Search NASASearch

SEARCH · Search NASA

Results for “drift correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Emergency Control Aircraft System Using Thrust Modulation

A digital longitudinal Aircraft Propulsion Control (APC system of a multiengine aircraft is provided by engine thrust modulation in response to comparing an input flightpath angle signal (gamma)c from a pilot thumbwheel. or an ILS system with a sensed flightpath angle y to produce an error signal (gamma)e that is then integrated (with reasonable limits) to generate a drift correction signal to be added to the error signal (gamma)e after first subtracting a lowpass filtered velocity signal Vel(sub f) for phugoid damping. The output error signal is multiplied by a constant to produce an aircraft thrust control signal ATC of suitable amplitude to drive a throttle servo for all engines. each of which includes its own full-authority digital engine control (FADEC) computer. An alternative APC system omits sensed flightpath angle feedback and instead controls the flightpath angle by feedback of the lowpass filtered velocity signal Vel(sub f) which also inherently provides phugoid damping. The feature of drift compensation is retained.

Burken, John J.

Machine learning pipeline for denoising low signal-to-noise ratio and out-of-distribution transmission electron microscopy datasets

High-resolution transmission electron microscopy (HRTEM) is crucial for observing material’s structural and morphological evolution at Angstrom scales, but the electron beam can alter these processes. Devices such as CMOS-based direct-electron detectors operating in electron-counting mode can be utilized to substantially reduce the electron dosage. However, the resulting images often lead to a low signal-to-noise ratio, which requires frame integration that sacrifices temporal resolution. Several machine learning (ML) models have been recently developed to successfully denoise HRTEM images. Yet, these models are often computationally expensive, and their inference speeds on GPUs are outpaced by the imaging speed of advanced detectors, precluding in situ analysis. Furthermore, the performance of these denoising models on datasets with imaging conditions that deviate from the training datasets has not been evaluated. To mitigate these gaps, we propose a new self-supervised ML denoising pipeline specifically designed for time-series HRTEM images. This pipeline integrates a blind-spot convolution neural network with pre-processing and post-processing steps, including drift correction and low-pass filtering. Results demonstrate that our model outperforms various other ML and non-ML denoising methods in noise reduction and contrast enhancement, leading to improved visual clarity of atomic features. Additionally, the model is drastically faster than U-Net-based ML models and demonstrates excellent out-of-distribution generalization. The model’s computational inference speed is in the order of milliseconds per image, rendering it suitable for application in in-situ HRTEM experiments.

36 MATERIALS SCIENCE

Large area sheet task: Advanced Dendritic Web Growth Development

A melt level control system was implemented to provide stepless silicon feed rates from zero to rates exactly matching the silicon consumed during web growth. Bench tests of the unit were successfully completed and the system mounted in a web furnace for operational verification. Tests of long term temperature drift correction techniques were made; web width monitoring seems most appropriate for feedback purposes. A system to program the initiation of the web growth cycle was successfully tested. A low cost temperature controller was tested which functions as well as units four times as expensive.

Duncan, C. S.

JPL pulsar timing observations. IV - Excess phase noise

Previously published tables of geocentric arrival times for 24 pulsars covering a 12 year span are extended here to 14.5 years. The list of pulsars is extended by nine, most of which were observed for about 4 years. Known positins of these new objects are confirmed, and limits on the proper motions are obtained. Large phase excursions in PSR 0525 + 21 are found. The orbital parameters of the binary pulsar 0820 + 02 are tentatively confirmed. Short-term timing noise in excess of that expected from receiver considerations alone is established. Variations in the timing residuals for the original 24 pulsars are analyzed for correlations with other observable parameters. Little significant correlation with changes in pulse shape or energy or with the drift correction is found on time scales of 500 pulses or longer.

Downs, G. S.

Rubidium atomic frequency standards for GPS Block IIR

The Rubidium Atomic Frequency Standards (RAFS) were provided for the GPS Block IIR NAVSTAR satellites. These satellites will replenish and upgrade the space segment of the Global Positioning System in the mid 1990s. The GPS RAFS Rb clocks are the latest generation of the high-performance rubidium frequency standards. They offer an aging rate in the low pp 10(exp 14)/day range and a drift-corrected 1-day stability in the low pp 10(exp 14) range. The Block IIR version of these devices will have improved performance, higher reliability, smaller size, and greater radiation hardness. The GPS Block IIR atomic clocks have a natural frequency configuration whereby they output a frequency of about 13.4 MHz that is a submultiple of the atomic resonance of Rb (or Cs). The RAFS operates at a low, fixed C-field for increased stability. The GPS Block IIR RAFS design, including the changes and improvements made, and the test results obtained are described.

Riley, William J.

