Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct-use heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Techno-Economic Analysis for a Potential Geothermal District Heating System in Tuttle, Oklahoma

Geothermal deep direct use (DDU) has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for a large-scale and variable heat demand. The National Renewable Energy Laboratory (NREL) and University of Oklahoma evaluated the feasibility of a geothermal district heating (GDH) and cooling system in two schools and 250 houses by utilizing existing oil and gas (O&G) wells in Tuttle, Oklahoma. Heating and cooling demand in the two schools and a typical single-family house were modeled using EnergyPlus building energy simulation software. The modeling results indicated that annual heating demand in two schools and 250 houses is approximately 2.61 GWhth, and cooling demand in the two schools is approximately 2.65 GWhth. In this scope, the techno-economic analysis (TEA) was conducted using the GEOPHIRES tool combined with the TOUGH2 reservoir simulator. The reservoir performance, including geothermal heat production capacity, was modeled by the reservoir simulator TOUGH2. Then, levelized cost of heat (LCOH) was calculated using GEOPHIRES version 3.0, which includes new features such as hourly heat load optimization and peak performance evaluation. Geothermal reservoir temperature was estimated as 90.5 degrees C at a total depth of 3.3 km by the regional average temperature gradient of 22.8 degrees C/km and validated by cation geothermometer calculations. Four production scenarios with two different well configurations and two different heat load profiles have been developed for well flow rates ranging between 3.1 kg/s and 9.3 kg/s. The LCOH of the district heating and cooling system was calculated between $95 and $210/MWh ($28/MMBtu to $62/MMBtu) for four different production scenarios. Typical natural gas prices for residential customers in Oklahoma have ranged from 9 to 19 $/MMBtu over the past decade, which indicates a challenge for deployment of such a GDH system.

deep direct-use↗

Techno-Economic Analysis for a Potential Geothermal District Heating System in Tuttle, Oklahoma: Preprint

Geothermal deep direct use (DDU) has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for a large-scale and variable heat demand. The National Renewable Energy Laboratory (NREL) and University of Oklahoma evaluated the feasibility of a geothermal district heating (GDH) and cooling system in two schools and 250 houses by utilizing existing oil and gas (O&G) wells in Tuttle, Oklahoma. Heating and cooling demand in the two schools and a typical single-family house were modeled using EnergyPlus building energy simulation software. The modeling results indicated that annual heating demand in two schools and 250 houses is approximately 2.61 GWhth, and cooling demand in the two schools is approximately 2.65 GWhth. In this scope, the techno-economic analysis (TEA) was conducted using the GEOPHIRES tool combined with the TOUGH2 reservoir simulator. The reservoir performance, including geothermal heat production capacity, was modeled by the reservoir simulator TOUGH2. Then, levelized cost of heat (LCOH) was calculated using GEOPHIRES version 3.0, which includes new features such as hourly heat load optimization and peak performance evaluation. Geothermal reservoir temperature was estimated as 90.5 degrees C at a total depth of 3.3 km by the regional average temperature gradient of 22.8 degrees C/km and validated by cation geothermometer calculations. Four production scenarios with two different well configurations and two different heat load profiles have been developed for well flow rates ranging between 3.1 kg/s and 9.3 kg/s. The LCOH of the district heating and cooling system was calculated between $95 and $210/MWh ($28/MMBtu to $62/MMBtu) for four different production scenarios. Typical natural gas prices for residential customers in Oklahoma have ranged from 9 to 19 $/MMBtu over the past decade, which indicates a challenge for deployment of such a GDH system.

deep direct-use↗

Seismic Monitoring near Ithaca, New York, Reveals Nonuniform Distribution of Microseismicity in an Intraplate Region

Abstract Cornell University intends to use a deep direct-use geothermal system to heat its Ithaca, New York, campus. In preparation for this project, the Cornell Seismic Network has been monitoring the background seismicity in this intraplate region since 2019. From January 2020 to June 2023, 95 events were detected within 20 km of the proposed geothermal well site, with local magnitudes ranging from −1.02 to 0.56. None of these events appear in regional or national catalogs. Events locate in a narrow geographic band, with one-fourth exhibiting multimodal hypocentral probability peaks both near the surface and at 1–4 km depth. We relocate events with a joint hypocenter and 1D velocity model inversion, in addition to a fully nonlinear method, and then compare observations with synthetic waveforms. Together, these approaches provide strong evidence for >95% of events locating at the surface or within the 3-km-thick sedimentary sequence. We explore how anthropogenic activity and regional topographic stress may contribute to frequent surficial events. This information is critical for characterizing the background microseismicity for comparison during future geothermal operations. Ithaca’s geology of Paleozoic sediments overlying Precambrian crystalline basement is typical of many continental interiors, so these results also provide insight into intraplate microseismicity patterns.

