Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed average tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Latent uncertainties of the precalculated track Monte Carlo method

Purpose: While significant progress has been made in speeding up Monte Carlo (MC) dose calculation methods, they remain too time-consuming for the purpose of inverse planning. To achieve clinically usable calculation speeds, a precalculated Monte Carlo (PMC) algorithm for proton and electron transport was developed to run on graphics processing units (GPUs). The algorithm utilizes pregenerated particle track data from conventional MC codes for different materials such as water, bone, and lung to produce dose distributions in voxelized phantoms. While PMC methods have been described in the past, an explicit quantification of the latent uncertainty arising from the limited number of unique tracks in the pregenerated track bank is missing from the paper. With a proper uncertainty analysis, an optimal number of tracks in the pregenerated track bank can be selected for a desired dose calculation uncertainty. Methods: Particle tracks were pregenerated for electrons and protons using EGSnrc and GEANT4 and saved in a database. The PMC algorithm for track selection, rotation, and transport was implemented on the Compute Unified Device Architecture (CUDA) 4.0 programming framework. PMC dose distributions were calculated in a variety of media and compared to benchmark dose distributions simulated from the corresponding general-purpose MC codes in the same conditions. A latent uncertainty metric was defined and analysis was performed by varying the pregenerated track bank size and the number of simulated primary particle histories and comparing dose values to a “ground truth” benchmark dose distribution calculated to 0.04% average uncertainty in voxels with dose greater than 20% of D{sub max}. Efficiency metrics were calculated against benchmark MC codes on a single CPU core with no variance reduction. Results: Dose distributions generated using PMC and benchmark MC codes were compared and found to be within 2% of each other in voxels with dose values greater than 20% of the maximum dose. In proton calculations, a small (≤1 mm) distance-to-agreement error was observed at the Bragg peak. Latent uncertainty was characterized for electrons and found to follow a Poisson distribution with the number of unique tracks per energy. A track bank of 12 energies and 60000 unique tracks per pregenerated energy in water had a size of 2.4 GB and achieved a latent uncertainty of approximately 1% at an optimal efficiency gain over DOSXYZnrc. Larger track banks produced a lower latent uncertainty at the cost of increased memory consumption. Using an NVIDIA GTX 590, efficiency analysis showed a 807 × efficiency increase over DOSXYZnrc for 16 MeV electrons in water and 508 × for 16 MeV electrons in bone. Conclusions: The PMC method can calculate dose distributions for electrons and protons to a statistical uncertainty of 1% with a large efficiency gain over conventional MC codes. Before performing clinical dose calculations, models to calculate dose contributions from uncharged particles must be implemented. Following the successful implementation of these models, the PMC method will be evaluated as a candidate for inverse planning of modulated electron radiation therapy and scanned proton beams.

07 ISOTOPE AND RADIATION SOURCES↗

Magnetic Resonance Imaging–Guided versus Surrogate-Based Motion Tracking in Liver Radiation Therapy: A Prospective Comparative Study

Purpose: This study applied automatic feature detection on cine–magnetic resonance imaging (MRI) liver images in order to provide a prospective comparison between MRI-guided and surrogate-based tracking methods for motion-compensated liver radiation therapy. Methods and Materials: In a population of 30 subjects (5 volunteers plus 25 patients), 2 oblique sagittal slices were acquired across the liver at high temporal resolution. An algorithm based on scale invariant feature transform (SIFT) was used to extract and track multiple features throughout the image sequence. The position of abdominal markers was also measured directly from the image series, and the internal motion of each feature was quantified through multiparametric analysis. Surrogate-based tumor tracking with a state-of-the-art external/internal correlation model was simulated. The geometrical tracking error was measured, and its correlation with external motion parameters was also investigated. Finally, the potential gain in tracking accuracy relying on MRI guidance was quantified as a function of the maximum allowed tracking error. Results: An average of 45 features was extracted for each subject across the whole liver. The multi-parametric motion analysis reported relevant inter- and intrasubject variability, highlighting the value of patient-specific and spatially-distributed measurements. Surrogate-based tracking errors (relative to the motion amplitude) were were in the range 7% to 23% (1.02-3.57mm) and were significantly influenced by external motion parameters. The gain of MRI guidance compared to surrogate-based motion tracking was larger than 30% in 50% of the subjects when considering a 1.5-mm tracking error tolerance. Conclusions: Automatic feature detection applied to cine-MRI allows detailed liver motion description to be obtained. Such information was used to quantify the performance of surrogate-based tracking methods and to provide a prospective comparison with respect to MRI-guided radiation therapy, which could support the definition of patient-specific optimal treatment strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a facility for high-precision irradiation of cells with carbon ions

