Search NASA⌕ Search

SEARCH · Search NASA

Results for “dosing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Dose Error Impacts on A Collection of Realistic Dose-Response Curves Based on A NASA Sonic Boom Community Noise Survey

The National Aeronautics and Space Administration (NASA) plans to conduct surveys of community response to quiet supersonic flight to collect dose-response data for international regulators. Previous models of noise dose versus annoyance response ignored uncertainty in the noise dose experienced by survey respondents. This dose error causes attenuation bias and results in inaccurate dose-response relationships. The impacts of dose errors can be explored by introducing error into the dose estimates of a simulated community noise survey. The simulated population annoyance response is determined by specific noise response characteristics, including the onset of annoyance intercept, rate of increasing annoyance, participant intercept variability, and response rates. This paper explores the effects of dose errors on notional populations created by perturbing the noise response characteristics observed in participants in a recent NASA flight test, QSF18. The QSF18-based population parameters were shifted up to ±20% to create the study populations. For the anticipated dose range of the X-59, changes to the onset of annoyance intercept have the greatest impact on erroneous model results. Quantifying point estimate errors illustrates the impact of dose error, with errors up to 14 dB observed for a fixed high annoyance percentage.

dose-response modeling↗

Dose Error Impacts on A Collection of Realistic Dose-Response Curves Based on A NASA Sonic Boom Community Noise Survey

The National Aeronautics and Space Administration (NASA) plans to conduct surveys of community response to quiet supersonic flight to collect dose-response data for international regulators. Previous models of noise dose versus annoyance response ignored uncertainty in the noise dose experienced by survey respondents. This dose error causes attenuation bias and results in inaccurate dose-response relationships. The impacts of dose errors can be explored by introducing error into the dose estimates of a simulated community noise survey. The simulated population annoyance response is determined by specific noise response characteristics, including the onset of annoyance intercept, rate of increasing annoyance, participant intercept variability, and response rates. This paper explores the effects of dose errors on notional populations created by perturbing the noise response characteristics observed in participants in a recent NASA flight test, QSF18. The QSF18-based population parameters were shifted up to ±20% to create the study populations. For the anticipated dose range of the X-59, changes to the onset of annoyance intercept have the greatest impact on erroneous model results. Quantifying point estimate errors illustrates the impact of dose error, with errors up to 14 dB observed for a fixed high annoyance percentage.

dose-response modeling↗

Dose rate, dose-equivalent rate, and quality factor in SLS-1

A tissue-equivalent proportional counter (TEPC) sensitive to the lineal energy range of 0.26-300 keV micrometer-1 was flown on STS-40 (39 degrees x 278 km x 296 km) inside the Spacelab. This instrument was previously flown on STS-31 but was modified to provide a finer resolution at lower lineal energies to better map the South Atlantic Anomaly (SAA) protons. The instrument was turned on 6 June 1991, and operated for 7470 min (124.5 h). The flight duration was characterized by a very large number of X-ray solar flares and enhanced magnetic field fluctuations; however, no significant dose from the solar particles was measured at the location of this instrument. The flight data can be separated into trapped and galactic cosmic radiation parts. The dose rate, dose-equivalent rate and quality factor for trapped radiation were 4.21 +/- 0.03 mrad day-1, 7.72 +/- 0.05 mrem day-1, and 1.83 +/- 0.1, respectively. The dose rate, dose-equivalent rate, and quality factor for galactic cosmic radiation were 5.34 +/- 0.03 mrad day-1, 14.63 +/- 0.06 mrem day-1, and 2.74 +/- 0.1, respectively. The overall quality factor for the flight was 2.38. The dose from the GCR is higher than from SAA protons because of the high inclination and low altitude of this flight. The AP8MAX model of the trapped radiation gives a dose rate of 2.43 mrad day-1 and a quality factor of 1.77. The CREME solar maximum model of galactic cosmic radiation gives a dose rate of 2.54 mrad day-1 and a quality factor of 2.91. Thus the AP8MAX model underestimates the dose by a factor of 1.8 whereas the CREME model leads to an underestimation of the dose by a factor of 2. A comparison of the LET spectra using the AP8MAX model and galactic cosmic radiation transport codes shows only a qualitative agreement.

