Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed average tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Numerical investigation of initial condition effects on Rayleigh-Taylor instability with acceleration reversals

The influence of initial conditions on miscible incompressible baroclinically driven Rayleigh-Taylor instability undergoing nonuniform acceleration is explored computationally using an implicit large eddy simulation (ILES) technique. We consider here the particular case of evolution during multiple reversals of acceleration direction, where the flow is alternately statically stable or unstable. In the unstable phase, the flow is driven by the baroclinic release of potential energy, whereas in the stable phase, work is done against the density stratification with the energy exchange taking place by wavelike mechanisms. These dynamics are fundamentally different; here, we track the evolution of volume-averaged turbulent statistics that are most sensitive to changes in the distribution of spectral power and bandwidth of the initial conditions as the flow alternates between dynamical regimes due to acceleration reversal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulation of Photovoltaic Power Output for the Salt River Project Integration Study

One year of power output was simulated at one-minute intervals for each of fourteen hypothetical utility-scale photovoltaic power plants and for the aggregate power output from a large number of distribution-connected photovoltaic systems. For utility-scale plants, the simulation first constructs one-year time series of global horizontal irradiance at one-minute intervals at each plant location, and a performance model translates irradiance and weather information to AC output power. Distribution-connected photovoltaic systems comprise a variety of system configurations: residential-scale rooftop systems at various tilts; commercial-scale flat-roof mounted systems; and commercial-scale ground-mounted tracked systems. For distribution-connected PV systems, the simulation estimates the time series of spatially-averaged irradiance for the region containing the systems, and the performance model is employed to estimate power aggregate power from all systems. The simulation results are validated by comparing statistics for the time series of irradiance with statistics for measured irradiance within the region.

14 SOLAR ENERGY↗

Second Cancers After Fractionated Radiotherapy: Stochastic Population Dynamics Effects

When ionizing radiation is used in cancer therapy it can induce second cancers in nearby organs. Mainly due to longer patient survival times, these second cancers have become of increasing concern. Estimating the risk of solid second cancers involves modeling: because of long latency times, available data is usually for older, obsolescent treatment regimens. Moreover, modeling second cancers gives unique insights into human carcinogenesis, since the therapy involves administering well characterized doses of a well studied carcinogen, followed by long-term monitoring. In addition to putative radiation initiation that produces pre-malignant cells, inactivation (i.e. cell killing), and subsequent cell repopulation by proliferation can be important at the doses relevant to second cancer situations. A recent initiation/inactivation/proliferation (IIP) model characterized quantitatively the observed occurrence of second breast and lung cancers, using a deterministic cell population dynamics approach. To analyze ifradiation-initiated pre-malignant clones become extinct before full repopulation can occur, we here give a stochastic version of this I I model. Combining Monte Carlo simulations with standard solutions for time-inhomogeneous birth-death equations, we show that repeated cycles of inactivation and repopulation, as occur during fractionated radiation therapy, can lead to distributions of pre-malignant cells per patient with variance >> mean, even when pre-malignant clones are Poisson-distributed. Thus fewer patients would be affected, but with a higher probability, than a deterministic model, tracking average pre-malignant cell numbers, would predict. Our results are applied to data on breast cancers after radiotherapy for Hodgkin disease. The stochastic IIP analysis, unlike the deterministic one, indicates: a) initiated, pre-malignant cells can have a growth advantage during repopulation, not just during the longer tumor latency period that follows; b) weekend treatment gaps during radiotherapy, apart from decreasing the probability of eradicating the primary cancer, substantially increase the risk of later second cancers.

