Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct counts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Post-Flight Microbial Analysis of Samples from the International Space Station Water Recovery System and Oxygen Generation System

The Regenerative, Environmental Control and Life Support System (ECLSS) on the International Space Station (ISS) includes the the Water Recovery System (WRS) and the Oxygen Generation System (OGS). The WRS consists of a Urine Processor Assembly (UPA) and Water Processor Assembly (WPA). This report describes microbial characterization of wastewater and surface samples collected from the WRS and OGS subsystems, returned to KSC, JSC, and MSFC on consecutive shuttle flights (STS-129 and STS-130) in 2009-10. STS-129 returned two filters that contained fluid samples from the WPA Waste Tank Orbital Recovery Unit (ORU), one from the waste tank and the other from the ISS humidity condensate. Direct count by microscopic enumeration revealed 8.38 x 104 cells per mL in the humidity condensate sample, but none of those cells were recoverable on solid agar media. In contrast, 3.32 x lOs cells per mL were measured from a surface swab of the WRS waste tank, including viable bacteria and fungi recovered after S12 days of incubation on solid agar media. Based on rDNA sequencing and phenotypic characterization, a fungus recovered from the filter was determined to be Lecythophora mutabilis. The bacterial isolate was identified by rDNA sequence data to be Methylobacterium radiotolerans. Additional UPA subsystem samples were returned on STS-130 for analysis. Both liquid and solid samples were collected from the Russian urine container (EDV), Distillation Assembly (DA) and Recycle Filter Tank Assembly (RFTA) for post-flight analysis. The bacterium Pseudomonas aeruginosa and fungus Chaetomium brasiliense were isolated from the EDV samples. No viable bacteria or fungi were recovered from RFTA brine samples (N= 6), but multiple samples (N = 11) from the DA and RFTA were found to contain fungal and bacterial cells. Many recovered cells have been identified to genus by rDNA sequencing and carbon source utilization profiling (BiOLOG Gen III). The presence of viable bacteria and fungi from WRS and OGS subsystems demonstrates the need for continued monitoring of ECLSS during future ISS operations and investigation of advanced antimicrobial controls.

Birmele, Michele N.↗

Designing Lightweight Neutron Absorbing Composites Using a Comprehensive Absorber Areal Density Metric

Efforts to lightweight neutron absorbing composites are limited by incomplete understandings of the interaction between absorbing particles and their matrices. In this study, analytical models and a more physically representative simulation evaluated the penalty to neutron absorbing performance due to neutron channeling between large absorbing particles. Models and simulation agreed that B 4 C particles smaller than 100μm and especially those smaller than 10μm did not cause excessive neutron channeling. A more comprehensive neutron absorbing composite design metric – boron-10 equivalent areal density, which considers the particle size penalty and the matrix contribution to absorptivity – was introduced and used to estimate lightweighting via matrix substitution. Calculations using this new metric showed that a non-absorbing Mg matrix reduced mass by up to 35% over Al, constrained by the difference in mass density, while an absorbing Mg–Li matrix reduced mass by up to 60%, exceeding the difference in mass densities alone. Measurement of apparent absorber areal density through two experimental techniques – foil activation and direct counting – validated estimated absorber areal density as a neutron absorbing composite design metric. This updated understanding of the particle size penalty, newly introduced design metric, and experimental validation demonstrate a path to lightweight neutron absorbing composites.

Radiation shielding↗

Rapid enumeration of viable bacteria by image analysis

A direct viable counting method for enumerating viable bacteria was modified and made compatible with image analysis. A comparison was made between viable cell counts determined by the spread plate method and direct viable counts obtained using epifluorescence microscopy either manually or by automatic image analysis. Cultures of Escherichia coli, Salmonella typhimurium, Vibrio cholerae, Yersinia enterocolitica and Pseudomonas aeruginosa were incubated at 35 degrees C in a dilute nutrient medium containing nalidixic acid. Filtered samples were stained for epifluorescence microscopy and analysed manually as well as by image analysis. Cells enlarged after incubation were considered viable. The viable cell counts determined using image analysis were higher than those obtained by either the direct manual count of viable cells or spread plate methods. The volume of sample filtered or the number of cells in the original sample did not influence the efficiency of the method. However, the optimal concentration of nalidixic acid (2.5-20 micrograms ml-1) and length of incubation (4-8 h) varied with the culture tested. The results of this study showed that under optimal conditions, the modification of the direct viable count method in combination with image analysis microscopy provided an efficient and quantitative technique for counting viable bacteria in a short time.

