Search NASA⌕ Search

SEARCH · Search NASA

Results for “dilation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Adherence to Vaginal Dilation Following High Dose Rate Brachytherapy for Endometrial Cancer

Purpose: We report demographic, clinical, and psychosocial factors associated with adherence to vaginal dilation and describe the sexual and marital or nonmarital dyadic functioning of women following high dose rate (HDR) brachytherapy for endometrial cancer. Methods and Materials: We retrospectively evaluated women aged 18 years or older in whom early-stage endometrial (IAgr3-IIB) cancers were treated by HDR intravaginal brachytherapy within the past 3.5 years. Women with or without a sexual partner were eligible. Patients completed questionnaires by mail or by telephone assessing demographic and clinical variables, adherence to vaginal dilation, dyadic satisfaction, sexual functioning, and health beliefs. Results: Seventy-eight of 89 (88%) eligible women with early-stage endometrial cancer treated with HDR brachytherapy completed questionnaires. Only 33% of patients were adherers, based on reporting having used a dilator more than two times per week in the first month following radiation. Nonadherers who reported a perceived change in vaginal dimension following radiation reported that their vaginas were subjectively smaller after brachytherapy (p = 0.013). Adherers reported more worry about their sex lives or lack thereof than nonadherers (p = 0.047). Patients reported considerable sexual dysfunction following completion of HDR brachytherapy. Conclusions: Adherence to recommendations for vaginal dilator use following HDR brachytherapy for endometrial cancer is poor. Interventions designed to educate women about dilator use benefit may increase adherence. Although sexual functioning was compromised, it is likely that this existed before having cancer for many women in our study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accurate modeling and reconstruction of three-dimensional percolating filamentary microstructures from two-dimensional micrographs via dilation-erosion method

Heterogeneous materials are ubiquitous in nature and synthetic situations and have a wide range of important engineering applications. Accurate modeling and reconstructing three-dimensional (3D) microstructure of topologically complex materials from limited morphological information such as a two-dimensional (2D) micrograph is crucial to the assessment and prediction of effective material properties and performance under extreme conditions. Here, we extend a recently developed dilation–erosion method and employ the Yeong–Torquato stochastic reconstruction procedure to model and generate 3D austenitic–ferritic cast duplex stainless steel microstructure containing percolating filamentary ferrite phase from 2D optical micrographs of the material sample. Specifically, the ferrite phase is dilated to produce a modified target 2D microstructure and the resulting 3D reconstruction is eroded to recover the percolating ferrite filaments. The dilation–erosion reconstruction is compared with the actual 3D microstructure, obtained from serial sectioning (polishing), as well as the standard stochastic reconstructions incorporating topological connectedness information. The fact that the former can achieve the same level of accuracy as the latter suggests that the dilation–erosion procedure is tantamount to incorporating appreciably more topological and geometrical information into the reconstruction while being much more computationally efficient. - Highlights: • Spatial correlation functions used to characterize filamentary ferrite phase • Clustering information assessed from 3D experimental structure via serial sectioning • Stochastic reconstruction used to generate 3D virtual structure 2D micrograph • Dilation–erosion method to improve accuracy of 3D reconstruction.

36 MATERIALS SCIENCE↗

The Dark Energy Survey Supernova Program: slow supernovae show cosmological time dilation out to z ~ 1.

ABSTRACT We present a precise measurement of cosmological time dilation using the light curves of 1504 Type Ia supernovae from the Dark Energy Survey spanning a redshift range $0.1\lesssim z\lesssim 1.2$. We find that the width of supernova light curves is proportional to $(1+z)$, as expected for time dilation due to the expansion of the Universe. Assuming Type Ia supernovae light curves are emitted with a consistent duration $\Delta t_{\rm em}$, and parametrizing the observed duration as $\Delta t_{\rm obs}=\Delta t_{\rm em}(1+z)^b$, we fit for the form of time dilation using two methods. First, we find that a power of $b \approx 1$ minimizes the flux scatter in stacked subsamples of light curves across different redshifts. Secondly, we fit each target supernova to a stacked light curve (stacking all supernovae with observed bandpasses matching that of the target light curve) and find $b=1.003\pm 0.005$ (stat) $\pm \, 0.010$ (sys). Thanks to the large number of supernovae and large redshift-range of the sample, this analysis gives the most precise measurement of cosmological time dilation to date, ruling out any non-time-dilating cosmological models at very high significance.