Sachs, Rainer K.↗

SU-G-JeP1-12: Head-To-Head Performance Characterization of Two Multileaf Collimator Tracking Algorithms for Radiotherapy

Purpose: Multi-leaf collimator (MLC) tracking is being clinically pioneered to continuously compensate for thoracic and abdominal motion during radiotherapy. The purpose of this work is to characterize the performance of two MLC tracking algorithms for cancer radiotherapy, based on a direct optimization and a piecewise leaf fitting approach respectively. Methods: To test the algorithms, both physical and in silico experiments were performed. Previously published high and low modulation VMAT plans for lung and prostate cancer cases were used along with eight patient-measured organ-specific trajectories. For both MLC tracking algorithm, the plans were run with their corresponding patient trajectories. The physical experiments were performed on a Trilogy Varian linac and a programmable phantom (HexaMotion platform). For each MLC tracking algorithm, plan and patient trajectory, the tracking accuracy was quantified as the difference in aperture area between ideal and fitted MLC. To compare algorithms, the average cumulative tracking error area for each experiment was calculated. The two-sample Kolmogorov-Smirnov (KS) test was used to evaluate the cumulative tracking errors between algorithms. Results: Comparison of tracking errors for the physical and in silico experiments showed minor differences between the two algorithms. The KS D-statistics for the physical experiments were below 0.05 denoting no significant differences between the two distributions pattern and the average error area (direct optimization/piecewise leaf-fitting) were comparable (66.64 cm2/65.65 cm2). For the in silico experiments, the KS D-statistics were below 0.05 and the average errors area were also equivalent (49.38 cm2/48.98 cm2). Conclusion: The comparison between the two leaf fittings algorithms demonstrated no significant differences in tracking errors, neither in a clinically realistic environment nor in silico. The similarities in the two independent algorithms give confidence in the use of either algorithm for clinical implementation.

60 APPLIED LIFE SCIENCES↗

Analysis of Prostate Patient Setup and Tracking Data: Potential Intervention Strategies

Purpose: To evaluate the setup, interfraction, and intrafraction organ motion error distributions and simulate intrafraction intervention strategies for prostate radiotherapy. Methods and Materials: A total of 17 patients underwent treatment setup and were monitored using the Calypso system during radiotherapy. On average, the prostate tracking measurements were performed for 8 min/fraction for 28 fractions for each patient. For both patient couch shift data and intrafraction organ motion data, the systematic and random errors were obtained from the patient population. The planning target volume margins were calculated using the van Herk formula. Two intervention strategies were simulated using the tracking data: the deviation threshold and period. The related planning target volume margins, time costs, and prostate position 'fluctuation' were presented. Results: The required treatment margin for the left-right, superoinferior, and anteroposterior axes was 8.4, 10.8, and 14.7 mm for skin mark-only setup and 1.3, 2.3, and 2.8 mm using the on-line setup correction, respectively. Prostate motion significantly correlated among the superoinferior and anteroposterior directions. Of the 17 patients, 14 had prostate motion within 5 mm of the initial setup position for {>=}91.6% of the total tracking time. The treatment margin decreased to 1.1, 1.8, and 2.3 mm with a 3-mm threshold correction and to 0.5, 1.0, and 1.5 mm with an every-2-min correction in the left-right, superoinferior, and anteroposterior directions, respectively. The periodic corrections significantly increase the treatment time and increased the number of instances when the setup correction was made during transient excursions. Conclusions: The residual systematic and random error due to intrafraction prostate motion is small after on-line setup correction. Threshold-based and time-based intervention strategies both reduced the planning target volume margins. The time-based strategies increased the treatment time and the in-fraction position fluctuation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diffusion–convection model of runaway electrons due to large magnetohydrodynamic perturbations in post-thermal quench plasmas

