A novel compact end-loaded piston cylinder cell for high pressure neutron scattering up to 5 GPa

Here, a miniature sized end-loaded piston cylinder cell with radial side windows for neutron scattering experiments is described. The principle of the bicone-shaped cylinders used was first presented by McWhan in 1974. The present cell is of compact portable design yet significantly enlarges the scattering angles. Its small size allows neutron scattering experiments at low temperatures. The bicone-shaped cylinders are made from various ceramics or a highly neutron-transmissive Ni-free Cr–Mo–V steel. Successful neutron scattering experiments up to 5 GPa have been demonstrated on the CORELLI single-crystal diffractometer and the VISION vibrational spectrometer of the Spallation Neutron Source at the Oak Ridge National Laboratory.

Neutrons

High-pressure neutron diffraction at ultra-low temperature

Neutron diffraction is a powerful tool in the study of quantum materials and associated emergent phenomena as it allows for direct detection of magnetic structure even at ultra-low temperatures. As pressure can drive systems across quantum critical points and tune emergent behaviors at the quantum scale, coupling neutron diffraction with extreme conditions of high pressure at (ultra-)low temperatures has been a key research target over decades. This has proven challenging as magnetic neutron diffraction typically requires large sample volumes due to flux limitations, whereas high-pressure studies require small sample volumes due to pressure limitations. Combining these two contradictory requirements poses many difficulties, but also brings opportunities in research and development. Here, we address these shortcomings through the use of a diamond anvil cell equipped with polycrystalline anvils with relatively large sample volumes coupled with the high neutron flux made available by the high-pressure diffractometer of the Spallation Neutron Source. This particular diamond anvil cell configuration has previously proven useful for single-crystal samples and is here coupled with the ultra-low temperatures of a dilution refrigerator for the first time. Our study on a single crystal of Yb 2 ⁢O 3 successfully collected magnetic neutron diffraction data at 5.3 GPa below 200 mK inside a dilution refrigerator. We have performed a detailed analysis of the magnetic diffraction data to investigate the magnetic structure under pressure and observed a subtle shift in the transition temperature. This development will open the door for future studies on magnetic materials with these much-desired coupled extremes of high pressure and ultra-low temperatures.

Wu, Yan [Oak Ridge National Laboratory (ORNL), Oak

Spin Waves in Dirac Semimetal Ca 0.6⁢ Sr 0.4⁢ MnSb 2 Investigated with Neutrons by the Diffraction Method

The tunability of Dirac semimetals with antiferromagnetic Mn layers is of great interest. The observed sign change of interlayer magnetic coupling between CaMnBi 2 and SrMnBi 2 suggests ionic substitution as a potential tuning mechanism. If so, novel behavior near the compensation point could be expected. Here, to explore this, we study a mixed-cation analog, Ca 0.6⁢ Sr 0.4⁢ MnSb 2 , where Bi is replaced by Sb. Conventional inelastic neutron scattering is impractical due to the small crystal size (m ≈ 0.28 g) available for compositional studies; however, we find that using a neutron diffractometer with a wide-angle area detector we can obtain a good quality spin-wave signal, which is shaped by energy-momentum conservation and retains spectroscopic information even without direct energy analysis. Spin-wave modeling reveals an interlayer coupling quantitatively similar to SrMnSb 2 , indicating it is not directly tuned by ionic size and that the sign change in Bi-based compounds likely arises from the observed change in lattice symmetry. Beyond this key insight, our results present an efficient method for parametric and compositional studies of spin dynamics in small crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Structure of ice VII with Hirshfeld atom refinement

In the refinement of the crystal structures of ice, the best results obtained so far have been with neutron diffraction because the most troublemaking aspects are the hydrogen atoms. In nine out of twenty ice structures, the hydrogen atoms are disordered, which makes proper refinement more difficult. In our previous paper describing the structure of ice VI we proved that, using Hirshfeld atom refinement (HAR) based on synchrotron X-ray data, it is possible to obtain results comparable with those from neutron experiments. In this work, we investigate another structure of high-pressure disordered ice, cubo-ice (ice VII). Single crystals of cubo-ice were grown under pressure in diamond anvil cells. X-ray diffraction measurements were conducted at a synchrotron source facility (APS, University of Chicago, USA) as well as on our regular in-house laboratory diffractometer with Ag radiation. The data collected were further refined with HAR. Comparison of the structural parameters obtained with those derived from neutron diffraction showed very good agreement in terms of bond lengths and fairly good agreement in terms of hydrogen atom ADPs. We were also able to perform unconstrained refinements with various split-atom models.