NASA Discipline Number 00-00↗

A Comparison of As-loaded Dose Calculations to Measured Dose Rates

Demonstrating that the radiation dose fields surrounding spent nuclear fuel (SNF) storage and transportation systems meet the applicable limits set forth in 10 CFR 72 for storage and 10 CFR 71 for transportation is essential for the safe handling of radioactive material. The Used Nuclear Fuel-Storage, Transportation, and Disposal Analysis Resource and Data System (UNF-ST&DARDS) [2] is used to provide realistic estimates of SNF-related safety margins. The UNF-ST&DARDS dose rate analysis approach differs from that used in typical licensing approaches, which use design-basis assemblies with bounding source term characteristics to demonstrate the packaging design complies with the regulations. These bounding licensing approaches can increase the time needed to qualify fuel for loading into dry storage and the time a loaded system must wait prior to transportation. UNF-ST&DARDS dose rate assessments allow quantification of realistic, uncredited safety margins associated with actual fuel loading compared with the regulatory limits. While realistic estimation of the dose field surrounding SNF systems may allow for additional flexibility in operations, it is essential to understand how these predictions compare to measured doses. The U.S. Department of Energy Office of Integrated Waste Management and the Prairie Island Indian Community conducted a transportation dose assessment to estimate the site-specific incident-free radiation doses from shipping SNF by rail from the Prairie Island Nuclear Generating Plant (PINGP) through the Prairie Island Indian Community Reservation and Trust Land [5,6]. For that effort, the dose rates were obtained for 50 TN-40 and TN-40HT systems in storage configurations. This work compares the predicted dose rates from UNF-ST&DARDS as-loaded calculations with dose rates measured from 50 SNF storage systems at PINGP. The remainder of this paper discusses the data obtained for the evaluation, the modeling methods, and the results of the calculations.

spent nuclear fuel (SNF), UNF-ST&DARDS, Validation↗

Dose and dose rate effects of whole-body proton-irradiation on lymphocyte blastogenesis and hematological variables: part II

The goal of part II of this study was to evaluate functional characteristics of leukocytes and circulating blood cell parameters after whole-body proton irradiation at varying doses and at low- and high-dose-rates (LDR and HDR, respectively). C57BL/6 mice (n=51) were irradiated and euthanized at 4 days post-exposure for assay. Significant radiation dose- (but not dose-rate-) dependent decreases were observed in splenocyte responses to T and B cell mitogens when compared to sham-irradiated controls (P<0.001). Spontaneous blastogenesis, also significantly dose-dependent, was increased in both blood and spleen (P<0.001). Red blood cell counts, hemoglobin concentration, and hematocrit were decreased in a dose-dependent manner (P<0.05), whereas thrombocyte numbers were only slightly affected. Comparison of proton- and gamma-irradiated groups (both receiving 3 Gy at HDR) showed a higher level of spontaneous blastogenesis in blood leukocytes and a lower splenocyte response to concanavalin A following proton irradiation (P<0.05). There were no dose rate effects. Collectively, the data demonstrate that the measurements in blood and spleen were largely dependent upon the total dose of proton radiation and that an 80-fold difference in the dose rate was not a significant factor. A difference, however, was found between protons and gamma-rays in the degree of change induced in some of the measurements.