Non-NASA Center↗

Rapid in situ assessment of physiological activities in bacterial biofilms using fluorescent probes

Two rapid in situ enumeration methods using fluorescent probes were used to assess the physiological activities of Klebsiella pneumoniae biofilms on stainless steel. Fluorescent dyes, 5-cyano-2,3-ditolyl tetrazolium chloride (CTC) and rhodamine 123 (Rh 123), were chosen to perform this study. CTC is a soluble redox indicator which can be reduced by respiring bacteria to fluorescent CTC-formazan crystals. Rh 123 is incorporated into bacteria with respect to cellular proton motive force. The intracellular accumulation of these fluorescent dyes can be determined using epifluorescence microscopy. The results obtained with these two fluorescent probes in situ were compared to the plate count (PC) and in situ direct viable count (DVC) methods. Viable cell densities within biofilms determined by the three in situ methods were comparable and always showed approximately 2-fold higher values than those obtained with the PC method. As an additional advantage, the results were observed after 2 h, which was shorter than the 4 h incubation time required for the DVC method and 24 h for colony formation. The results indicate that staining with CTC and Rh 123 provides rapid information regarding cell numbers and physiological activities of bacteria within biofilms.

NASA Discipline Number 04-10↗

Radionuclide counting technique for measuring wind velocity and direction

An anemometer utilizing a radionuclide counting technique for measuring both the velocity and the direction of wind is described. A pendulum consisting of a wire and a ball with a source of radiation on the lower surface of the ball is positioned by the wind. Detectors and are located in a plane perpendicular to pendulum (no wind). The detectors are located on the circumferene of a circle and are equidistant from each other as well as the undisturbed (no wind) source ball position.

Singh, J. J.↗

Comparison of epifluorescent viable bacterial count methods

Two methods, the 2-(4-Iodophenyl) 3-(4-nitrophenyl) 5-phenyltetrazolium chloride (INT) method and the direct viable count (DVC), were tested and compared for their efficiency for the determination of the viability of bacterial populations. Use of the INT method results in the formation of a dark spot within each respiring cell. The DVC method results in elongation or swelling of growing cells that are rendered incapable of cell division. Although both methods are subjective and can result in false positive results, the DVC method is best suited to analysis of waters in which the number of different types of organisms present in the same sample is assumed to be small, such as processed waters. The advantages and disadvantages of each method are discussed.

Rodgers, E. B.↗

The use of multiple indices of physiological activity to access viability in chlorine disinfected Escherichia coli O157:H7

A suite of fluorescent intracellular stains and probes was used, in conjunction with viable plate counts, to assess the effect of chlorine disinfection on membrane potential (rhodamine 123; Rh123 and bis-(1,3-dibutylbarbituric acid) trimethine oxonol; DiBAC4(3)), membrane integrity (LIVE/DEAD BacLight kit), respiratory activity (5-cyano-2,3-ditolyl tetrazolium chloride; CTC) and substrate responsiveness (direct viable counts; DVC) in the commensal pathogen Escherichia coli O157:H7. After a 5 min exposure to the disinfectant, physiological indices were affected in the following order: viable plate counts > substrate responsiveness > membrane potential > respiratory activity > membrane integrity. In situ assessment of physiological activity by examining multiple targets, as demonstrated in this study, permits a more comprehensive determination of the site and extent of injury in bacterial cells following sublethal disinfection with chlorine. This approach to assessing altered bacterial physiology has application in various fields where detection of stressed bacteria is of interest.