Systematic test particle tracing simulations for runaway electrons (REs) are performed for six post-thermal quench equilibria from DIII-D and ITER, where large scale, kink-like n = 1 (n is the toroidal mode number) magnetohydrodynamic (MHD) instabilities are found. The modeled particle guiding center orbits allow extraction of the effective diffusion–convection coefficients of REs in the presence of large three-dimensional (3D) perturbations up to 10% of the equilibrium toroidal field. With a fixed spatial distribution of the field perturbation, the RE transport coefficients along the plasma radial coordinate track reasonably well with the surface-averaged perturbation level. A substantial variation in the value of the transport coefficients—by three orders of magnitude in most cases, however, occurs with varying launching location of REs along the plasma radius. Large 3D perturbations almost always lead to comparable diffusion and convection processes, meaning that diffusion alone is insufficient to describe the particle motion. At lower (but still high) level of perturbation, the RE convection is found to be dominant over diffusion. A similar observation is made when the perturbation is too strong. In the presence of large perturbation, the dependence of the RE transport on the particle energy is sensitive to the spatial distribution of the perturbation. Based on numerically obtained RE transport coefficients, an analytic fitting model is proposed to quantify the particle diffusion and convection processes due to large MHD events in post-thermal quench plasmas. The model is shown to reasonably well reproduce the direct test particle tracing results for the RE loss fraction and can, thus, be useful for incorporating into other kinetic RE codes in order to simulate the RE beam evolution in the presence of large 3D perturbations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distributed Optimal Power Management for Battery Energy Storage Systems: A Novel Accelerated Tracking ADMM Approach

Optimal power management (OPM) is critical for large-scale battery energy storage systems. Today’s methods often require formidable computational effort due to the design based on centralized numerical optimization. Thus, this paper investigates computationally distributed OPM where the agents based on the cells communicate over a network to cooperatively solve the OPM problem. We propose an accelerated tracking alternating direction method of multipliers (ADMM) algorithm to solve the distributed OPM. The proposed algorithm embeds dynamic average consensus and Nesterov’s acceleration technique in the ADMM algorithm. Not only is the proposed algorithm fully distributed without a need for fusion or aggregating nodes, but it also accelerates convergence. The paper formulates the OPM in a model predictive control framework where it seeks to regulate the charging/discharging power of each battery cell to minimize the total power losses and promote balanced use of the constituent cells while complying with the safety constraints. The paper provides ample simulation results to demonstrate the effectiveness and advantages of the proposed distributed OPM in terms of computation and convergence.

Farakhor, Amir↗

An airfoil-based synthetic actuator disk model for wind turbine aerodynamic and structural analysis

Here, this study introduces an airfoil-based refinement technique to enhance the Actuator Disk Model (ADM) for improved wind turbine aerodynamic load prediction and structural simulation in conjunction with Large Eddy Simulations of the wind flow. While ADM offers higher computational efficiency than the more detailed but resource-intensive Actuator Line Model (ALM), it traditionally lacks the resolution needed to capture the localized blade forces accurately. To address this limitation, we introduce a refinement technique that uses airfoil-specific data and employs interpolation-based grid point refinement, achieving ALM-comparable accuracy while preserving ADM's efficiency. Unlike conventional ADM that provides only rotor-disk averaged forces, our synthetic method tracks transient aerodynamic load variations over multiple blade revolutions, allowing us to calculate the distributions of maximum and minimum loads during typical cycles. Applied to the NREL 5 MW reference turbine, our enhanced ADM accurately predicts key aerodynamic parameters (angle of attack, axial velocity, lift, drag, axial and tangential forces along the blades) as well as structural responses (blade tip deflection, maximum stress, and stress concentration). Our results show that the tip deflection ranges from 2.33m (3.69 % of blade length) to 4.28m (6.79 %), with maximum stress concentration occurring near the blade root. This research demonstrates that a refined synthetic ADM approach can serve as a computationally efficient alternative for both aerodynamic analysis and structural simulation of wind turbine blades subjected to realistic wind fields.

17 WIND ENERGY↗

Electromagnetic Detection and Real-Time DMLC Adaptation to Target Rotation During Radiotherapy