Purpose: Compared to photons, using particle radiation in radiotherapy reduces the dose and irradiated volume of normal tissues, potentially reducing side effects. The biological effect of dose deposited by particles such as carbon ions, however, differs from that of dose deposited by photons. The inaccuracy in models to estimate the biological effects of particle radiation remains the most important source of uncertainties in particle therapy. Improving this requires high-precision studies on biological effects of particle radiation. Therefore, the authors aimed to develop a facility for reproducible and high-precision carbon-ion irradiation of cells in culture. The combined dose nonuniformity in the lateral and longitudinal direction should not exceed {+-}1.5%. Dose to the cells from particles than other carbon ions should not exceed 5%. Methods: A uniform lateral dose distribution was realized using a single scatter foil and quadrupole magnets. A modulator wheel was used to create a uniform longitudinal dose distribution. The choice of beam energy and the optimal design of these components was determined using GEANT4 and SRIM Monte Carlo simulations. Verification of the uniformity of the dose distribution was performed using a scintillating screen (lateral) and a water phantom (longitudinal). The reproducibility of dose delivery between experiments was assessed by repeated measurements of the spatial dose distribution. Moreover, the reproducibility of dose-response measurements was tested by measuring the survival of irradiated HEK293 cells in three independent experiments. Results: The relative contribution of dose from nuclear reaction fragments to the sample was found to be <5% when using 90 MeV/u carbon ions. This energy still allows accurate dosimetry conforming to the IAEA Report TRS-398, facilitating comparison to dose-effect data obtained with other radiation qualities. A 1.3 mm long spread-out Bragg peak with a diameter of 30 mm was created, allowing the irradiation of cell samples with the specified accuracy. Measurements of the transverse and longitudinal dose distribution showed that the dose variation over the sample volume was {+-}0.8% and {+-}0.7% in the lateral and longitudinal directions, respectively. The track-averaged LET of 132{+-}10 keV/{mu}m and dose-averaged LET of 189{+-}15 keV/{mu}m at the position of the sample were obtained from a GEANT4 simulation, which was validated experimentally. Three separately measured cell-survival curves yielded nearly identical results. Conclusions: With the new facility, high-precision carbon-ion irradiations of biological samples can be performed with highly reproducible results.

60 APPLIED LIFE SCIENCES↗

Fragmentation of {sup 7}Li relativistic nuclei on a proton into the {sup 3}H + {sup 4}He channel

In a track nuclear photoemulsion exposed to a beam of {sup 7}Li nuclei accelerated to a momentum of 3 GeV/c per nucleon at the synchrophasotron of the Joint Institute for Nuclear Research (JINR, Dubna), 13 events in which {sup 7}Li nuclei interacting with protons break up into {sup 3}H and {sup 4}He fragments were detected among 3730 inelastic-interaction events. For this fragmentation channel, the cross section was found to be 8 {+-} 2 mb. The average value of the fragment total transverse momentum was 214 {+-} 5 MeV/c. This value exceeds markedly the average value of the transverse-momentum transfer in the coherent dissociation of {sup 7}Li nuclei on track-emulsion nuclei (166{+-}5MeV/c). The recoil-proton transverse momentum was on average 98% of the total proton momentum. The longitudinal-momentum distribution of protons was characterized by a variance of 16 MeV/c and a mean value of 37 {+-} 2MeV/c.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improvement of main drift chamber Monte-Carlo tuning model at BESIII

Based on real data, a new parameterized model of the main drift chamber response is proposed in this paper. In this model, we tune the ratio of good hits and the residual distribution separately. Finally, by data quality checking, the difference between simulation and data in track reconstruction efficiency reduces from 1% to 0.5% averagely for the pion in J/ψ → π + π - π 0 , and the momentum resolution agreement improves significantly for the proton in J/ψ → pp¯.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the charged-particle multiplicity inside jets from $$\sqrt{s}=8$$ $${\mathrm{TeV}}$$ pp collisions with the ATLAS detector