79 ASTRONOMY AND ASTROPHYSICS↗

Plastic cap evolution law derived from induced transverse isotropy in dilatational triaxial compression.

Mechanical testing of porous materials generates physical data that contain contributions from more than one underlying physical phenomenon. All that is measurable is the "ensemble" hardening modulus. This thesis is concerned with the phenomenon of dilatation in triaxial compression of porous media, which has been modeled very accurately in the literature for monotonic loading using models that predict dilatation under triaxial compression (TXC) by presuming that dilatation causes the cap to move outwards. These existing models, however, predict a counter-intuitive (and never validated) increase in hydrostatic compression strength. This work explores an alternative approach for modeling TXC dilatation based on allowing induced elastic anisotropy (which makes the material both less stiff and less strong in the lateral direction) with no increase in hydrostatic strength. Induced elastic anisotropy is introduced through the use of a distortion operator. This operator is a fourth-order tensor consisting of a combination of the undeformed stiffness and deformed compliance and has the same eigenprojectors as the elastic compliance. In the undeformed state, the distortion operator is equal to the fourth-order identity. Through the use of the distortion operator, an evolved stress tensor is introduced. When the evolved stress tensor is substituted into an isotropic yield function, a new anisotropic yield function results. In the case of the von Mises isotropic yield function (which contains only deviatoric components), it is shown that the distortion operator introduces a dilatational contribution without requiring an increase in hydrostatic strength. In the thesis, an introduction and literature review of the cap function is given. A transversely isotropic compliance is presented, based on a linear combination of natural bases constructed about a transverse-symmetry axis. Using a probabilistic distribution of cracks constructed for the case of transverse isotropy, a compliance expression is presented that demonstrated a decrease in lateral stiffness, but leaves axial stiffness unchanged. A demonstration of how the distortion operator could be used in the elastic/plastic analysis of a von Mises surface loaded in TXC is also presented.

36 MATERIALS SCIENCE↗

Dilation Behavior of Thermal Spray Coatings

The thermal expansion of a thermally sprayed coating material is an important design-relevant property from both processing and application service points of view. High thermal stresses and residual strains can arise during deposition, and thermal exposure in service. The linkage to process conditions which can impact both physical and chemical attributes of the microstructure and consequently its expansion behavior is of great importance. The observed dilation response of various coatings is discussed based on the processing effects that induce differences in microstructural features and the impact of residual strain and annealing of defects on the dilation behavior during first thermal exposure. The coefficient of thermal expansion (CTE) of coatings was found to approach the bulk when the material is not sensitive to oxidation in-flight. For those materials sensitive to oxidation, mathematical models used to describe effective properties of composite materials were adopted to describe the CTE property. A large irreversible dilation change was found in the first heating cycle due to defect annealing (referred to as thermal shakedown). Several reasons are hypothesized for the magnitude of such dilation change. Finally, together, the paper presents a comprehensive analysis of thermal expansion behavior of a diversity of thermal spray processed materials.

36 MATERIALS SCIENCE↗

Inferring fracture dilation and shear slip from surface deformation utilising trained surrogate models

An important task in energy and CO 2 storage (sequestration) in the subsurface is to verify that the surrounding fractures and faults are not activated, acting as leakage pathways. This is achievable through effective and efficient Measurement, Monitoring and Verification (MMV) plans. In this work, two surrogate models are trained to captures dilation (opening) and shear deformation of fractures, and the associated surface deformation. The trained surrogate model, based on conditional Generative-Adversarial Networks (cGAN) receives fracture apertures from dilational fractures together with fracture slips from shear fractures and predicts the combined surface deformation. An inversion algorithm based on Bayesian framework is proposed to identify the geometry of both types of fractures, as well as volume of dilational fractures and deformation moment induced by shear fractures, all from the measured surface deformation data. The inversion algorithm utilises the Differential Evolution (DE) optimisation technique that has the superior performance in finding the global minimum of cost function. The proposed surrogate-assisted inversion successfully inferred the unknown dip, dip direction and the volume of the dilational fractures as well as the induced deformation moment in shear fractures. The model was further tested for the inversion of a field hydraulic fracturing tilt dataset applying different scenarios with varying unknowns to show the model's performance, as well as incorporating shear deformation for better match with the observed data.