Geochemistry & Geophysics↗

Socio-Techno-Economic Feasibility of Deep Geothermal with EGS for Residential District Heating in the Northeastern United States

In this paper, we present socio-techno-economic simulation results for enhanced geothermal system (EGS) district heating systems in the northeastern United States. We applied the geospatial Distributed Geothermal Market Demand (dGeo) tool coupled with GEOPHIRES to evaluate the feasibility of geothermal deep direct-use, utilizing EGS reservoirs for providing residential heating with district heating systems. The results were combined with JEDI results to assess social impacts. Simulation results assuming doublet EGS reservoirs with target production temperature of 80 degrees C and newly constructed district heating systems indicate a wide range in system levelized cost of heat (LCOH) values ranging from ~$15/MMBtu to over $1,000/MMBtu, with most the attractive regions urban areas with high total thermal demand and high thermal demand density. We estimate about 60 GWth in potential installed capacity with LCOH values under $50/MMBtu and 100 GWth in potential capacity with LCOH values under $100/MMBtu, respectively.

15 GEOTHERMAL ENERGY↗

Hybrid Uses of High-Temperature Reservoir Thermal Energy Storage: Lessons Learned from Previous Projects

One of the critical challenges of the green energy transition is resolving the mismatch between energy generation provided by intermittent renewable energy sources such as solar and wind and the demand for energy. There is a need for large amounts of energy storage over a range of time scales (diurnal to seasonal) to better balance energy supply and demand. Subsurface geologic reservoirs provide the potential for storage of hot water that can be retrieved when needed and used for power generation or direct-use applications, such as district heating. It is important to identify potential issues associated with high-temperature reservoir thermal energy storage (HT-RTES) systems so that they can be mitigated, thus reducing the risks of these systems. This paper reviews past experiences from moderate and high-temperature reservoir thermal energy storage (RTES) projects, along with hot water and steam flood enhanced oil recovery (EOR) operations, to identify technical challenges encountered and evaluate possible ways to address them. Some of the identified technical problems that have impacted system performance include: 1) insufficient site characterization that failed to identify reservoir heterogeneity; 2) scaling resulting from precipitation of minerals having retrograde solubility that form with heating of formation brines; 3) corrosion from low pH or high salinity brines; 4) thermal breakthrough between hot and cold wells due to insufficient spacing. Proper design, characterization, construction, and operational practices can help reduce the risk of technical problems that could lead to reduced performance of these thermal energy storage systems.

energy storage↗

Low-Temperature Geothermal Play Fairway Analysis for the Denver Basin

This project is part of a national initiative to showcase the benefits of incorporating low-temperature geothermal resource assessment into the deployment of geothermal heating, combined heat and power (CHP), and geothermal direct-use (GDU) technologies. The initiative was established to accelerate the country's decarbonization efforts by identifying potential for low-temperature geothermal resource utilization (<150 degrees C, e.g., CHP and GDU) in selected sedimentary basins with numerous population centers. The play fairway analysis (PFA) methodologies in this study were adapted from previous PFA investigations of sedimentary basin geothermal play types (SBGPTs) that evaluated the potential for low-temperature resources (<150 degrees C). Workflows, relevant datasets, a new Python library, and common and composite geological criteria maps are utilized to develop low-temperature geothermal resource favorability maps for the Denver Basin, a sedimentary basin spanning Colorado, Nebraska, and Wyoming. The replication of these methodologies in other SBGPTs can evaluate potential for low-temperature resources. To facilitate future assessment of low-temperature geothermal resources in SBGPTs, this project provides PFA workflows, data, tools, and favorability maps that will ultimately support the utilization of low-temperature geothermal resources in sedimentary basins.