Chemistry

Magnetic structure determination of multiple phases in the multiferroic candidate GdCrO 3

Due to their potential applications in low-power consumption and/or multistate memory devices, multiferroic materials have attracted a lot of attention in the condensed matter community. As part of the effort to identify new multiferroic compounds, perovskite-based GdCrO 3 was studied in both bulk and thin film samples. A strong enhancement of the capacitance in a field suggested ferroelectric behaviour but significant leakage and no well developed P–E hysteresis loops were observed. Measurements clearly indicate the existence of a polar phase but only below 2 K (likely connected to Gd ordering). Here the determination of the magnetic structure through neutron diffraction collected on an isotopic 160 GdCrO 3 sample at the WISH diffractometer at ISIS is reported. The presence of three successive magnetic phases as a function of temperature (commensurate, spin re-orientation and incommensurate phases once the Gd order), previously only seen by magnetization, is confirmed. Using the most recent guidelines for reporting the determined structures, we highlight the benefits of using such nomenclature for discussing physical properties and consider possible mechanisms and couplings that led this seemingly rather isotropic system to display the complex structures observed.

incommensurate magnetic structure

Neutron powder diffraction, Mossbauer Spectroscopy and Optical Spectroscopy to study magnetic and nuclear lattices in Fe-based oxychlorides Ca2FeO3Cl, Sr2FeO3Cl and Sr3Fe2O5Cl2

Data for Neutron Diffraction, Mossbauer Spectoscopy and Optical Spectroscopy are contained on all three samples (Ca2FeO3Cl, Sr2FeO3Cl, and Sr3Fe2O5Cl2). Mossbauer data are in the folder "MossbauerSpectroscopy". This contains details of files and examples to read the data. The Optical Spectroscopy are in the folder "AbsorptionData", this contains one file with explanatory headers. The neutron diffraction data are in the "NeutronDiffractionData" folder. The data was collected on the HB-2A powder diffractometer at HFIR. The autoreduced files are corrected using a vanadium standard and are in arbitrary intensity units. The RawData folder contains the uncorrected data with metadata for motor positions and temperature. All measurements were collected with a constant neuton wavelength of 2.41 Angstrom. An excel spreadsheet "NeutronDiffractionData_IPTS-29118_summary" contains details for each scan. Sr3Fe2O5Cl2 data were collected at only room temperature. Ca2FeO3Cl and Sr2FeO3Cl data were collected at 4K and room temperature. The autoreduced .dat fileformat is three columns corresponding to: Two-theta, Intensity and Intensity_error.

