Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct load control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Systems and methods for randomized energy draw or supply requests

The present disclosure can provide a distributed and anonymous approach to demand response of an electricity system. The approach can conceptualize energy consumption and production of distributed-energy resources (DERs) via discrete energy packets that are coordinated by a cyber computing entity that grants or denies energy packet requests from the DERs. The approach leverages a condition of a DER, which is particularly useful for (1) thermostatically-controlled loads, (2) non-thermostatic conditionally-controlled loads, and (3) bi-directional distributed energy storage systems, among others. In a first aspect of the present approach, each DER independently requests the authority to switch on for a fixed amount of time (i.e., packet duration). The coordinator determines whether to grant or deny each request based electric grid and/or energy or power market conditions. In a second aspect, bi-directional DERs, such as distributed-energy storage systems (DESSs) are further able to request to supply energy to the grid.

Frolik, Jeff↗

Leveraging Computational Storage Devices in Campaign Storage [Slides]

Computational storage provides new ways of accelerating data-intensive applications. In-drive data management schemes matter (O_DIRECT, clustered index). Layer violation: “cheating” one filesystem may be possible; cheating multiple layers of filesystems is hard (FS internal load balancing, fail over, compression, concurrency control). The future directions include block-based acceleration to object-based acceleration.

97 MATHEMATICS AND COMPUTING↗

Wind Turbine Gust Load Alleviation with Active Flow Control

Large wind turbine rotors are becoming more common in utility-scale wind power, especially for offshore wind plants. However, the trend toward large rotors can be limited by their ability to manage dynamic and extreme loads. To provide a safety margin for the rotor design and avoid catastrophic events such as tower strikes, extreme loads need to be controlled. The objective of this study is to develop and evaluate a feedback control system to alleviate extreme loads and reduce blade deflections under gust events using active flow control devices. We also propose a modification in the turbine controller to achieve further reduction in extreme loads. The extreme load reductions are evaluated under gust wind conditions with direction changes according to the IEC standard. The effects of the gust alleviation controller on turbine performance and fatigue loads are investigated as well. With the deployment of the gust alleviation controller and modified turbine baseline controller, the extreme loads and deflections reduce by up to 23%. The energy captured by the turbine is not affected by the proposed gust alleviation controller. The fatigue loads of various wind turbine components are either reduced or remain unchanged.

17 WIND ENERGY↗

Constrained power reference control for wind turbines

The cost of wind energy can be reduced by controlling the power reference of a turbine to increase energy capture, while maintaining load and generator speed constraints. We apply standard torque and pitch controllers to the direct inputs of the turbine and use their set points to change the power output and reduce generator speed and blade load transients. A power reference controller increases the power output when conditions are safe and decreases it when problematic transient events are expected. Transient generator speeds and blade loads are estimated using a gust measure derived from a wind speed estimate. A hybrid controller decreases the power rating from a maximum allowable power. Compared to a baseline controller, with a constant power reference, the proposed controller results in generator speeds and blade loads that do not exceed the original limits, increases tower fore-aft damage equivalent loads by 1%, and increases the annual energy production by 5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Durable Thin‐Film Porous Transport Electrodes for High Current Density PEM Water Electrolysis

Proton exchange membrane water electrolyzers rely on relatively expensive Ir-based catalysts for efficient and durable hydrogen production. To reduce system costs, Ir loadings can be reduced if performance and durability are maintained. Sputter deposition is a readily scalable method to synthesize uniform, low-loading catalyst layers with controlled composition. A catalyst applied directly to the porous transport layer can have advantages for performance, manufacturing simplicity, and catalyst recovery. Suitable porous transport layer porosity can minimize activity losses when reducing loadings. Here, methods are presented to deposit metallic Ir as well as amorphous and rutile Ir oxides. The activity and durability of these materials in the porous transport electrode architecture is evaluated. The metallic and amorphous forms have better initial activity, however, operation at 3 A cm −2 with 0.1 mg Ir cm −2 shows that only rutile IrO 2 maintains performance beyond 100 h with a 50 mV improvement after 700 h. A >10x reduced dissolution rate is shown for rutile IrO 2 . With a low-porosity transport layer and 0.4 mg Ir cm −2 , a steady-state voltage decay rate of 6 µV h −1 is achieved. The results demonstrate that sputter-deposited rutile IrO 2 porous transport electrodes with low Ir loading can be operated at high current density to reduce hydrogen production costs.