Non-NASA Center↗

Dose and dose rate effects of whole-body proton irradiation on leukocyte populations and lymphoid organs: part I

The goal of part I of this study was to evaluate the effects of whole-body proton irradiation on lymphoid organs and specific leukocyte populations. C57BL/6 mice were exposed to the entry region of the proton Bragg curve to total doses of 0.5 gray (Gy), 1.5 Gy, and 3.0 Gy, each delivered at a low dose rate (LDR) of 1 cGy/min and high dose rate (HDR) of 80 cGy/min. Non-irradiated and 3 Gy HDR gamma-irradiated groups were included as controls. At 4 days post-irradiation, highly significant radiation dose-dependent reductions were observed in the mass of both lymphoid organs and the numbers of leukocytes and T (CD3(+)), T helper (CD3(+)/CD4(+)), T cytotoxic (CD3(+)/CD8(+)), and B (CD19(+)) cells in both blood and spleen. A less pronounced dose effect was noted for natural killer (NK1.1(+) NK) cells in spleen. Monocyte, but not granulocyte, counts in blood were highly dose-dependent. The numbers for each population generally tended to be lower with HDR than with LDR radiation; a significant dose rate effect was found in the percentages of T and B cells, monocytes, and granulocytes and in CD4(+):CD8(+) ratios. These data indicate that mononuclear cell response to the entry region of the proton Bragg curve is highly dependent upon the total dose and that dose rate effects are evident with some cell types. Results from gamma- and proton-irradiated groups (both at 3 Gy HDR) were similar, although proton-irradiation gave consistently lower values in some measurements.

Non-NASA Center↗

Statistical Uncertainty of Inhalation Dose Coefficients in Consequence Management: Propagated Dose Uncertainty in ICRP 66 Human Respiratory Tract Model

Reference inhalation dose models rely on deterministic biokinetics and reference computational phantoms, limiting their applicability to the variability present in population-specific exposures encountered in emergency response scenarios. Here, this study introduces REDCAL, a Python-based computational framework developed to propagate uncertainty in inhalation dose coefficients using the International Commission on Radiological Protection (ICRP) Publication 66 Human Respiratory Tract Model. REDCAL integrates ICRP deposition and clearance models, systemic biokinetics, and governing physics principles, and leverages Sandia National Laboratories’ Dakota toolkit for uncertainty quantification via Latin Hypercube Sampling. REDCAL was validated against DCAL, with biokinetic retention results differing by less than 1% and effective dose coefficients by less than 2% across all tested radionuclides. Stochastic sampling introduced variability in dose coefficients, with geometric standard deviations (GSD) in committed effective dose coefficients (CEDC) ranging from 1.0 to 1.5, based on lognormal distribution fits. Analysis demonstrated that variations in the activity median aerodynamic diameter (AMAD) notably influenced the computed CEDC values. Smaller particles (<1 µm) increased doses by 20–30% due to deeper lung deposition and prolonged retention for alpha emitting radionuclides, such as 241 Am and 239 Pu. Radionuclides with fast clearance, such as 133 I, demonstrated a dose reduction exceeding 50%, as AMAD increased beyond 5 µm due to upper airway deposition and rapid mucociliary clearance. The greatest GSD among the radionuclides reported in this study was for 241 Am. In most cases, the largest GSDs in the CEDC were associated with larger particle sizes, an expected outcome, as ICRP Publication 66 defines GSD in particle size as a function of AMAD, resulting in an extended tail of the lognormal distribution. The findings support improved inhalation dose assessments and enhance consequence management strategies for the U.S. Federal Radiological Monitoring and Assessment Center by quantifying uncertainty in dose coefficients and strengthening decision-making for emergency response scenarios.

Biokinetic Modeling↗

Enhanced Low Dose Rate Sensitivity at Ultra-Low Dose Rates

We have presented results of ultra-low dose rate irradiations (< or = 10 mrad(Si)/s) for a variety of radiation hardened and commercial linear bipolar devices. We observed low dose rate enhancement factors exceeding 1.5 in several parts. The worst case of dose rate enhancement resulted in functional failures, which occurred after 10 and 60 krad(Si), for devices irradiated at 0.5 and 10 mrad(Si)/s, respectively. Devices fabricated with radiation hardened processes and designs also displayed dose rate enhancement at below 10 mrad(Si)/s. Furthermore, the data indicated that these devices have not reached the damage saturation point. Therefore the degradation will likely continue to increase with increasing total dose, and the low dose rate enhancement will further magnify. The cases presented here, in addition to previous examples, illustrate the significance and pervasiveness of low dose rate enhancement at dose rates lower than 10 mrad(Si). These results present further challenges for radiation hardness assurance of bipolar linear circuits, and raise the question of whether the current standard test dose rate is conservative enough to bound degradations due to ELDRS.