The number of charged particles inside jets is a widely used discriminant for identifying the quark or gluon nature of the initiating parton and is sensitive to both the perturbative and non-perturbative components of fragmentation. This paper presents a measurement of the average number of charged particles with p T > 500 MeV inside high-momentum jets in dijet events using 20.3 fb -1 of data recorded with the ATLAS detector in pp collisions at √s=8 TeV collisions at the LHC. The jets considered have transverse momenta from 50 GeV up to and beyond 1.5 TeV . The reconstructed charged-particle track multiplicity distribution is unfolded to remove distortions from detector effects and the resulting charged-particle multiplicity is compared to several models. Lastly, quark and gluon jet fractions are used to extract the average charged-particle multiplicity for quark and gluon jets separately.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Technical aspects of real time positron emission tracking for gated radiotherapy

Purpose: Respiratory motion can lead to treatment errors in the delivery of radiotherapy treatments. Respiratory gating can assist in better conforming the beam delivery to the target volume. We present a study of the technical aspects of a real time positron emission tracking system for potential use in gated radiotherapy. Methods: The tracking system, called PeTrack, uses implanted positron emission markers and position sensitive gamma ray detectors to track breathing motion in real time. PeTrack uses an expectation–maximization algorithm to track the motion of fiducial markers. A normalized least mean squares adaptive filter predicts the location of the markers a short time ahead to account for system response latency. The precision and data collection efficiency of a prototype PeTrack system were measured under conditions simulating gated radiotherapy. The lung insert of a thorax phantom was translated in the inferior–superior direction with regular sinusoidal motion and simulated patient breathing motion (maximum amplitude of motion ±10 mm, period 4 s). The system tracked the motion of a {sup 22}Na fiducial marker (0.34 MBq) embedded in the lung insert every 0.2 s. The position of the was marker was predicted 0.2 s ahead. For sinusoidal motion, the equation used to model the motion was fitted to the data. The precision of the tracking was estimated as the standard deviation of the residuals. Software was also developed to communicate with a Linac and toggle beam delivery. In a separate experiment involving a Linac, 500 monitor units of radiation were delivered to the phantom with a 3 × 3 cm photon beam and with 6 and 10 MV accelerating potential. Radiochromic films were inserted in the phantom to measure spatial dose distribution. In this experiment, the period of motion was set to 60 s to account for beam turn-on latency. The beam was turned off when the marker moved outside of a 5-mm gating window. Results: The precision of the tracking in the IS direction was 0.53 mm for a sinusoidally moving target, with an average count rate ∼250 cps. The average prediction error was 1.1 ± 0.6 mm when the marker moved according to irregular patient breathing motion. Across all beam deliveries during the radiochromic film measurements, the average prediction error was 0.8 ± 0.5 mm. The maximum error was 2.5 mm and the 95th percentile error was 1.5 mm. Clear improvement of the dose distribution was observed between gated and nongated deliveries. The full-width at halfmaximum of the dose profiles of gated deliveries differed by 3 mm or less than the static reference dose distribution. Monitoring of the beam on/off times showed synchronization with the location of the marker within the latency of the system. Conclusions: PeTrack can track the motion of internal fiducial positron emission markers with submillimeter precision. The system can be used to gate the delivery of a Linac beam based on the position of a moving fiducial marker. This highlights the potential of the system for use in respiratory-gated radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-303-11: Implementation and Applications of Rapid, SIFT-Based Cine MR Image Binning and Region Tracking

Purpose: To develop a novel and rapid, SIFT-based algorithm for assessing feature motion on cine MR images acquired during MRI-guided radiotherapy treatments. In particular, we apply SIFT descriptors toward both partitioning cine images into respiratory states and tracking regions across frames. Methods: Among a training set of images acquired during a fraction, we densely assign SIFT descriptors to pixels within the images. We cluster these descriptors across all frames in order to produce a dictionary of trackable features. Associating the best-matching descriptors at every frame among the training images to these features, we construct motion traces for the features. We use these traces to define respiratory bins for sorting images in order to facilitate robust pixel-by-pixel tracking. Instead of applying conventional methods for identifying pixel correspondences across frames we utilize a recently-developed algorithm that derives correspondences via a matching objective for SIFT descriptors. Results: We apply these methods to a collection of lung, abdominal, and breast patients. We evaluate the procedure for respiratory binning using target sites exhibiting high-amplitude motion among 20 lung and abdominal patients. In particular, we investigate whether these methods yield minimal variation between images within a bin by perturbing the resulting image distributions among bins. Moreover, we compare the motion between averaged images across respiratory states to 4DCT data for these patients. We evaluate the algorithm for obtaining pixel correspondences between frames by tracking contours among a set of breast patients. As an initial case, we track easily-identifiable edges of lumpectomy cavities that show minimal motion over treatment. Conclusions: These SIFT-based methods reliably extract motion information from cine MR images acquired during patient treatments. While we performed our analysis retrospectively, the algorithm lends itself to prospective motion assessment. Applications of these methods include motion assessment, identifying treatment windows for gating, and determining optimal margins for treatment.

