Divertor characterization and access to dissipative divertor conditions in negative triangularity discharges in DIII-D

Reduced radial transport, short midplane-to-target parallel connection lengths, and a strong effect of cross-field drifts were responsible for the high densities required for detachment in strong negative triangularity (NT) configurations in DIII-D. Dissipative divertor conditions were achieved in NT discharges at different triangularity, injected power, plasma current, and toroidal field direction. Differences between negative and positive triangularity (PT) discharges are analyzed in this paper to understand the requirements for access to detached divertor conditions: power balance, geometry, radial transport and effect of cross-field particle drifts. Parametric dependencies of access to detachment on plasma current and power flowing into the scrape-off layer remained similar in negative and PT and impurity seeding was observed to reduce the density needed to detach by up to 30% at the expense of core impurity dilution. The impact of triangularity on core-edge integration was tested varying bottom triangularity at fixed top triangularity. The high density needed to detach was not intrinsic to the NT edge as shapes with positive lower triangularity and negative upper triangularity were able to detach at lower upstream densities while maintaining an ELM-free NT edge. Confinement degradation at deeper detachment levels was however observed in all NT shapes, often associated with radiation instabilities.

detachment↗

Validation of EDGDE2D-EIRENE predicted 2D distributions of electron temperature and density against divertor Thomson scattering measurements in the low-field side divertor leg in DIII-D

Comparisons of profiles of the electron temperature (T e ), density (n e ) and pressure (p e ) measured with Divertor Thomson Scattering in DIII-D low-confinement mode discharges to predictions from the edge fluid code EDGE2D-EIRENE show that the models implemented in EDGE2D-EIRENE predict the measurements within their collective uncertainties if the T e at the separatrix (T e,sep ) is 10 eV, or higher. The simulations do not predict, however, the peaked T e and ne profiles measured adjacent to the target plate when T e,sep , is below 10 eV, i.e., for the plasma downstream from the region of ionization of deuterium atoms. Inclusion of cross-field drifts and a five-fold reduction of radial transport cannot reconcile the discrepancy between the measurements and predictions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutral leakage, power dissipation and pedestal fueling in open vs closed divertors

The effect of divertor closure on neutral leakage, power dissipation and pedestal fueling is explored using the SOLPS code for different densities including attached and detached divertor conditions for DIII-D open and closed divertors. Here, a metric for divertor closure in terms of the percentage of neutrals escaping the divertor is presented. At the detachment onset the population of neutrals escaping the divertor is 12% for the closed divertor and 35% for the open divertor. This results in a lower contribution of the convective term to the total heat flux and increased power losses in the closed divertor. The comparison between the two geometries reveals that for the same upstream density, the upstream temperature is 23% higher in the closed divertor. The physical mechanisms for detachment at lower upstream density in the closed divertor are also identified with the reduction of the convective term directly resulting in 40% decrease and the increased power losses contributing with a factor of 2. The baffling also lowers the neutral flux refueling the pedestal resulting in further reduction of the core density for achieving detachment. The results introduced here show that the divertor recycling is the primary fueling mechanism in DIII-D. It is shown that fueling occurring in the region between the X-point and the outer midplane is at least four times lower in the closed divertor due the baffling structure which enhances target neutral trapping and consequently reduced upstream leakage. Due to the openness of the inner leg to the common flux and HFS regions both open and closed divertor experience almost identical fueling at the HFS highlighting the need to also consider the inboard divertor for shape optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of deuterium and carbon radiation transport in MAST-U tokamak advanced divertors