combined heat and power↗

GEOPHIRES files for DDU techno-economic simulations

During 2017-2019, the U.S. Department of Energy funded six geothermal deep direct-use (DDU) projects to investigate feasibility of DDU for heating, cooling and thermal storage in the United States. In a follow-on study conducted at the National Renewable Energy Laboratory (NREL), findings of these six projects were reviewed and analyzed, and additional simulations were conducted using the simulator GEOPHIRES to explore technical performance and cost-competitiveness of DDU. The results of the NREL study were published in the paper "Evaluating the Feasibility of Geothermal Deep Direct-Use in the United States." The GEOPHIRES files developed in that study are included in this submission. The reference for the paper under review is below: Beckers KF, Kolker A, Pauling H, McTigue JD, and Kesseli D (2021) ?Evaluating the Feasibility of Geothermal Deep Direct-Use in the United States?, Submitted to Energy Conversion and Management, Under Review.

15 GEOTHERMAL ENERGY↗

Ground-Truthing: Exploratory Borehole Characterization and Modeling to Verify and Expand Techno-Economic Evaluation of Earth Source Heat at Cornell U

This report documents the successful completion of DOE award DE-EE0009255: Ground- Truthing: Exploratory Borehole Characterization and Modeling to Verify and Expand Techno- Economic Evaluation of Earth Source Heat at Cornell University . Cornell University is evaluating the technical and economic feasibility of using deep direct-use (DDU) geothermal energy, referred to locally as Earth Source Heat (ESH), to serve as a renewable energy source for campus heating. To meet this objective, Cornell drilled an approximately 3-kilometer-deep exploratory borehole: the Cornell University Borehole Observatory (CUBO), or ESH-1. The team conducted an extensive suite of geophysical, hydrologic, thermal, mechanical, and geochemical measurements to evaluate subsurface conditions and geothermal development potential. This report summarizes the well drilling and testing tasks, findings, and conclusions.

15 GEOTHERMAL ENERGY↗

Subsurface Characterization for Evaluating Geothermal Resource Potential from Existing Oil and Gas Wells in Tuttle, Oklahoma: Preprint

Oil and gas (O&G) wells often encounter co-produced hot water, possibly suitable for geothermal direct-use applications. The City of Tuttle is located on the eastern part of the Anadarko sedimentary basin in Oklahoma with high heat-in-place potential and recovery capability at depth. This study aims at demonstrating the potential of geothermal energy production for direct-use applications in two public schools and 250 nearby houses in Tuttle via repurposing existing O&G wells. In this scope, geochemistry, geology, and borehole log data were collected and incorporated into a 3D conceptual subsurface model. A digital elevation model (DEM) was used to represent the study area topography with four O&G wells. In addition, hydrogeochemical characteristics of the geothermal fluid and scaling potential were analyzed using ternary diagrams and chemical ratios to develop mixing models. The subsurface geology model indicated that the study area primarily consists of Permian to Mississippian Sandstone and Limestone formations, implying a porosity ranging between 12% and 22%, and a permeability up to 3.90E-14 m2 in certain reservoir levels. The reservoir temperature is expected to be ranging between 80 degrees C to 95 degrees C around 3 km depth with an average temperature gradient of 22.8 degrees C/km. Chemical geothermometers also estimated the reservoir temperature as 90 degrees C. Findings of the chemical model demonstrated that the geothermal fluid is Sodium-Potassium-Chloride-Sulfate type and possibly mixed with shallow groundwater resulting in higher Ca and Mg concentrations and lower Na/K ratio implying lower calcite scaling. These results comprehensively characterize the potential of geothermal resources in the study area and imply that geothermal energy production by repurposing existing O&G wells is suitable for low-temperature direct-use applications.