60 APPLIED LIFE SCIENCES↗

Dynamical modeling of tidal streams

I present a new framework for modeling the dynamics of tidal streams. The framework consists of simple models for the initial action-angle distribution of tidal debris, which can be straightforwardly evolved forward in time. Taking advantage of the essentially one-dimensional nature of tidal streams, the transformation to position-velocity coordinates can be linearized and interpolated near a small number of points along the stream, thus allowing for efficient computations of a stream's properties in observable quantities. I illustrate how to calculate the stream's average location (its 'track') in different coordinate systems, how to quickly estimate the dispersion around its track, and how to draw mock stream data. As a generative model, this framework allows one to compute the full probability distribution function and marginalize over or condition it on certain phase-space dimensions as well as convolve it with observational uncertainties. This will be instrumental in proper data analysis of stream data. In addition to providing a computationally efficient practical tool for modeling the dynamics of tidal streams, the action-angle nature of the framework helps elucidate how the observed width of the stream relates to the velocity dispersion or mass of the progenitor, and how the progenitors of 'orphan' streams could be located. The practical usefulness of the proposed framework crucially depends on the ability to calculate action-angle variables for any orbit in any gravitational potential. A novel method for calculating actions, frequencies, and angles in any static potential using a single orbit integration is described in the Appendix.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental verification of a real-time compensation functionality for dose changes due to target motion in scanned particle therapy

Purpose: Implementation and experimental assessment of a real-time dose compensation system for beam tracking in scanned carbon beam therapy of intrafractionally moving targets. Methods: A real-time dose compensation functionality has been developed and implemented at the experimental branch of the beam tracking system at GSI Helmholtzzentrum fuer Schwerionenforschung (GSI). Treatment plans for different target geometries have been optimized. They have been delivered using scanned carbon ions with beam tracking (BT) and real-time dose compensation combined with beam tracking (RDBT), respectively. Target motion was introduced by a rotating table. Dose distributions were assessed by ionization chamber measurements and dose reconstructions. These distributions have been compared to stationary delivery for BT as well as RDBT. Additionally simulations have been performed to investigate the dependence of delivered dose distributions on varying motion starting phases for BT and RDBT, respectively. Results: Average measured dose differences between static delivery and motion influenced delivery could be reduced from 27-68 mGy when BT was used to 12-37 mGy when RDBT was used. Nominal dose was 1000 mGy. Simulated dose deliveries showed improvements in dose delivery and robustness against varying starting motion phases when RDBT was used. Conclusions: A real-time dose compensation functionality extending the existing beam tracking functionality has been implemented and verified by measurements. Measurements and simulated dose deliveries show that real-time dose compensation can substantially improve delivered dose distributions for large rotational target motion compared to beam tracking alone.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement of jet charge in dijet events from sqrt(s)=8 TeV pp collisions with the ATLAS detector

CERN-LHC. Measurements of the jet charge in dijet events in proton-proton collisions at a centre-of-mass energy of 8 TeV with 20.3 fb^-1 of data collected in 2012. The jet charge is a momentum-weighted sum of charges of tracks associated to the jet. The momentum is regulated by an exponent kappa. Measurements are reported for the average and standard deviation of the jet charge distribution as a function of the magnitude of the jet transverse momentum for kappa = 0.3, 0.5, 0.7 and separately for the more forward and more central jets (in pseudo-rapidity). The event selection is minimal, with only a requirement that the magnitude of the transverse momenta of the two leading jets be above 50 GeV and that these momenta be within 50% of each other.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nanoconfinement and Mass Transport in Silica Mesopores: the Role of Charge at the Single Molecule and Single Pore Levels