08 HYDROGEN↗

Decentralized Distribution System Restoration with Grid-Forming/Following Inverter-Based Resources

The high penetration of distributed energy resources (DERs) in active distribution systems has posed challenges to the centralized distribution system restoration (DSR) strategies in current practice. On the other hand, the advancement in smart inverter technologies enables the bottom-up restoration capability. This paper is motivated to develop a 3-layered hierarchical framework for decentralized DSR, based on the grid-forming (GFM) and grid-following (GFL) grid-edge inverters. The first layer presents the tertiary control, which determines the load pickup schedule and generation dispatch of DERs, using the alternating direction method of the multipliers algorithm. The second layer consists of two control functions: GFM control, which regulates voltage and frequency, establishing a stable grid for GFL inverters to follow; and GFL control, which regulates the real and reactive power. In the third layer, the primary control is proposed to regulate the inverter voltage and current, which is developed based on the virtual oscillator control (VOC). Furthermore, the developed framework is tested in the modified IEEE 13-node test feeder. Two scenarios of grid-connected and islanded operating modes are designed, and simulation results demonstrate the effectiveness of decentralized DSR strategies for controlling grid-edge inverters to enhance the distribution system resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review of wake management techniques for wind turbines

Summary The progression of wind turbine technology has led to wind turbines being incredibly optimized machines often approaching their theoretical maximum production capabilities. When placed together in arrays to make wind farms, however, they are subject to wake interference that greatly reduces downstream turbines' power production, increases structural loading and maintenance, reduces their lifetimes, and ultimately increases the levelized cost of energy. Development of techniques to manage wakes and operate larger and larger arrays of turbines more efficiently is now a crucial field of research. Herein, four wake management techniques in various states of development are reviewed. These include axial induction control, wake steering, the latter two combined, and active wake control. Each of these is reviewed in terms of its control strategies and use for power maximization, load reduction, and ancillary services. By evaluating existing research, several directions for future research are suggested.

17 WIND ENERGY↗

A Hardware Platform for Studying Naval Power Electronic Power Distribution Systems

Abstract – Future intelligent ship system designs will likely include electric propulsion, numerous highpower sensors, and directed energy weapons. Supply and control of these large nonlinear loads will require a networked, multi-converter power electronic power distribution system. This work presents a hardware platform to emulate a microgrid power system with multiple power converters and a power data communication network. The platform is reconfigurable and can include both AC and DC power distribution zones, representative of shipboard power systems. It also allows for the study of both power control actuation and power data communication delays. Since the platform is based on electric power hardware, spatial and temporal uncertainties are inherently embedded in the system. Specifically, this work examines the control actuation of multiple pulsed power loads in a single microgrid. Several pulse load levels and operating scenarios have been implemented and measured. A framework for control parameter quantification is presented, and various metrics are explored to capture pulse signal characteristics. The sensitivity of pulse load metric parameters is analyzed. Dynamic shipboard, mission-specific load profiles coupled with pulse loads can also be emulated in the hardware platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geothermal-integrated thermally anisotropic building envelope for energy and peak-demand reduction

