Diffusion in the system K sub 2 O-SrO-SiO sub 2. I - Effective binary diffusion coefficients.
Effective binary diffusion coefficients for multicomponent diffusion determined for potassium oxide and SrO in system potassium oxide-SrO- silicon dioxide
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Effective binary diffusion coefficients for multicomponent diffusion determined for potassium oxide and SrO in system potassium oxide-SrO- silicon dioxide
Not Available
Diffusion cell and diffusion wafer experiments were conducted to compare methods for estimating matrix diffusion coefficients in rock core samples from Pahute Mesa at the Nevada Nuclear Security Site (NNSS). A diffusion wafer method, in which a solute diffuses out of a rock matrix that is pre-saturated with water containing the solute, is presented as a simpler alternative to the traditional through-diffusion (diffusion cell) method. Both methods yielded estimates of matrix diffusion coefficients that were within the range of values previously reported for NNSS volcanic rocks. The difference between the estimates of the two methods ranged from 14 to 30%, and there was no systematic high or low bias of one method relative to the other. From a transport modeling perspective, these differences are relatively minor when one considers that other variables (e.g., fracture apertures, fracture spacings) influence matrix diffusion to a greater degree and tend to have greater uncertainty than diffusion coefficients. For the same relative random errors in concentration measurements, the diffusion cell method yields diffusion coefficient estimates that have less uncertainty than the wafer method. However, the wafer method is easier and less costly to implement and yields estimates more quickly, thus allowing a greater number of samples to be analyzed for the same cost and time. Given the relatively good agreement between the methods, and the lack of any apparent bias between the methods, the diffusion wafer method appears to offer advantages over the diffusion cell method if better statistical representation of a given set of rock samples is desired.
Applications and limitations of proposed concept of effective binary diffusion coefficient for analyzing interdiffusion of multicomponent systems
Concentration gradient diffusion coefficients for Ce 3+ , Co 2+ , Mn 2+ and Fe 2+ cations are determined in Nafion®211 membranes over a wide range of environmental conditions. Measurements are made using finite-width cation-rich bands introduced to NR211 via a hot-pressing procedure. A robust method of accurate diffusion coefficient determination of the finite-width deposits is developed using a Fick's second law of diffusion solution for one-dimensional systems. The transition metal dications are found to have nearly identical NR211 diffusion coefficients under water saturated conditions over the 22–80 °C range. The powerful chemical mitigant, Ce 3+ , is about one-half as diffusive as the dications under identical conditions. Derived diffusion coefficients for Ce 3+ and Co 2+ are found to be independent of initial cation concentration over the range of 12.5–70 mol% exchange level. The diffusion behavior of Ce 3+ in 80 °C liquid water and saturated water vapor is identical. The diffusion coefficients of Ce 3+ are shown to have a strong dependence on membrane hydration level varying by a factor of more than 30 over the range of 95 to 40% RH. Finally, the implications of these new diffusion findings are applied to a discussion of potential guidelines for the development of highly durable fuel cell systems, which employ mobile metal cations as lifetime-extending redox stabilizers.
Diffusion calculations were performed to establish the conditions under which concentration dependence of the diffusion coefficient was important in single, two, and three phase binary alloy systems. Finite-difference solutions were obtained for each type of system using diffusion coefficient variations typical of those observed in real alloy systems. Solutions were also obtained using average diffusion coefficients determined by taking a logarithmic average of each diffusion coefficient variation considered. The constant diffusion coefficient solutions were used as reference in assessing diffusion coefficient variation effects. Calculations were performed for planar, cylindrical, and spherical geometries in order to compare the effect of diffusion coefficient variations with the effect of interface geometries. In most of the cases considered, the diffusion coefficient of the major-alloy phase was the key parameter that controlled the kinetics of interdiffusion.
The self-diffusion coefficients were measured by introducing a slab of glass previously irradiated in a reactor between two slabs of unirradiated glass. By heating the specimens, etching them sequentially and determining the radioactivity, self-diffusion coefficients for K and Sr were measured. It is pointed out that the results obtained in the investigations appear to support the proposal that the network of the base glass predominantly controls the activation energy for the diffusion of ions.
Precise diffusion measurements of rhodamine 6G (Rh6G) dissolved in D{sub 2}O at concentrations between 50 and 200 μM were carried out in the temperature range from 280 to 320 K using pulsed field gradient nuclear magnetic resonance (PFG-NMR). The obtained diffusion coefficients can be used as a calibration reference in fluorescence correlation spectroscopy (FCS). Besides measuring the diffusivity of Rh6G, the diffusion coefficient of the solvent in the same system could be determined in parallel by PFG-NMR as the resonances of water and Rh6G are well separated in the {sup 1}H NMR spectrum. To analyze the differences due to the isotope effect of the solvent (D{sub 2}O vs. H{sub 2}O), the correlation time τ{sub D} of Rh6G was measured by FCS in both D{sub 2}O and H{sub 2}O. The obtained isotopic correction factor, τ{sub D}(D{sub 2}O)/τ{sub D}(H{sub 2}O) = 1.24, reflects the isotope effect of the solvent´s self-diffusion coefficients as determined previously by PFG-NMR.