Ozone depletion in the high latitude lower stratosphere - 1979-1990

Archived Stratospheric Aerosol and Gas Experiment (SAGE, SAGE II) and Solar and Backscattered Ultraviolet (SBUV) data are used to examine lower stratospheric O3 variations at 50 deg latitude in both hemispheres. These data indicate that from 1979 to 1985, 73-90 percent of the total O3 changes have occurred below approximately 25 km in altitude. Significant O3 depletions (up to 15 percent) have occurred in the partial column (127-15.8 mbar) in both hemispheres with indications of a recovery after 1985. Two-dimensional model simulations of O3 changes from 1979 to 1990 have been carried out. Comparisons with O3 data are presented. Model results suggest that by 1985, significant declines in global O3 were caused by destruction by odd nitrogen associated with long-term variations in the flux of precipitating relativistic electrons (2.6 percent); solar UV flux changes (1.8 percent); the dilution effect associated with the Antarctic O3 hole (1.2 percent); and atmospheric increases in CH4, N2O, and chlorofluorocarbons (0.4 percent). Analyses of drift-corrected SBUV and Total Ozone Mapping Spectrometer data and model calculations indicate that between 1979 and 1985, reductions of 4.3 to 4.8 percent in total column O3 averaged between 65 deg S and 65 deg N have occurred. Calculations indicate a full global O3 decline of 5.2 percent (peak-to-peak) or 6 percent (annual average) between 1979 and 1985 with a partial recovery between 1985 and 1989.

Callis, Linwood B.

High-Performance X-ray Detection in a New Analytical Electron Microscope

X-ray detection by energy-dispersive spectrometry in the analytical electron microscope (AEM) is often limited by low collected X-ray intensity (P), modest peak-to-background (P/B) ratios, and limitations on total counting time (tau) due to specimen drift and contamination. A new AFM has been designed with maximization of P. P/B, and tau as the primary considerations. Maximization of P has been accomplished by employing a field-emission electron gun, X-ray detectors with high collection angles, high-speed beam blanking to allow only one photon into the detector at a time, and simultaneous collection from two detectors. P/B has been maximized by reducing extraneous background signals generated at the specimen holder, the polepieces and the detector collimator. The maximum practical tau has been increased by reducing specimen contamination and employing electronic drift correction. Performance improvments have been measured using the NIST standard Cr thin film. The 0-3 steradian solid angle of X-ray collection is the highest value available. The beam blanking scheme for X-ray detection provides 3-4 times greater throughput of X-rays at high count rates into a recorded spectrum than normal systems employing pulse-pileup rejection circuits. Simultaneous X-ray collection from two detectors allows the highest X-ray intensity yet recorded to be collected from the NIST Cr thin film. The measured P/B of 6300 is the highest level recorded for an AEM. In addition to collected X-ray intensity (cps/nA) and P/B measured on the standard Cr film, the product of these can be used as a figure-of-merit to evaluate instruments. Estimated minimum mass fraction (MMF) for Cr measured on the standard NIST Cr thin film is also proposed as a figure-of-merit for comparing X-ray detection in AEMs. Determinations here of the MMF of Cr detectable show at least a threefold improvement over previous instruments.

Lyman, C. E.

The Parable of the Boiled Safety Professional

Common and unique issues contribute to system failures. This paper touches on the concept of drift to failure as a cautionary message. Managers and leaders, design team members, fabricators and assemblers, analysis and assurance personnel, and others associated with operating and maintaining systems, need to pay attention to identify the manifestation of individual and collective behaviors that might indicate slips in rigor or focus or decisions that might eat away at safety margins as our system drifts to failure. Corrections to drift made during design and development phases may efficiently prevent or mitigate drift problems occurring in the operational phase.

Shivers, Charles H.

Lower-Hybrid Drift Waves and Their Interaction With Plasmas in A 3D Symmetric Reconnection Simulation With Zero Guide Field

We investigate lower-hybrid drift waves (LHDW) in symmetric magnetic reconnection with zero guide field using three-dimensional particle-in-cell simulations. The long-wavelength mode with develops in the bifurcated electron current layer around the X-line within the width of the electron meandering motion from the mid-plane, where is the ion (electron) gyroradius. The short-wavelength mode with develops in the separatrix region downstream of the electron outflow jet, producing electron vortices in the background flow frame. Electrons follow the E × B drift with corrections from the diamagnetic drift and are heated inside the vortices with diverging electric fields. In the vortices, ions have comparable E × B and inertia drifts, which together mostly cancel the diamagnetic drift. Toward the center of diverging field vortices, ions are decelerated, leading to a decrease in the perpendicular temperature, while the loss of low-energy ions results in an increase in the parallel temperature. Parallel electric fields exist as a combination of the LHDW wave field projected to the magnetic field direction and the penetration of whistler waves that are mainly outside of the LHDW layer. The magnetic flux tube is twisted in the vortices. The twist may potentially lead to slippage reconnection, as indicated by the non-uniform parallel potential variation across field lines, while the periodic variations of the twisting directions are a limiting factor.