Modest effects of deuterium and carbon radiation opacity in the Super-X and snowflake divertor plasmas are predicted for MAST Upgrade tokamak with core plasma input power 2.5–5 MW and plasma current 1 MA. The radiation transport modeling is based on the SOLPS-EIRENE and UEDGE code divertor plasma predictions. Two radiation transport models are used: one is based on a full radiation transport equation implemented in the radiation transport and collisional-radiative code CRETIN (without feedback on the background plasma), and another is an internal self-consistent UEDGE model with ionization, recombination, and heating rates corrected for Ly α line trapping based on the escape probability model implemented in CRETIN. In MAST-U, the Super-X and snowflake divertor plasmas are predicted to reach detached regimes at lower upstream densities than the standard divertor, and the conclusion still holds with radiation transport effects included. At neutral densities m -3 , modest Ly α deuterium line trapping with optical depths 10–15 is predicted in the Super-X divertor. Divertor plasmas are optically thin to other Lyman and Balmer lines, as well as to strong C III and C IV lines that are responsible for most of divertor radiated power. Insignificant changes (within a few percent) to divertor deuterium ionization and recombination rates are found. Radiation fluxes on outer divertor target are modified within a factor of 2–3 when the radiation transport is accounted for, and a similar variation is found due to the line shape models that define the absorption and emission line profiles in the radiation transport modeling. The predicted Lyman and Balmer spectral intensities are significantly modified due to radiation trapping. A measurement of divertor radiation transport effects is discussed using the Ly β /Ba α line ratio. In the snowflake divertor configuration, divertor plasmas are found to be optically thin to Lyman series lines within a large range of parameter variations that include upstream density, divertor transport coefficients, and magnetic configurations. Finally, modest radiation transport effects are only found in a few cases with strongest divertor transport and magnetic configurations closest to the ideal snowflake configuration, however, the plasma background models that were used are yet to be validated with an experiment.

74 ATOMIC AND MOLECULAR PHYSICS↗

SOLPS-ITER modeling of a dedicated divertor for negative triangularity operation on DIII-D

The design of a new dedicated divertor for negative triangularity (NT) operation on DIII-D with neutral baffles and pumping is informed by SOLPS-ITER transport modeling. This dedicated NT divertor is the latest step in a progression of NT shapes with various divertor characteristics explored on DIII-D, including NT shapes at reduced triangularity and a campaign with stronger shaping that included new armored components on the outboard side. SOLPS simulations played a key role in these divertor designs. Interpretive simulations, using cross-field diffusivities constrained by experimental data in the NT Shelf shape were used to inform the design of the 2023 armor campaign components. A similar procedure used armor campaign data to predict conditions for the dedicated NT divertor. The predictive simulations were used to assess the divertor fluxes, detachment threshold, pumped flux, and neutral leakage. For the dedicated NT divertor, SOLPS simulations and two-point-modeling were used to show the relative impact of magnetic topology (mainly longer connection length) and divertor closure on the divertor conditions relative to the armor campaign. It is predicted that the dedicated NT divertor reaches detachment (measured by target ion flux rollover) at a lower upstream density (≈(1.75−−2.4)×1⁢019m−3) as compared to the armor campaign shape. For the preliminary design geometry, divertor closure reduces the neutral leakage by ≈10%. Parametric optimization indicating further ≈20%–60% improvement in the leakage flux and recycled flux crossing the pump entrance is possible for relatively minor changes to the divertor and baffle layout.

Lore, Jeremy [ORNL] (ORCID:000000029192465X)↗

Performance assessment of long-legged tightly-baffled divertor geometries in the ARC reactor concept

Extremely intense power exhaust channels are projected for tokamak-based fusion power reactors; a means to handle them remains to be demonstrated. Advanced divertor configurations have been proposed as potential solutions. Recent modelling of tightly baffled, long-legged divertor geometries for the divertor test tokamak concept, ADX, has shown that these concepts may access passively stable, fully detached regimes over a broad range of parameters. The question remains as to how such divertors may perform in a reactor setting. To explore this, numerical simulations are performed with UEDGE for the long-legged divertor geometry proposed for the ARC pilot plant conceptual design - a device with projected heat flux power width (λq||) of 0.4 mm and power exhaust of 93 MW - first for a simplified Super-X divertor configuration (SXD) and then for the actual X-point target divertor (XPTD) being proposed. It is found that the SXD, combined with 0.5% fixed-fraction neon impurity concentration, can produce passively stable, detached divertor regimes for power exhausts in the range of 80-108 MW - fully accommodating ARC's power exhaust. The XPTD configuration is found to reduce the strike-point temperature by a factor of ~10 compared to the SXD for small separations (~1.4λq||) between main and divertor X-point magnetic flux surfaces. Even greater potential reductions are identified for reducing separations to ~1λq|| or less. The power handling response is found to be insensitive to the level of cross-field convective or diffusive transport assumed in the divertor leg. By raising the separatrix density by a factor of 1.5, stable fully detached divertor solutions are obtained that fully accommodate the ARC exhaust power without impurity seeding. To our knowledge, this is the first time an impurity-free divertor power handling scenario has been obtained in edge modelling for a tokamak fusion power reactor with λq|| of 0.4 mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stable heat and particle flux detachment with efficient particle exhaust in the island divertor of Wendelstein 7-X

