Search NASASearch

SEARCH · Search NASA

Results for “drop tower”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

65 records · Page 2

Li-ion EMU Battery Testing

A 45Ah Lithium ion (Li-Ion) battery comprised of 5 Yardney prismatic cells was evaluated to replace the silver-zinc cells in the Extra-vehicular Mobility Unit (EMU). Tests determined that the five cell battery can meet the mission objective of 500 duty cycles and maintain a minimum voltage of 16.0 V without an individual cell voltage dropping below 3.0V. Forty real time cycles were conducted to develop BOL trend data. Decision to switch to accelerated cycling for the remaining 460 cycles was made since Real Time cycling requires 1 day/cycle. Conclusions indicate that battery replacement would indeed be prudent.

Rehm, Raymond

Thermostructural Testing of PICA-D for NASA Planetary Science Missions

Phenolic Impregnated Carbon Ablator–Domestic (PICA‑D) has been selected as the heatshield thermal protection system (TPS) material for two upcoming NASA planetary science missions: the Dragonfly mission to Titan and the Mars Sample Retrieval Lander (SRL). Early testing revealed differences between PICA‑D and heritage PICA, particularly in in‑plane (IP) tensile stiffness and thermal expansion. Thermostructural analyses using Finite Element Method (FEM) tools subsequently predicted the potential for IP compressive failure in the near‑surface layers of PICA‑D under both Dragonfly and SRL flight environments. Over the past three years, the Dragonfly and SRL teams have carried out an extensive thermostructural qualification campaign to address these concerns and validate PICA‑D for flight. This effort began with a comprehensive mechanical property characterization program at Kratos test laboratories, which significantly improved understanding of PICA‑D mechanical behavior and increased the fidelity of FEM predictions. The teams also conducted six large‑scale test entries at the National Solar Thermal Test Facility (NSTTF) solar tower, exposing PICA‑D articles—including gap fillers and representative design features or flaws—to combined thermal and mechanical loads. The talk will summarize key findings from these mechanical and thermostructural test campaigns and present the current status of PICA‑D qualification for NASA’s planetary science missions.

TPS

The 10 September 2025 M w 4.1 Earthquake in Northeastern Utah, United States: An Archetypal Continental Mantle Event

The 10 September 2025 M w 4.1 earthquake in northeastern Utah, United States, had a focal depth 68 km beneath sea level, which is ∼20–25 km greater than estimates of local crustal thickness, making it a rare example of a continental mantle earthquake (CME). The focal depth is well resolved from arrival-time inversion (nearest station ∼13 km away) and moment tensor inversion of regional waveforms. Similar to other CMEs in the Intermountain West, there were no obvious aftershocks or foreshocks, and the waveforms were enriched in high-frequency energy. Spectral modeling gives a stress drop of ∼80 MPa and a radiation efficiency of ∼0.08, albeit with large uncertainties. The high stress drop and low radiation efficiency are consistent with a dissipative source process such as thermal runaway. Also similar to previous Intermountain West CMEs, the event occurred along the boundary of the Archean Wyoming craton, where pressure–temperature conditions favor ductile deformation. We hypothesize that edge-driven or regional-scale mantle convection produces increased strain rates near the craton boundary that make either conventional brittle failure or thermal runaway feasible at relatively high pressure–temperature conditions. High conductivity inferred around the edge of the craton may suggest that fluids also contribute to CME occurrence.

Koper, Keith D. [Univ. of Utah, Salt Lake City, UT

Ground Slope Effects on Lander Radiator Performance

Two sensitivity studies were performed to examine the drop in radiator heat rejection from slopes. Study #1 used a 5.5m tall reduced order asset to represent a small-lander/rover. Study #2 used a 20m asset represent a tall lander. The assets had body mounted horizontal, 45º inward-tilted, and vertical radiator orientations. The impact of slopes on different radiator orientations and on radiators pointing different directions (i.e., slope verses sun) was investigated. The studies were conducted at a polar location of -82.5ºS to capture the incident solar flux at the northmost, and therefore the hottest, range of potential Artemis landing sites (Mons Mouton Plateau).