Shan Wang

Spectral Response and Effective Area Functions of the Hitomi Imaging Instruments

We describe the tools and the underlying methods and principles for generating the spectral response functions for the four imaging instruments that were flown on the Hitomi x-ray astronomy satellite [Soft X-ray Spectrometer, or SXS; Soft X-ray Imager, or SXI, and two Hard X-ray Imagers, or HXI]. In essence, the spectral response function is a temporally and spatially averaged effective area and line-spread-function. For model-fittingx-ray spectra from an instrument, the spectral response function encapsulates the end-to-end physics of the entire system from telescope to detector, and also includes satellite attitude drift, exposure corrections, and in the case of the HXIs, drift in the telescope/detector alignment system. Accuracy in the construction of the spectral response functions is, therefore, critical to maximize the science return from the data.

Yaqoob, Tahir

Inertial attitude determination for a dual-spin planetary spacecraft

Design and performance evaluations of an onboard inertial attitude determination system for a dual-spin planetary spacecraft are presented. A quaternion integration algorithm and a rate estimator sequentially determine the scan platform's inertial attitude and rate from the drift and misalignment compensated gyro outputs. A least-squares estimator algorithm processes the star transit data from a rotor-mounted star scanner, and provides periodic updates of the scan platform's attitude as a means of correcting the drift of the quaternion integration algorithm. Computer simulated algorithm performance in the presence of nutation and sensor noise are presented.

Wong, E. C.

An approach to the detection of long-term trends in upper stratospheric ozone from space

A central problem in the detection of long-term trends in the upper stratospheric ozone from orbiting remote sensors involves the separation of instrument drifts from true geophysical changes. Periodic flights of a Solar Backscatter Ultraviolet radiometer (SSBUV) on the Space Shuttle will allow the detection of drifts in optically identical sensors (SBUV/2) carried on operational satellites. A detailed simulation of the SSBUV and SBUV/2 datasets defines the accuracy that can be attained by the in-orbit calibration procedure. The repeatability of the SSBUV calibration from one flight to the next is the most critical variable in the analysis. A repeatability near + or - 1.0 percent is essential for detection and correction of drifts in the SBUV/2 radiance measurements. The simulations show that true geophysical trends in backscattered radiance can be inferred to an accuracy of approximately + or - 1.0 percent per decade when SSBUV flies approximately once per year and provides a precise calibration correction to the SBUV/2 dataset over a full decade.

Frederick, John E.

A fundamental study of suction for Laminar Flow Control (LFC)

This report covers the period forming the first year of the project. The aim is to experimentally investigate the effects of suction as a technique for Laminar Flow Control. Experiments are to be performed which require substantial modifications to be made to the experimental facility. Considerable effort has been spent developing new high performance constant temperature hot-wire anemometers for general purpose use in the Fluid Mechanics Laboratory. Twenty instruments have been delivered. An important feature of the facility is that it is totally automated under computer control. Unprecedently large quantities of data can be acquired and the results examined using the visualization tools developed specifically for studying the results of numerical simulations on graphics works stations. The experiment must be run for periods of up to a month at a time since the data is collected on a point-by-point basis. Several techniques were implemented to reduce the experimental run-time by a significant factor. Extra probes have been constructed and modifications have been made to the traverse hardware and to the real-time experimental code to enable multiple probes to be used. This will reduce the experimental run-time by the appropriate factor. Hot-wire calibration drift has been a frustrating problem owing to the large range of ambient temperatures experienced in the laboratory. The solution has been to repeat the calibrations at frequent intervals. However the calibration process has consumed up to 40 percent of the run-time. A new method of correcting the drift is very nearly finalized and when implemented it will also lead to a significant reduction in the experimental run-time.

Watmuff, Jonathan H.

Assessment of Long-term Trends in the Collection 4 Total Ozone Record from the Ozone Monitoring Instrument