Buildings consume large amounts of energy for heating and cooling, while peak electricity demand places significant stress on the power grid. This paper presents a reduced-order co-simulation framework and load-oriented supervisory control strategy for a geothermal-integrated thermally anisotropic building envelope with a ground loop (TABE+GL). In TABE+GL, a hydronic loop embedded in the building envelope is directly coupled with a geothermal ground loop, allowing for bidirectional heat exchange between the envelope, the ground, and the indoor environment. A hybrid co-simulation framework was established by coupling a reduced-order resistor–capacitor (RC) thermal network model with EnergyPlus augmented with GHEDesigner modules. The RC model generated feasible heat flux options under three operating modes, and EnergyPlus predicted sensible loads, energy use, and pump energy demand. At each simulation step, a supervisory control algorithm selected the optimal loop configuration and duty factor that maximizes useful TABE geothermal utilization without exceeding the predicted sensible load, thereby avoiding overheating or cooling. Case studies were conducted for Los Angeles, California, Charleston, South Carolina, and Denver, Colorado. Results showed that the proposed framework reduced HVAC electricity consumption by 43%–67%, natural gas use for space heating by 11%–38%, and peak electricity demand by 43%–88%. These results highlight the potential of combining reduced-order envelope modeling, direct geothermal coupling, and load-oriented supervisory control to improve whole building energy performance and reduce peak demand across diverse weather conditions.

Howard, Daniel [Southern Adventist University]↗

A machine learning-based fast frequency response control for a VSC-HVDC system

An HVDC system can realize a very fast frequency response to the disturbed system under a contingency because its active power control is decoupled from the frequency deviation. However, most of existing HVDC frequency control strategies are coupled with system primary frequency control and secondary frequency control. Since the traditional system frequency control is dominated by the thermal generators, the advantage of the fast response of the HVDC system is not made fully used. The development of a frequency response estimation based on a machine learning algorithm provides another approach to improve the frequency response capability of the HVDC system. Different from other frequency deviation tracking strategies, a machine learning based HVDC frequency response control can directly increase the power flow of a HVDC system by estimation of the system generator or load lost. In this paper, a fast frequency response control using a HVDC system for a large power system disturbance based on the multivariate random forest regression (MRFR) algorithm is proposed. The simulation is carried out with an integrated power system model based on the North American interconnections. The simulation results indicate that the proposed MRFR based frequency response control can significantly improve the frequency low point during an event, while stabilizing the frequency in advance.

42 ENGINEERING↗

AlphaBuilding ResCommunity: A multi-agent virtual testbed for community-level load coordination

Training and validating algorithms in a simulation testbed can accelerate research and applications of optimal control of residential loads to improve energy flexibility and grid resilience. We developed an open-source simulation environment, AlphaBuilding ResCommunity, that can be used to train and validate algorithms to control a single thermostatically controlled load (TCL) or coordinate a group of TCLs. We used reduced-order models to simulate the thermodynamics of TCLs, and the parameter values were determined from the connected smart thermostat data of real households. The environment was built upon the standardized OpenAI Gym interface. Ancillary functions, such as retrieving the parameters and weather forecasts, are provided to facilitate control strategies that require predictive information. Compared with existing efforts, AlphaBuilding ResCommunity has three advantages: (1) more realistic model settings because the parameter values are identified from actual household operating data, and modelling and measurement uncertainty are considered; (2) passive thermal storage control; and (3) ease of use due to a simple software dependency and standardized interface. We demonstrated the applications of the environment by implementing a Kalman Filter and Model Predictive Control on a single TCL and a Priority-Stack-Based Control and Alternating Direction Method of Multipliers to coordinate multiple TCLs for load tracking.