Lunar Slope

Implementation of A Self-Controlling Heater

Temperature control of radiation sensors, targets, and other critical components is a common requirement in modern scientific instruments. Conventional control systems use a heater and a temperature sensor mounted on the body to be controlled. For proportional control, the sensor provides feedback to circuitry which drives the heater with an amount of power proportional to the temperature error. It is impractical or undesirable to mount both a heater and a sensor on certain components such as ultra-small parts or thin filaments. In principle, a variable current through the element is used for heating, and the change in voltage drop due to the element's temperature coefficient is separated and used to monitor or control its own temperature. Since there are no thermal propagation delays between heater and sensor, such control systems are exceptionally stable.

Maxwell G Strange

Amazonian fog harbors viable microbes

Fog formation over tropical forests remains poorly characterized, despite its potential role in bioaerosol dispersion and ecosystem processes. Here, we analyzed fog samples collected at the Amazon Tall Tower Observatory using flow cytometry and culture-based techniques to characterize viable microbial communities. Microbial cell concentrations varied over an order of magnitude across 13 fog events, reaching up to 8 × 104 cells per ml of fog water. Flow cytometry consistently detected metabolically active cells, while culturing and mass spectrometry-based identification yielded eight viable bacterial species and seven fungal taxa. The bacteria Serratia marcescens, Ralstonia pickettii and Sphingomonas paucimobilis exhibited seasonal variations in prevalence. The fungal species identified were primarily mesophilic saprophytes and endophytes, commonly associated with soil and plant surfaces. Our findings indicate that fog harbors viable microbes, including Serratia marcescens and Ralstonia pickettii, which may imply a relevance of fog for microbial dispersal, colonization and nutrient cycling in the Amazon rainforest.

Godoi, Ricardo H. (ORCID:0000000247744870)

Full-charge indicator for battery chargers

A full-charge indicator for battery chargers, includes a transistor which is in a conductive state as long as charging current to the battery is not less than a level which indicates that the battery did not reach full charge. When the battery reaches full charge, a voltage drop in a resistor in the charging current path is not sufficient to maintain the transistor in a conducting state, and therefore it is switched off. When this occurs an LED is turned on, to indicate a full charge state of the battery. A photocoupler together with a photocoupler transistor are included. When the transistor is off, the photocoupler activates the photocoupler transistor to shunt out a resistor, thereby reducing the charging current to the battery to a float charging current and prevent the battery from being overcharged and damaged.

Cole, Steven W.

Observing low-altitude features in ozone concentrations in a shoreline environment via uncrewed aerial systems

Abstract. Ozone is a pollutant formed in the atmosphere by photochemical processes involving nitrogen oxides (NOx) and volatile organic compounds (VOCs) when exposed to sunlight. Tropospheric boundary layer ozone is regularly measured at ground stations and sampled infrequently through balloon, lidar, and crewed aircraft platforms, which have demonstrated characteristic patterns with altitude. Here, to better resolve vertical profiles of ozone within the atmospheric boundary layer, we developed and evaluated an uncrewed aircraft system (UAS) platform for measuring ozone and meteorological parameters of temperature, pressure, and humidity. To evaluate this approach, a UAS was flown with a portable ozone monitor and a meteorological temperature and humidity sensor to compare to tall tower measurements in northern Wisconsin. In June 2020, as a part of the WiscoDISCO20 campaign, a DJI M600 hexacopter UAS was flown with the same sensors to measure Lake Michigan shoreline ozone concentrations. This latter UAS experiment revealed a low-altitude structure in ozone concentrations in a shoreline environment showing the highest ozone at altitudes from 20–100 m a.g.l. These first such measurements of low-altitude ozone via a UAS in the Great Lakes region revealed a very shallow layer of ozone-rich air lying above the surface.