NASA Discipline Environmental Health↗

Advection from the North Atlantic as the Forcing of Winter Greenhouse Effect Over Europe

In winter, large interannual fluctuations in the surface skin temperature are observed over central Europe: we observe a difference of 9.8 K comparing warm February 1990 with cold February 1996 for the region 50-60 degrees N; 5-35 degrees E. Previous studies show that advection from the North Atlantic constitutes the forcing to such fluctuations. The advection is quantified by Index I(sub na), the average of the ocean-surface wind speed over the eastern North Atlantic when the direction is from the southwest (when the wind is from another direction, it counts as a zero speed to the average). Average Ina for February 1990 was 10.6 in s(exp -1), but for February 1996 I(sub na) was only 2.4 m s(exp -1). A large value of I(sub na) means a strong southwesterly flow which brings warm and moist air into Europe at low level, producing a steeper tropospheric lapse rate. Strong ascending motions result, which we observe in February 1990 at 700 mb. The near-surface moisture rises to higher (and cooler) levels, producing clouds and precipitation. Total preciptable water and cloud-cover fraction have larger values in February 1990 than in 1996. The difference in the greenhouse effect between these two scenarios can be translated into a virtual irradiating source of 2.6 W m(exp -2) above the February 1990 atmosphere, which, as an order of magnitude estimate, contributes to the warming of the surface by 2.6 K. If we accept this estimate as numerically pertinent, the direct effect stands as 7.2 K (9.8 K - 2.6 K), and therefore its greenhouse-effect reinforcement is by 36%. This constitutes a substantial positive feedback to the direct effect, which is the inflow of warm air to the low troposphere over Europe.

Otterman, Jay↗

Advection from the North Atlantic as the Forcing of Winter Greenhouse Effect Over Europe

In winter, large interannual fluctuations in the surface temperature are observed over central Europe. Comparing warm February 1990 with cold February 1996, a satellite-retrieved surface (skin) temperature difference of 9.8 K is observed for the region 50-60 degrees N; 5-35 degrees E. Previous studies show that advection from the North Atlantic constitutes the forcing to such fluctuations. The advection is quantified by Index I(sub na), the average of the ocean-surface wind speed over the eastern North Atlantic when the direction is from the southwest (when the wind is from another direction, it counts as a zero speed to the average). Average I(sub na) for February 1990 was 10.6 m/s, but for February 1996 I(sub na) was only 2.4 m/s. A large value of I(sub na) means a strong southwesterly flow which brings warm and moist air into central Europe at low level, producing a steeper tropospheric lapse rate. Strong ascending motions at 700 mb are observed in association with the occurrence of enhanced warm, moist advection from the ocean in February 1990 producing clouds and precipitation. Total precipitable water and cloud-cover fraction have larger values in February 1990 than in 1996. The difference in the greenhouse effect between these two scenarios, this reduction in heat loss to space, can be translated into a virtual radiative heating of 2.6 W/square m above the February 1990 surface/atmosphere system, which contributes to a warming of the surface on the order of 2.6 K. Accepting this estimate as quantitatively meaningful, we evaluate the direct effect, the rise in the surface temperature in Europe as a result of maritime-air inflow, as 7.2 K (9.8 K-2.6 K). Thus, fractional reinforcement by the greenhouse effect is 2.6/7.2, or 36%, a substantial positive feedback.

Otterman, J.↗

Laser interferometer micrometer system

Laser micrometer measures dimensions of precision gyro and gas bearing parts using the principle of measuring light phase changes rather than a direct fringe count. The system uses light beams to eliminate errors due to deformations and surface irregularities, and three interferometers.

Logue, S. H.↗

The crater density of a linear feature

The standard method of crater counting presently employed permits determination of the relative ages of areal geologic features on cratered planets and satellites. A new method is presented which calculates the areal density of the craters superposed upon linear features. The method produces an effective synthetic area around the linear feature for each crater bin size, permitting the line counts to be compared directly with standard area counts. The shape of the synthetic area produced by the method is an oval, with the calculation of this area for each in being dependent on the median crater size for that bin, as well as the length and width of the linear feature. Incorporated into the method's equation is a factor to normalize the count to one million square kilometers for each bin. Because of the dependence of the method on the crater sizes, the largest possible number of bins should be counted for the method to be the most effective.

