Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffractive optical elements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Engineering of Exciton Spatial Distribution in CdS Nanoplatelets

Zinc-blende CdS nanoplatelets with atomically flat and very large {100} basal planes terminated solely by one type of element (either Cd or S atoms) are synthesized. Optical spectroscopy, X-ray diffraction, X-ray absorption, and transmission electron microscopy confirm that the surface structures of newly developed S-terminated CdS nanoplatelets are at least as well-defined as the original Cd-terminated nanoplatelets. Band gaps of the nanoplatelets are found to depend on not only the quantum-confined dimension (thickness) but also the nature of the surface termination. The facet structure dictates the packing of the ligands (carboxylate for Cd-terminated nanoplatelets and alkyl for S-terminated nanoplatelets), which causes a difference in the lattice strain and significantly affects the optical spectral width. Experimental and theoretical results reveal that engineering the exciton spatial distribution by the tailored synthesis of semiconductor nanocrystals with a precisely controlled surface structure is fully possible, which should open a new door for delivering the long-promised potential of semiconductor nanocrystals.

Cadmium sulfide↗

Multifunctional light beam source for surface slope measuring long trace profilers

To fully exploit the advantages of fourth-generation synchrotron light sources, diffraction-limited-storage-rings (DLSR) and fully coherent free electron lasers (FELs), beamline mirrors and diffraction grating must be of exceptional quality. To achieve the required mirror and grating quality, the metrology instrumentation and methods used to characterize these challenging optics and, even more so, optical assemblies must also offer exceptional functionality and performance. One of the most widely used slope measuring instruments for characterizing x-ray optics is the long trace profiler (LTP). The easily reconfigurable mechanical design of the LTP allows optimization of the profiler arrangement to the specifics of a particular metrology task. Here, we discuss the optical schematic, design, and performance of an original multifunctional light beam source that provides functional flexibility of the LTP optical sensor. With this source, the LTP can be easily reconfigured for measurements of x-ray mirrors or diffraction gratings that have widely different source coherence requirements. Usage of a source with a low degree of coherence for mirror metrology helps to suppress the LTP systematic errors due to spurious interference effects in the LTP optical elements. A high-coherence narrow-band source is used for groove-density-distribution characterization of x-ray diffraction gratings. The systematic error and spatial resolution of the LTP with the different sources is also measured and analyzed.

Yashchuk, Valeriy V.↗

Characterization data of an (AlFeNiTiVZr) 1-x Cr x multi-principal element alloy continuous composition spread library

The data provided in this article is related to the research article entitled “Phase stabilization and oxidation of a continuous composition spread multi-principal element (AlFeNiTiVZr) 1-x Cr x alloy”. This data article describes the high-throughput synthesis and characterization processes of an (AlFeNiTiVZr) 1-x Cr x alloy system. Continuous composition spread (CCS) thin-film libraries were synthesized by co-depositing an AlFeNiTiVZr metal alloy target and Cr target via magnetron sputtering. Post-processing was performed on the sample libraries with a vacuum anneal at 873 K and an air anneal at 873 K. Compositional data was determined via WDS in order to verify parameters provided by an in-house sputter model. Crystallographic data was captured via synchrotron diffraction and diffractograms were compared as a function of the change in Cr concentration. These measurements were taken in order to observe phase behavior after oxidation throughout the composition library. Furthermore, vibrational spectrographic data is provided of the oxidized library to show surface speciation along the composition gradient of the alloy system. The structural and oxidative behavior of the (AlFeNiTiVZr) 1-x Cr x alloy can be analysed using the data provided in this article. Additionally, this characterization dataset can be utilized in machine learning algorithms for determining important features and parameters for future hypothesis generation of functional multi-principal element alloys (MPEAs).

36 MATERIALS SCIENCE↗

Real-Time Investigation of Sn(II) Oxidation in Pb-Free Halide Perovskites by X-ray Absorption and Mössbauer Spectroscopy

Sn(II) halide perovskites are a less toxic alternative to Pb-based materials in perovskite solar cells, but oxidation to Sn(IV) introduces additional degradation pathways. Improving stability requires mechanistic pictures of O 2 - and H 2 O-induced degradation and their synergy. In this work, we demonstrate that X-ray absorption spectroscopy reports the average valency of the bulk material, allowing oxidation kinetics to be measured from minutes to days. Optical and X-ray diffraction studies demonstrate the challenge of isolating oxidative degradation with techniques lacking element specificity and oxidation state sensitivity. Finally, 119Sn Mössbauer spectroscopy is presented as a lab-based technique capable of providing information on valency and speciation throughout oxidation.