Meteorology & Atmospheric Sciences

NASA Alternative Orion Small Cell Battery Design Support

The NASA Orion Crew Module Reference Design was produced to address large scale thermal runaway (TR) hazard with specific safety controls for the Orion Spacecraft. The design presented provides the description of a full scale battery design reference for implementation as a drop in replacement to meet all spacecraft energy requirements with compatible 120 Vdc electrical and mechanical interface using small cell technology (18650) packaging. The 32V SuperBrick incorporates unique support features and an electrical bus bar arrangement that allows cells negative can insertion into heat sink that is compressively coupled to the battery enclosure to promote good thermal management. The housing design also provides an internal flame suppression "filter tray" and positive venting path internal to the enclosure to allow hot effluent ejecta to escape in the event of single cell TR. Virtual cells (14P Banks) that are supported to provide cell spacing with interstitial materials to prevent side can failures that can produce cell to cell TR propagation. These features were successfully test in four separate TR run with the full scale DTA1 test article in February 2016. Successfully Completed Test Objectives - Four separate TR test runs with Full-Scale DTA1 housing with Two SuperBricks, Two SuperBrick Emulators All Tests resulted in "clean" gas with less than 6 C rise at Battery vent All Tests resulted in less than 2 C temperature rise on cold-plate outlet All Tests resulted in less than 6 psi pressure rise in the battery housing Test Run 1 -One neighbor cell TR, highest remaining neighbor 139 C. Ejecta shorted to bus caused prolonged additional heating, One shorted cell did experience TR after 12 minutes, remaining cells had adequate thermal margin Test Run 2 - No cell to cell propagation, highest neighbor cell 112 C; Test Run 3 - No cell to cell propagation, highest neighbor cell 96 C; Test Run 4 - No cell to cell propagation, highest neighbor cell 101 C; Primary TR testing and analysis were completed and reviewed for endorsement by NASA Engineering and Safety Center team members. All Key Test Objectives were met and the small cell design alternative was demonstrated and selected to be a feasible drop in replacement for the MPCV Orion CM Battery for EM2 mission.

Haynes, Chuck

Fifth International Microgravity Combustion Workshop

On behalf of the NASA Headquarters Microgravity Research Division and the Microgravity Combustion Science Discipline Working Group, we are pleased to present these proceedings of the Fifth International Microgravity Combustion Workshop. At the time we go to press we expect to welcome to the workshop over 250 presenters and participants from U.S. academia, industry, and government; and from at least 8 international partner countries. We come together for this workshop at the beginning of the International Space Station era, where the future of microgravity combustion science programs will unfold over the next few years. As we accelerate our preparations for the ISS, this book and the growing literature base cited herein provide a summary of the accomplishments of approximately forty space-flight experiment-missions (plus nearly countless drop tests and aircraft parabolas) and a valuable resource for the new experiment ideas of the future.

Kurt R Sacksteder

Development of a Thermal Radiator Optimization Tool with Alternate Coolants

The development of a modeling tool to optimize the design of a thermal radiator based on capacity, rejection temperature, geometry, type and coolant is presented. The radiator size is determined from the desired capacity, environmental conditions and rejection temperature. Flow through the radiator is derived from the overall heat load and prescribed inlet to outlet delta temperature for a given coolant. The tool considers radiator geometry (i.e., tube spacing and diameter, face-sheet thickness, overall size, etc.) and general type (i.e., parallel/manifold versus serpentine) in the optimization. Selection from a handful of potential coolants is also available in the tool which primarily affects necessary tube diameter to maintain turbulent flow and minimize pressure drop. An Equivalent System Mass (ESM) approach is utilized to include pump power in the optimization. Results from the tool and potential future enhancements are also discussed.

Coolant

Eddy Covariance Theory: A Review

Eddy covariance (EC), the gold standard for measuring ecosystem scale gas and heat exchanges, has transformed our understanding of the breathing of the biosphere, and thus global change biology. Despite numerous methodological improvements and insights gained from the technique, the community faces persistent challenges that have been present since the first EC measurements. Here, we review the theoretical developments underpinning EC. We present theoretical developments in four important areas that have relevance to EC measurements of the net ecosystem exchanges (NEE) of gases and heat from a single tower: (i) measuring the total vertical flux density, (ii) flux attenuation, (iii) coordinate rotations, and (iv) energy balance closure. Persistent problems with EC measurements, such as the inability to close the energy budget, led us to identify two priorities for revisiting the theory underlying: (i) sensible heat flux calculations, and (ii) constraining the mean vertical wind velocity. We present a framework for improved calculation of sensible heat flux derived from first principles of fluid mechanics and thermodynamics that considers coupled heat and mass transfer so that conservation of both is obeyed. These refinements are motivated by the need for unbiased measurements of energy and mass transfer between the land surface and atmosphere for ecosystem research and to validate satellite observations and land surface models.