Dilation and shear↗

Constraints on Friction, Dilatancy, Diffusivity, and Effective Stress From Low-Frequency Earthquake Rates on the Deep San Andreas Fault

Families of recurring low-frequency earthquakes (LFEs) within nonvolcanic tremor on the San Andreas Fault in central California are sensitive to tidal stresses. LFEs occur at all levels of the tides, are strongly correlated and in phase with the ~200 Pa shear stresses, and weakly and not systematically correlated with the ~2 kPa tidal normal stresses. Here, we assume that LFEs are small sources that repeatedly fail during shear within a much larger scale, aseismically slipping fault zone and consider two different models of the fault slip: (1) modulation of the fault slip rate by the tidal stresses or (2) episodic slip, triggered by the tides. LFEs are strongly clustered with duration much shorter than the semidiurnal tide; they cannot be significantly modulated on that time scale. The recurrence times of clusters, however, are many times longer than the semidiurnal, leading to an appearance of tidal triggering. In this context we examine the predictions of laboratory-observed triggered frictional (dilatant) fault slip. The undrained end-member model produces no sensitivity to the tidal normal stress, and slip onsets are in phase with the tidal shear stress. The tidal correlation constrains the diffusivity to be less than ~1 × 10 -6 /s and the product of the friction and dilatancy coefficients to be at most 5 × 10 -7 , orders of magnitude smaller than observed at room temperature. In the absence of dilatancy the effective normal stress at failure would be about ~55 kPa. Finally, for this model the observations require intrinsic weakness, low dilatancy, and lithostatic pore fluid.

58 GEOSCIENCES↗

Intravenous mesenchymal stem cell-derived exosomes ameliorate myocardial inflammation in the dilated cardiomyopathy

Mesenchymal stem cells (MSCs) have been shown to be efficacy to attenuating cardiovascular inflammation; however, there are many limitations to stem cell treatment. Present study was to prove MSC-derived exosomes (MSC-Exos) could alleviating inflammatory cardiomyopathy by improving the inflammatory microenvironment of myocardium, especially by regulating the activity of macrophages. Mice were intraperitoneal injected of doxorubicin (DOX) to establish a dilated cardiomyopathy (DCM) model, and then received intravenous injection of either MSC-Exos or PBS as control. Mice receiving MSC-Exos showed improved cardiac function via echocardiography and attenuated cardiac dilation via HE staining, as well as reduced cardiomyocytes apoptosis. Expression levels of inflammatory factors were reduced. And there was a significant decrease of the inflammatory cells infiltration in the MSC-Exos treatment group comparing to the PBS group. Meanwhile, MSC-Exos could remarkably attenuate the pro-inflammatory macrophages amount in both blood and heart, which was proved that MSC-Exos relied on the JAK2-STAT6 pathway mediating macrophages activation. MSC-Exos improved the inflammatory microenvironment of dilated cardiomyopathy by regulating the polarization of the macrophage, which may hold promise for dilated cardiomyopathy clinical therapy.

60 APPLIED LIFE SCIENCES↗

Sarcomeric perturbations of myosin motors lead to dilated cardiomyopathy in genetically modified MYL2 mice

Dilated cardiomyopathy (DCM) is a devastating heart disease that affects about 1 million people in the United States, but the underlying mechanisms remain poorly understood. In this study, we aimed to determine the biomechanical and structural causes of DCM in transgenic mice carrying a novel mutation in the MYL2 gene, encoding the cardiac myosin regulatory light chain. Transgenic D94A (aspartic acid-to-alanine) mice were created and investigated by echocardiography and invasive hemodynamic and molecular structural and functional assessments. Consistent with the DCM phenotype, a significant reduction of the ejection fraction (EF) was observed in ~5- and ~12-mo-old male and female D94A lines compared with respective WT controls. Younger male D94A mice showed a more pronounced left ventricular (LV) chamber dilation compared with female counterparts, but both sexes of D94A lines developed DCM by 12 mo of age. The hypocontractile activity of D94A myosin motors resulted in the rightward shift of the force–pCa dependence and decreased actin-activated myosin ATPase activity. Consistent with a decreased Ca 2+ sensitivity of contractile force, a small-angle X-ray diffraction study, performed in D94A fibers at submaximal Ca 2+ concentrations, revealed repositioning of the D94A cross-bridge mass toward the thick-filament backbone supporting the hypocontractile state of D94A myosin motors. Our data suggest that structural perturbations at the level of sarcomeres result in aberrant cardiomyocyte cytoarchitecture and lead to LV chamber dilation and decreased EF, manifesting in systolic dysfunction of D94A hearts. The D94A-induced development of DCM in mice closely follows the clinical phenotype and suggests that MYL2 may serve as a new therapeutic target for dilated cardiomyopathy.