Purpose: Intrafraction rotation of more than 45 Degree-Sign and 25 Degree-Sign has been observed for lung and prostate tumors, respectively. Such rotation is not routinely adapted to during current radiotherapy, which may compromise tumor dose coverage. The aim of the study was to investigate the geometric and dosimetric performance of an electromagnetically guided real-time dynamic multileaf collimator (DMLC) tracking system to adapt to intrafractional tumor rotation. Materials/Methods: Target rotation was provided by changing the treatment couch angle. The target rotation was measured by a research Calypso system integrated with a real-time DMLC tracking system employed on a Varian linac. The geometric beam-target rotational alignment difference was measured using electronic portal images. The dosimetric accuracy was quantified using a two-dimensional ion chamber array. For each beam, the following five delivery modes were tested: 1) nonrotated target (reference); 2) fixed rotated target with tracking; 3) fixed rotated target without tracking; 4) actively rotating target with tracking; and 5) actively rotating target without tracking. Dosimetric performance of the latter four modes was measured and compared to the reference dose distribution using a 3 mm/3% {gamma}-test. Results: Geometrically, the beam-target rotational alignment difference was 0.3 Degree-Sign {+-} 0.6 Degree-Sign for fixed rotation and 0.3 Degree-Sign {+-} 1.3 Degree-Sign for active rotation. Dosimetrically, the average failure rate for the {gamma}-test for a fixed rotated target was 11% with tracking and 36% without tracking. The average failure rate for an actively rotating target was 9% with tracking and 35% without tracking. Conclusions: For the first time, real-time target rotation has been accurately detected and adapted to during radiation delivery via DMLC tracking. The beam-target rotational alignment difference was mostly within 1 Degree-Sign . Dose distributions to fixed and actively rotating targets with DMLC tracking were significantly superior to those without tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Neural Network Parametrization of Volumetric Cloud Fraction Profiles Using Satellite Observations and MERRA-2 Reanalysis Meteorological Data

Clouds play a crucial role in regulating the hydrologic cycle and Earth's radiative energy budget, yet they are often poorly represented in global climate models (GCMs). This study applies deep machine learning techniques to develop a physical parameterization of volumetric cloud fraction (VCF), the fraction of a 3-D grid volume occupied by clouds using satellite lidar-radar measurements. The neural network (NN) captures the complicated relationships between observed VCF profiles and collocated meteorological variables from MERRA-2 reanalysis data. Our results show that the NN model, particularly a sequence-to-sequence long short-term memory (LSTM) network with a sixfactor loss function, effectively learns the underlying cloud physical processes. The NN model outperforms MERRA-2 reanalysis in representing low-level clouds in tropical and subtropical regions and low- and middle-level clouds over midlatitude storm-track regions, and also improves VCF histograms. These improvements are reflected in the vertical distributions of zonally, meridionally, and globally averaged VCFs, geographic distributions of low-, middle-, and high-level clouds, and seasonal variations in monthly-mean VCF. Furthermore, the NN predictions effectively capture the El Niño-Southern Oscillation (ENSO) effects and other interannual variations. The NN parameterization is further evaluated through a sensitivity analysis, in which a single predictor is perturbed at a time. This reveals that relative humidity (RH) is the dominant factor influencing variations in globally averaged VCF at low and middle altitudes, followed by temperature. At higher altitudes, temperature becomes the primary driver of VCF through its effect on RH. Changes in wind components had minimal impact on globally averaged VCF.