14 SOLAR ENERGY↗

Analytical expressions of the surface shape of ‘diaboloid’ mirrors

Modern deterministic polishing processes allow fabrication of x-ray optics with almost any arbitrary aspherical surface shape. Among these optics, the so called "diaboloid"mirror is of special interest. The diaboloid mirror that converts a cylindrical wave to a spherical wave would improve focusing in x-ray beamlines implementing a diffraction element between a parabolic cylinder and a toroidal mirror. The replacement of the toroidal mirror in existing beamlines by the diaboloid mirror would mitigate aberrations. The shape of the diaboloid mirror is usually calculated numerically based on a truncated polynomial solution of the optical path problem. Here, we present an exact analytical solution for the shape of a diaboloid mirror as a function of the conjugate parameters of the mirror placed in a beamline. The derived analytical expressions for the diaboloid mirror in both the canonical and mirror-based coordinate systems are implemented in ray-tracing simulations to verify the beamline performances.

Yashchuk, Valeriy V.↗

Dynamic motion trajectory control with nanoradian accuracy for multi-element X-ray optical systems via laser interferometry

The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.

47 OTHER INSTRUMENTATION↗

Metal (hydr)oxide surface precipitates and their effects on potassium sorption

Surface precipitation has been shown to occur on rapid time scales in clay and metal oxide mineral systems. The formation of surface precipitates is hypothesized to present new potential sorption sites for potassium (K), where K can become incorporated into newly formed interlayer spaces (e.g., between tetrahedral–octahedral–tetrahedral stacked sheets). The objective of this study is to determine the effects of newly formed mineral surface precipitates on K sorption. Potassium adsorption experiments were conducted by utilizing Al 2 O 3 and SiO 2 sorbents in the presence of various cations (magnesium, zinc, and nickel) that helped to catalyze the formation of surface precipitates. Dissolved concentrations of elements were monitored via inductively coupled plasma optical emission spectrometry (ICP-OES). Solids were characterized via X-ray diffraction (XRD), and K surface complexation was analyzed via X-ray absorption near edge structure (XANES) spectroscopy. X-ray diffraction analysis indicated bayerite, layered double hydroxides (LDH), and silicated LDH were formed as reaction products, thus creating new surface sites for potential K adsorption. The presence of Si increased K adsorption perhaps due to its role in the formation of LDH surface precipitates. When the differences between observed and theoretical surface area normalized K sorption densities were averaged, a 31% increase in K adsorption was observed in the presence of Si. XANES analysis indicated that the binding mechanism of K to Si is different than that of K to Al, perhaps due to the presence of inner-sphere complexation of K to Al-oxide. Samples reacted for one month versus one week yielded more intense XANES post-edge peaks which indicated that the K sorption complex changes over time. Altogether, our findings provide novel insights into the mechanisms of K fixation in soil and has high implication in providing improved K fertilizer recommendation to growers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photochemically induced acousto-optics in gases

Acousto-optics consists of launching acoustic waves in a medium (usually a crystal) in order to modulate its refractive index and create a tunable optical grating. Here, in this article, we present the theoretical basis of an alternative scheme to generate acousto-optics in a gas, where the acoustic waves are initiated by the localized absorption (and thus gas heating) of spatially modulated UV light, as was demonstrated by Michine and Yoneda [Commun. Phys. 3, 24 (2020)]. We identify the chemical reactions initiated by the absorption of UV light via the photodissociation of ozone molecules present in the gas, and calculate the resulting temperature increase in the gas as a function of space and time. Solving the Euler fluid equations shows that the modulated, isochoric heating initiates a mixed acoustic-entropy wave in the gas, whose high-amplitude density (and thus refractive index) modulation can be used to manipulate a high-power laser. We calculate that diffraction efficiencies near 100% can be obtained using only a few millimeters of gas containing a few percent ozone fraction at room temperature, with UV fluences of less than 100 mJ/cm 2 —consistent with the experimental measurements. Our analysis suggests possible ways to optimize the diffraction efficiency by changing the buffer gas composition. Gases have optics damage thresholds 2–3 orders of magnitude beyond those of solids; these optical elements should therefore be able to manipulate kilojoule-class lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating Optical Techniques to Characterize Solid State Samples for the Pu-238 Supply Program