Chen, Dakai↗

Chromosomal Aberrations in Normal and AT Cells Exposed to High Dose of Low Dose Rate Irradiation

Ataxia telangiectasia (A-T) is a human autosomally recessive syndrome characterized by cerebellar ataxia, telangiectases, immune dysfunction, and genomic instability, and high rate of cancer incidence. A-T cell lines are abnormally sensitive to agents that induce DNA double strand breaks, including ionizing radiation. The diverse clinical features in individuals affected by A-T and the complex cellular phenotypes are all linked to the functional inactivation of a single gene (AT mutated). It is well known that cells deficient in ATM show increased yields of both simple and complex chromosomal aberrations after high-dose-rate irradiation, but, less is known on how cells respond to low-dose-rate irradiation. It has been shown that AT cells contain a large number of unrejoined breaks after both low-dose-rate irradiation and high-dose-rate irradiation, however sensitivity for chromosomal aberrations at low-dose-rate are less often studied. To study how AT cells respond to low-dose-rate irradiation, we exposed confluent normal and AT fibroblast cells to up to 3 Gy of gamma-irradiation at a dose rate of 0.5 Gy/day and analyzed chromosomal aberrations in G0 using fusion PCC (Premature Chromosomal Condensation) technique. Giemsa staining showed that 1 Gy induces around 0.36 unrejoined fragments per cell in normal cells and around 1.35 fragments in AT cells, whereas 3Gy induces around 0.65 fragments in normal cells and around 3.3 fragments in AT cells. This result indicates that AT cells can rejoin breaks less effectively in G0 phase of the cell cycle? compared to normal cells. We also analyzed chromosomal exchanges in normal and AT cells after exposure to 3 Gy of low-dose-rate rays using a combination of G0 PCC and FISH techniques. Misrejoining was detected in the AT cells only? When cells irradiated with 3 Gy were subcultured and G2 chromosomal aberrations were analyzed using calyculin-A induced PCC technique, the yield of unrejoined breaks decreased in both normal and AT cells and misrejoined breaks increased in both cell lines. The present study suggests that AT cells begin to rejoin breaks when a certain number of breaks are accumulated and an increased number of exchanges were observed in G0 AT cells, which is similar situation after high-dose-rate irradiation.

Kawata, T.↗

The effect of modeling dose uncertainty on low-boom community noise dose-response curves

In logistic dose-response modeling, failing to account for uncertainty in estimated doses can cause an artificial flattening or attenuation of the slope of the summary curve. In Lee et al. [J. Acoust. Soc. Am. 147(4), pp. 2222-2234 (2020)], data from two NASA low-amplitude sonic boom community noise survey tests were modeled using a Bayesian multilevel logistic regression (MLR) statistical model that assumed there was no uncertainty in the noise dose estimates. However, in these community tests, the noise dose uncertainty was estimated by Page et al. [NASA/CR-2014-218180 and NASA/CR-2020-220589/Volume I] using a leave-one-out method. In the current work, a term was added to extend the Bayesian MLR model to account for the estimated noise dose uncertainty quantified in the Page et al. analyses. This uncertainty term was included in two ways, either as classical or as Berkson uncertainty, and yield similar results. When the uncertainty is accounted for in the Bayesian MLR model, the dose-response curves become 5-10% steeper, but the difference in the noise dose that elicits a 5% highly annoyed response is small (less than 1 dB). This result is encouraging for future X-59 community tests whose survey area will be sparsely populated with noise monitors.