Shan Zeng↗

Latent uncertainties of the precalculated track Monte Carlo method

Purpose: While significant progress has been made in speeding up Monte Carlo (MC) dose calculation methods, they remain too time-consuming for the purpose of inverse planning. To achieve clinically usable calculation speeds, a precalculated Monte Carlo (PMC) algorithm for proton and electron transport was developed to run on graphics processing units (GPUs). The algorithm utilizes pregenerated particle track data from conventional MC codes for different materials such as water, bone, and lung to produce dose distributions in voxelized phantoms. While PMC methods have been described in the past, an explicit quantification of the latent uncertainty arising from the limited number of unique tracks in the pregenerated track bank is missing from the paper. With a proper uncertainty analysis, an optimal number of tracks in the pregenerated track bank can be selected for a desired dose calculation uncertainty. Methods: Particle tracks were pregenerated for electrons and protons using EGSnrc and GEANT4 and saved in a database. The PMC algorithm for track selection, rotation, and transport was implemented on the Compute Unified Device Architecture (CUDA) 4.0 programming framework. PMC dose distributions were calculated in a variety of media and compared to benchmark dose distributions simulated from the corresponding general-purpose MC codes in the same conditions. A latent uncertainty metric was defined and analysis was performed by varying the pregenerated track bank size and the number of simulated primary particle histories and comparing dose values to a “ground truth” benchmark dose distribution calculated to 0.04% average uncertainty in voxels with dose greater than 20% of D{sub max}. Efficiency metrics were calculated against benchmark MC codes on a single CPU core with no variance reduction. Results: Dose distributions generated using PMC and benchmark MC codes were compared and found to be within 2% of each other in voxels with dose values greater than 20% of the maximum dose. In proton calculations, a small (≤1 mm) distance-to-agreement error was observed at the Bragg peak. Latent uncertainty was characterized for electrons and found to follow a Poisson distribution with the number of unique tracks per energy. A track bank of 12 energies and 60000 unique tracks per pregenerated energy in water had a size of 2.4 GB and achieved a latent uncertainty of approximately 1% at an optimal efficiency gain over DOSXYZnrc. Larger track banks produced a lower latent uncertainty at the cost of increased memory consumption. Using an NVIDIA GTX 590, efficiency analysis showed a 807 × efficiency increase over DOSXYZnrc for 16 MeV electrons in water and 508 × for 16 MeV electrons in bone. Conclusions: The PMC method can calculate dose distributions for electrons and protons to a statistical uncertainty of 1% with a large efficiency gain over conventional MC codes. Before performing clinical dose calculations, models to calculate dose contributions from uncharged particles must be implemented. Following the successful implementation of these models, the PMC method will be evaluated as a candidate for inverse planning of modulated electron radiation therapy and scanned proton beams.

07 ISOTOPE AND RADIATION SOURCES↗

Magnetic Resonance Imaging–Guided versus Surrogate-Based Motion Tracking in Liver Radiation Therapy: A Prospective Comparative Study

Purpose: This study applied automatic feature detection on cine–magnetic resonance imaging (MRI) liver images in order to provide a prospective comparison between MRI-guided and surrogate-based tracking methods for motion-compensated liver radiation therapy. Methods and Materials: In a population of 30 subjects (5 volunteers plus 25 patients), 2 oblique sagittal slices were acquired across the liver at high temporal resolution. An algorithm based on scale invariant feature transform (SIFT) was used to extract and track multiple features throughout the image sequence. The position of abdominal markers was also measured directly from the image series, and the internal motion of each feature was quantified through multiparametric analysis. Surrogate-based tumor tracking with a state-of-the-art external/internal correlation model was simulated. The geometrical tracking error was measured, and its correlation with external motion parameters was also investigated. Finally, the potential gain in tracking accuracy relying on MRI guidance was quantified as a function of the maximum allowed tracking error. Results: An average of 45 features was extracted for each subject across the whole liver. The multi-parametric motion analysis reported relevant inter- and intrasubject variability, highlighting the value of patient-specific and spatially-distributed measurements. Surrogate-based tracking errors (relative to the motion amplitude) were were in the range 7% to 23% (1.02-3.57mm) and were significantly influenced by external motion parameters. The gain of MRI guidance compared to surrogate-based motion tracking was larger than 30% in 50% of the subjects when considering a 1.5-mm tracking error tolerance. Conclusions: Automatic feature detection applied to cine-MRI allows detailed liver motion description to be obtained. Such information was used to quantify the performance of surrogate-based tracking methods and to provide a prospective comparison with respect to MRI-guided radiation therapy, which could support the definition of patient-specific optimal treatment strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a facility for high-precision irradiation of cells with carbon ions