This report documents steps that have been taken to establish advanced characterization capabilities for solid-state samples to support the 238 Pu Supply Program. The program has already invested significantly in spectroscopy and online monitoring development for liquid processes. Many of the data, analytical methods, and equipment could also be leveraged for the analysis of Np/Pu oxides and Np pellets to help classify material properties and link them to operations. The techniques described in this work include diffuse reflectance spectroscopy (DRS), Raman spectroscopy, and laser-induced breakdown spectroscopy (LIBS). Each technique is sensitive to various chemical and/or elemental species and can provide complimentary information to more standard methods such as powder x-ray diffraction and scanning electron microscopy. These options are remotely deployable via fiber-optic cables. DRS and Raman spectroscopy are already approved for glove box and hot cell work, but LIBS requires US Department of Energy approval for incorporation. Raman spectroscopy does require laser shielding, which means that DRS is the easiest method to implement. However, each technique provides complimentary data, and the most robust sample characterization could be achieved when all three, among other methods, are harnessed together. This report documents some of the progress made testing these capabilities, some of the challenges, and next steps to optimize the technology and integration strategies.

07 ISOTOPE AND RADIATION SOURCES↗

Crystal Growth and Elemental Homogeneity of the Multicomponent Rare-Earth Garnet (Lu 1/6 Y 1/6 Ho 1/6 Dy 1/6 Tb 1/6 Gd 1/6 ) 3 Al 5 O 12

We report high-entropy aluminum garnets were grown as bulk single crystals using the micro-pulling-down method, taking the synthesis of complex ceramics a step further from the conventional preparation of polycrystalline materials. We studied the effects of growth parameters on the elemental distribution in high optical quality crystals of (Lu 1/6 Y 1/6 Ho 1/6 Dy 1/6 Tb 1/6 Gd 1/6 ) 3 Al 5 O 12 containing six cations (yttrium and rare-earths) taken in equimolar amounts. A single garnet structure was confirmed by powder X-ray diffraction. Electron microprobe measurements were obtained to correlate the radial distribution of rare-earth elements with pulling rates and molten zone height. The nature of the elemental distribution in the radial direction was associated with ionic radius: smaller rare-earths concentrated in the center of the crystal, while larger rare-earths segregated toward the outer edge of the cylindrical crystal. Faster pulling rates led to a flattening of the concentration profiles toward the nominal concentration, promoting a more homogeneous radial elemental distribution, while varying the molten zone height did not have a significant effect. The demonstrated success with crystal growth enables the practical availability of single crystals of multicomponent aluminum garnets for further discovery of new phenomena and applications.

36 MATERIALS SCIENCE↗

MHz free electron laser x-ray diffraction and modeling of pulsed laser heated diamond anvil cell

A new diamond anvil cell experimental approach has been implemented at the European x-ray Free Electron Laser, combining pulsed laser heating with MHz x-ray diffraction. In this report we use this setup to determine liquidus temperatures under extreme conditions, based on the determination of time-resolved crystallization. The focus is on a Fe-Si-O ternary system, relevant for planetary cores. This time-resolved diagnostic is complemented by a finite-element model, reproducing temporal temperature profiles measured experimentally using streaked optical pyrometry. This model calculates the temperature and strain fields by including (i) pressure and temperature dependencies of material properties, and (ii) the heat-induced thermal stress, including feedback effect on material parameter variations. Making our model more realistic, these improvements are critical as they give 7000 K temperature differences compared to previous models. Laser intensities are determined by seeking minimal deviation between measured and modeled temperatures. Combining models and streak optical pyrometry data extends temperature determination below detection limit. The presented approach can be used to infer the liquidus temperature by the appearance of SiO 2 diffraction spots. In addition, temperatures obtained by the model agree with crystallization temperatures reported for Fe–Si alloys. Our model reproduces the planetary relevant experimental conditions, providing temperature, pressure, and volume conditions. Those predictions are then used to determine liquidus temperatures at experimental timescales where chemical migration is limited. This synergy of novel time-resolved experiments and finite-element modeling pushes further the interpretation capabilities in diamond anvil cell experiments.