fe-based oxychlorides

Multiplexing Focusing Analyzer for Efficient Stress-Strain Measurements

Statement of the problem or situation that is being addressed. Although thermal and cold neutron scattering is widely used and is critical for success in many areas of materials science and engineering, relatively low neutron fluxes severely limit applications of not only laboratory neutrons generators, but also large national neutron facilities. State-of-the-art thermal and cold neutron sources are large expensive national facilities, which serve diverse community of scientific and industrial users. The constant need to improve the instruments performance, stems from the fact that neutron methods are gaining in popularity, and becoming more and more powerful, while new neutron sources are not being constructed to keep pace with the developments and needs of the scientific community. Small research reactors at universities and National Labs, and laboratory-based neutron generators, are necessary not only for education and training, but also when samples cannot be transported to other facilities. However, the standard neutron techniques, which were developed for high-flux facilities, require much higher efficiencies to be used effectively with the low fluxes of small sources. Thus, the efficient use of neutron sources, such as with our proposed analyzer, is important for the progress and broader use of these neutron techniques. General statement of how this problem is being addressed. We propose to design and demonstrate novel diffractive optical device, which will enable very efficient residual stress neutron diffractometers. The proposed device will be a multi-foil analyzer, where each foil is constructed of focusing bent single crystals of Si. Such device will enable polychromatic residual stress neutron diffraction. At large national facilities, such as at Oak Ridge National Laboratory, these analyzers would enable very fast measurements for determining residual stress tensors, raster large samples or screen multiple samples. Commercial Applications and Other Benefits The outcome of this project would be the demonstration of commercial devices, novel neutron optical components, which could be utilized to improve the performance of existing instruments or build novel neutron scattering instruments at DOE neutron facilities and commercial laboratory neutron sources. These new devices will widen the scope of research conducted using neutrons and enable measurements not feasible at present. Summary for Members of Congress Thermal and cold neutron beams are a powerful materials science probe, which provide unique information about the structure of matter. The proposed innovations expand the reach of neutron-based investigations to new materials and industries by enabling new instrumentation capabilities, thereby greatly enhancing and expanding the role of small, laboratory-based neutron instrumentation, and improving education and training of neutron users.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

RICH (Robotic Interface Control & Handling) System for VULCAN

High flux neutron beam and high efficiency detectors warrant quick turn arounds of neutron diffraction measurements at the engineering materials diffractometer VULCAN. Efficient change and alignment of samples and automatic measurements at VULCAN are desired for better use of neutron beam time by users. In this work, we aim to develop a proof-of-concept Robotic Interactive Control & Handling System (RICH) for sample handling at VULCAN that could assist high throughput experiments and reduce the overhead time significantly. This was realized by a six-axis desktop robot with trained AI models. The trained AI models can recognize and locate samples in various types of positions in a live video stream. In addition, we developed smart algorithms which used our models on multiple cameras to recognize where samples are with respect to multiple point of views, and then using user-inputted parameters, align them to perform complex measurements.

42 ENGINEERING

Neutrons in Structural Biology: Challenges and Opportunities (Workshop Report)

Gaining a thorough understanding of biological systems requires building our knowledge about biological processes from the level of atoms and electrons, and up to whole organisms. Such comprehensive knowledge will allow for a predictive understanding of complex biological systems behavior. It will guide us in the design and development of novel therapeutics and vaccines to tackle existing health threats and to prepare for future pandemics, and it will provide information necessary to create new biomaterials and bio-inspired technologies through manipulation of biological macromolecules, their assemblies, single cells and even microorganisms. Reaching these goals will require a synergistic combination of multiple experimental techniques with molecular calculations and predictive simulations, and the design and development of new techniques and capabilities that bridge current knowledge and technology gaps. Neutron scattering provides unique information about the biomacromolecular structure and function and can play a major role in achieving these goals. A workshop was held to engage the scientific community in identifying pressing challenges in biochemistry, structural biology, enzymology and structure-guided drug design not solved with the current neutron scattering technologies or utilizing other structural biology techniques such as X-ray crystallography, NMR, and cryo-EM. The workshop brought together structural biology, biochemistry and computational experts, as well as early career researchers and students, creating a forum for discussing scientific advancement and collaboration. The workshop included a one-day satellite training workshop where graduate students and postdoctoral researchers were educated in the application of neutron crystallography and small-angle scattering in structural biology. Furthermore, the Instrument Scientific Advisory Board (ISAB) for the development of a macromolecular neutron diffractometer at ORNL’s Second Target Station was introduced at the workshop. The major outcome was that neutrons can provide atomic-level understanding of biomacromolecular structure, function and dynamics which is of paramount importance for addressing the identified challenges. Neutron crystallography, in particular, can resolve long-standing biochemical issues regarding enzyme function by delineating the underlying chemistry and can have a major impact on the design of small-molecule therapeutics, especially in combination with molecular computation (quantum chemistry and molecular dynamics simulations) and the emerging artificial intelligence (AI)-assisted drug design technologies. The unique properties of neutrons, including their high sensitivity to hydrogen and their non-destructive nature, make them ideal probes of biological matter. There is a palpable need in the scientific community to expand and enhance the impact of neutron sciences on biology. Neutron crystallography is the only structural biology method capable of determining positions of all hydrogen atoms in proteins, nucleic acids and their complexes at near-physiological temperatures and of unstable species at cryogenic temperatures. Moreover, neutron analysis is non-ionizing, non-destructive and does not perturb the structure or redox chemistry of active site metal centers and clusters in proteins, which can be invaluable for studying radiation-sensitive metalloprotein complexes. Further, neutron energies used in scattering applications are similar to atomic motions, permitting neutron spectroscopies to characterize the dynamics of biomacromolecules on the picosecond to microsecond timescales. The different sensitivities of neutrons to protium (H) and deuterium (D) isotopes of hydrogen allow enhanced visibility of specific parts of biological complexes through isotopic labeling. The impact of neutrons will be most powerful when neutron scattering is combined with complementary experimental techniques that use photons and electrons, and with high-performance computing. The interconnection and mutuality of the experimental and theoretical capabilities will drive discoveries in biological and health sciences to generate more complete picture of complex biological systems. The major limitation in the field of biological neutron crystallography has been signal-to-noise, demanding large samples that are difficult to produce for the majority of biomacromolecules and limiting the applicability of this technique in biological sciences. A neutron crystallography instrument at the Second Target Station will revolutionize biological science with neutrons by engaging a large scientific community of structural biologists, enabling successful neutron diffraction experiments from radically smaller biomacromolecular crystals, resolving unanswered biochemical questions, and meaningfully contributing to rational drug design. The meeting highlighted 10 grand challenges that will be addressed with this advanced capability over the next decade and beyond, and the recommendations required to help address them are given below.