Wang, Z↗

Overcoming the Technical Challenges of Coordinating Distributed Load Resources at Scale (Final Report)

Significant recent research has investigated the potential for loads to provide balancing services to the grid. However, this research has not addressed key issues that may arise when such schemes are applied at scale including: 1. Distribution Network Issues. Coordination of large numbers of loads could result in power flows that violate distribution network constraints; 2. Stability Issues. Certain strategies to control loads can exhibit nonlinearity in the form of period-adding bifurcations and chaos. Other control strategies can potentially synchronize the behavior of large numbers of loads. In both cases, the outcome can be power oscillations and instability; 3. Communication Network Issues. Bidirectional low-latency communication channels between a central controller (or several distributed controllers) and each resource are expensive and likely not necessary for effective coordination. Our research questions were: What network, stability, and communication issues might arise in practice when we coordinate large aggregations of loads? How can we coordinate loads to achieve performance objectives in a cost effective manner while avoiding these issues? The ultimate technical goal of the project was the development of network-aware, communication-constrained, non-disruptive load control strategies with stability guarantees that achieve the performance requirements of typical balancing services at a sufficiently low cost to enable the load aggregator and customer to profit. The overall goal was to establish credibility for load control at scale and contribute to U.S. energy security and environmental goals. The team succeeded in answering these research questions and developing these control strategies. The overall approach was based on the development of three testing environments: a simulation testbed, an experimental testbed (20 physical model houses with window-box air conditioners) coupled with the simulation testbed, and a field testbed (100 actual homes in Austin, TX) coupled with the simulation testbed, which enabled controller testing, identification of issues, controller development, and controller validation. The resulting controller was used to demonstrate fast timescale grid balancing (frequency regulation) by aggregations of physical and virtual air conditioners, with sufficient quality to participate in the electricity market. Cost benefit analysis showed overall benefits to the participating households, load aggregators, and the grid, especially if the control technology was integrated directly into existing programmable communicating thermostats. The project provides a variety of wider benefits. Our technology transfer and outreach activities lead us to choose an open-source licensing commercialization pathway, enabling the project results to be available to researchers, industry, and the public. Furthermore, new grid balancing technologies will increase grid flexibility and will enable higher penetrations of intermittent renewable energy resources, such as wind and solar, to be connected to the grid, reducing its environmental impact, and mitigating climate change to the benefit of society.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Fabrication of a Thyristor Using Ion Implantation of Anode and Cathode

A thyristor is a solid-state semiconductor switch made up of four alternating p and n type layers. When the switch is turned on by a small pulse, current can flow as long as the device stays on. When the voltage drops below the turn on level or the current reverses, the switch will turn off. Thyristors only allow current to flow in one direction. One of the benefits of a thyristor device is in its capacity to conduct large voltages with a small device and a small turn-on pulse requirement. Another distinguishing feature of thyristors compared to other semiconductor devices is that it can only be in the on or off state, there’s no in-between state for the device to exist within. These properties make thyristors very useful as switch devices, especially in applications where current flow is only needed in one direction and could potentially be damaging in the opposite direction. Currently, thyristors are most commonly used to control very high power loads and they are available commercially in many designs to control different amounts of current.

42 ENGINEERING↗

Advancing Concentrating Solar Thermal Modeling Using System Advisor Model (SAM)

Concentrating solar thermal (CST) technologies play a critical role in enabling dispatchable power and high-temperature industrial heat applications. Accurate and flexible modeling tools are essential for evaluating system performance, guiding technology research and development, and informing investment decisions. The National Laboratory of the Rockies's System Advisor Model (SAM) is a widely used techno-economic simulation platform for CST systems, providing detailed performance and financial modeling capabilities for multiple CST system configurations. SAM integrates physics-based performance models with financial analysis to simulate the behavior of complex energy systems under realistic operating conditions. For CST technologies (including tower, parabolic trough, and linear Fresnel), SAM enables hourly simulations using site-specific weather data that ensure feasible operating conditions and convergence of mass and energy between core system components (i.e., solar field, receiver, thermal energy storage, and power cycle). These capabilities allow researchers and developers to evaluate annual energy production, capacity factors, levelized cost of energy (LCOE), and system dispatch strategies. A key advantage of SAM lies in its flexibility for parametric analysis and large-scale computational studies. Users can vary system design parameters such as heliostat field layout, receiver dimensions, thermal energy storage capacity, power block sizing, and installation cost assumptions to investigate their impact on system performance and financial metrics. When combined with automated scripting through LK, SDKTool, or Python interfaces, SAM enables high-throughput simulation workflows that support sensitivity analysis, technology benchmarking, and optimization studies. These approaches are particularly valuable for next-generation CST concepts, where design spaces are large and system interactions are complex. Another important capability of SAM is its support for dispatch optimization and thermal energy storage modeling, which are central to the value proposition of CST technologies. The ability to simulate integrated storage and flexible power generation allows researchers to explore strategies that maximize grid value, improve capacity utilization, and enhance integration with variable resources such as photovoltaic and wind generation. This poster will present an overview of SAM's thermal system modeling capabilities including concentrating solar. Additionally, we will highlight new feature developments including: 1) implementing Google's OR-Tools optimization platform for faster and more robust dispatch optimization, 2) developing a new power load following controller for modeling behind-the-meter applications, 3) enabling direct modeling of CSP-PV hybrid systems with the inclusion of battery storage, and 4) developing a multi-receiver falling particle Gen3 system model.