GEOTHERMAL ENERGY↗

Subsurface Characterization for Evaluating Geothermal Resource Potential from Existing Oil and Gas Wells in Tuttle, Oklahoma

Oil and gas (O&G) wells often encounter co-produced hot water, possibly suitable for geothermal direct-use applications. The City of Tuttle is located on the eastern part of the Anadarko sedimentary basin in Oklahoma with high heat-in-place potential and recovery capability at depth. This study aims at demonstrating the potential of geothermal energy production for direct-use applications in two public schools and 250 nearby houses in Tuttle via repurposing existing O&G wells. In this scope, geochemistry, geology, and borehole log data were collected and incorporated into a 3D conceptual subsurface model. A digital elevation model (DEM) was used to represent the study area topography with four O&G wells. In addition, hydrogeochemical characteristics of the geothermal fluid and scaling potential were analyzed using ternary diagrams and chemical ratios to develop mixing models. The subsurface geology model indicated that the study area primarily consists of Permian to Mississippian Sandstone and Limestone formations, implying a porosity ranging between 12% and 22%, and a permeability up to 3.90E-14 m2 in certain reservoir levels. The reservoir temperature is expected to be ranging between 80 degrees C to 95 degrees C around 3 km depth with an average temperature gradient of 22.8 degrees C/km. Chemical geothermometers also estimated the reservoir temperature as 90 degrees C. Findings of the chemical model demonstrated that the geothermal fluid is Sodium-Potassium-Chloride-Sulfate type and possibly mixed with shallow groundwater resulting in higher Ca and Mg concentrations and lower Na/K ratio implying lower calcite scaling. These results comprehensively characterize the potential of geothermal resources in the study area and imply that geothermal energy production by repurposing existing O&G wells is suitable for low-temperature direct-use applications.

gas wells↗

Introduction to this special section: Geothermal energy

Geothermal energy is a global renewable resource that has the potential to provide a significant portion of baseload energy in many regions. In the United States, it has the potential to provide 8.5% of the electric generation capacity by the middle of the century. In general, geothermal systems require heat, permeability, and water to be viable for energy generation. However, with current technologies, only heat is strictly necessary in a native system. Engineered geothermal systems (EGS) introduce water into the subsurface at elevated pressures and reduced temperatures and enhance permeability through hydraulic and/or shear fracturing. Additionally, although moderate- to high-temperature resources currently dominate geothermal energy production, low-temperature resources have been utilized for direct-use cases. When well balanced and maintained, geothermal resources can produce significant amounts of heat and achieve long-term sustainability on the order of an estimated tens to hundreds of years.

15 GEOTHERMAL ENERGY↗

Feasibility of Deep Direct-Use Geothermal on the West Virginia University Campus-Morgantown, WV

In 2010, research completed by the Southern Methodist University (SMU) Geothermal Laboratory estimated temperatures at reasonable drilling depths in the state of West Virginia (WV) were in the temperature range desirable for district heating. This higher temperature region extends from north-central WV (Monongalia County) to southeastern WV (Greenbrier County). The Morgantown campus of West Virginia University (WVU) is located within the north-central region, and as part of the 2016 study on Low-temperature Geothermal Play Fairway Analysis for the Appalachian Basin (GPFA-AB), Morgantown is identified as one of the priority locations for further analysis of the potential for deep direct-use (DDU) of geothermal energy. In this project, the feasibility of developing a Geothermal District Heating and Cooling (GDHC) system for the WVU campus in Morgantown, WV, to replace the current coal-fired steam heating and cooling system, is evaluated.

15 GEOTHERMAL ENERGY↗

Geothermal Direct-Use Applications for the District Energy System in Bucharest, Romania

The city of Bucharest, Romania, hosts the second-largest district energy system (DES) in the world. Geothermal resources can be considered as a supplementary heat source to support the demand for domestic hot water and space heating in the winter and shoulder seasons. The National Laboratory of the Rockies (NLR) has conducted a study that considers geothermal energy to serve a fraction of the existing district heating network operated by Electrocentrale Bucure?ti (ELCEN), the utility operating the DES. Lower Cretaceous and Jurassic limestones make up the main geothermal aquifer underlying Bucharest, which hosts temperatures suitable for district heating (up to 90 degrees C to the north of the city). Anomalous geothermal gradients have been observed to the north of the city, where a pumped well has produced 82 degrees C brine at the wellhead to feed the Therme Bucharest Spa. An anomalous gradient has also been reported to the southeast of the city (35 degrees C/km). NLR modeled the building heating loads of a small portion of the DES (a block of nine prototypical buildings) in its Urban Renewable Building and Neighborhood Optimization (URBANopt ) platform. To simulate meeting a baseload benchmark of 20 MWth deliverable to a small portion of the DES, the NLR team used GEOPHIRES to model production scenarios for (1) hydrothermal systems coupled with heat pumps targeting the main geothermal aquifer in the north, (2) enhanced geothermal systems targeting hot dry rock in the southeast, and (3) huff-and-puff systems targeting a gradient of 25 degrees C/km. Finally, NLR conducted a high-level sensitivity study around the techno-economics of these systems. The outcomes of this work indicate that hot dry rock geothermal resources that can deliver at least 90 degrees C hot water to the Geothermal District Energy System (GeoDES) offer a possible solution for supplemental geothermal heat delivered to the existing DES.