X-59↗

Conformal Avoidance of Normal Organs at Risk by Perfusion-Modulated Dose Sculpting in Tumor Single-Dose Radiation Therapy

Although 24 Gy single-dose radiation therapy (SDRT) renders >90% 5-year local relapse-free survival in human solid tumor lesions, SDRT delivery is not feasible in ∼50% of oligometastatic lesions owing to interference by dose/volume constraints of a serial organ at risk (OAR). Conformal OAR avoidance is based on a hypothetical model positing that the recently described SDRT biology specifically permits volumetric subdivision of the SDRT dose, such that high-intensity vascular drivers of SDRT lethality, generated within a major tumor subvolume exposed to a high 24 Gy dose (high-dose planning target volume [PTV{sub HD]}), would equilibrate SDRT signaling intensity throughout the tumor interstitial space, rendering bystander radiosensitization of a minor subvolume (perfusion-modulated dose sculpting PTV [PTV{sub PMDS}]), dose-sculpted to meet a serial OAR dose/volume constraint. An engineered PTV{sub PMDS} may thus yield tumor ablation despite PMDS dose reduction and conformally avoiding OAR exposure to a toxic dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Error Correction Using Simulation Extrapolation for Community Noise Dose-Response Modeling

The objective of this work is to provide a framework to account and correct for dose error in dose-response modeling due to measurement uncertainty. Error in noise measurements, especially in the case of limited monitoring locations in a community, can lead to an attenuation or misestimation of parameters in dose-response models. This error can result in overpredicted annoyance at lower doses and underpredicted annoyance at higher doses. Simulated data in the present work are based on previous NASA community studies and incorporate a notional design for future studies with the X-59 aircraft. Several populations of different annoyance response sensitivities are included. Simulation extrapolation (SIMEX, Cook and Stefanski 1994) is used to correct for the dose error in a simple, fully pooled logistic regression. Results indicate the negative impact of attenuation is greatly diminished for all amounts of dose error considered, regardless of a population’s annoyance sensitivity. Therefore, SIMEX can help produce a more accurate dose-response relationship.

SIMEX↗

Total Effective Dose from Radiologic Emissions from INL Facilities for Calculation of Population Dose for the INL 2024 Annual Site Environmental Report

Total effective radiation dose from airborne releases was calculated using air dispersion modeling performed by the National Oceanic and Atmospheric Administration (NOAA) Idaho Falls Office using their HYSPLIT computer model (Stein et al. 2015; Draxler et al. 2013), and the Dose Multi-Media (DOSEMM) dose assessment model (Rood 2019) . The objective of these calculations was to provide a grid of total effective dose across a model domain that encompasses a 50-mile (80-km) radius from any Idaho National Laboratory (INL) Site source. In addition to INL Site sources, releases from the Radiological and Environmental Sciences Laboratory (RESL) (IF-683) and IF-603 located at the INL Research Center (IRC) within the Idaho Falls city limits were also included. Due to tracking limitations, radionuclides released from IF-611 and IF-603 are modeled as released from IF-603. The dose results will be combined with GIS software to compute a total population dose for the calendar year (CY) 2024 and will be reported in the INL Annual Site Environmental Report (ASER). This report does not cover the population dose calculation and only documents generation of the gridded dose file.

42 - ENGINEERING↗

Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

Long, Edward R., Jr.↗

Depth dependence of absorbed dose, dose equivalent and linear energy transfer spectra of galactic and trapped particles in polyethylene and comparison with calculations of models

A matched set of five tissue-equivalent proportional counters (TEPCs), embedded at the centers of 0 (bare), 3, 5, 8 and 12-inch-diameter polyethylene spheres, were flown on the Shuttle flight STS-81 (inclination 51.65 degrees, altitude approximately 400 km). The data obtained were separated into contributions from trapped protons and galactic cosmic radiation (GCR). From the measured linear energy transfer (LET) spectra, the absorbed dose and dose-equivalent rates were calculated. The results were compared to calculations made with the radiation transport model HZETRN/NUCFRG2, using the GCR free-space spectra, orbit-averaged geomagnetic transmission function and Shuttle shielding distributions. The comparison shows that the model fits the dose rates to a root mean square (rms) error of 5%, and dose-equivalent rates to an rms error of 10%. Fairly good agreement between the LET spectra was found; however, differences are seen at both low and high LET. These differences can be understood as due to the combined effects of chord-length variation and detector response function. These results rule out a number of radiation transport/nuclear fragmentation models. Similar comparisons of trapped-proton dose rates were made between calculations made with the proton transport model BRYNTRN using the AP-8 MIN trapped-proton model and Shuttle shielding distributions. The predictions of absorbed dose and dose-equivalent rates are fairly good. However, the prediction of the LET spectra below approximately 30 keV/microm shows the need to improve the AP-8 model. These results have strong implications for shielding requirements for an interplanetary manned mission.