36 MATERIALS SCIENCE↗

Quantitative uranium elemental reconstruction using spectral x-ray radiography

X-ray radiography offers the ability to noninvasively inspect the internal structure and material composition of objects. Dual-energy radiography allows material discrimination but is limited in quantitative material measurements due to the broad nature of the interrogating x-ray spectrum. Spectral radiography detectors provide an observation of not just the number of x rays that are transmitted through a sample but also the spectrum. Here, experimental validations of a method to use spectral x-ray radiography to accurately quantify the uranium mass in a powder are presented. An accurate system response model was developed, which includes a model of the incident x-ray source spectrum and a pixel-wise detector response that describes how the transmitted x rays were observed. Further, a calibration to account for the effect of partial x-ray attenuation was developed. As a result, the method is demonstrated to be capable of estimating the uranium mass in a variety of uranium oxide powders to a bias of –0.01±0.62%.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analytical Results for Prepared UIUC F 7 LiNaK

Source materials including 275 g of 7 LiF-NaF-KF (46.5-11.5-42.0 mol %) and 10 g each of several reagent salts were prepared at Argonne for shipment to the University of Illinois at Urbana Champaign. The F 7 LiNaK was packaged in a single jar and reagent salts were placed in small vials. The mass of each shipped salt is listed in Table 1. This report contains details of the preparation procedure and results of elemental composition measurements using inductively coupled plasma-mass spectrometry (ICP-MS) and inductively coupled plasma-optical emission spectrometry (ICP-OES) and phase analyses using X-ray diffraction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Refractive axicon for X-ray microscopy applications: design, optimization, and experiment

In a full-field transmission X-ray microscopy (TXM) setup, a condenser X-ray optical element is used to illuminate the sample by condensing the X-ray beam delivered by the synchrotron storage ring. On-going and future upgrades of synchrotron facilities to diffraction-limited storage rings will pose new challenges to these TXM setups, such as much smaller X-ray beams on the condenser. Here, we demonstrate that a refractive axicon can be used as an X-ray beam shaper to match the ring-shaped aperture of the condenser. Aiming at more efficient use of the incoming X-ray intensity, we explore several axicon designs both analytically and with numerical simulations. The axicons were produced by two-photon polymerization 3D printing on thin silicon nitride membrane substrates. The first characterization of the axicon was carried out at the TOMCAT beamline of the Swiss Light Source (Switzerland).

47 OTHER INSTRUMENTATION↗

Temperature-tuned ultrafast X-ray shutter using optics-on-a-chip

Typically modulation systems are incapable of performing synchronous modulation for high-energy radiation systems. A method and system for performing high-energy synchronous radiation modulating is described. The method includes providing an oscillatory diffractive element, with the oscillatory diffractive element capable of being oscillated over a range of angles. A radiation source provides radiation to the oscillatory diffractive element. An electrical signal is provided to electrodes that oscillate the oscillatory diffractive element to modulate the radiation. A temperature controller controls the temperature of the oscillatory diffractive element to tune the oscillatory motion of the oscillatory diffractive element.

Wang, Jin↗

Intense Reactivity in Sulfur–Hydrogen Mixtures at High Pressure under X-ray Irradiation

Superconductivity near room temperature in the sulfur–hydrogen system arises from a sequence of reactions at high pressures, with X-ray diffraction experiments playing a central role in understanding these chemical–structural transformations and the corresponding S:H stoichiometry. Here we document X-ray irradiation acting as both a probe and as a driver of chemical reaction in this dense hydride system. We observe a reaction between molecular hydrogen (H 2 ) and elemental sulfur (S 8 ) under high pressure, induced directly by X-ray illumination, at photon energies of 12 keV using a free electron laser. The rapid synthesis of hydrogen sulfide (H 2 S) at 0.3 GPa was confirmed by optical observations, spectroscopic measurements, and microstructural changes detected by X-ray diffraction. These results document X-ray induced chemical synthesis of superconductor-forming dense hydrides, revealing an alternative production strategy and confirming the disruptive nature of X-ray exposure in studies on high-pressure hydrogen chalcogenides, from water to high-temperature superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