The island divertor concept is an innovative and promising idea to handle heat and particle exhaust in stellarators. At the Wendelstein 7-X (W7-X) stellarator, this divertor concept plays a central role in the device mission to demonstrate reactor relevant plasma confinement for steady-state time scales of up to 30 minutes in the high-performance campaign (OP2) starting in 2022. During the recently concluded first campaign with the inertially cooled island divertor, a large step in the experimental qualification of this divertor concept has been made. In discharges heated with electron cylotron resonance heating of 5-6 MW, central densities in the range of 0.7-1.2 × 10 20 m -3 have been reached in combination with full divertor heat flux detachment. Also, significant neutral gas pressures and neutral compression ratios were shown for the first time in combination with reduced divertor particle flux. The divertor heat loads drop by an order of magnitude from >5 MW m -2 to below 0.5 MW m-2 with increasing density, and substantial compression of neutrals reaching neutral pressure in the sub-divertor volume of >6.0 × 10 -4 mbar was seen. These elevated neutral pressure levels can be obtained and maintained with an up to 80% reduction of the particle fluxes onto the divertor target tiles. This discharge scenario was held stably detached for up to 28 seconds, which is equivalent to several hundred energy confinement times τ E and longer than the time scales for current relaxation. No impurity accumulation was seen at constant Z eff ≈ 1.5 and the stored energy stayed constant at levels of W dia >600 kJ. The level of neutral pressure and compression reached in this scenario extrapolates well to the steady-state particle exhaust requirements for high-performance steady-state operation in OP2, in which the fully actively cooled high-heat-flux divertor will be available. Finally, an overview of this recently discovered divertor regime is given and the status of the physics understanding based on modeling of these regimes with the EMC3-EIRENE code is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent progress in the design of the K-DEMO divertor

The preliminary conceptual design of the Korean fusion demonstration reactor (K-DEMO) with a major radius of 6.8 m and the fusion power of 2200 MW has been studied since 2012. The overall configuration of the K-DEMO divetor system based on the ITER-like water-cooled tungsten technology is a double-null type symmetric divertor subdivided into 32 toroidal modules for the vertical maintenance. A detached divertor scenario with impurity seeding was considered as the primary approach for the power exhaust to reduce the peak heat flux lower than the engineering limit of 10 MW/m 2 . The power exhaust performance at the scrap off layer was estimated by using UEDGE-2D code, a two-dimensional fluid transport code for collisional edge plasma and neutral species like N, Ne, and Ar. Particle and heat flux on inboard and outboard divertor targets were calculated for the detached cased depending on parameters such as the impurity seeding rate, pumping rate, and the pedestal density. On the other hand, a magnetic solution like X-divertor, snowflake divertor, and super X-divertor to expand the plasma wet area was considered for K-DEMO since the detached divertor increasing a radiation fraction by impurity seeding might be able to be unstable. However, the extremely high current of poloidal coils was required more than the engineering limit, 20 MA, to form magnetic field lines for the alternative divertors. Based on the physical calculation of the edge plasma, engineering analyses were carried out to find out the thermal and structural reliability. The thermo-hydraulic analysis confirmed thermal stability, whether all comprising materials are operating within their allowable temperature windows when the case of the peak heat flux is set to 10 MW/m 2 on the outboard divertor target. The response surface optimization method derived two optimal design candidates employing two kinds of heat sink materials, respectively: the reduced activation ferritic martensitic (RAFM) steel and CuCrZr alloy. Additionally, the drawbacks and merits of the two materials were definite. The optimal design with applying RAFM steel was vulnerable to withstand thermal and mechanical loads since low thermal conductivity caused too thin thickness of the heat sink. On the other hand, the CuCrZr alloy has critical drawbacks in terms of activation and radioactive waste despite its high thermal conductivity. Meanwhile, preliminary electromagnetic (EM) analysis was carried out to estimate the EM loads caused by the abnormal behaviors of plasma since EM loads are one of the most critical external loads for designing a DEMO divertor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New insights on divertor parallel flows,E × B drifts, and fluctuations from in situ, two-dimensional probe measurement in the Tokamak à Configuration Variable