15 GEOTHERMAL ENERGY↗

An Integrated Feasibility Study of Reservoir Thermal Energy Storage (RTES) in Portland, OR, USA

In regions with long cold overcast winters and sunny summers, Deep Direct-Use (DDU) can be coupled with Reservoir Thermal Energy Storage (RTES) technology to take advantage of pre-existing subsurface permeability to save summer heat for later use during cold seasons. Many aquifers worldwide are underlain by permeable regions (reservoirs) containing brackish or saline groundwater that has limited beneficial use due to poor water quality. We investigate the utility of these relatively deep, slow flowing reservoirs for RTES by conducting an integrated feasibility study in the Portland Basin, Oregon, USA, developing methods and obtaining results that can be widely applied to RTES systems elsewhere. As a case study, we have conducted an economic and social cost-benefit analysis for the Oregon Health and Science University (OHSU), a teaching hospital that is recognized as critical infrastructure in the Portland Metropolitan Area. Our investigation covers key factors that influence feasibility including 1) the geologic framework, 2) heat and fluid flow modeling, 3) capital and maintenance costs, 4) the regulatory framework, and 5) operational risks. By pairing a model of building seasonal heat demand with an integrated model of RTES resource supply, we determine that the most important factors that influence RTES efficacy in the study area are operational schedule, well spacing, the amount of summer heat stored (in our model, a function of solar array size), and longevity of the system. Generally, heat recovery efficiency increases as the reservoir and surrounding rocks warm, making RTES more economical with time. Selecting a base-case scenario, we estimate a levelized cost of heat (LCOH) to compare with other sources of heating available to OHSU and find that it is comparable to unsubsidized solar and nuclear, but more expensive than natural gas. Additional benefits of RTES include energy resiliency in the event that conventional energy supplies are disrupted (e.g., natural disaster) and a reduction in fossil fuel consumption resulting in a smaller carbon footprint. Key risks include reservoir heterogeneity and a possible reduction in permeability through time due to scaling (mineral precipitation). Lastly, a map of thermal energy storage capacity for the Portland Basin yields a total of 43,400 GWh, suggesting tremendous potential for RTES in the Portland Metropolitan Area.

14 SOLAR ENERGY↗

Deep Direct-Use Feasibility Study Temperature-Depth Estimates for West Virginia University, Morgantown, WV

This dataset contains data spreadsheets and figures that summarize the results of a stochastic analysis of temperatures at depth below the West Virginia University campus in Morgantown, WV. These results are extracted from a study by Smith (2019), whose results are included in a GDR submission that provides rasters and shapefiles for the Appalachian Basin states of New York, Pennsylvania, and West Virginia (GDR submission #1182). Uncertainties considered included geologic properties, thermal properties, and uncertainty from geostatistical interpolation of the surface heat flow. A Monte Carlo analysis of these uncertain properties was used to predict temperatures at depth using a 1-D heat conduction model. For the pixel corresponding to West Virginia University, a .csv file containing the 10,000 temperature-depth profiles estimated from a Monte Carlo analysis is provided. Temperatures are provided for depths from 1-5 km in 0.5 km increments. These data are summarized in a figure containing violin plots that illustrates the probability of obtaining certain temperatures at depth for Morgantown.