14 SOLAR ENERGY↗

Increased power gains from wake steering control using preview wind direction information

Abstract. Yaw controllers typically rely on measurements taken at the wind turbine, resulting in a slow reaction to wind direction changes and subsequent power losses due to misalignments. Delayed yaw action is especially problematic in wake steering operation because it can result in power losses when the yaw misalignment angle deviates from the intended one due to a changing wind direction. This study explores the use of preview wind direction information for wake steering control in a two-turbine setup with a wind speed in the partial load range. For these conditions and a simple yaw controller, results from an engineering model identify an optimum preview time of 90 s. These results are validated by forcing wind direction changes in a large-eddy simulation model. For a set of six simulations with large wind direction changes, the average power gain from wake steering increases from only 0.44 % to 1.32 %. For a second set of six simulations with smaller wind direction changes, the average power gain from wake steering increases from 1.24 % to 1.85 %. Low-frequency fluctuations are shown to have a larger impact on the performance of wake steering and the effectiveness of preview control, in particular, than high-frequency fluctuations. From these results, it is concluded that the benefit of preview wind direction control for wake steering is substantial, making it a topic worth pursuing in future work.

17 WIND ENERGY↗

The influence of molecular design on structure–property relationships of a supramolecular polymer prodrug

Supramolecular self-assemblies of hydrophilic macromolecules functionalized with hydrophobic, structure-directing components have long been used for drug delivery. In these systems, loading of poorly soluble compounds is typically achieved through physical encapsulation during or after formation of the supramolecular assembly, resulting in low encapsulation efficiencies and limited control over release kinetics, which are predominately governed by diffusion and carrier degradation. To overcome these limitations, amphiphilic prodrugs that leverage a hydrophobic drug as both the therapeutic and structure-directing component can be used to create supramolecular materials with higher loading and controlled-release kinetics using biodegradable or enzymatically cleavable linkers. Here, we report the design, synthesis, and characterization of a library of supramolecular polymer prodrugs based on poly(ethylene glycol) (PEG) and the proregenerative drug 1,4-dihydrophenonthrolin-4-one-3-carboxylic acid (DPCA). Structure–property relationships were elucidated through experimental characterization of prodrug behavior in both the wet and dry states using scattering techniques and electron microscopy and corroborated by coarse-grained modeling. Molecular architecture and the hydrophobic-to-hydrophilic ratio of PEG–DPCA conjugates strongly influenced their physical state in water, ranging from fully soluble to supramolecular spherical assemblies and nanofibers. Molecular design and supramolecular structure, in turn, were shown to dramatically alter hydrolytic and enzymatic release and cellular transport of DPCA. In addition to potentially expanding therapeutic options for DPCA through control of supramolecular assemblies, the design principles elaborated here may inform the development of other supramolecular prodrugs based on hydrophobic small-molecule compounds.

77 NANOSCIENCE AND NANOTECHNOLOGY↗