Polarization-dependent single molecule tracking was employed to simultaneously probe the translational and orientational diffusion of four perylene diimide (PDI) dyes, having different lengths and charges, within the one-dimensional (1D) nanoscale pores of surfactant-templated mesoporous silica films. The wide-field fluorescence videos acquired reveal that a significant fraction of the molecules follow 1D pathways and exhibit highly polarized fluorescence, consistent with their orientational confinement. Single-frame step size distributions prepared from these data were fit to a new model that accurately describes the distribution for 1D Fickian diffusion in the presence of finite localization precision. Average diffusion coefficients obtained from mean square displacement (D MSD ) data were 20–100% larger for the two uncharged PDIs compared to the charged PDIs, reflecting electrostatic interactions of the latter with oppositely charged sites on the cationic surfactant headgroups and deprotonated silanol sites on the pore walls. Polarization-dependent tracking data show that the longest uncharged PDI was most strongly confined, while the three shorter dyes were less confined. The cationic PDI produced a wobbling angle distribution that was broader than the others, suggesting it explores more of the pore diameter. In conclusion, the results provide new knowledge on the mechanisms by which the dye molecules interact with the pore-filling medium and the pore surfaces, helping to elucidate the factors controlling the rate of mass transport.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-394: The Use of Jaw Tracking in Intensity Modulated and Volumetric Modulated Arc Radiotherapy for Spine Stereotactic Radiosurgery

Purpose: To evaluate the potential advantages of jaw tracking for intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in spine radiosurgery. Methods: VMAT and IMRT plans were retrospectively generated for ten patients. Six plans for each patient were created in the Eclipse treatment planning system for a Varian Truebeam equipped with a Millennium 120 MLC. Plans were created to study IMRT and VMAT plans with and without jaw tracking, as well as IMRT plans of different flattening filter free (FFF) energies. Plans were prescribed to the 90% isodose line to 16 or 18 Gy in one fraction to cover 95% of the target. Planning target volume (PTV) coverage, conformity index (CI), dose to spinal cord, distance to fall off from the 90% to 50% isodose line (DTF), as well as delivery time were evaluated. Ion chamber and film measurements were performed to verify calculated and measured dose distributions. Results: Jaw tracking decreased the spinal cord dose for both IMRT and VMAT plans, but a larger decrease was seen with the IMRT plans (p=0.004 vs p=0.04). The average D10% for the spinal cord was least for the 6MV FFF IMRT plan with jaw tracking and was greatest for the 10MV FFF plan without jaw tracking. Treatment times between IMRT and VMAT plans with or without jaw tracking were not significantly different. Measured plans showed greater than 98.5% agreement for planar dose gamma analysis (3%/2 mm) and less than 2.5% for point dose analysis compared to calculated plans. Conclusion: Jaw tracking can be used to help decrease spinal cord dose without any change in treatment delivery or calculation accuracy. Lower dose to the spinal cord was achieved using 6 MV beams compared to 10 MV beams, though 10 MV may be justified in some cases to decrease skin dose.

60 APPLIED LIFE SCIENCES↗

TH-A-19A-07: The Effect of Particle Tracking Step Size Limit On Monte Carlo- Computed LET Spectrum of Therapeutic Proton Beams

Purpose: To investigate the effect of charged particle tracking step size limit in the determination of the LET spectrum of therapeutic proton beams using Monte Carlo simulations. Methods: The LET spectra at different depths in a water phantom from a 79.7 MeV spot-scanning proton beam were calculated using Geant4. Five different tracking step limits 0.5 mm, 0.1 mm, 0.05 mm, 0.01 mm and 1 μm were adopted. The field size was set to 10×10 cm{sup 2} on the isocenter plane. A 40×40×6 cm{sup 3} water phantom was modelled as the irradiation target. The voxel size was set to 1×1×0.5 mm{sup 3} to obtain high resolution results. The LET spectra were scored ranging from 0.01 keV/μm to 10{sup 4}keV/μm in the logarithm scale. In addition, the proton energy spectra at different depths were also scored. Results: The LET spectra calculated using different step size limits were compared at four depths along the Bragg curve. At any depths, the spread of the LET spectra increases with the decrease of step size limit. In the dose buildup region (z = 1.9 cm) and in the region proximal to the Bragg peak (z = 3.95 cm), the frequency mean LET does not vary with decreasing step size limit. At Bragg peak (z = 4.75 cm) and in the distal edge (z = 4.85 cm), frequency mean LET decreases with decreasing step size limit. The energy spectrum at any specified depths does not vary with the step size limit. Conclusion: The calculated LET has a spectral distribution rather than a single value at any depths along the Bragg curve and the spread of the computed spectrum depends on the tracking step limit. Incorporating the LET spectrum distribution into the robust IMPT optimization plan may provide more accurate biological dose distribution than using the dose- or fluence-averaged LET. NIH Program Project Grant P01CA021239.