Long-term changes in total ozone affect the amount of harmful UV radiation reaching Earth’s surface and reflect progress made towards recovery of stratospheric ozone. Satellite total ozone data are also used to estimate long-term trends in tropospheric ozone, a reactive and potent greenhouse gas, by subtracting the stratospheric column timeseries from that of total ozone. For these scientific applications, the long-term stability should be better than 1%. Left unchecked, instrument calibration drift can produce a trend of this magnitude or greater. NASA has produced nearly twenty years of total ozone data from the Ozone Monitoring Instrument (OMI) using the Total Ozone Mapping Spectrometer (TOMS) algorithm. The drift in the OMI instrument as monitored by ice radiance calibration has been relatively slow, but it has reached a level of ~3% over the mission lifetime. This drift was corrected in the recently released Collection 4 OMI calibrated radiances, updating the Collection 3 calibration released in 2006. We have reprocessed the OMI total ozone record using the Collection 4 calibration and updates to the TOMS algorithm. We summarize these changes and evaluate their impact by comparing to the previous Collection 3 OMI dataset, the Suomi NPP Ozone Mapping and Profiler Suite Nadir Mapper (OMPS-NM) and Solar Backscatter UV (SBUV) Merged Ozone Dataset (MOD) total ozone records and other independent satellite total ozone datasets. Climatological radiance residuals from OMI and OMPS-NM are calculated and compared to investigate differences in spectral calibration that can cause drifts in long-term total ozone trends. We also analyze the tropospheric ozone record produced using the Collection 4 OMI total ozone and stratospheric column ozone from MLS. Collection 3 OMI data processed with the TOMS algorithm show a positive drift relative to other satellite and ground-based data of 1-2 DU per decade. Initial results show that this drift is reduced in Collection 4 OMI, due to the updated OMI calibration. In this work we will quantify the improvements in Collection 4 OMI relative to independent data sources at both the ozone and radiance level

Collection 4 OMI Total Ozone

Resonant scattering at the center of the galaxy cluster PKS 0745-191 with XRISM

We report evidence of the resonant scattering effect at the center of the galaxy cluster PKS 0745-191 with XRISM. We analyzed XRISM/Resolve commissioning-phase observations of the distant cluster PKS 0745-191 ($z = 0.103$) with a $54$ ks exposure. The gain drift was corrected using the onboard modulated X-ray source (MXS), and spectra were extracted from all the pixels that were well illuminated by MXS, the core region (four central pixels, $\sim$100 kpc), and the surrounding region. A single-temperature collisional ionization equilibrium (CIE) model fits the full field-of-view spectrum with $kT \approx 6$ keV and a turbulent velocity of ${\approx}120$ km s$^{-1}$. From the core ($r < 50$ kpc) spectrum, we detected a ${\approx}22\%$ suppression of the Fe xxv He$\alpha$ resonance (w) line relative to the CIE prediction. We performed a Monte Carlo simulation to calculate the resonant scattering (RS) effect using radial profiles from Chandra data. The RS-inferred turbulence agrees with that by Resolve line-broadening, demonstrating that RS provides an independent and consistent constraint on ICM turbulence. These results highlight XRISM/Resolve’s potential for turbulence studies in galaxy clusters.

Astronomy and AstroPhysics

Digital system provides superregulation of nanosecond amplifier-discriminator circuit

Feedback system employing a digital logic comparator to detect and correct amplifier drift provides stable gain characteristics for nanosecond amplifiers used in counting applications. Additional anticoincidence logic enables application of the regulation circuit to the amplifier and discriminator while they are mounted in an operable circuit.

Forges, K. G.

Low-insertion-resistance current monitor

Circuit automatically corrects for drifting offset voltage, providing long-term stability for current-monitoring instruments. Circuit is stable over wide temperature range; therefore, no compensation for temperature variations is necessary. Besides consuming little power, circuit introduces negligible noise on monitored lines and responds linearly to monitored circuit.

Paulkovich, J.

STS-40 orbital acceleration research experiment flight results during a typical sleep period

The Orbital Acceleration Research Experiment (OARE), an electrostatic accelerometer package with complete on-orbit calibration capabilities, was flown for the first time aboard the Space Shuttle on STS-40. This is also the first time an accelerometer package with nano-g sensitivity and a calibration facility has flown aboard the Space Shuttle. The instrument is designed to measure and record the Space Shuttle aerodynamic acceleration environment from the free molecule flow regime through the rarified flow transition into the hypersonic continuum regime. Because of its sensitivity, the OARE instrument defects aerodynamic behavior of the Space Shuttle while in low-earth orbit. A 2-hour orbital time period on day seven of the mission, when the crew was asleep and other spacecraft activities were at a minimum, was examined. During the flight, a 'trimmed-mean' filter was used to produce high quality, low frequency data which was successfully stored aboard the Space Shuttle in the OARE data storage system. Initial review of the data indicated that, although the expected precision was achieved, some equipment problems occurred resulting in uncertain accuracy. An acceleration model which includes aerodynamic, gravity-gradient, and rotational effects was constructed and compared with flight data. Examination of the model with the flight data shows the instrument to be sensitive to all major expected low frequency acceleration phenomena; however, some erratic instrument bias behavior persists in two axes. In these axes, the OARE data can be made to match a comprehensive atmospheric-aerodynamic model by making bias adjustments and slight linear corrections for drift. The other axis does not exhibit these difficulties and gives good agreement with the acceleration model.

Blanchard, R. C.