ecosystem fluxes

Proactive Wildfire Management: A Remote Sensing and Multimodal CNN-MLP Architecture for Ignition Risk Forecasting

As the frequency and intensity of wildfires increase, with fire seasons now starting earlier and ending later than they have over the past decades, current monitoring systems, such as lookout towers and satellites, are hindered by cloud cover, low-resolution imagery, and static data gaps that fail to track vegetation moisture levels fast enough to catch rapid pre-ignition changes. This report proposes a Machine Learning-enabled Wildfire Ignition Prediction framework that combines satellite monitoring with dynamic and high-resolution remote sensing from Unmanned Aerial Vehicle (UAV) swarms. The method would use multispectral and thermal data from the Landsat program to create a baseline for vegetation health, calculating a two-band Enhanced Vegetation Index (EVI2) and the moisture content of the vegetation. These inputs will later be fused with microscale UAV weather data, including thermal hotspots found through thick canopies, hyperspectral chemical signatures of pre-visual combustion, and local weather streams. The multispectral satellite, multispectral Light Detection and Ranging (LiDAR), and thermal data would then be processed through a Convolutional Neural Network (CNN), alongside a Multilayer Perceptron (MLP) for the micro-weather telemetry. The outputs of these networks would be fused into a single feature representation and passed through a final prediction network to generate real-time ignition risk scores and hotspot alerts. Model performance would be assessed using standard classification metrics, including a Receiver Operating Characteristic - Area Under the Curve (ROC AUC) and F1 score. This system would allow first responders to identify high-risk zones and intervene before ignition occurs, improving emergency response time compared to current approaches.

machine learning

Investigating permafrost carbon dynamics in Alaska with artificial intelligence

Abstract Positive feedbacks between permafrost degradation and the release of soil carbon into the atmosphere impact land–atmosphere interactions, disrupt the global carbon cycle, and accelerate climate change. The widespread distribution of thawing permafrost is causing a cascade of geophysical and biochemical disturbances with global impacts. Currently, few earth system models account for permafrost carbon feedback (PCF) mechanisms. This research study integrates artificial intelligence (AI) tools and information derived from field-scale surveys across the tundra and boreal landscapes in Alaska. We identify and interpret the permafrost carbon cycling links and feedback sensitivities with GeoCryoAI, a hybridized multimodal deep learning (DL) architecture of stacked convolutionally layered, memory-encoded recurrent neural networks (NN). This framework integratesin-situmeasurements and flux tower observations for teacher forcing and model training. Preliminary experiments to quantify, validate, and forecast permafrost degradation and carbon efflux across Alaska demonstrate the fidelity of this data-driven architecture. More specifically, GeoCryoAI logs the ecological memory and effectively learns covariate dynamics while demonstrating an aptitude to simulate and forecast PCF dynamics—active layer thickness (ALT), carbon dioxide flux (CO 2 ), and methane flux (CH 4 )—with high precision and minimal loss (i.e. ALT RMSE : 1.327 cm [1969–2022]; CO 2 RMSE : 0.697µmolCO 2 m −2 s −1 [2003–2021]; CH 4 RMSE : 0.715 nmolCH 4 m −2 s −1 [2011–2022]). ALT variability is a sensitive harbinger of change, a unique signal characterizing the PCF, and our model is the first characterization of these dynamics across space and time.

