Measurements of ion-molecule reactions of He plus, H plus, HeH plus with H sub 2 and D sub 2

A drift tube mass spectrometer apparatus has been used to determine the rate coefficient, energy dependence and product ions of the reaction He(+) +H2. The total rate coefficient at 300 K is 1.1 plus or minus 0.1) 10 to minus 13th power cu cm/sec. The reaction proceeds principally by dissociative charge transfer to produce H(+), with the small remainder going by charge transfer to produce H2(+) and by atom rearrangement to produce HeH(+). The rate coefficient increases slowly with increasing ion mean energy, reaching a value of 2.8 x ten to the minus 13th power cu cm sec at 0.18 eV. The corresponding reaction with deuterium, He(+) + D2, exhibits a value (5 plus or minus 1) x 10 to the minus 14th cu cm/sec at 300K. The reaction rates for conversion of H(+) and HeH(+) to H3(+) on collisions with H2 molecules are found to agree well with results of previous investigations.

Johnsen, R.↗

Photodetachment of thermally relaxed CO3/-/

The CO3(-) ion is the most abundant negative ion species in the night-time D region (65-85 km above earth's surface). The absolute photodetachment cross section and the solar detachment rate of ground electronic and vibrational energy state of this ion have been determined by using an electron-detecting drift-tube method. The CO3(-) ion is identified by mass and mobility measurements and its cross section is obtained. The solar photodetachment rate is found to be 0.022. The experiment may be of interest to the modeling of the ionized atmosphere.

Hong, S. P.↗

Improved electron-beam probe for hypersonic flows

Probe uses differentially-pumped drift tube to connect high and low pressure regions thereby allowing higher gas densities to be studied. System uses higher beam voltages (50 kV) and currents (1 mA delivered to gas), and extends boundary layer penetration up to 15.2 cm, and test duration to one hour.

Mcronald, A. D.↗

Microparticle accelerator of unique design

A microparticle accelerator has been devised for micrometeoroid impact and cratering simulation; the device produces high-velocity (0.5-15 km/sec), micrometer-sized projectiles of any cohesive material. In the source, an electrodynamic levitator, single particles are charged by ion bombardment in high vacuum. The vertical accelerator has four drift tubes, each initially at a high negative voltage. After injection of the projectile, each tube is grounded in turn at a time determined by the voltage and charge/mass ratio to give four acceleration stages with a total voltage equivalent to about 1.7 MV.

Vedder, J. F.↗

Association reactions of C/+/ ions with H2 and D2 molecules at 78 and 300 K

The paper deals with an investigation of associated reactions of C(+) ions with H2 and D2 molecules, using drift-tube-mass spectrometer techniques. It is found that at H2 and D2 densities of 1 x 10 to the 16th per cu cm, the reactions proceed by three-body association, the rate coefficients at 300 and 78 K being somewhat higher for D2 than for H2. The measurements place an upper limit on the rate coefficients for radiative association, a process thought to constitute an important step in the formation of molecules in interstellar gas clouds

Johnsen, R.↗

Dissociative charge transfer of H/+/ ions with H2 and D2 molecules from 78 to 330 K

The dissociative charge transfer of He(+) ions with H2 and D2 molecules has been studied using a temperature-variable drift-tube mass-spectrometer apparatus over the temperature range 78 to 330 K. The binary rate coefficients are small at 300 K, approximately 10 to the -13th to 10 to the -14th cu cm/sec, and only slightly larger at 78 K. Termolecular contributions to the binary rate coefficients are found to be small at 330 K but increase substantially with decreasing temperature. Two-body charge transfer with D2 is found to be slower than with H2 by a factor of 10, in good agreement with recent theoretical predictions, although the measured values of the rate coefficients are larger by a factor of about 4 than the predicted values.

