

A majority of Sun-like stars have at least one stellar companion that can introduce additional noise into the field of view of any high-contrast imaging instrument, limiting the achievable contrast. These include high-quality target stars such as the A and B components of Alpha Centauri, our nearest stellar neighbor. Enabling direct imaging of binary stars has the potential to increase the scientific yield for coronagraphic instruments planned on NASA's future space missions and concepts, including the Roman Space Telescope and the Astro2020 IR/O/UV flagship. Multi-Star Wavefront Control (MSWC) is a wavefront-control technique that simultaneously removes the (mutually incoherent) stellar leakage from both stellar components, enabling direct imaging of planets in many binary star systems. MSWC is an algorithmic technique and can be used with existing wavefront control systems on coronagraphic instruments (as well as starshades if a deformable mirror is available in the optical path) including planned observations on the upcoming PICTURE-D balloon flight. We report on the latest experimental and numerical results obtained with MSWC as part of the technology development effort to demonstrate compatibility with existing high-contrast imaging platforms for this technique. We first report on functional tests carried out at Subaru's SCExAO instrument operating in-air and showing the sub-Nyquist mode at 4.1e-6 contrast in monochromatic light. The Super-Nyquist regime of MSWC was recently tested in vacuum at JPL's High Contrast Imaging Testbed (HCIT) on the Decadal Survey Testbed (DST) reaching 8.6e-9 contrast in a 10% band. We also report on results for the current stage of vacuum testing at HCIT's Occulting Mask Coronagraph (OMC) testbed using a mask similar to the contributed MSWC mask on the Roman Space Telescope's coronagraph instrument which has demonstrated suppression at the 9.8e-9 contrast at Super-Nyquist separations around the 3rd diffraction order and is planned to use a novel binary source simulator.

high-contrast imaging↗