Abstract In situ , two-dimensional (2D) Langmuir probe measurements across a large part of the TCV outer divertor are reported in L-mode discharges with and without divertor baffles. This provides detailed insights into time averaged profiles, particle fluxes, and fluctuation behavior in different divertor regimes. The presence of the baffles is shown to substantially increase the divertor neutral pressure for a given upstream density and to facilitate the access to detachment, an effect that increases with plasma current. The detailed, 2D probe measurements allow for a divertor particle balance, including ion flux contributions from parallel flows and E × B drifts. The poloidal flux contribution from the latter is often comparable or even larger than the former, and the divertor parallel flow direction reverses in some conditions, pointing away from the target. In most conditions, the integrated particle flux at the outer target can be predominantly ascribed to ionization along the outer divertor leg, consistent with a closed-box approximation of the divertor. The exception is a strongly detached divertor, achieved here only with baffles, where the total poloidal ion flux even decreases towards the outer target, indicative of significant plasma recombination. The most striking observation from relative density fluctuation measurements along the outer divertor leg is the transition from poloidally uniform fluctuation levels in attached conditions to fluctuations strongly peaking near the X-point when approaching detachment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

E × B flow driven electron temperature bifurcation in a closed slot divertor with ion B × ∇ B away from the X-point in the DIII-D tokamak

An electron temperature bifurcation is observed in the small angle slot divertor, which has been developed to enhance neutral cooling across the divertor target by coupling a closed slot structure with appropriate target shaping. Experiments in the DIII-D tokamak and associated SOLPS-ITER modeling with full drifts find a strong interplay between drifts and divertor geometry on divertor dissipation. The coupling of divertor geometry and drift flows can strongly affect the path towards divertor detachment onset as the plasma density is raised. With the strike point on the inner slanted surface and ion B × ∇B away from the magnetic X-point, bifurcative transitions were observed with sharp decrease of T e towards detachment onset both experimentally and computationally. This differs from the situation for the open divertor where the T e cliff was only observed for ion B × ∇B towards the X-point. SOLPS-ITER modeling with full drifts demonstrates that the magnitude of the E × B drift flow is comparable with the main plasma flow. The reversal of both the poloidal and radial E × B flows near the strike point leads to rapid density accumulation right near the separatrix, which results in bifurcative step transition of divertor conditions with cold plasma across the entire divertor target plate. Furthermore, these results indicate that the interplay between geometry and drifts should be fully taken into account in future fusion reactor divertor designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of fully detached divertor integrated with improved core confinement for tokamak fusion plasmas

Integration of divertor detachment with a high-performance (β N ~ 3, β p > 2, H 98 ~ 1.5) core plasma has been demonstrated in DIII-D high-β p (poloidal beta) plasmas associated with a sustained core internal transport barrier (ITB) and an H-mode edge transport barrier (ETB). Such good core-edge integration has been achieved for both neon and nitrogen seeding, for both favorable and unfavorable B-field directions, independently from the impurity puffing locations, though these variations play important roles on divertor characteristics. Compared to the standard H-mode plasmas, the high-β p plasma exhibits a much wider window of detachment compatible with high confinement core. Fully detached divertor plasmas with low plasma temperature (Te < 5 eV), low particle flux, and low heat flux across the entire divertor target plate were obtained by using nitrogen seeding. This detached high-β p plasma is compatible with a newly developed detachment control system which can help optimize the nitrogen gas flow rate. Several features, i.e., the high edge safety factor in the high-β p scenario, impurity injection, closed divertor and reduced heating power requirement due to the high confinement, facilitate the achievement of full divertor detachment at lower density. Instead of degrading global performance, the divertor detachment facilitates the access to an even stronger ITB at large radius with a relatively weak ETB through self-organized synergy between ITB and ETB, leading to sustained high confinement. The strengthening of the large-radius ITB compensates for the ETB degradation associated with divertor detachment. In addition, a weak ETB naturally has smaller edge localized modes (ELMs). In particular, with neon injection, a long-period no-ELM H-mode phase has been achieved simultaneously with high-performance core and partially detached divertor plasmas. Furthermore, these results demonstrate the possibility of integrating excellent core plasma performance with an effective divertor solution, an essential step toward steady-state operation of reactor-grade plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of divertor behavior and plasma confinement between argon and neon seeding in EAST