15 GEOTHERMAL ENERGY↗

Environmental Life Cycle Assessment Spreadsheet tool for Deep Direct-Use Geothermal at the University of Illinois at Urbana-Champaign Campus

A Life Cycle Assessment (LCA) spreadsheet tool was developed to analyze potential environmental benefits of a deep direct-use (DDU) geothermal energy system (GES) at the University of Illinois at Urbana-Champaign (U of IL) campus. The LCA spreadsheet tool is a unique contribution to the feasibility study that provides further insight into the cradle-to-grave environmental impacts associated with the GES over the operating life time, as well as other DDU GES with similar objectives. The tool allows for a more in-depth analysis of the feasibility of DDU GES with respect to the overall environmental impacts. For the U of IL assessment, a doublet (two-well) system is evaluated, which is connected to aboveground mechanical system to supply heating to six agricultural research facilities. The additional of new equipment are assessed for the technical and economic feasibility. The results from this study will also allow geothermal resources from the entirety of the Illinois Basin (ILB) to be assessed and allow the DDU technology to be extended to additional areas of the ILB and other low-temperature sedimentary basins with similar characteristics.

15 GEOTHERMAL ENERGY↗

Deep Direct-Use Geothermal Feasibility Study for Hawthorne NV

The Hawthorne Nevada, deep direct-use geothermal study is a two-year effort funded by the U.S. Department of Energy to determine the techno-economic feasibility of implementing a large-scale, direct-use facility for the Hawthorne Army Depot (HAD) and the public facilities of the city of Hawthorne and Mineral County. The approach links a production side analysis (PSA) and a demand side analysis (DSA) into a whole-system analysis (WSA) to provide an integrated assessment of the resource and the probability of delivering economically viable direct-use energy to Hawthorne. Hawthorne, Nevada is in the western part of the Basin and Range province and has been the focus of geothermal investigations for over 40 years. Over the last 15 years, several studies completed by the U.S. Navy Geothermal Program Office (GPO) in conjunction with industry professionals quantified the existence of several low temperature geothermal prospects, the most promising of which is called Prospect A. The promise of Prospect A is based on drilling and flow testing that produced ~100 °C water at flow rates of up to 31 l/s (500 gallons per minute). Measured productivity indexes range from 40-85 l/s/MPa, suggesting a warm and productive heat source. Despite the promise of the resource, uncertainties in its spatial extent and long-term sustainability mean that techno-economic analyses must include probabilities of the sustainability of the resource under different operating scenarios. Here, the PSA is conducted by integrating a wide range of disparate data to estimate lognormal P90, P50, and P10 resource capacities. These capacities are used as input to a thermal-hydrologic (T-H) model to estimate thermal drawdown for each capacity estimate for several different DSA scenarios. Using a systems-based approach, the WSA links the dynamic T-H simulations of the PSA/DSA combinations with the techno-economic model GEOPHIRES to account for both the temporal dynamics and uncertainties in the system to produce probabilistic distributions of several performance metrics including the levelized cost of heat (LCOH) and the return on investment (ROI). This report is the final delivery for the project and documents the study's activities and results.

15 GEOTHERMAL ENERGY↗

Multicriteria screening evaluation of geothermal resources on mine lands for direct use heating

Abstract Direct use of geothermal energy is the oldest and most versatile form of utilizing geothermal energy. In the last decade, this utilization has significantly increased, especially with the installation of geothermal (ground-source) heat pumps. Many current and inactive mine land sites across the U.S. could be redeveloped with clean energy technologies such as direct use geothermal, which would revitalize former mining communities, help with reducing greenhouse gas emissions, and accelerate the transition to a clean energy economy. We present a multicriteria screening framework to evaluate various aspects of direct-use geothermal projects on mine lands. The criteria are divided into three categories: (1) technical potential, (2) demand and benefits, and (3) regulatory and permitting. We demonstrate the framework using publicly available data on a national scale (continental U.S.). Then, using an example of abandoned coal mines in Illinois and focusing on resource potential, we illustrate how this evaluation can be applied at the state or more local scales when a region’s characteristics drive spatial variability estimates. The strength of this approach is the ability to combine seemingly disparate parameters and inputs from numerous sources. The framework is very flexible—additional criteria can be easily incorporated and weights modified if input data support them. Vice versa, the framework can also help identify additional data needed for evaluating those criteria. The multicriteria screening evaluation methodology provides a framework for identifying potential candidates for detailed site evaluation and characterization.

15 GEOTHERMAL ENERGY↗