Search NASA⌕ Search

SEARCH · Search NASA

Results for “document filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

SEED: Semantic Energy Exploration and Discovery

The Bioenergy Knowledge Discovery Framework (KDF) hosts a vast repository of specialized data, yet traditional keyword-based search methods often struggle to provide direct answers, requiring significant domain expertise and manual effort to filter through raw documents. To overcome these barriers, this software introduces a semantic search engine that enables both specialists and non-specialists to query the KDF using natural language. By shifting from rigid keyword matching to intent-based retrieval, the tool automatically identifies and ranks the most relevant sources within the database. The system functions by processing natural language queries to extract the most pertinent information, delivering an AI-generated plain-language summary alongside exact supporting quotes from retrieved documents. This integrated approach provides users with immediate, evidence-based answers while eliminating the need for exhaustive manual review. By surfacing direct insights and contextual evidence, the software enhances the usability of existing KDF resources and democratizes access to complex bioenergy data. Ultimately, this semantic search solution accelerates the discovery process and supports faster, more informed decision-making across the bioenergy sector.

Pan, Meiyu (Melrose) [Oak Ridge National Laborator↗

Measuring aerosol collection efficiency for the Bladewerx “New Speclon TM 5” and the older “Speclon TM 5” filter

Bladewerx TM LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon TM PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon TM filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. The LANL Aerosol Engineering Facility received air filter material from Bladewerx, referred to as “New Speclon 5” in this document, in order to distinguish from filter material that was previously received (referred to as “Speclon 5” in this document). In this document, the aerosol collection efficiency and airflow resistance (pressure drop) were measured for the New Speclon 5 filter material.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assembly Operations Welding Filter(s) in Drum Calculation

This calculation documents the estimation of temperature and pressure rise inside a 55-gal TRU waste drum with a HEPA filter containing Titanium and Tantalum fume dust based on operational history.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assembly Operations Welding Filter(s) in Drum Calculation

This calculation documents the estimation of temperature and pressure rise inside a 55-gal TRU waste drum with a HEPA filter containing Titanium and Tantalum fume dust based on operational history. Actual Titanium values are believed to be less than 10g on any given filter. Actual Tantalum values are believed to be less than 1g on any given filter

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Response functions for Logarithnically Spaced Interference Filters Manufactured for Dark Energy Missions

This data package pertains to test filters produced for the SNAP project. Filter #7 was produced in accordance with the SNAP Test Filter Spec r6.t, including several exceptions taken by JDSU and documented in the JDSU sales order. A set of three Filter #7 parts have been produced for the project, as well as two witnesses for cold environment testing. SNAP Test Filter Spec r6.t requests data to accompany the filters; that is the purpose of this document.

47 OTHER INSTRUMENTATION↗

VirJenDB: a FAIR (meta)data and bioinformatics platform for all viruses

High-throughput sequencing has generated an unprecedented volume of data. However, researcher-submitted data in repositories requires extensive curation and quality control for reuse. These tasks are hindered by the multiplicity of repositories, the sheer volume of the data, and the complexity of virus (meta)data curation. To address these challenges, VirJenDB offers a user-friendly platform to facilitate versioned, community-driven curation, and ontology development. Virus sequences were ingested from 16 sources, including ~200 fields of metadata or standards, covering taxonomy, sample, and host information. Up to 85 metadata fields have undergone at least one round of curation, and are linked to 15.4 million virus sequences, with 88 % from those infecting eukaryotes and the remaining infecting prokaryotes. Subsets were created, including a novel collection of 0.91 million viral operational taxonomic unit (vOTU) sequences across all viruses, while keeping the original sequences from each vOTU to facilitate downstream analyses, e.g. sequence variation. The VirJenDB web portal (https://www.virjendb.org) provides HTTPS and Application Programming Interface (API) access to the sequence datasets and metadata, offering a search engine, filtering, download, visualizations, and documentation. VirJenDB aims to connect the phage and eukaryotic virus research communities by supporting webtool integration, meta-analyses, and metadata schema extensions.

Saghaei, Shahram↗

FY2022 Filter Test for TRU Waste Drum Prototype Unit

Continuing last year’s (fiscal year 2021) work, a prototype instrument and an NPI-6 Integrated Work Document (IWD) were developed to assess the functionality of filters on transuranic waste containers (commonly called 55 Gallon ring-top drums) without requiring the removal of the drum lid. The purpose of this work is to determine the air flow and pressure characteristics associated with filter clogging, filter pressure drop at a fixed flow rate, and leakage around the lid seal. The FY22 objectives included: (A) Development of prototype device, (B) Drafting an IWD document, (C) Defining a filter clogging parameter, (D) Assessing filter damage due to over-pressure events, and (E) A path forward to obtain approval of the system safety filters in compliance with P101-16 Industrial Ventilation – non HVACR (LANL 2022).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Robust Kriged Kalman Filtering

Although the kriged Kalman filter (KKF) has well-documented merits for prediction of spatial-temporal processes, its performance degrades in the presence of outliers due to anomalous events, or measurement equipment failures. This paper proposes a robust KKF model that explicitly accounts for presence of measurement outliers. Exploiting outlier sparsity, a novel l1-regularized estimator that jointly predicts the spatial-temporal process at unmonitored locations, while identifying measurement outliers is put forth. Numerical tests are conducted on a synthetic Internet protocol (IP) network, and real transformer load data. Test results corroborate the effectiveness of the novel estimator in joint spatial prediction and outlier identification.