60 APPLIED LIFE SCIENCES↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

The Accordion Sign in the Transplant Ureter: Ramifications During Balloon Dilation of Strictures

PurposeThis study was designed to demonstrate the accordion sign within the transplant ureter and evaluate its ramifications during balloon dilation of strictures.MethodsA retrospective electronic chart and imaging review included demographic characteristics, procedure reports, and complications of 28 renal transplant patients having ureteral strictures treated with percutaneous balloon dilation reported in our transplant nephrology database during an 8-year period. The accordion sign was deemed present or absent on the basis of an imaging review and was defined as present when a tortuous ureter became kinked and irregular when foreshortened after placement of a wire or a catheter. Procedure-related urine leaks were categorized as occurring at the stricture if within 2 cm; otherwise, they were considered away from the stricture.ResultsThe accordion sign was associated with a significantly greater occurrence of leaks away from the stricture (P = 0.001) but not at the stricture (P = 0.34).ConclusionsThe accordion sign is an important consideration when performing balloon dilation procedures on transplant ureteral strictures, given the increased risk of leak away from the stricture. Its presence should prompt additional care during wire and catheter manipulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calcite veins as an indicator of fracture dilatancy and connectivity during strike-slip faulting in Toarcian shale (Tournemire tunnel, Southern France)

The reactivation of faults induced by natural/human induced fluid pressure increases is a major concern to explain subsurface fluid migration and to estimate the risk of losing the integrity of reservoir/seal systems. This study focusses on paleo-fluid migration in a strike slip fault with >100 m long, affecting a Toarcian shale (Causses Basin, France). A high calcite concentration is observed in a 5 cm thick zone at the boundary between the fault core and damage zone. Cumulated displacements in this zone are of millimeter-to-centimeter-scale offsets and different dilatant deformation textures are observed. The zone is affected by thin slip planes containing gouge. Cathodo-luminescence observations indicate that two phases of vein formation occurred. The first phase coincides with the fluid migration along this centimeter thick dilatant zone. The second one is associated to re-shear along the millimeter thick slip planes that results in more localized mineralization, but also in a better hydrologic connection through the shale formation. These results show that in shales fluids may migrate off a slipping surface in centimeter scale dilatant volumes, at first controlled by the intact shale anisotropy related to bedding and then favored by brecciating, structures re-orientation and strengthening processes induced by calcite sealing effects.

58 GEOSCIENCES↗

High temperature dilatation measurements by in situ laser interferometry under high magnetic field

This article contains a description of a laser interferometer coupled with a furnace for in situ dilatation measurements under high magnetic field. The apparatus fits an 18 T superconducting magnet with a 32 mm diameter room temperature bore. This optical method was chosen for dilatation measurements because it is not perturbated by the magnetic field. The measured sample can be heated up to 1500 K under a controlled atmosphere, and heating and cooling rates can be varied within a range of 10 K/s. The resolution is below 50 nm. As an example of using in situ dilatation measurements to follow phase transformations, the increase in the ferrite/austenite transformation temperature in pure iron in a magnetic field up to 16 T was experimentally evidenced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating high speed phenomena in laser plasma interactions using dilation x-ray imager (invited)

The DIlation X-ray Imager (DIXI) is a new, high-speed x-ray framing camera at the National Ignition Facility (NIF) sensitive to x-rays in the range of ≈2–17 keV. DIXI uses the pulse-dilation technique to achieve a temporal resolution of less than 10 ps, a ≈10× improvement over conventional framing cameras currently employed on the NIF (≈100 ps resolution), and otherwise only attainable with 1D streaked imaging. The pulse-dilation technique utilizes a voltage ramp to impart a velocity gradient on the signal-bearing electrons. The temporal response, spatial resolution, and x-ray sensitivity of DIXI are characterized with a short x-ray impulse generated using the COMET laser facility at Lawrence Livermore National Laboratory. At the NIF a pinhole array at 10 cm from target chamber center (tcc) projects images onto the photocathode situated outside the NIF chamber wall with a magnification of ≈64×. DIXI will provide important capabilities for warm-dense-matter physics, high-energy-density science, and inertial confinement fusion, adding important capabilities to temporally resolve hot-spot formation, x-ray emission, fuel motion, and mix levels in the hot-spot at neutron yields of up to 10{sup 17}. We present characterization data as well as first results on electron-transport phenomena in buried-layer foil experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ON THE LACK OF TIME DILATION SIGNATURES IN GAMMA-RAY BURST LIGHT CURVES