Johnsen, R.↗

Reactions of ground-state and metastable O/2+/ ions with He, O2, N2, and CO2 at thermal energies

Evidence is presented that some previous studies of reactions of O(2+) ions with various atoms and molecules referred to ion samples composed in part of ions in metastable (1D and/or 1S) states. This finding resolves the 3 orders of magnitude discrepancy between previous experimental and calculated rate coefficients for the O(2+)(3P) + He charge transfer process. Using a drift tube to distinguish, via arrival time differences, groundstate O(+)(3P) and metastable ions, a rate coefficient of (3.5 plus or minus 1.5) x 10 to the -11th cu cm/sec is obtained for the reaction, in good agreement with that obtained from ab initio theoretical calculations. Previous conclusions concerning reactions of O(2+) with O2 and N2, however, remain valid since the difference in reactivity of ground-state and metastable O(2+) ions appears to be negligible in this case. The rate coefficient for the reaction O(2+) + CO2 has been determined to be (2 plus or minus 0.5) x 10 to the -9th cu cm/sec for ions either in the ground-state or in metastable states.

Johnsen, R.↗

Fuel-rich catalytic combustion: A soot-free technique for in situ hydrogen-like enrichment

An experimental program on the catalytic oxidation of iso-octane demonstrated the feasibility of the two-stage combustion system for reducing particulate emissions. With a fuel-rich (phi = 4.8 to 7.8) catalytic combustion preburner as the first stage the combustion process was soot free at reactor outlet temperatures of 1200 K or less. Although soot was not measured directly, its absence was indicated. Reaction products collected at two positions downstream of the catalyst bed were analyzed on a gas chromatograph. Comparison of these products indicated that pyrolysis of the larger molecules continued along the drift tube and that benzene formation was a gas-phase reaction. The effective hydrogen-carbon ratio calculated from the reaction products increased by 20 to 68 percent over the range of equivalence ratios tested. The catalytic partial oxidation process also yielded a large number of smaller-containing molecules. The fraction of fuel carbon in compounds having two or fewer carbon atoms ranged from 30 percent at 1100 K to 80 percent at 1200 K.

Brabbs, T. A.↗

A possible EAS array above the Soudan 2 detector

Multiple high energy muons, when studied with a large area detector, can be useful in the study of the composition of cosmic rays at energies approx. 10 14 eV. The Soudan II detector, primarily designed to detect nucleon decay, is located approx. 600 m deep underground and has dimensions of 16m x 8m x 5m (height), and is made up of drift tubes. The minimum muon energy needed to penetrate that depth is approximately 500 GeV. A set of simulated cosmic ray showers was set up to calculate the rate of muon associated events, using a trigger array with the number of detectors varying from 37 to 127 (the radius of acceptance varying from 50m to 100m). The number used in the calculations is given. The association rate is seen to be a strong function of the multiplicity of muons in the detector. The difference in the rates of association of proton and nuclei induced showers rises rapidly with multiplicity.

Sivaprasad, K.↗

A ground-based experimental test program to duplicate and study the spacecraft glow phenomenon

The use of a plasma device, the Advanced Concepts Torus-I, for producing atoms and molecules to study spacecraft glow mechanisms is discussed. A biased metal plate, located in the plasma edge, is used to accelerate and neutralize plasma ions, thus generating a neutral beam with a flux approx. 5 x 10 to the 14th power/sq cm/sec at the end of a drift tube. Our initial experiments are to produce a 10 eV molecular and atomic nitrogen beam directed onto material targets. Photon emission in the spectral range 2000 to 9000 A from excited species formed on the target surface will be investigated.

Langer, W. D.↗

Integrated development facility for the calibration of low-energy charged particle flight instrumentation

The design of a low-energy ion facility for development and calibration of thermal ion instrumentation is examined. A directly heated cathode provides the electrons used to produce ions by impact ionization and an applied magnetic field increases the path length followed by the electrons. The electrostatic and variable geometry magnetic mirror configuration in the ion source is studied. The procedures for the charge neutralization of the beam and the configuration and function of the 1.4-m drift tube are analyzed. A microcomputer is utilized to control and monitor the beam energy and composition, and the mass- and angle-dependent response of the instrument under testing. The facility produces a high-quality ion beam with an adjustable range of energies up to 150 eV; the angular divergence and uniformity of the beam is obtained from two independent retarding potential analyzers. The procedures for calibrating the instrument being developed are described.