97 MATHEMATICS AND COMPUTING↗

Earth-Centered, Earth-Fixed Inertial Navigation System & Error-State Kalman Filter Reference Manual

This is a self-contained reference document that derives the equations necessary to build a combined inertial navigation system and error-state Kalman filter. Coordinate transform, linear time invariant system, inertial sensing, and error-state Kalman filtering theory is built up from first principles. This theory is then leveraged to derive the system equations for two combined inertial navigation system and error-state Kalman filters: (1) a 15-state system modeling white-noise-integrating accelerometer and gyroscope biases, and (2) a 39-state system modeling static and first-order Gauss-Markov accelerometer and gyroscope biases, scale factor errors, and cross-axis sensitivity errors.

42 ENGINEERING↗

LDM-612: Plans and Policies for LSST Alert Distribution

A major product of the nightly processing of LSST images is a world-public stream of alerts from transient, variable, and moving sources. Science users will access these alerts through community brokers or through a simple filtering service provided by LSST. This document provides a guide to the plans and policies for the alert distribution system to aid science users, broker developers, funding agencies, and LSST Project personnel. It describes the components of the alert distribution system and the data rights required to access specific scientific products. It provides guidelines for organizations developing community brokers and describes the planned capabilities of the LSST simple alert filtering service and Science Platform to aid science users in planning for LSST science.

79 ASTRONOMY AND ASTROPHYSICS↗

HEPA Filter Disposal Write-Up 10/19/16

Process knowledge (PK) collection on HEPA filters is handled via the same process as other waste streams at LLNL. The Field technician or Characterization point of contact creates an information gathering document (IGD) in the IGD database, with input provided from the generator, and submits it for electronic approval. This document is essentially a waste generation profile, detailing the physical, chemical as well as radiological characteristics, and hazards, of a waste stream. It will typically contain a general, but sometimes detailed, description of the work processes which generated the waste. It will contain PK as well as radiological and industrial hygiene analytical swipe results, and any other analytical or other supporting knowledge related to characterization. The IGD goes through an electronic approval process to formalize the characterization and to ensure the waste has an appropriate disposal path. The waste generator is responsible for providing initial process knowledge information, and approves the IGD before it routed to chemical and radiological waste characterization professionals. This is the standard characterization process for LLNL-generated HEPA Filters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nuclear Canister Filter Test System UPC Plan

LANL has purchased “Hagan” canisters and “SAVY” canisters from NFT Inc (Golden CO). This document provides instruction for calibrating a LANL-designed FTS Filter Test System. The FTS device measures the amount of oil droplet aerosol captured in filters of nuclear material canisters at Los Alamos National Laboratory (LANL). The FTS device is intended to evaluate canister filters manufactured by NFT. The Los Alamos Standards and Calibration Lab (S&CL) does not support the calibration of aerosol generation or counting instrumentation. For operations inside the LANL TA-55 PF4 facility, the LANL FTS system could be potentially contaminated. LANL has constructed two (2) FTS devices, one in TA-55, the other in TA-3.

42 ENGINEERING↗

Filter Test System for Nuclear Container Filters

The purpose of this procedure is to measure the collection efficiency of the filters that are integrated into the lids of containers for nuclear material at Los Alamos National Laboratory (LANL). As an application of this procedure, a filter test report certificate can be created to document the measurement process. This procedure is intended to describe the TA-55, PF-4 (room 6A) operation of a Filter Test System (FTS) for Hagan and SAVY storage containers.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Regulatory Compliance Strategy For Recovery-Driven Underground Ventilation System Changes - 16355

The Waste Isolation Pilot Plant (WIPP) facility is managed and operated by Nuclear Waste Partnership LLC (NWP) for the U.S Department of Energy (DOE). On February 14, 2014, a radiological event occurred in the WIPP facility underground repository, which resulted in the release of transuranic isotopes contaminating a portion of the underground primarily along the ventilation path from Panel 7, the location of the incident. The release was initially detected by an underground continuous air monitor (CAM) which caused an automatic switch of the ventilation system to filtration mode and ventilation was directed through high-efficiency particulate air (HEPA) filtration banks located in the surface exhaust building. When the HEPA filtration was engaged, the underground normal ventilation was reduced from 425,000 standard cubic feet per minute (scfm) to 60,000 scfm. Since the event, all exhaust air is filtered through HEPA filters at 60,000 scfm to minimize the possibility of exposure to workers, the public and the environment. Ventilation of fresh air to the WIPP underground is a primary limitation to performing underground recovery activities; therefore, recovery-driven ventilation changes are needed. The safe recovery of the WIPP facility and resumption of normal waste emplacement activities require an increase in ventilation capacity to be accomplished in three phases: 1) Interim Ventilation System, 2) Supplemental Ventilation System and 3) Permanent Ventilation System. Each phase adds increased air flow to the underground and allows for underground activities to be performed concurrently. The regulatory strategy for ventilation recovery focuses on ensuring that needed changes to the WIPP facility are protective of human health and the environment. Recovery-driven ventilation changes are implemented using the procedures, processes, and regulations that are required by the two primary regulatory agencies for the WIPP facility: the U.S. Environmental Protection Agency (EPA) and the New Mexico Environment Department (NMED) as well as DOE requirements. Regulatory compliance is being achieved for the three ventilation phases to restore underground ventilation by providing the regulators and stakeholders opportunities for involvement during the design and development processes. A strategy for a tiered NMED permitting process and a plan for developing required EPA documentation are under consideration. The Project's objective is to resume normal waste emplacement activities with safety, protection of the public, the worker and the environment as the highest priorities. Important elements of ensuring that WIPP facility recovery and future waste emplacement activities occur as planned are transparency and communication with the regulatory community. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept

The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

62 RADIOLOGY AND NUCLEAR MEDICINE↗