Flight Experiment↗

Dose Response for Chromosome Aberrations in Human Lymphocytes and Fibroblasts after Exposure to Very Low Doses of High LET Radiation

The relationship between biological effects and low doses of absorbed radiation is still uncertain, especially for high LET radiation exposure. Estimates of risks from low-dose and low-dose-rates are often extrapolated using data from Japanese atomic bomb survivors with either linear or linear quadratic models of fit. In this study, chromosome aberrations were measured in human peripheral blood lymphocytes and normal skin fibroblasts cells after exposure to very low dose (1-20 cGy) of 170 MeV/u Si-28- ions or 600 MeV/u Fe-56-ions. Chromosomes were analyzed using the whole chromosome fluorescence in situ hybridization (FISH) technique during the first cell division after irradiation, and chromosome aberrations were identified as either simple exchanges (translocations and dicentrics) or complex exchanges (involving greater than 2 breaks in 2 or more chromosomes). The curves for doses above 10 cGy were fitted with linear or linear-quadratic functions. For Si-28- ions no dose response was observed in the 2-10 cGy dose range, suggesting a non-target effect in this range.

Hada, M.↗

Impact to Groundwater All-Pathways Dose Estimates for the Remote-Handled Low-Level Waste Disposal Facility Performance Assessment Using Updated Dose Coefficients from DOE-STD-1196-2022

The Performance Assessment (PA) for the Remote-Handled Low-Level Waste (RHLLW) Disposal Facility at Idaho National Laboratory (INL) was completed in 2018 (DOE-ID 2018) using dose coefficients from U.S. Department of Energy (DOE) Standard DOE-STD-1196-2011 (DOE 2011). Internal and external dosimetry was updated in 2021 and a new technical standard was published in 2022 (DOE-STD-1196-2022) (DOE 2022). This technical memorandum provides a comparison of the ingestion dose coefficients between those published in DOE (2011) and those published in DOE (2022). The dose coefficients in DOE (2022) were then used to calculate the all-pathways dose for the groundwater pathway and the results between the doses published in the 2018 PA and those calculated using the updated dose coefficients in DOE (2022) were compared. Several other issues in the 2018 RHLLW Disposal Facility PA were also addressed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chromosome aberrations in human lymphocytes induced by 250 MeV protons: effects of dose, dose rate and shielding

Although the space radiation environment consists predominantly of energetic protons, astronauts inside a spacecraft are chronically exposed to both primary particles as well as secondary particles that are generated when the primary particles penetrate the spacecraft shielding. Secondary neutrons and secondary charged particles can have an LET value that is greater than the primary protons and, therefore, produce a higher relative biological effectiveness (RBE). Using the accelerator facility at Loma Linda University, we exposed human lymphocytes in vitro to 250 MeV protons with doses ranging from 0 to 60 cGy at three different dose rates: a low dose rate of 7.5 cGy/h, an intermediate dose rate of 30 cGy/h and a high dose rate of 70 cGy/min. The effect of 15 g/cm2 aluminum shielding on the induction of chromosome aberrations was investigated for each dose rate. After exposure, lymphocytes were incubated in growth medium containing phytohemagglutinin (PHA) and chromosome spreads were collected using a chemical-induced premature chromosome condensation (PCC) technique. Aberrations were analyzed using the fluorescence in situ hybridization (FISH) technique with three different colored chromosome-painting probes. The frequency of reciprocal and complex-type chromosome exchanges were compared in shielded and unshielded samples. c2002 COSPAR. Published by Elsevier Science Ltd. All rights reserved.

Non-NASA Center↗