Spong, L.↗

Development anmd testing of electrophoresis solutions. Task I.1: Development of optimal buffer system

Two buffers were explored for testing: low ionic strength electrophoresis buffer with and without density gradient material. It was found that the electrophoresis routine was better tolerated when Ficoll was present. The results of a viability study of primary human fetal kidney (HFK-1) cells at the first passage are shown. Cell strain HFK-1 was used in several experiments at the first and second passage. The HFK consisted mainly of fibroblasts, and HFK-1 has a high epithelioid cell content. The chromosomes of HFK were examined and found to be euploid. The stock medium for cell electrophoresis is described. In this solution density gradient solutes such as sucrose and Ficoll are dissolved to bring the osmolarity to 0.30. Its ionic strength is less than 0.01M, and its conductivity is usually 0.0011 mho/cm. Methods for viability determination included direct microscopic counting of the percent cells attached and spread within 24 hr of plating test cultures or electrophoretically separated fractions. The Cytograf viability assay concept was tested, and shown that blue stained cells scatter less light into the 0.8 to 3.3 deg angular interval than do unstained cells.

Source record↗

Measuring Transmission Efficiencies Of Mass Spectrometers

Coincidence counts yield absolute efficiencies. System measures mass-dependent transmission efficiencies of mass spectrometers, using coincidence-counting techniques reminiscent of those used for many years in calibration of detectors for subatomic particles. Coincidences between detected ions and electrons producing them counted during operation of mass spectrometer. Under certain assumptions regarding inelastic scattering of electrons, electron/ion-coincidence count is direct measure of transmission efficiency of spectrometer. When fully developed, system compact, portable, and used routinely to calibrate mass spectrometers.

Srivastava, Santosh K.↗

Microbial colonization of a closed growth chamber during hydroponic cultivation of lettuce

The goal of this study was to characterize sessile and planktonic microbiota that developed during two successive hydroponic cultures of lettuce in a closed chamber system. Coupons of polyvinyl chloride (PVC) placed in the nutrient solution lines were removed periodically, as were samples of the nutrient solutions and condensate from the air-handling system. The bacteria and fungi present on the coupons and in fluid samples were enumerated by direct plate counts. Disinfecting the hydroponic system with 0.1% hypochlorite and 0.1 N nitric acid reduced the bacterial densities in biofilm samples from 1 x 10 7 CFU/10 cm 2 to 1 x 10 1 CFU/10 cm 2 and eliminated culturable fungi; Staphylococcus sp., Pseudomonas sp., and Micrococcus sp. survived this procedure. Bacterial and fungal concentrations in all samples returned to predisinfection levels after 2 days of plant growth. Pseudomonas and Acremonium predominated both before and after disinfection. Fungal concentrations never exceeded 7 x 10 2 CFU/10 cm 2 . The coupon microbiota differed from that of the rhizoplane at harvest. Overall, the greatest numbers of species were found on the rhizoplane samples collected during the second crop. The microbial community changed little during individual crops or between successive crops. Diversity indices remained relatively constant for all samples.

Bacteria growth & development↗

Increasing Density and Reducing Costs of Data Acquisition

There are a number of reasons why it is important to increase the density of data acquisition functions. Sensor fusion seeks to integrate large numbers of sensors into a decision network. Addition of health monitoring functions may incur additional sensor requirements. But at the same time, it is important to reduce the per-channel costs of data acquisition systems. Often the most significant cost is the management of data acquisition networks, which incurs substantial costs associated with transducer installation, configuration, calibration, and maintenance. Alternatives that lower the cost of the transducer system and reduce the data acquisition system channel count will directly impact initial system costs. Other techniques that affect maintenance and operating costs will contribute to reducing life cycle costs. This paper describes work undertaken to explore alternative architectures for lowering the cost per transducer function using a MEMS-based accelerometer as the model.

Schmalzel, J. L.↗