Biddle, A. P.↗

Thermal-energy reactions of O2(2+) ions with O2, N2, CO2, NO, and Ne

The paper presents results of drift-tube mass-spectrometer studies of the reactivity of doubly charged molecular oxygen ions with several molecules and neon atoms. Thermal-energ rate coefficients for the reactions with the molecular reactants were found to be large, close to the limiting Langevin rates. Charge transfer with neon atoms was observed, but the measured rate coefficient was only a small fraction of the Langevin rate. It is concluded that the measured rate constants for the reactions considereed refer to vibrationally excited ions.

Chatterjee, B. K.↗

Plasmaspheric wind

Observational evidence is presented indicating that beyond L = 1.7-2 plasma corotating in the plasmasphere expands continuously with a small outward directed bulk velocity perpendicular to geomagnetic field lines. A numerical simulation of plasmaspheric flux tube drift motion is presented in support of such an outward plasma expansion. The maximum expansion velocity inside the plasmasphere is determined by the maximum value of the plasma interchange velocity, which is inversely proportional to the value of the integrated Pedersen conductivity.

Lemaire, J.↗

Effect of Coulomb interaction on time of flight of cold antiprotons launched from an ion trap

Time-of-flight spectra for Maxwell-Boltzman (MB) distributions of antiprotons initially held in an ion trap and detected after being launched through a 50-cm-long shielding drift tube have been calculated. The distributions used are of temperature 0.4-40 K, cubic length 0.003-3.0 cm, and number 10-100 particles. The mutual Coulomb repulsion of the particles causes a reduction in the number of late arrival particles expected from the MB velocity distribution. The Coulomb energy is not equally divided among the particles during the expansion. The energy is transferred preferentially to the outer particles so that the reduction in the number of slow particles is not necessarily large. The reduction factor is found to be greater than unity when the potential energy of the trapped ions is greater than about 5 percent of the ions' kinetic energy and is about 2 for the launch parameters of the Los Alamos antiproton gravity experiment.

Camp, J. B.↗

Single and double charge transfer of He(2+) ions with molecules at near-thermal energies

Rate coefficients were measured for charge-transfer reactions of He(2+) ions with H2, N2, O2, CO, CO2, and H2O. The experiments were carried out using a selected-ion drift-tube mass spectrometer. Total rate coefficients are found to be very large and are generally close to the limiting Langevin capture rate coefficients or the corresponding ADO-model (Su and Bowers, 1973) coefficients. The product-ion spectra indicate that both single and double charge transfer and possibly transfer ionization occur in these reactions.

Tosh, R. E.↗

Evaluation of Thermal Control Coatings and Polymeric Materials Exposed to Ground Simulated Atomic Oxygen and Vacuum Ultraviolet Radiation

Numerous thermal control and polymeric samples with potential International Space Station applications were evaluated for atomic oxygen and vacuum ultraviolet radiation effects in the Princeton Plasma Physics Laboratory 5 eV Neutral Atomic Oxygen Facility and in the MSFC Atomic Oxygen Drift Tube System. Included in this study were samples of various anodized aluminum samples, ceramic paints, polymeric materials, and beta cloth, a Teflon-impregnated fiberglass cloth. Aluminum anodizations tested were black duranodic, chromic acid anodize, and sulfuric acid anodize. Paint samples consisted of an inorganic glassy black paint and Z-93 white paint made with the original PS7 binder and the new K2130 binder. Polymeric samples evaluated included bulk Halar, bulk PEEK, and silverized FEP Teflon. Aluminized and nonaluminized Chemfab 250 beta cloth were also exposed. Samples were evaluated for changes in mass, thickness, solar absorptance, and infrared emittance. In addition to material effects, an investigation was made comparing diffuse reflectance/solar absorptance measurements made using a Beckman DK2 spectroreflectometer and like measurements made using an AZ Technology-developed laboratory portable spectroreflectometer.