The exhaust of excessively high heat and particle fluxes on the divertor target is crucial for EAST long-pulse operation. In the recent EAST experiments, stable partial energy detachment around the upper outer strike point with H 98,y2 ~ 1 was achieved with either Ne or Ar seeding from the upper outer divetor target in the upper single null configuration with ITER-like tungsten divertor. With either Ar or Ne seeding, the electron temperature around the upper outer strike point (T et,UOSP ) was maintained at around 5 eV, the peak temperature of divertor target surface around the upper outer strike point (T div,UO ) decreased significantly, and material sputtering was well suppressed. Here, it was observed that there was less Ar seeding needed for partial energy detachment onset than Ne seeding, which shows that Ar is more efficient in the cooling of T et on the upper outer divertor than Ne. However, there was no detachment on the upper inner divertor with T et around strike point (T et,UISP ) remaining >10 eV with either Ar or Ne seeding from the upper outer divertor. Accompanied with the disappearance of double peak phenomenon of ion flux density on the upper inner divertor target (j s,UI ), the peak T div,UI around the strike point increased to around 300 °C. Although the heat flux on the upper inner divertor target (q t,UI ) is still in the acceptable level, either Ar or Ne seeding only from the upper outer divertor target is not enough to protect the upper inner divertor target from sputtering under current EAST conditions. On the other hand, Ar seeding always causes confinement degradation in the partial energy detachment state. It was observed that there is a slight confinement improvement (~10%) with Ne seeding, which may be due to density peaking, dilution effects and stabilization of the ion temperature gradient mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tungsten–carbon surface evolution and erosion modeling for a small angle slot divertor in DIII-D

Abstract We modeled tungsten–carbon mixed surface evolution, sputtering erosion, and transport for the tungsten coated region of a small angle slot (SAS) divertor design for the DIII-D tokamak. This divertor concept aims to achieve a closed slot dissipative plasma to minimize heat load and surface erosion, and to study high- Z material performance. Our advanced simulations use coupled ITMC-DYN material mixing/response and 3D full kinetic REDEP/WBC erosion/redeposition code packages, with divertor plasma solution from the SOLPS-ITER package with 4 MW power input. The SAS design geometry and resulting in-slot plasma parameters cause significant differences in predicted sputter/transport from a conventional divertor. For 2% C/D incident plasma ratio, an equilibrium mixed C/W surface is attained at ∼30 s of discharge, from wall sputtered carbon transported to the 10 cm long tungsten divertor region. Tungsten remains exposed to the plasma, but the evolved surface composition varies with different C/D ratios. Tungsten is primarily sputtered from the mixed surface by impinging carbon ions in the +1 to +4 charge states, with some self-sputtering. Redeposition of sputtered tungsten to the divertor is significant, ∼80% along the higher plasma temperature attached plasma SAS entrance region, but this is less than the typically near-unity values for a conventional divertor. Plasma-incident carbon is highly backscattered (∼50%) from the mixed surface, with little redeposition (<10%); this helps maintain tungsten in the surface sputter zone. Carbon is mainly sputtered from the mixed surface by D + ions, also with low redeposition (∼10%–30%). Finally, the modeling shows non-zero but low sputtered tungsten current from the divertor to the core plasma direction. These results appear favorable for effective testing of a tungsten-containing SAS divertor in DIII-D, and extrapolation of mixed-material evolution/response findings to the analogous low- Z /high- Z , Be/W, ITER plasma facing system.