Here, diffusion cell and diffusion wafer experiments were conducted to compare methods for estimating effective matrix diffusion coefficients in rock core samples from Pahute Mesa at the Nevada Nuclear Security Site (NNSS). A diffusion wafer method, in which a solute diffuses out of a rock matrix that is pre-saturated with water containing the solute, is presented as a simpler alternative to the traditional through-diffusion (diffusion cell) method. Both methods yielded estimates of effective matrix diffusion coefficients that were within the range of values previously reported for NNSS volcanic rocks. The difference between the estimates of the two methods ranged from 14 to 30%, and there was no systematic high or low bias of one method relative to the other. From a transport modeling perspective, these differences are relatively minor when one considers that other variables (e.g., fracture apertures, fracture spacings) influence matrix diffusion to a greater degree and tend to have greater uncertainty than effective matrix diffusion coefficients. For the same relative random errors in concentration measurements, the diffusion cell method yields effective matrix diffusion coefficient estimates that have less uncertainty than the wafer method. However, the wafer method is easier and less costly to implement and yields estimates more quickly, thus allowing a greater number of samples to be analyzed for the same cost and time. Given the relatively good agreement between the methods, and the lack of any apparent bias between the methods, the diffusion wafer method appears to offer advantages over the diffusion cell method if better statistical representation of a given set of rock samples is desired.
Diffusive mass transfer in biofilms is characterized by the effective diffusion coefficient. It is well-documented that the effective diffusion coefficient can vary by location in a biofilm. The current literature is dominated by effective diffusion coefficient measurements for distinct cell clusters and stratified biofilms showing this spatial variation. Regardless of whether distinct cell clusters or surface-averaging methods are used, position-dependent measurements of the effective diffusion coefficient are currently: 1) invasive to the biofilm, 2) performed under unnatural conditions, 3) lethal to cells, and/or 4) spatially restricted to only certain regions of the biofilm. Invasive measurements can lead to inaccurate results and prohibit further (time dependent) measurements which are important for the mathematical modeling of biofilms. In this study our goals were to: 1) measure the effective diffusion coefficient for water in live biofilms, 2) monitor how the effective diffusion coefficient changes over time under growth conditions, and 3) correlate the effective diffusion coefficient with depth in the biofilm. We measured in situ two-dimensional effective diffusion coefficient maps within Shewanella oneidensis MR-1biofilms using pulsed-field gradient nuclear magnetic resonance methods, and used them to calculate surface-averaged relative effective diffusion coefficient (Drs) profiles. We found that 1) Drs decreased from the top of the biofilm to the bottom, 2) Drs profiles differed for biofilms of different ages, 3) Drs profiles changed over time and generally decreased with time, 4) all the biofilms showed very similar Drs profiles near the top of the biofilm, and 5) the Drs profile near the bottom of the biofilm was different for each biofilm. Practically, our results demonstrate that advanced biofilm models should use a variable effective diffusivity which changes with time and location in the biofilm.
The DC (Diffusion Coefficient) code obtains RF diffusion coefficients by direct numerical integration of the Lorentz force equation for ion motion in the combined equilibrium fields and the RF full wave EM fields from the AORSA full-wave code. Suitable averaging over initial gyro- and toroidal-angle of coordinate 'kicks' after a bounce-period, gives noise-free bounce-averaged diffusion coefficients. For direct comparison with zero-banana-width coefficients from AORSA, perpendicular-drift terms in the Lorentz equation are subtracted off the integration. The DC code has been coupled to the CQL3D Fokker-Planck code. For a C-Mod minority ion ICRF heating test case, the total power absorption using the diffusion coefficients agree well, and the profiles are similarly close. This supports the DC calculation and the Kennel-Engelmann-based, no-correlations, coefficient calculation in AORSA. However, resonance correlations cause large differences in the pitch angle variations of the diffusion coefficients, and in the resulting evolution of the ion distribution functions.
The directional diffusion coefficients of low-energy (greater than or equal to 0.3 MeV) solar protons inside and outside the bow shock are examined during the solar flare event of Jan. 24, 1969. The data are derived from simultaneous observations obtained by Explorer 33 inside the magnetosheath and by Explorer 35 in the interplanetary medium. Although the gross properties of the spin-averaged intensities on a diffusion-type plot appear to be the same in both media, the directional intensities show significant variations. It is shown that directional intensities of low-energy protons can be described reasonably well by anisotropic diffusion with an associated diffusion coefficient. Directional diffusion coefficients are found to differ by a factor of as much as three among different directions in space, and from the spin-averaged diffusion coefficient. This suggests that anisotropic diffusion does indeed take place and that so called 'isotropic' diffusion coefficients derived in the past from spin-averaged intensities may actually be directional diffusion coefficients in cases where substantial anisotropies (greater than 50%) exist.