Kamenetzky, R. R.↗

Micro-machined planar field asymmetric ion mobility spectrometer as a gas chromatographic detector

A planar high field asymmetric waveform ion mobility spectrometer (PFAIMS) with a micro-machined drift tube was characterized as a detector for capillary gas chromatography. The performance of the PFAIMS was compared directly to that of a flame ionization detector (FID) for the separation of a ketone mixture from butanone to decanone. Effluent from the column was continuously sampled by the detector and mobility scans could be obtained throughout the chromatographic analysis providing chemical inforrmation in mobility scans orthogonal to retention time. Limits of detection were approximately I ng for measurement of positive ions and were comparable or slightly better than those for the FID. Direct comparison of calibration curves for the FAIMS and the FID was possible over four orders of magnitude with a semi-log plot. The concentration dependence of the PFAIMS mobility scans showed the dependence between ion intensity and ion clustering, evident in other mobility spectrometers and atmospheric pressure ionization technologies. Ions were identified using mass spectrometry as the protonated monomer and the proton bound dimer of the ketones. Residence time for column effluent in the PFAIMS was calculated as approximately 1 ms and a 36% increase in extra-column broadening versus the FID occurred with the PFAIMS.

NASA Discipline Life Sciences Technologies↗

Miniature Ion-Mobility Spectrometer

The figure depicts a proposed miniature ion-mobility spectrometer that would be fabricated by micromachining. Unlike prior ion-mobility spectrometers, the proposed instrument would not be based on a time-of-flight principle and, consequently, would not have some of the disadvantageous characteristics of prior time-of-flight ion-mobility spectrometers. For example, one of these characteristics is the need for a bulky carrier-gas-feeding subsystem that includes a shutter gate to provide short pulses of gas in order to generate short pulses of ions. For another example, there is need for a complex device to generate pulses of ions from the pulses of gas and the device is capable of ionizing only a fraction of the incoming gas molecules; these characteristics preclude miniaturization. In contrast, the proposed instrument would not require a carrier-gas-feeding subsystem and would include a simple, highly compact device that would ionize all the molecules passing through it. The ionization device in the proposed instrument would be a 0.1-micron-thick dielectric membrane with metal electrodes on both sides. Small conical holes would be micromachined through the membrane and electrodes. An electric potential of the order of a volt applied between the membrane electrodes would give rise to an electric field of the order of several megavolts per meter in the submicron gap between the electrodes. An electric field of this magnitude would be sufficient to ionize all the molecules that enter the holes. Ionization (but not avalanche arcing) would occur because the distance between the ionizing electrodes would be less than the mean free path of gas molecules at the operating pressure of instrument. An accelerating grid would be located inside the instrument, downstream from the ionizing membrane. The electric potential applied to this grid would be negative relative to the potential on the inside electrode of the ionizing membrane and would be of a magnitude sufficient to generate a moderate electric field. Positive ions leaving the membrane holes would be accelerated in this electric field. The resulting flux of ions away from the ionization membrane would create a partial vacuum that would draw more of the gas medium through the membrane. The figure depicts a filter electrode and detector electrodes located along the sides of a drift tube downstream from the accelerator electrode. These electrodes would apply a transverse AC electric field superimposed on a ramped DC electric field. The AC field would effect differential transverse dispersal of ions. At a given instant of time, the trajectories of most of the ions would be bent toward the electrodes, causing most of the ions to collide with the electrodes and thereby become neutralized. The DC field would partly counteract the dispersive effect of the AC field, straightening the trajectories of a selected species of ions; the selection would vary with the magnitude of the applied DC field. The straightening of the trajectories of the selected ions would enable them to pass into the region between the detector electrodes. Depending on the polarity of the voltage applied to the detector electrodes, the electric field between the detector electrodes would draw the selected ions to one of these electrodes. Hence, the current collected by one of the detector electrodes would be a measure of the abundance of ions of the selected species. The ramping of the filter- electrode DC voltage would sweep the selection of ions through the spectrum of ionic species.

Hartley, Frank T.↗