59 BASIC BIOLOGICAL SCIENCES

Status Report on Design of In-situ Thermomechanical Testing at LANSCE

Nuclear fuel encounters severe thermomechanical environments in which its mechanical response is determined by its microstructure, temperature and stress level histories. Simulating the response of such microstructures is crucial for predicting both performance and transient fuel mechanical responses and experimental verification of such predictions is therefore of great interest. While most of the deformation in a nuclear fuel rod occurs in the cladding, deformation of the fuel itself is still of interest with deformation mechanisms at operating temperature and above including creep, swelling, cracking as well as pellet-clad interaction. Characterization of these properties and understanding of the underlying deformation phenomena at operating or excursion temperatures is therefore of great importance for development and ultimately licensing of improved and novel nuclear fuel forms. Diffraction techniques offer unique insight on the atomistic (e.g. crystal structure) and microstructure (e.g. phase transformations, texture, defects) length scales and have a long history of providing unique data to inform relevant deformation models that enable the required predictive capabilities. For example, dislocations lead to diffraction peak broadening that can be characterized to estimate the dislocation density and study the role of dislocations on the deformation while measuring lattice strains allows to studie load sharing in two phase materials. In this report the requirements for a sample environment for high temperature deformation of nuclear fuels are defined. The HIPPO neutron time-of-flight diffractometer at LANSCE will host this sample environment and is also described. This instrument covers diffraction angles from 140° to 40° and is also equipped with an event-mode neutron imaging detector system, enabling energy-resolved neutron imaging in parallel with the diffraction that could measure sample temperature from Doppler broadening of neutron absorption resonances or measure pore densities from changes in the attenuation. Designs of devices to characterize thermomechanical properties of nuclear fuel without diffraction are also considered to guide the design. While this report is focused on applications for nuclear fuels, the device can also characterize cladding, moderator or structural materials and therefore contribute to other fields of research and development for advanced reactors. The temperatures planned to be reached are above 2000℃, thus enabling characterization of LWR reactor fuels under accident scenarios but also reaching temperatures of fuels developed for nuclear thermal propulsion and providing opportunities to characterize those. In conjunction with the energy-resolved neutron imaging detector, this setup would allow to measure neutron cross-sections at high temperatures, filling a gap towards development of reactors operating at high temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Multimodal Instrument Concepts for Chemical Sciences at Second Target Station