We report most impurity diffusion coefficients were measured in the 1960s and 1970s using tracer experiments with only 14 sets of tracer measurements performed worldwide in the past 15 years. It is thus impractical to rely on tracer experiments to obtain the missing thousands of impurity diffusion coefficients. A recently developed forward-simulation analysis can change the scenario by reliably extracting impurity diffusion coefficients from regular diffusion couple profiles. A comparison of 51 values obtained from the forward-simulation analysis with tracer experiment values in the literature shows an excellent agreement, thus validating the reliability of the forward-simulation analysis in obtaining accurate impurity diffusion coefficients.
Rayleigh interferometry is one of the most precise and accurate methods for the experimental determination of the mutual diffusion coefficients of both electrolytes and non-electrolytes in liquid solutions. For binary solutions at moderate and high concentrations where the concentration dependences of both diffusion coefficient and refractive index can be assumed to be linear or almost linear and the concentration difference ΔC between a pair of solutions undergoing free diffusion is not large compared to their average concentration, and by using proper combinations of the interference fringe positions as they vary with time, under these conditions diffusion coefficients are obtained that are independent of the size of ΔC. However, this situation becomes more complicated at low concentrations for electrolyte solutions where the concentration dependences of both the diffusion coefficient and refractive index are non-linear, with C 1/2 dependence for the diffusion coefficient and C 3/2 dependence for the refractive index. As a test of these effects on calculated mutual diffusion of electrolyte solutions at low concentrations as measured by Rayleigh interferometry, apparent mutual diffusion coefficients D v,a (volume-fixed reference frame) were measured for fixed average concentrations C=(0.02989 ± 0.00001) mol·dm –3 of Na 2 SO 4 (aq) at 298.15 K while varying ΔC/C from 0.66673 to 2, a threefold variation. The dependence of the diffusion coefficient on ΔC/C was found to be linear, yielding D v = 1.041 6 × 10 –9 m 2 ·s –1 for an infinitely small concentration difference between the diffusing solutions.
A theory of quasilinear diffusion for obliquely propagating electromagnetic waves was developed in the 1960's and applied in the 1970's to model scattering of relativistic electrons by a prescribed distribution of waves. In the latter work, a transformation of variables, from wavevector space to the temporal frequency and tangent of the wave normal angle, was used so that simple Gaussian functions of frequency and tangent of the wave normal angle could be multiplied together to define the distribution of wave power, although arbitrary distributions of power in these two variables is also permitted. Finally, in 2005, previous work was consolidated and has been widely used in heliophysics studies that require computation of quasilinear diffusion coefficients. Here it is shown that this transformation is inppropriate when the precise wave vector distribution is known. The correct transformation is derived and used to produce diffusion coefficients that can differ by orders of magnitude from those computed using the inappropriate transformation. The differences are largest when the distribution of wave power extends to wave normal angles near the resonance cone. When the ratio of the plasma frequency to the gyrofrequency is large, only low energies (keV) are affected, but as the ratio decreases higher energies (MeV) also show differences. It is also shown that the derivation from the 1960's uses a notation that results in the diffusion coefficients depending on the distribution of wave power with respect to the wave azimuthal angle whereas there should be no such dependence.
Electron pitch angle (D (alpha)) and momentum (D(pp)) diffusion coefficients have been calculated due to resonant interactions with electrostatic electron cyclotron harmonic (ECH) and whistler mode chorus waves. Calculations have been performed at two spatial locations L = 4.6 and 6.8 for electron energies 10 keV. Landau (n = 0) resonance and cyclotron harmonic resonances n = +/-1, +/-2,...+/-5 have been included in the calculations. It is found that diffusion coefficient versus pitch angle (alpha) profiles show large dips and oscillations or banded structures. The structures are more pronounced for ECH and lower band chorus (LBC) and particularly at location 4.6. Calculations of diffusion coefficients have also been performed for individual resonances. It is noticed that the main contribution of ECH waves in pitch angle diffusion coefficient is due to resonances n = +1 and n = +2. A major contribution to momentum diffusion coefficients appears from n = +2. However, the banded structures in D alpha and Dpp coefficients appear only in the profile of diffusion coefficients for n = +2. The contribution of other resonances to diffusion coefficients is found to be, in general, quite small or even negligible. For LBC and upper band chorus waves, the banded structures appear only in Landau resonance. The Dpp diffusion coefficient for ECH waves is one to two orders smaller than D alpha coefficients. For chorus waves, Dpp coefficients are about an order of magnitude smaller than D alpha coefficients for the case n does not = 0. In case of Landau resonance, the values of Dpp coefficient are generally larger than the values of D alpha coefficients particularly at lower energies. As an aid to the interpretation of results, we have also determined the resonant frequencies. For ECH waves, resonant frequencies have been estimated for wave normal angle 89 deg and harmonic resonances n = +1, +2, and +3, whereas for whistler mode waves, the frequencies have been calculated for angle 10 deg and Landau resonance. Further, in ECH waves, the banded structures appear for electron energies (is) greater than1 keV, and for whistler mode chorus waves, structures appear for energies greater than 2 keV at L = 4.6 and above 200 eV for L = 6.8. The results obtained in the present work will be helpful in the study of diffusion curves and will have important consequences for diffuse aurora and pancake distributions.