07 ISOTOPE AND RADIATION SOURCES↗

Tracking Elevated Pollution Layers with a Newly Developed Hyperspectral Sun/Sky Spectrometer (4STAR): Results from the TCAP 2012 and 2013 Campaigns

Total columnar amounts of water vapor, nitrogen dioxide (NO2) and ozone (O3) are derived from a newly developed, hyperspectral airborne sun-sky spectrometer (4STAR) for the first time during the two intensive phases of the Two Column Aerosol Project (TCAP) in summer 2012 and winter 2013 aboard the DOE G-1 aircraft. We compare results with coincident measurements. We find 0.045 g/cm2 (4.2%) negative bias and 0.28 g/cm2 (26.3%) root-mean-square (RMS) difference in water vapor layer comparison with in-situ hygrometer, and an overall RMS difference of 1.28 g/m3 (38%) water vapor amount in profile by profile comparisons, with differences distributed evenly around zero in most cases. The RMS differences for O3 values average to 3%, with a 1% negative bias for 4STAR compared with the spaceborne Ozone Measuring Instrument (OMI) along the aircraft flight-track for 14 flights during both TCAP phases. Ground-based comparisons with the Pandora spectrometer system at the Goddard Space Flight Center (GSFC), Greenbelt, Maryland showed excellent agreement between the instruments for both O3 and NO2, further emphasizing 4STAR’s new capabilities. During the summer phase, we have succeeded in identifying variations in elevated pollution layers corresponding to urban pollution outflow and transported biomass burning. This was done using clustering analysis of the retrieved products (e.g. Ångstrom exponent, NO2 and columnar water vapor), and was confirmed by aerosol type identification by HSRL2 aboard the NASA B-200 aircraft. These newly demonstrated 4STAR capabilities are expected to be instrumental in improving our understanding of atmospheric composition variability and aerosol-trace-gas interactions; they open new horizons and opportunities in airborne sunphotometry.

4STAR↗

Experimental evaluations of the accuracy of 3D and 4D planning in robotic tracking stereotactic body radiotherapy for lung cancers

Purpose: Due to the complexity of 4D target tracking radiotherapy, the accuracy of this treatment strategy should be experimentally validated against established standard 3D technique. This work compared the accuracy of 3D and 4D dose calculations in respiration tracking stereotactic body radiotherapy (SBRT). Methods: Using the 4D planning module of the CyberKnife treatment planning system, treatment plans for a moving target and a static off-target cord structure were created on different four-dimensional computed tomography (4D-CT) datasets of a thorax phantom moving in different ranges. The 4D planning system used B-splines deformable image registrations (DIR) to accumulate dose distributions calculated on different breathing geometries, each corresponding to a static 3D-CT image of the 4D-CT dataset, onto a reference image to compose a 4D dose distribution. For each motion, 4D optimization was performed to generate a 4D treatment plan of the moving target. For comparison with standard 3D planning, each 4D plan was copied to the reference end-exhale images and a standard 3D dose calculation was followed. Treatment plans of the off-target structure were first obtained by standard 3D optimization on the end-exhale images. Subsequently, they were applied to recalculate the 4D dose distributions using DIRs. All dose distributions that were initially obtained using the ray-tracing algorithm with equivalent path-length heterogeneity correction (3D{sub EPL} and 4D{sub EPL}) were recalculated by a Monte Carlo algorithm (3D{sub MC} and 4D{sub MC}) to further investigate the effects of dose calculation algorithms. The calculated 3D{sub EPL}, 3D{sub MC}, 4D{sub EPL}, and 4D{sub MC} dose distributions were compared to measurements by Gafchromic EBT2 films in the axial and coronal planes of the moving target object, and the coronal plane for the static off-target object based on the {gamma} metric at 5%/3mm criteria ({gamma}{sub 5%/3mm}). Treatment plans were considered acceptable if the percentage of pixels passing {gamma}{sub 5%/3mm} (P{sub {gamma}<1}) {>=} 90%. Results: The averaged P{sub {gamma}<1} values of the 3D{sub EPL}, 3D{sub MC}, 4D{sub EPL}, and 4D{sub MC} dose calculation methods for the moving target plans are 95%, 95%, 94%, and 95% for reproducible motion, and 95%, 96%, 94%, and 93% for nonreproducible motion during actual treatment delivery. The overall measured target dose distributions are in better agreement with the 3D{sub MC} dose distributions than the 4D{sub MC} dose distributions. Conversely, measured dose distributions agree much better with the 4D{sub EPL/MC} than the 3D{sub EPL/MC} dose distributions in the static off-target structure, resulting in higher P{sub {gamma}<1} values with 4D{sub EPL/MC} (91%) vs 3D{sub EPL} (24%) and 3D{sub MC} (25%). Systematic changes of target motion reduced the averaged P{sub {gamma}<1} to 47% and 53% for 4D{sub EPL} and 4D{sub MC} dose calculations, and 22% for 3D{sub EPL/MC} dose calculations in the off-target films. Conclusions: In robotic tracking SBRT, 4D treatment planning was found to yield better prediction of the dose distributions in the off-target structure, but not necessarily in the moving target, compared to standard 3D treatment planning, for reproducible and nonreproducible target motion. It is important to ensure on a patient-by-patient basis that the cumulative uncertainty associated with the 4D-CT artifacts, deformable image registration, and motion variability is significantly smaller than the cumulative uncertainty occurred in standard 3D planning in order to make 4D planning a justified option.