We examine the effects of time dilation on the temporal profiles of gamma-ray burst (GRB) pulses. By using prescriptions for the shape and evolution of prompt gamma-ray spectra, we can generate a simulated population of single-pulsed GRBs at a variety of redshifts and observe how their light curves would appear to a gamma-ray detector here on Earth. We find that the observer frame duration of individual pulses does not increase with redshift as 1 + z, which one would expect from cosmological expansion. This time dilation is masked by an opposite and often stronger effect: with increasing redshift and decreasing signal-to-noise ratio only the brightest portion of the light curve can be detected. The results of our simulation are consistent with the fact that the simple time dilation of GRB light curves has not materialized in either the Swift or Fermi detected GRBs with known redshift. We show that the measured durations and associated E{sub iso} estimates for GRBs detected near the instrument's detection threshold should be considered lower limits to the true values. Furthermore, we conclude that attempts at distinguishing between long and short GRBs, at even moderate redshifts, cannot be done based on a burst's temporal properties alone.

79 ASTRONOMY AND ASTROPHYSICS↗

COSMOLOGICAL TIME DILATION IN DURATIONS OF SWIFT LONG GAMMA-RAY BURSTS

Cosmological time dilation is a fundamental phenomenon in an expanding universe, which stresses that both the duration and wavelength of the emitted light from a distant object at the redshift z will be dilated by a factor of 1 + z at the observer. By using a sample of 139 Swift long gamma-ray bursts with known redshift (z ≤ 8.2), we measure the observed duration (T {sub 90}) in the observed energy range between 140/(1 + z) keV and 350/(1 + z) keV, corresponding to a fixed energy range of 140-350 keV in the rest frame. We obtain a significant correlation between the duration and the factor 1 + z, i.e., T {sub 90} = 10.5(1 + z){sup 0.94} {sup ±} {sup 0.26}, which is consistent with that expected from the cosmological time dilation effect.

79 ASTRONOMY AND ASTROPHYSICS↗

Warping with dilatation symmetry and self-tuning of the cosmological constant

We investigate consequences of an ultraviolet fixed point in quantum gravity for the cosmological constant. For this purpose we perform dimensional reduction of a general dilatation-symmetric effective action {Gamma} in dimension d>4 to an effective four-dimensional theory of gravity with a dilaton field. We find a stable flat phase in the space of the extrema of {Gamma} which results in a vanishing four-dimensional cosmological constant {Lambda}. In order to understand the self-tuning mechanism leading to {Lambda}=0 we discuss in detail the most general warped geometries with maximal four-dimensional symmetry and SO(d-4) isometry of internal space. While the solutions of the d-dimensional field equations admit singular spaces with arbitrary {Lambda}, the extremum condition for {Gamma} imposes additional restrictions which result in {Lambda}=0. In cosmology, the dilatation-symmetric fixed point may only be reached for asymptotic time t{yields}{infinity}. At finite t dilatation anomalies result in an effective potential and mass for the pseudodilaton or cosmon and in dark energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On The Lack of Time Dilation Signatures in Gamma-ray Burst Light Curves

We examine the effects of time dilation on the temporal profiles of gamma-ray burst (GRB) pulses. By using prescriptions for the shape and evolution of prompt gamma-ray spectra, we can generate a simulated population of single pulsed GRBs at a variety of redshifts and observe how their light curves would appear to a gamma-ray detector here on Earth. We find that the observer frame duration of individual pulses does not increase with redshift as 1 = z that one would expect from the cosmological expansion. This time dilation is masked by an opposite and often stronger effect which is that with increasing redshift and decreasing signal-to-noise ratio only the brightest portion of the light curve can be detected. The results of our simulation are consistent with the fact that the simple time dilation of GRB light curves has not materialized in either the Swift or Fermi detected GRBs with known redshift. We show that the measured durations and associated E iso estimates for GRBs detected near the instrument’s detection threshold should be considered lower limits to the true values. Furthermore, we conclude that attempts at distinguishing between long and short GRBs, at even moderate redshifts, cannot be done based on a burst’s temporal properties alone.

ASTRO↗