Purpose: Compared to photons, using particle radiation in radiotherapy reduces the dose and irradiated volume of normal tissues, potentially reducing side effects. The biological effect of dose deposited by particles such as carbon ions, however, differs from that of dose deposited by photons. The inaccuracy in models to estimate the biological effects of particle radiation remains the most important source of uncertainties in particle therapy. Improving this requires high-precision studies on biological effects of particle radiation. Therefore, the authors aimed to develop a facility for reproducible and high-precision carbon-ion irradiation of cells in culture. The combined dose nonuniformity in the lateral and longitudinal direction should not exceed {+-}1.5%. Dose to the cells from particles than other carbon ions should not exceed 5%. Methods: A uniform lateral dose distribution was realized using a single scatter foil and quadrupole magnets. A modulator wheel was used to create a uniform longitudinal dose distribution. The choice of beam energy and the optimal design of these components was determined using GEANT4 and SRIM Monte Carlo simulations. Verification of the uniformity of the dose distribution was performed using a scintillating screen (lateral) and a water phantom (longitudinal). The reproducibility of dose delivery between experiments was assessed by repeated measurements of the spatial dose distribution. Moreover, the reproducibility of dose-response measurements was tested by measuring the survival of irradiated HEK293 cells in three independent experiments. Results: The relative contribution of dose from nuclear reaction fragments to the sample was found to be <5% when using 90 MeV/u carbon ions. This energy still allows accurate dosimetry conforming to the IAEA Report TRS-398, facilitating comparison to dose-effect data obtained with other radiation qualities. A 1.3 mm long spread-out Bragg peak with a diameter of 30 mm was created, allowing the irradiation of cell samples with the specified accuracy. Measurements of the transverse and longitudinal dose distribution showed that the dose variation over the sample volume was {+-}0.8% and {+-}0.7% in the lateral and longitudinal directions, respectively. The track-averaged LET of 132{+-}10 keV/{mu}m and dose-averaged LET of 189{+-}15 keV/{mu}m at the position of the sample were obtained from a GEANT4 simulation, which was validated experimentally. Three separately measured cell-survival curves yielded nearly identical results. Conclusions: With the new facility, high-precision carbon-ion irradiations of biological samples can be performed with highly reproducible results.

60 APPLIED LIFE SCIENCES↗

Fragmentation of {sup 7}Li relativistic nuclei on a proton into the {sup 3}H + {sup 4}He channel

In a track nuclear photoemulsion exposed to a beam of {sup 7}Li nuclei accelerated to a momentum of 3 GeV/c per nucleon at the synchrophasotron of the Joint Institute for Nuclear Research (JINR, Dubna), 13 events in which {sup 7}Li nuclei interacting with protons break up into {sup 3}H and {sup 4}He fragments were detected among 3730 inelastic-interaction events. For this fragmentation channel, the cross section was found to be 8 {+-} 2 mb. The average value of the fragment total transverse momentum was 214 {+-} 5 MeV/c. This value exceeds markedly the average value of the transverse-momentum transfer in the coherent dissociation of {sup 7}Li nuclei on track-emulsion nuclei (166{+-}5MeV/c). The recoil-proton transverse momentum was on average 98% of the total proton momentum. The longitudinal-momentum distribution of protons was characterized by a variance of 16 MeV/c and a mean value of 37 {+-} 2MeV/c.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improvement of main drift chamber Monte-Carlo tuning model at BESIII

Based on real data, a new parameterized model of the main drift chamber response is proposed in this paper. In this model, we tune the ratio of good hits and the residual distribution separately. Finally, by data quality checking, the difference between simulation and data in track reconstruction efficiency reduces from 1% to 0.5% averagely for the pion in J/ψ → π + π - π 0 , and the momentum resolution agreement improves significantly for the proton in J/ψ → pp¯.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the charged-particle multiplicity inside jets from $$\sqrt{s}=8$$ $${\mathrm{TeV}}$$ pp collisions with the ATLAS detector