The development of advanced chemical and energy systems is inherently complex, relying heavily on their unique pathways. Because no two catalysts or batteries follow exactly the same kinetic trajectories, conventional sequential measurements often obscure crucial relationships between structure and dynamics through statistical averaging. This report introduces two neutron scattering instrument concepts for the Second Target Station (STS) specifically designed to overcome this barrier: the Extended Q-range Diffractometer (EQD) and the Multimodal Chemical Spectrometer (MCS).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

What Is the Limit of Quantification for the Minor Phase in Time-of-Flight Neutron Diffraction? A Case Study on Fe and Ni Powder Mixtures at VULCAN

A phase present in small quantities within materials may not simply serve as a secondary component; it can play a crucial role in determining the integrity, properties, and performance of the material. These minor but important phases usually draw attention in material design and processing for fundamental understanding as well as material quality control. Accurately quantifying a minor phase amid a majority phase, especially at extremely low fractions, remains a challenging task. Time-of-flight neutron diffraction, coupled with advanced pattern analysis techniques like Rietveld refinement, is a powerful tool for crystal structure identification and phase quantification. The deep penetrating capability of neutrons enables the detection and quantification of trace phases within materials. In this study, the quantification limits of time-of-flight neutron diffraction were explored using the VULCAN diffractometer at the Spallation Neutron Source, using Fe–Ni powder mixtures as a sample system. By comparing the refinement results to the known weighed values, it was determined that the reliable quantification of a minor Ni phase is achievable down to about 0.1 wt% while a Ni fraction as low as 0.02 wt% is difficult to trace. Effective control of the refinement parameters, especially the profile function parameters, are found to significantly influence the convergence of fittings and the accuracy of phase quantification.

Rietveld refinement

A Smart Vision-Aided RICH (Robotic Interface Control and Handling) System for VULCAN

High-flux neutron beams and high-efficiency detectors enable rapid neutron diffraction measurements at the Engineering Materials Diffractometer (VULCAN) at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL). To optimize beam time utilization, efficient sample exchange, alignment, and automated measurements are essential. Recent advances in artificial intelligence (AI) have expanded the capabilities of robotic systems. Here, we report the development of a Robotic Interactive Control and Handling (RICH) system for sample handling at VULCAN, designed to support high-throughput experiments and reduce overhead time. The RICH system employs a six-axis desktop robot integrated with AI-based computer vision models capable of recognizing and localizing samples in real time from instrument and depth-resolving cameras. Vision algorithms combine these detections to align samples with designated measurement positions or place them within complex sample environments such as furnaces. This integration of machine learning-assisted vision with robotic handling demonstrates the feasibility of autonomous sample detection and preparation, offering a pathway toward fully unmanned neutron scattering experiments.

automation

Low-temperature formation of Ti2AlN during post-deposition annealing of reactive multilayer systems

M n+1 AXn-phase Ti 2 AlN thin-films were synthesized using reactive sputtering-based methods involving the deposition of single-layer TiAlN, and Ti/AlN and TiN/TiAl multilayers of various modulation periods at ambient temperature and subsequent annealing at elevated temperatures. Ex situ and in situ x-ray diffraction measurements were used to characterize the Ti 2 AlN formation temperature and phase fraction. During annealing, Ti/AlN multilayers yielded Ti 2 AlN at a significantly lower in situ temperature of 650 °C compared to TiN/TiAl multilayers or single-layer TiAlN (750 °C). The results suggest a reactive multilayer mechanism whereby distinct Ti and AlN layers react readily to release exothermic energy resulting in lower phase transition temperatures compared to TiN and TiAl layers or mixed TiAlN. With a modulation period of 5 nm, however, Ti/AlN multilayers yielded Ti 2 AlN at a higher temperature of 750 °C, indicating a disruption of the reactive multilayer mechanism due to a higher fraction of low-enthalpy interfacial TiAlN within the film.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Instrumentation and Samples (CRADA Final Report)

Instruments which are categorized as shared user instruments at the National Laboratory of the Rockies (NLR) will be utilized for ongoing technical work. Samples will be provided by University of Colorado Boulder (CU) and thus no need for materials at NLR is anticipated.