60 APPLIED LIFE SCIENCES↗

Sci-Thur PM - Colourful Interactions: Highlights 06: Patient-specific calibration of cone-beam computed tomographic (CBCT) image sets for on-line dose tracking and plan assessment

Purpose: To develop a radiotherapy dose tracking and plan evaluation technique using cone-beam computed tomography (CBCT) images. Methods: We developed a patient-specific method of calibrating CBCT image sets for dose calculation. The planning CT was first registered with the CBCT using deformable image registration (DIR). A scatter plot was generated between the CT numbers of the planning CT and CBCT for each slice. The CBCT calibration curve was obtained by least-square fitting of the data, and applied to each CBCT slice. The calibrated CBCT was then merged with original planning CT to extend the small field of view of CBCT. Finally, the treatment plan was copied to the merged CT for dose tracking and plan evaluation. The proposed patient-specific calibration method was also compared to two methods proposed in literature. To evaluate the accuracy of each technique, 15 head-and-neck patients requiring plan adaptation were arbitrarily selected from our institution. The original plan was calculated on each method’s data set, including a second planning CT acquired within 48 hours of the CBCT (serving as gold standard). Clinically relevant dose metrics and 3D gamma analysis of dose distributions were compared between the different techniques. Results: Compared to the gold standard of using planning CTs, the patient-specific CBCT calibration method was shown to provide promising results with gamma pass rates above 95% and average dose metric agreement within 2.5%. Conclusions: The patient-specific CBCT calibration method could potentially be used for on-line dose tracking and plan evaluation, without requiring a re-planning CT session.

60 APPLIED LIFE SCIENCES↗

Multi-scale structural analysis of swift heavy ion-irradiated ZrO 2 and HfO 2

The radiation-induced monoclinic-to-tetragonal phase transition in ZrO 2 and HfO 2 has been the subject of many investigations, but the transformation pathways and underlying structural mechanisms are still not well understood. In this study, microcrystalline powder samples of ZrO 2 and HfO 2 were irradiated with 946 MeV and 1470 MeV Au ions to a wide fluence range up to 3 × 10 13 ions/cm 2 . To characterize beam-induced structural modifications across all spatial length scales, complementary experimental techniques such as synchrotron X-ray diffraction and spallation neutron total scattering were used. The phase evolution of the tetragonal polymorph with increasing ion fluence is accurately described by a heterogeneous track-overlap model that incorporates both direct- and double-impact processes. These damage accumulation processes are an expression of a core-shell ion track morphology that depends on irradiation conditions and target material. Neutron pair distribution function analysis revealed that ion-beam-induced tetragonal ZrO 2 is merely a configurational average of short-range orthorhombic (Pbcn) domains stabilized by a dense network of domain walls. Furthermore, this knowledge is critical for a better understanding of how crystalline-to-crystalline phase transformations proceed at the atomic scale under extreme conditions.

Monoclinic-to-tetragonal phase transformation↗