The number of charged particles inside jets is a widely used discriminant for identifying the quark or gluon nature of the initiating parton and is sensitive to both the perturbative and non-perturbative components of fragmentation. This paper presents a measurement of the average number of charged particles with p T > 500 MeV inside high-momentum jets in dijet events using 20.3 fb -1 of data recorded with the ATLAS detector in pp collisions at √s=8 TeV collisions at the LHC. The jets considered have transverse momenta from 50 GeV up to and beyond 1.5 TeV . The reconstructed charged-particle track multiplicity distribution is unfolded to remove distortions from detector effects and the resulting charged-particle multiplicity is compared to several models. Lastly, quark and gluon jet fractions are used to extract the average charged-particle multiplicity for quark and gluon jets separately.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Estimation of spatially restricted LET using track structure models

The spatial distribution of energy deposition is an important determinant in the formation of biologically significant lesions. It has been widely realized that Linear Energy Transfer (LET) being an average quantity is not sufficient to describe the situation at a submicroscopic scale. To remedy this to some extent 'energy-cut-off' values are sometimes used but since they are related to secondary electron energy and only indirectly to their range they are also not adequate although they may be easily calculated. 'Range-restricted LET' appears to be better but its determination is usually quite involved. Xapsos (1992) suggested a semi-empirical approximation based on a modified Bethe-formula which contains a number of assumption which are difficult to verify. A simpler and easier way is to use existing beam-models which describe energy deposition around an ion's path. They all agree that the energy density (i. e., energy deposited per unit mass) decreases with the inverse square of the distance from the track center. This simple dependence can be used to determine the fraction of total LET which is deposited in a cylinder of a given radius. As an example our own beam model. Energy density depends on distance x (measured in m) from the track center according to the presented formula.

Kiefer, J.↗

Technical aspects of real time positron emission tracking for gated radiotherapy

Purpose: Respiratory motion can lead to treatment errors in the delivery of radiotherapy treatments. Respiratory gating can assist in better conforming the beam delivery to the target volume. We present a study of the technical aspects of a real time positron emission tracking system for potential use in gated radiotherapy. Methods: The tracking system, called PeTrack, uses implanted positron emission markers and position sensitive gamma ray detectors to track breathing motion in real time. PeTrack uses an expectation–maximization algorithm to track the motion of fiducial markers. A normalized least mean squares adaptive filter predicts the location of the markers a short time ahead to account for system response latency. The precision and data collection efficiency of a prototype PeTrack system were measured under conditions simulating gated radiotherapy. The lung insert of a thorax phantom was translated in the inferior–superior direction with regular sinusoidal motion and simulated patient breathing motion (maximum amplitude of motion ±10 mm, period 4 s). The system tracked the motion of a {sup 22}Na fiducial marker (0.34 MBq) embedded in the lung insert every 0.2 s. The position of the was marker was predicted 0.2 s ahead. For sinusoidal motion, the equation used to model the motion was fitted to the data. The precision of the tracking was estimated as the standard deviation of the residuals. Software was also developed to communicate with a Linac and toggle beam delivery. In a separate experiment involving a Linac, 500 monitor units of radiation were delivered to the phantom with a 3 × 3 cm photon beam and with 6 and 10 MV accelerating potential. Radiochromic films were inserted in the phantom to measure spatial dose distribution. In this experiment, the period of motion was set to 60 s to account for beam turn-on latency. The beam was turned off when the marker moved outside of a 5-mm gating window. Results: The precision of the tracking in the IS direction was 0.53 mm for a sinusoidally moving target, with an average count rate ∼250 cps. The average prediction error was 1.1 ± 0.6 mm when the marker moved according to irregular patient breathing motion. Across all beam deliveries during the radiochromic film measurements, the average prediction error was 0.8 ± 0.5 mm. The maximum error was 2.5 mm and the 95th percentile error was 1.5 mm. Clear improvement of the dose distribution was observed between gated and nongated deliveries. The full-width at halfmaximum of the dose profiles of gated deliveries differed by 3 mm or less than the static reference dose distribution. Monitoring of the beam on/off times showed synchronization with the location of the marker within the latency of the system. Conclusions: PeTrack can track the motion of internal fiducial positron emission markers with submillimeter precision. The system can be used to gate the delivery of a Linac beam based on the position of a moving fiducial marker. This highlights the potential of the system for use in respiratory-gated radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