Environmental Sciences & Ecology

Ranger Spacecraft

The thermal-control philosophy of the spacecraft currently under development by the Jet Propulsion Laboratory is design by passive means to maintain all components within the tolerances specified by cognizant engineers. Due to the complexity of the configurations, calculations are) of necessity, fairly generalized and final design is based upon tests in an environmental chamber. The Ranger series spacecraft is designed with a basic structure which is common to all models, with additional hardware to suit the individual mission. This basic structure of Rangers A-1 and A-2 is seen as the hexagonal instrument section, the erectable solar panels, the movable antenna, and the omniantenna. The Ranger A-1 and A-2 configuration is for engineering tests and space-exploration, with the scientific instrumentation isolation requirement dictating the spread-out design. The spacecraft stands 12 feet high, weighs 700 to 800 pounds, and has an internal power of 150 watts. Rangers A-3, A-4, and A-5 are designed to rough land a capsule on the moon. For these, a capsule and retrorocket replace the scientific instruments, occupying the space inside the tower structure. The spacecraft must survive many environments. Chronologically they are: 1) Folded configuration inside an aerodynamic shroud on the pad. 2) Thermal flux from shroud aerodynamically heated during boost phase. 3) Coasting up to 30 minutes attached to Agena stage after booster and shroud are separated. 4) Agena stage burning. 5) Coasting and tumbling after separation from Agena until it passes from earth's shadow. 6) Upon reaching sunlight, panels open and begin sun acquisition. 7) Antenna seeks earth after spacecraft locks onto sun. 8) Space phase- "steady state" with vehicle's vertical axis locked on sun, communicating with earth. The philosophy is to design for the sun-acquired mode, making allowances for the transient conditions.

T. O. Thostesen

Analysis of Developing Laminar Flows in Circular Pipes Using a Higher-Order Finite-Difference Technique

A higher-order finite-difference technique is developed to calculate the developing-flow field of steady incompressible laminar flows in the entrance regions of circular pipes. Navier-Stokes equations governing the motion of such a flow field are solved by using this new finite-difference scheme. This new technique can increase the accuracy of the finite-difference approximation, while also providing the option of using unevenly spaced clustered nodes for computation such that relatively fine grids can be adopted for regions with large velocity gradients. The velocity profile at the entrance of the pipe is assumed to be uniform for the computation. The velocity distribution and the surface pressure drop of the developing flow then are calculated and compared to existing experimental measurements reported in the literature. Computational results obtained are found to be in good agreement with existing experimental correlations and therefore, the reliability of the new technique has been successfully tested.

Herbert J Gladden

Advancing Building Performance: Field Results of Thin-Glass Triple-Pane Window Demonstrations

To meet California and the nation's ambitious energy targets, energy use in the building sector must drop dramatically. Windows continue to be the lowest thermally performing envelope system in the nation's buildings, resulting in poor overall envelope performance and potential impacts to human health and comfort. Current best practice new window performance is typically met by double-pane low-solar-gain glazing. Thin-glass triple-pane windows are a highly promising next step forward in performance and have been deployed in two California multi-family sites to quantify field performance and building energy savings. The technology assessed offers the performance benefits of traditional triple-pane but with little increase in weight or cost, enabling incremental costs competitive with alternative energy reduction solutions for the building envelope. This paper covers a detailed investigation into the demonstration project and measured performance benefits of the windows after a full year of data collection.

Hart, Robert

Evaluation of Cycle Life and Characterization of YTP 45 Ah Li-Ion Battery for EMU

Li-ion batteries, with longer cycle life and higher energy density features, are now more and more attractive and applied in multiple fields. The YTP 45 Ah Li-ion battery has been evaluated here and may be employed in EMU in the future. Evaluations were on: (1) Cycle life tests - 500 cycles total (completed 40 cycles in simulated shuttle use mode and 460 cycles in an accelerated use mode, and recorded differential voltage of individual cell in battery); (2) Characterization test - discharge capacity measurement in environment temperature of -10, 25, 50 C before and after 500 cycles; and (3) Thermal testing - charge and discharge at 50 C and -10 C before and after 500 cycles. The battery showed less than a 9% drop of initial discharge capacity and energy within 500 cycles with 475 cycles 59% DOD plus 25 cycles 100% DOD. The EOD voltage ranged from 16.0 to 18.0 V, which fits the requirement for operating the EMU.

Deng, Yi